• Title/Summary/Keyword: Radiographic comparative evaluation

Search Result 19, Processing Time 0.03 seconds

A COMPARATIVE STUDY ON ASSESSMENT OF CONDYLAR POSITION BY THE TMJ RADIOGRAPHY (악관절 방사선 촬영법에 따른 과두위 분석에 관한 비교 연구)

  • Lee Jin Hong;Park Chang Seo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.16 no.1
    • /
    • pp.81-91
    • /
    • 1986
  • The author obtained the trans cranial radiographs of right and left side and the individualized lateral tomograms of right and left side after the analysis of submental vertex view from 8 young adults of 25-32 years with normal occlusion. The condylar position from 32 radiographs of normal TMJs were assessed with each measurement methods. All datas from these analyses were recorded and statistically processed with CYBER computer system. The results were obtained as follows. 1. In each measurement methods, the area measurements using the midpoint fossa and the midpoint condyle revealed the hightest concordance rate between the radiographic pairs. 2. In the subjective evaluation, the qualitative concordance existed in 44% and the full concordance existed in 25%, so it was found that concordance rates were relatively low between the radiographic pairs. 3. In each measurement methods, the area measurement using the midpoint fossa revealed the strongest correlation between the radiographic pairs. 4. The correlations between the area measurement using the midpoint fossa and subjective valuation revealed relatively strong value which is 0.926 in the trans cranial radiographic series and the lowest value which is 0.743 in the tomographic series.

  • PDF

A Comparative Study of Radiographic Images on Normal Anatomical Structures (정상 해부학적 구조물에 대한 X-선 영상의 비교 연구)

  • Choi Heang-Hee;Choi Eui-Hwan;Kim Jae-Duk
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.29 no.1
    • /
    • pp.283-297
    • /
    • 1999
  • Purpose: To compare radiographic images of Digora/sup (R)/ system and Ektaspeed Plus film obtained from normal adults. Materials and methods: Storage phosphor plate(SPP) was placed in a film holder behind Ektaspeed Plus film package without lead foil. The effect of film on SPP was studied in a separate in vitro experiment. Forty-seven sets of images were prepared for the evaluaton. The regions of interest(ROI) for evaluation were designated at seven sites including normal anatomical structures. The image quality for each ROI was evaluated on enhanced and unenhanced storage phosphor(SP) images and Ektaspeed Plus film. Results: Two film-SPP configurations showed significantly different gray levels at each step of the aluminum step wedge(p<0.05). The contrasts were comparable. Enhanced SP images were significantly superior to unenhaned images and film in all anatomical sturctures(p<0.01). The differences between unenhanced SP images and film were significant(p<0.05) except root canal and cortical bone on alveolar crest. For anatomical items. there were statistically significant difference among five observers(p<0.05). Conclusions: The image quality of enhanced SP images were superior to Ektaspeed Plus film. and Digora system is potentially applicable to clinical diagnosis.

  • PDF

Radiographic Evaluation on the Forefoot: Based on the Two Different Data (1982 and 2004) (전족부의 방사선학적 관찰: 1982년과 2004년의 차이를 중심으로)

  • Rowe, Sung-Man;Lee, Keun-Bae;Park, Yu-Bok;Kim, Byung-Soo;Kim, Yung-Jin
    • Journal of Korean Foot and Ankle Society
    • /
    • v.9 no.1
    • /
    • pp.1-8
    • /
    • 2005
  • Purpose: We compared the bony arrangements of the forefoot in 2 different years, 1982 and 2004, to determine any changes with time period of 22 years. Materials and Methods: The radiographs of 200 normal Korean adults, 100 male and 100 female volunteers, were evaluated both in 1982 and 2004. The radiographic results were evaluated with as follows; hallux valgus angle (HVA), intermetatarsal angle (IMA), morphology of metatarsal head and relative anterior protrusion of the metatarsals and the phalanges. The mean ages were 38 years (23-52years) in 1982, and 37 years (24-50years) in 2004. Results: The mean of HVA decreased from 15.6 degrees in 1982 to 14.3 degrees in 2004 (p=0.047), and the mean of IMA increased from 8.0 degrees in 1982 to 9.4 degrees in 2004 (p=0.031). The morphology of metatarsal head and relative anterior protrusion of the metatarsals and the phalanges were not different between the two study years. Conclusion: Comparing with those of 1982 measurements, we found an increase of IMA and a decrease of HVA. A prospective study may be needed to illuminate course of the changes.

  • PDF

A COMPARATIVE STUDY OF TOMOGRAPHY WITH LATERAL OBLIQUE TRANSCRANIAL RADIOGRAPHY IN THE EVALUATION OF MANDIBULAR CONDYLAR POSITION (단층촬영법과 측사위경두개 촬영법을 이용한 정상인 하악과두 위치에 관한 비교 연구)

  • Lee Un Gyeong;Koh Kwang Joon
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.21 no.2
    • /
    • pp.353-365
    • /
    • 1991
  • The author analyzed and compared tomographs with lateral oblique transcranial radiographs of 60 temporomandibular joints from 30 asymptomatic young adults. The results were as follows: 1. The mean height & width of condylar head were 6.82±1.99㎜, 11.98±1.28㎜ in tomographs and 5.41±0.79㎜, 10.67±1.28㎜ in transcranial radiographs. The mean height of articular fossa was 10.19±1.60㎜ in tomographs and 8.44±1.65㎜ in transcranial radiographs. 2. The mean width of articular fossa was 20.71 ±2.98㎜ in tomographs and 17.47±2.58㎜ in transcranial radiographs. There were significant differences in both the height and the width of articular fossa between two radiographic techniques (P<0.01). 3. In centric occlusion, the superior joint spaces were 4.28±1.09㎜, 4.18±1.28㎜, the anterior joint spaces were 2.84±1.02㎜, 2.53±0.72㎜, the posterior joint spaces were 3.11±1.19㎜, 2.66±0.89㎜ in tomographs and transcranial radiographs respectively. There were significant differences in right posterior joint spaces (P<0.05), and posterior joint spaces (P<0.05) between two radiographic techniques. 4. The condylar position in articular fossa was displaced posteroinferiorly (-0.35±4.40㎜ posteriorly, -1.55±1.24㎜ inferiorly) in tomographs and anteroinferiorly (0.45±3.77㎜ anteriorly, -1.29±1.26㎜ inferiorly) in transcranial radiographs with 1 inch opening. In maximum opening, it was displaced anteroinferiorly (5.39±3.63㎜ anteriorly, -1.22±1.67㎜ inferiorly) in tomographs and anteroinferiorly (6.35±4.00㎜ anteriorly, -0.55 ±1.98㎜ inferiorly) in transcranial radiographs. There was significant difference in superoinferior positions of both condyles with maximum opening between two radiographic techniques (P<0.05).

  • PDF

[ $^{99m}Tc-MDP$ ] Scintigraphy in Osteoarthritis of Knee (퇴행성(退行性) 슬관절염(膝關節炎)에 대(對)한 골(骨)신티그라피)

  • Lee, Il-Sung;Park, Kyu-Ill;Lim, Myung-Ah;Lee, Sun-Wha
    • The Korean Journal of Nuclear Medicine
    • /
    • v.20 no.1
    • /
    • pp.45-52
    • /
    • 1986
  • In osteoarthritis of knee, sensitive and reproducible methods of evaluation are of particular importance in unicompartmental surgery, in which choice of technique and prognosis depend on accurate preoperative knowledge of distribution and extent of disease. The various diagnostic modalities for evaluation of osteoarthritic knee are present but it is known that $^{99m}Tc-MDP$ scintigraphy is the most sensitive and noninvasive method. The authors made a comparative study of scintigraphic findings and radiographic findings of 54 cases of osteoarthritic knees at Kyung Hee University Hospital from May' 83 to August' 85. The results were as follow: 1) $^{99m}Tc-MDP$ scintigraphy appeared more sensitive not only in detection of abnormal compartment but also in evaluation of severity of the diseased compartment compared to radiography. 2) We suggest that bone scintigraphy is most sensitive for preoperative information of extent and severity of the disease related to surgical technique and prognosis.

  • PDF

Comparative efficacy of photo-activated disinfection and calcium hydroxide for disinfection of remaining carious dentin in deep cavities: a clinical study

  • Sharma, Sidhartha;Logani, Ajay;Shah, Naseem
    • Restorative Dentistry and Endodontics
    • /
    • v.39 no.3
    • /
    • pp.195-200
    • /
    • 2014
  • Objectives: To comparatively evaluate the efficacy of photo-activated disinfection (PAD), calcium hydroxide (CH) and their combination on the treatment outcome of indirect pulp treatment (IPT). Materials and Methods: Institutional ethical clearance and informed consent of the patients were taken. The study was also registered with clinical registry of India. Sixty permanent molars exhibiting deep occlusal carious lesion in patients with the age range of 18 - 22 yr were included. Clinical and radiographic evaluation and set inclusion and exclusion criteria's were followed. Gross caries excavation was accomplished. In group I (n = 20) PAD was applied for sixty seconds. In group II (n = 20), CH was applied to the remaining carious dentin, while in group III (n = 20), PAD application was followed by CH placement. The teeth were permanently restored. They were clinically and radiographically followed-up at 45 day, 6 mon and 12 mon. Relative density of the remaining affected dentin was measured by 'Radiovisiography (RVG) densitometric' analysis. Results: Successful outcome with an increase in radiographic grey values were observed in all three groups. However, on inter-group comparison, this change was not significant (p > 0.05). Conclusions: PAD and CH both have equal disinfection efficacy in the treatment of deep carious dentin. PAD alone is as effective for treatment of deep carious lesion as calcium hydroxide and hence can be used as an alternative to CH. They can be used independently in IPT, since combining both does not offer any additional therapeutic benefits.

Comparison of three digital radiographic imaging systems for the visibility of endodontic files (근관 파일의 인지도 평가시 세 가지 디지털 방사선영상시스템의 비교)

  • Park Jong-Won;Kim Eun-Kyung;Han Won-Jeong
    • Imaging Science in Dentistry
    • /
    • v.34 no.3
    • /
    • pp.145-150
    • /
    • 2004
  • Purpose: To compare three digital radiographic imaging sensors by evaluating the visibility of endodontic file tips with interobserver reproducibility and assessing subjectively the clarity of images in comparison with the x-ray film images. Materials and Methods: Forty-five extracted sound premolars were used for this study. Fifteen plaster blocks were made with three premolars each and #8, 10, 15 K-flexofiles were inserted into the root canal of premolars. They were radiographically exposed using periapical x-ray films (Kodak Insight Dental film, Eastmann Kodak company, Rochester, USA), Digora imaging plates (Soredex-Orion Co., Helsinki, Finland), CDX 2000HQ sensors (Biomedisys Co., Seoul, Korea), and CDR sensors (Schick Inc., Long Island, USA). The visibility of endodontic files was evaluated with interobserver reproducibility, which was calculated as the standard deviations of X, Y coordinates of endodontic file tips measured on digital images by three oral and maxillofacial radiologists. The clarity of images was assessed subjectively using 3 grades, i.e. plus, equal, and minus in comparison with the conventional x-ray film images. Results: Interobserver reproducibility of endodontic file tips was the highest in CDR sensor (p < 0.05) only except at Y coordinates of #15 file. In the subjective assessment of the image clarity, the plus grade was the most frequent in CDR sensor at all size of endodontic file (p < 0.05). Conclusion : CDR sensor was the most superior to the other sensors, CDX 2000HQ sensor and Digora imaging plate in the evaluation of interobserver reproducibility of endodontic file tip and subjective assessment of image clarity.

  • PDF

Uniqueness of radiographic patterns of the frontal sinus for personal identification

  • Patil, Neha;Karjodkar, Freny R.;Sontakke, Subodh;Sansare, Kaustubh;Salvi, Rohini
    • Imaging Science in Dentistry
    • /
    • v.42 no.4
    • /
    • pp.213-217
    • /
    • 2012
  • Purpose: This study was performed to evaluate the uniqueness and reliability of the frontal sinuses by comparing various patterns of frontal sinus as observed on Waters' radiographs for individual identification. Materials and Methods: Three Waters' radiographs of 100 individuals, taken on day one, after 6-8 months, and one radiograph with a slight variation in angulation, to mimic conditions out in the field or during autopsy. Three observers were randomly given radiographs from all there packets for comparisons and identification, by the method of superimposition and individual uniqueness. Results: The comparative identification by superimposition of the frontal sinus was 100% positive. The size, shape, unilateral or bilateral presence, absence, and septa were observed to be unique in each case; neither had the measurements changed over a period of time. Conclusion: The need to establish a reliable, low-cost, and easily reproducible method for human identification prompted the elaboration of technical, precise, and accessible parameters, such as the evaluation of the area, asymmetry, and shape of the frontal sinus. Comparison among each of the frontal sinuses of the 100 people in the sample revealed that no two sinuses are the same, that is, the sinus is unique to each individual.

Comparative clinical and radiologic evaluation between patients undergoing standard reversed shoulder arthroplasty or bony increased offset

  • Tiago Amorim-Barbosa;Ana Ribau;Helder Fonte;Luis Henrique Barros;Rui Claro
    • Clinics in Shoulder and Elbow
    • /
    • v.26 no.1
    • /
    • pp.3-9
    • /
    • 2023
  • Background: Modifications of the medialized design of Grammont-type reverse shoulder arthroplasty (RSA) using a bony increased offset (BIO-RSA) has shown better clinical results and fewer complications. The aim of this study is to compare the clinical results, complications, and radiological outcomes between patients undergoing standard RSA and BIO-RSA. Methods: A retrospective review was performed of 42 RSA procedures (22 standard RSA and 20 BIO-RSA). With a minimum of 1 year of follow-up, range of motion (ROM), Constant shoulder score (CSS), visual analog scale (VAS), and subjective shoulder score (SSS) were compared. Radiographs and computed tomography (CT) scan were examined for scapular notching, glenoid and humeral fixation, and graft healing. Results: At a mean follow-up of 27.6 months (range, 12-48 months), a significant difference was found for active-internal rotation (P=0.038) and for passive-external rotation (P=0.013), with better results in BIO-RSA. No other differences were found in ROM, CSS (P=0.884), VAS score, and SSS. Graft healing and viability were verified in all patients with CT scan (n=34). The notching rate was 28% in the standard RSA group and 33% in the BIO-RSA group, but the standard RSA had more severe notching (grade 2) than BIO-RSA (P=0.039). No other significative differences were found in glenoid and humeral fixation. Conclusions: Bone-graft lateralization is associated with better internal and external rotation and with less severe scapular notching compared to the standard RSA. Integration of the bone graft occurs effectively, with no relevant changes observed on radiographic evaluation. Level of evidence: III.

An 1 year prospective comparative study evaluating the effect of microthread on the maintenance of marginal bone level (임프란트 미세나사선이 주위골 수준변화에 미치는 영향에 대한 1년간의 전향적 비교 연구)

  • Shin, Dong-Hwan;Cho, Kyoo-Sung;Park, Kwang-Ho;Moon, Ik-Sang
    • Journal of Periodontal and Implant Science
    • /
    • v.33 no.3
    • /
    • pp.349-358
    • /
    • 2003
  • The success of dental implant therapy relies mainly upon the presence and maintenance of bone adjacent to implant. An 1-year prospective study was performed, upon the patients who were diagnosed as having chronic adult periodontitis, and had been treated with dental implant. The purpose of this study was to measure the radiographic bone level changes proximal to Astra Tech Single Tooth Implants (ATST, Astra Tech AB, $M{\"{o}}lndal$, Sweden) with microthread and Astra Tech TiOblast Implant (ATTB) without microthread supporting fixed partial prosthesis. Measurements were used to determine mean marginal bone loss during the first year of loading, 17 subjects with its partial prosthesis supported by 37 implants were followed up for an 1-year period. The marginal bone loss of implants was positively correlated with the retention factor, microthread($Microthread^{TM}$) in crestal area of ATST. The results were as follows. 1. The mean marginal bone loss of ATST was 0.226${\pm}$0.395mm, while ATTB was 0.440${\pm}$0.360mm. There was a statistically significant difference between ATST and ATTB (p<0.05). 2. The mean bone loss of the upper jaw fixtures was 0.269${\pm}$0.265mm for ATST and 0.529${\pm}$0.417mm for ATTB . There was a statistically significant difference between ATST and ATTB (p<0.05). In the lower jaw the corresponding figures were 0.167${\pm}$0.231mm and 0.313${\pm}$0.214mm, respectively. There was no significant difference between ATST and ATTB (p>0.05). 3. The mean bone loss of ATST was lower than that of ATTB at all sites according to bone quality. There was a statistically significant difference between ATST and ATTB at bone quality type III(p <0.05). In conclusion, the mean bone loss of ATST was smaller than that of ATTB . Therefore, the retention factor of crestal area, microthread ($Microthread^{TM}$) was effective to maintenance of marginal bone level around fixture.