• Title/Summary/Keyword: Radiographic Measurement

Search Result 109, Processing Time 0.032 seconds

Retrospective Evaluation of Discrepancies between Radiological and Pathological Size of Hepatocellular Carcinoma Masses

  • Tian, Fei;Wu, Jian-Xiong;Rong, Wei-Qi;Wang, Li-Ming;Wu, Fan;Yu, Wei-Bo;An, Song-Lin;Liu, Fa-Qiang;Feng, Li;Liu, Yun-He
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.21
    • /
    • pp.9487-9494
    • /
    • 2014
  • Background: The size of a hepatic neoplasm is critical for staging, prognosis and selection of appropriate treatment. Our study aimed to compare the radiological size of solid hepatocellular carcinoma (HCC) masses on magnetic resonance imaging (MRI) with the pathological size in a Chinese population, and to elucidate discrepancies. Materials and Methods: A total of 178 consecutive patients diagnosed with HCC who underwent curative hepatic resection after enhanced MRI between July 2010 and October 2013 were retrospectively identified and analyzed. Pathological data of the whole removed tumors wereassessed and differences between radiological and pathological tumor size were identified. All patients were restaged using a modified Tumor-Node-Metastasis (TNM) staging system postoperatively according to the maximum diameter alteration. The lesions were classified as hypo-staged, iso-staged or hyper-staged for qualitative assessment. In the quantitative analysis, the relative pre and postoperative tumor size contrast ratio ($%{\Delta}size$) was also computed according to size intervals. In addition, the relationship between radiological and pathological tumor diameter variation and histologic grade was analyzed. Results: Pathological examination showed 85 (47.8%) patients were overestimated, 82 (46.1%) patients underestimated, while accurate measurement by MRI was found in 11 (6.2%) patients. Among the total subjects, 14 (7.9%) patients were hypo-staged and 15 (8.4%) were hyper-staged post-operatively. Accuracy of MRI for calculation and characterized staging was related to the lesion size, ranging from 83.1% to 87.4% (<2cm to ${\geq}5cm$, p=0.328) and from 62.5% to 89.1% (cT1 to cT4, p=0.006), respectively. Overall, MRI misjudged pathological size by 6.0 mm (p=0.588 ), and the greatest difference was observed in tumors <2cm (3.6 mm, $%{\Delta}size=16.9%$, p=0.028). No statistically significant difference was observed for moderately differentiated HCC (5.5mm, p=0.781). However, for well differentiated and poorly differentiated cases, radiographic tumor maximum diameter was significantly larger than the pathological maximum diameter by 3.15 mm and underestimated by 4.51 mm, respectively (p=0.034 and 0.020). Conclusions: A preoperative HCC tumor size measurement using MRI can provide relatively acceptable accuracy but may give rise to discrepancy in tumors in a certain size range or histologic grade. In pathological well differentiated subjects, the pathological tumor size was significantly overestimated, but underestimated in poorly differentiated HCC. The difference between radiological and pathological tumor size was greatest for tumors <2 cm. For some HCC patients, the size difference may have implications for the decision of resection, transplantation, ablation, or arterially directed therapy, and should be considered in staging or selecting the appropriate treatment tactics.

Ultrasonographic Measurement of Articular Cartilage Thickness of Medial Femoral Condyle in Knee Osteoarthritis (슬관절 골관절염에서 초음파를 이용한 대퇴 내과 관절 연골의 두께 측정)

  • Kim, Jung-Man;Kim, Tae-Hyung;Im, Dong-Sun;Kang, Min-Gu;Lee, Kyu-Jo
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.4 no.1
    • /
    • pp.7-14
    • /
    • 2011
  • Purpose: The purpose of this study was to analyze the correlation between the medial joint space on weight bearing simple X-ray and the ultrasonographic articular cartilage thickness. Materials and Methods: The articular cartilage thickness of 91 osteoarthritic knees of 73 patients were measured with weight bearing simple X-ray and ultrasonography between June 2010 and September 2010. Male were 13 and female were 60. Right knees were 35, left knees were 20 and bilateral involvements were 18. Medial joint spaces on X-ray were measured in full extension view and $45^{\circ}$ PA(Rosenberg) view. Femoral cartilage thicknesses at and those at the point between the middle 1/3 and posterior 1/3 area were measured by ultrasonography, that were scanned coronally at $30^{\circ}$ flexion and $130^{\circ}$ flexion respectively. The results were analyzed statistically by Pearson correlation test and Bland-Altman plot test. Results: Medial joint spaces measured in full extension view and femoral articular cartilage thicknesses at the point between the anterior 1/3 and middle 1/3 area measured with sonography were statistically correlated and medial joint spaces measured in $45^{\circ}$ PA view and those at the point between the middle 1/3 and posterior 1/3 area measured with sonography were also correlated (P<0.05, $SD{\pm}2$). Conclusion: The measurement of articular cartilage thicknesses by the ultrasonography was easy even in the patient who are unable to take weight bearing view and was thought to be a useful diagnostic and follow up method to examine the degenerative change in addition to simple radiographic examination in the knee osteoarthritis.

  • PDF

MEASUREMENT OF PULPAL BLOOD FLOW USING A LASER DOPPLER FLOWMETER (Laser Doppler flowmeter를 이용한 치수혈류 측정)

  • Ban, Tae-Whan;Lee, Jae-Sang;Kim, Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.24 no.4
    • /
    • pp.560-569
    • /
    • 1999
  • Blood supply rather than nerve supply implies pulp vitality. To evaluate pulp vitality clinically, electric pulp test and thermal test which are based on sensory nerve response have been used in addition to many auxiliary data such as past dental history, visual inspection, radiographic examination, percussion, palpation and transillumination test. However, reactivity of the nerves to the stimulation is not synonymous with normalcy. Therefore measurement of pulpal blood flow using a laser Doppler flowmeter became a new trial to test the pulp vitality. The purpose of the present study was to evaluate normal pulpal blood flow level of maxillary teeth in adult to provide a guideline in determining the vitality of dental pulp. Pulpal blood flow was measured in maxillary central and lateral incisors, canines, first and second premolars and first molars of seventy nine adults of 22 - 30 years old using a laser Doppler flowmeter (PeriFlux 4001, Perimed Co., Stockholm, Sweden, 780 nm infrared laser, 1mW). For directly-made splints, silicone rubber impressions were taken directly from the mouth. For indirectly-made splints, alginate impressions were taken from the mouth and stone cast were made. After making depressions on the buccal surfaces of the cast teeth to indicate the hole positions, second impressions with vinyl polysyloxane putty were taken from the cast. Holes for the laser probes were made at the putty impressions 4mm above the gingival level. Laser probe (PF416 dental probe, 1.5mm) was inserted in the prepared hole and the splint was set in the mouth. After 10 minutes of patient relaxing, pulpal blood flow was recorded for 5 minutes on each tooth. The recorded flow was saved in the computer and calculated with a software 'Perisoft' version 5.1. Pulpal blood flow was also recorded in six teeth of five individuals with no response to electric pulp test and cold test, with periapical radiolucency, or with history of root canal treatment to compare with nonvital teeth. The difference between the mean flow values of each group of teeth were analyzed using one-way ANOVA and Duncan's Multiple Range test. The results were as follows: 1. The average pulpal blood flow values of all the tested teeth of each location were between 9 - 16 Perfusion Unit. Pulpal blood flow value was highest in maxillary lateral incisors, followed by first premolars, second premolars, canines, central incisors, and then first molars (p<0.01). 2. In six anterior teeth, indirectly-made splint group showed higher pulpal blood flow values than directly-made splint group (p<0.01). In posterior teeth, however, there was no significant flow value difference between directly-made splint group and indirectly-made splint one (p>0.05). 3. Teeth with vital pulps showed higher signal values than teeth with nonvital pulps (p<0.01), and the flow photographs showed heartbeat-synchronous fluctuations and vasomotions, while those were absent in non vital tooth.

  • PDF

The effect of PostGraft$^{TM}$ on implants were installed at the tibia of ovariectomized rats (난소절제술한 백서에 식립한 임플란트에 대한 PostGraft$^{TM}$의 경구 투여 효과)

  • Cho, Chun-Il;Kim, Se-Won;Choi, Yu-Sung;Cho, In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.4
    • /
    • pp.300-307
    • /
    • 2011
  • Purpose: This study evaluated PostGraft$^{TM}$ which enhances implant stability and bone density. Materials and methods: Forty eight implants were installed at the tibia of ovariectomized rats. The group administrated with PostGraft$^{TM}$ was the experimental group, and the control group was not administrated. Implant stability was evaluated at the $2^{nd}$, $4^{th}$ and $6^{th}$ week by Periotest value, bone mineral density, bone-to-implant contact. These values were analyzed statistically with Mann-Whitney U test (P<.05). Histological analysis was evaluated at the $2^{nd}$, $4^{th}$ and $6^{th}$ week. Results: According to the Periotest$^{(R)}$ measurement, both experimental and control groups showed decrease in values as time elapsed. Greater decrease was observed in the experimental group but there was no significant difference. By examining the radiographic images, both experimental and control groups showed tendency of increase in bone density. Greater increase was seen in the experimental group but there was no significant difference. According to the bone-to-implant contact measurement, both experimental and control groups showed increase in values as time elapsed. Greater increase was seen in the experimental group. At the $2^{nd}$ and $4^{th}$ week, there was no significant difference. But at the $6^{th}$ week, there was significant difference (P<.05). By histological analysis, both experimental and control groups showed increase in bone formation as time elapsed. In addition, greater increase was seen in the experimental group. Conclusion: It could be concluded that the PostGraft$^{TM}$ medicated group showed better results in the bone density and osseointegration.

Measurement of shoulder motion fraction and motion ratio (견관절 운동 분율의 측정)

  • Kang, Yeong-Han
    • Journal of radiological science and technology
    • /
    • v.29 no.2
    • /
    • pp.57-62
    • /
    • 2006
  • Purpose : This study was to understand about the measurement of shoulder motion fraction and motion ratio. We proposed the radiological criterior of glenohumeral and scapulothoracic movement ratio. Materials and Methods : We measured the motion fraction of the glenohumeral and scapulothoracic movement using CR(computed radiological system) of arm elevation at neutral, 90 degree, full elevation. Central ray was $15^{\circ},\;19^{\circ},\;22^{\circ}$ to the cephald for the parallel scapular spine, and the tilting of torso was external oblique $40^{\circ},\;36^{\circ},\;22^{\circ}$ for perpendicular to glenohumeral surface. Healthful donor of 100 was divided 5 groups by age(20, 30, 40, 50, 60). The angle of glenohumeral motion and scapulothoracic motion could be taken from gross arm angle and radiological arm angle. We acquired 3 images at neutral, $90^{\circ}$ and full elevation position and measured radiographic angle of glenoheumeral, scapulothoracic movement respectively. Results : While the arm elevation was $90^{\circ}$, the shoulder motion fraction was 1.22(M), 1.70(W) in right arm and 1.31, 1.54 in left. In full elevation, Right arm fraction was 1.63, 1.84, and left was 1.57, 1.32. In right dominant arm(78%), $90^{\circ} and Full motion fraction was 1.58, 1.43, in left(22%) 1.82, 1.94. In generation 20, $90^{\circ} and Full motion fraction was 1.56, 1.52, 30' was 1.82, 1.43, 40' was 1.23, 1.16, 50' was 1.80, 1.28, 60' was 1.24, 1.75. There was not significantly by gender, dominant arm and age. Conclusion : The criterior of motion fraction was useful reference for clinical dignosis the shoulder instability.

  • PDF

Imaging dose evaluations on Image Guided Radiation Therapy (영상유도방사선치료시 확인 영상의 흡수선량평가)

  • Hwang, Sun Boong;Kim, Ki Hwan;kim, il Hwan;Kim, Woong;Im, Hyeong Seo;Han, Su Chul;Kang, Jin Mook;Kim, Jinho
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.1
    • /
    • pp.1-11
    • /
    • 2015
  • Purpose : Evaluating absorbed dose related to 2D and 3D imaging confirmation devices Materials and Methods : According to the radiographic projection conditions, absorbed doses are measured that 3 glass dosimeters attached to the centers of 0', 90', 180' and 270' in the head, thorax and abdomen each with Rando phantom are used in field size $26.6{\times}20$, $15{\times}15$. In the same way, absorbed doses are measured for width 16cm and 10cm of CBCT each. OBI(version 1.5) system and calibrated glass dosimeters are used for the measurement. Results : AP projection for 2D imaging check, In $0^{\circ}$ degree absorbed doses measured in the head were $1.44{\pm}0.26mGy$ with the field size $26.6{\times}20$, $1.17{\pm}0.02mGy$ with the field size $15{\times}15$. With the same method, absorbed doses in the thorax were $3.08{\pm}0.86mGy$ to $0.57{\pm}0.02mGy$ by reducing field size. In the abdomen, absorbed dose were reduced $8.19{\pm}0.54mGy$ to $4.19{\pm}0.09mGy$. Finally according to the field size, absorbed doses has decreased by average 5~12%. With Lateral projection, absorbed doses showed average 5~8% decrease. CBCT for 3D imaging check, CBDI in the head were $4.39{\pm}0.11mGy$ to $3.99{\pm}0.13mGy$ by reducing the width 16cm to 10cm. In the same way in thorax the absorbed dose were reduced $34.88{\pm}0.93(10.48{\pm}0.09)mGy$ to $31.01{\pm}0.3(9.30{\pm}0.09)mGy$ and $35.99{\pm}1.86mGy$ to $32.27{\pm}1.35mGy$ in the abdomen. With variation of width 16cm and 10cm, they showed 8~11% decrease. Conclusion : By means of reducing 2D field size, absorbed dose were decreased average 5~12% in 3D width size 8~11%. So that it is necessary for radiation therapists to recognize systematical management for absorbed dose for Imaging confirmation. and also for frequent CBCT, it is considered whether or not prescribed dose for RT refer to imaging dose.

  • PDF

Serum Immunoglobulin levels in Coal Worker's Pneumoconiosis Patients (진폐증 환자에서의 혈청 면역 글로불린의 변화)

  • Yoo, Kwang-Ha;Ahn, Chul-Min;Kim, Hyung-Joong;Kim, Young-Ho;Lee, Yong-Kyoo;Kim, Sung-Kyu;Lee, Won-Young
    • Tuberculosis and Respiratory Diseases
    • /
    • v.46 no.2
    • /
    • pp.165-174
    • /
    • 1999
  • Background: Coal-worker's pneumoconiosis(CWP) is radiologically divided into two major groups: simple pneumoconiosis (SP), in which small, rounded or irregular opacities smaller than 1cm are observed, and progressive massive fibrosis(PMF), which is characterized by opacities larger than 1cm. SP has a life expectancy equivalent to miners with no radiographic evidence of CWP, but PMF is associated with more obvious impairments of ventilatory capacity and premature death. But only minority of workers develop PMF when exposed to dust concentrations similar to those experienced by workers who develop only SP. In this study, immune status in patients with CWP were evaluated by measurement of the serum immunoglobulin levels between control, SP and PMF groups. Method: Coal workers selected for this study were emplyees of the Tae-Baek and Dong-Hae Hospital. All the patients were men of 45-76 years old and the mean duration of exposure to coal dust were 23.2 years. By X-ray examination, 51 patients were classified in SP, 59 in PMF category. The normal controls examined were 58 men of 26-70 years old. Serum Ig levels were estimated by using Nephelometer(Behring Nephelometer : Germany) and serum were collected 51 in SP, 49 in PMF and 57 cases in control group. Results: The levels of IgG were increased but the levels of IgM were decreased with increasing age in control groups. There were no statistical difference of immunoglobulin levels between smokers and nonsmokers in control groups. There were no statistical difference of immunoglobulin levels between Control, SP and PMF groups. Multiple regression analysis were undertaken to determine the statistical significance of the apparent trends and estimate the effects associated with age, smoking habit and radiological category of CWP. According to this analysis, the levels of IgG were decreased significantly in SP group and had decreasing tendancy, but not statistically significant in PMF group. Conclusion : From the observations described, CWP patients had decreased IgG concentration compared to control gorup. Therefore, there was some relation between CWP and immunoglobulin concentration.

  • PDF

DEVELOPMENT OF THREE DIMENSIONAL MEASURING PROGRAM WITH FRONTAL AND LATERAL CEPHALOMETRIC RADIOGRAPHS -PART 1. COMPUTATION OF THE THREE-DIMENSIONAL COORDINATES BY COMPENSATION OF THE ERROR OF THE HEAD POSITION IN ORDINARY NON-BIPLANAR CEPHALOSTAT- (정모 및 측모 두부 방사선 규격사진을 이용한 3차원 계측 프로그램의 개발 -1. 단일 방사선원으로 촬영된 두부 방사선사진의 두부 위치 보정을 이용한 3차원 좌표의 산출-)

  • Lee, Geun-Ho;Lee, Sang-Han;Jang, Hyon-Joong;Kwon, Tae-Geon
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.27 no.3
    • /
    • pp.214-220
    • /
    • 2001
  • The clinical application of the three-dimensional radiographic technique had been limited to standard Broadbent-Bolton cephalometer with biplanar stereoradiography. We developed a new method for compensating the error of head position in ordinary non-biplanar cephalostat. It became to possible to use the three dimensional cephalogram commonly in clinical bases. 1. The method of methemetical compensation of head positioning error in non-biplanar condition was evaluated with dry skull. The error of the method of first and the second trial was $0.46{\pm}1.21$, $0.33{\pm}0.90mm$, which means the error of the head positioning correction in conventional cephalogram was within clinical acceptance. 2. The reproducibility of this system for clinical application was 0.54 mm ($-2.99{\sim}2.26mm$) which defines the absolute mean difference of the first and second trial. Compare to the The landmark identification error $1.2{\pm}1.6mm$, the error of the measurement was within the range of landmark identification error. The result indicates the adequate clinical accuracy of the computation of three-dimensional coordinates by compensation of the error of the head position in ordinary non-biplanar cephalostat.

  • PDF

Comparison of Radiologic Parameters between Weight Bearing Affected Both Ankle and Single Ankle in Ankle Exam (체중부하 상태의 족관절 검사시 양측 족관절 동시 검사와 편측 족관절 검사의 방사선학적 비교)

  • Cha, Sangyoung;Shin, Jaehan;Choi, Namgil
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.8
    • /
    • pp.603-610
    • /
    • 2016
  • This study was performed to analyze the results of radiologic parameters compared both leg weight bearing position to single leg weight bearing position in ankle osteoarthritis. Between January 2016 and June 2016, 25 patients (50 ankles) who visited our Hospital to treat ankle pain. In radiographic assessment, We masured tibial anterior surface angle(TAS), tibial medial malleolar angle(TMM), talar tilting angle(TT), joint space width(JSW), tibiotalar joint space, fibulotalar joint space of ankle as radiologic parameters. On the right leg of the both leg weight bearing position, TAS was $87.24^{\circ}$, TT was $6.44^{\circ}$, TMM was $26.76^{\circ}$, fibulotalar joint space was 0.98mm. Right leg of the single leg weight bearing position, TAS was $88.93^{\circ}$, TT was $2.41^{\circ}$, TMM was $19.77^{\circ}$, fibulotalar joint space was 1.6mm. And then, on the left leg of the both leg weight bearing position, TAS was $87.25^{\circ}$, TT was $5.71^{\circ}$, TMM was $23.92^{\circ}$, fibulotalar joint space was 1.22 mm and left leg of the single weight bearing position, TAS was 88.75, TT was $3.19^{\circ}$, TMM $21.45^{\circ}$, fibulotalar joint space was 1.22 mm. There are unsimilarity between measure values of TAS and tibiotalar joint space. As the result of test of weight bearing ankle study, it would be more exact to examine to measure one side in the first time rather than both to conclude on accurate measurement.