• Title/Summary/Keyword: Radiofrequency Ablation

Search Result 148, Processing Time 0.028 seconds

Treatment of glabellar frown lines using selective nerve block with radiofrequency ablation (고주파절제술을 통한 선택적 신경차단법을 이용한 미간주름의 개선)

  • Hwang, Yong Seok;Kim, Young Seok;Roh, Tai Suk;Tark, Kwan Chul;Lee, Kun Chang
    • Archives of Plastic Surgery
    • /
    • v.36 no.2
    • /
    • pp.205-210
    • /
    • 2009
  • Purpose: Corrugator supercilii muscle pulls eyebrow to inferomedial direction and produces the vertical component of the glabellar line formation. Current techniques for eliminating of glabellar frown include direct resection of corrugators and botulinum toxin injection. Muscle resection in endoscopic face lift procedure is relatively complex and has many disadvantages ranging from possible nerve injury, postoperative edema, pain and a long recovery period. The Botox treatment on the other hand is much more simple in technique but has a short duration of action. The authors have attempted new ways of finding improved treatment of the glabellar frown by selectively blocking of motor nerves innervating the corrugator supercili muscle by using radiofrequency ablation technique. Methods: A total of 80 patients were recruited in our study during the period between Feb. 2007 to June 2008. A probe was introduced from the supraorbital ridge and advanced to the corrugator supercilii muscle. Nerve stimulator was then used to locate the nerve innervating the corrugator and radiofrequency ablation of the nerve was done. Results: In all patients, there were marked improvement in glabellar frown after treatment. There were no reported cases of any relapses during the follow up period. No complication was noted such as facial nerve injury. No patient complained of any adverse symptoms other than slight discomfort due to swelling of the operation site. Conclusion: The treatment of glabellar frown lines using selective nerve block with radiofrequency ablation was not only less invasive but also excellent in surgical outcomes.

Comparison of Ablation Performance between Octopus Multipurpose Electrode and Conventional Octopus Electrode

  • Sae-Jin Park;Jae Hyun Kim;Jeong Hee Yoon;Jeong Min Lee
    • Korean Journal of Radiology
    • /
    • v.24 no.2
    • /
    • pp.86-94
    • /
    • 2023
  • Objective: To compare Octopus multipurpose (MP) electrodes, which are capable of saline instillation and direct tissue temperature measurement, and conventional electrodes for radiofrequency ablation (RFA) in porcine livers in vivo. Materials and Methods: Sixteen pigs were used in this study. In the first experiment, RFA was performed in the liver for 6 minutes using Octopus MP electrodes (n = 15 ablation zones) and conventional electrodes (n = 12 ablation zones) to investigate the effect of saline instillation. The ablation energy, electrical impedance, and ablation volume of the two electrodes were compared. In the second experiment, RFA was performed near the gallbladder (GB) and colon using Octopus MP electrodes (n = 12 ablation zones for each) with direct tissue temperature monitoring and conventional electrodes (n = 11 ablation zones for each). RFA was discontinued when the temperature increased to > 60℃ in the Octopus MP electrode group, whereas RFA was performed for a total of 6 minutes in the conventional electrode group. Thermal injury was assessed and compared between the two groups by pathological examination. Results: In the first experiment, the ablation volume and total energy delivered in the Octopus MP electrode group were significantly larger than those in the conventional electrode group (15.7 ± 4.26 cm3 vs. 12.5 ± 2.14 cm3, p = 0.027; 5.48 ± 0.49 Kcal vs. 5.04 ± 0.49 Kcal, p = 0.029). In the second experiment, thermal injury to the GB and colon was less frequently noted in the Octopus MP electrode group than that in the conventional electrode group (16.7% [2/12] vs. 90.9% [10/11] for GB and 8.3% [1/12] vs. 90.9% [10/11] for colon, p < 0.001 for all). The total energy delivered around the GB (2.65 ± 1.07 Kcal vs. 5.04 ± 0.66 Kcal) and colon (2.58 ± 0.57 Kcal vs. 5.17 ± 0.90 Kcal) were significantly lower in the Octopus MP electrode group than that in the conventional electrode group (p < 0.001 for all). Conclusion: RFA using the Octopus MP electrodes induced a larger ablation volume and resulted in less thermal injury to the adjacent organs compared with conventional electrodes.

V-Y Latissimus Dorsi Musculocutaneous Flap for Reconstruction of Radiation-induced Skin Injuries on the Back (V-Y 광배근피판을 이용한 등의 방사선 유발 피부 손상의 치험)

  • Shim, Seung-Hyun;Chung, Chul-Hoon;Kim, Kuyl-Hee
    • Archives of Plastic Surgery
    • /
    • v.38 no.5
    • /
    • pp.707-710
    • /
    • 2011
  • Purpose: Cardiac radiofrequency catheter ablation procedures using fluoroscopy were performed for the treatment of supraventricular and selected ventricular tachyarrhythmia. Fluoroscopy is used to localize the position of the intracardiac catheter. Fluoroscopically-guided procedures often involve high radiation doses to patient's skin, but the incidence of serious radiation injuries in these patients is rare. We reported two cases of severe postradiation skin injury on the back treated with the V-Y latissimus dorsi musculocutaneous flap. Methods: These two patients underwent radiofrequency catheter ablation under the diagnosis of Woff Parkinson White syndrome (WPW syndrome). They had radiation-induced skin injuries on the subscapular area and these lesions represented chronic ulceration, surrounding induration, hardness, and dyspigmentation. We treated these lesions with complete excision and coverage with V-Y latissimus dorsi musculocutaneous flap. Results: These two patients had no recurrence and no special complications during 20 months and 12 months follow-up periods and were satisfied aesthetically and functionally. Conclusion: V-Y latissimus dorsi musculocutaneous flap obtained better results functionally and aesthetically compared with conservative management and skin graft in severe radiation-induced skin injuries after cardiac radiofrequency catheter ablation procedure.

Clinical Approach for Thyroid Radiofrequency Ablation (갑상선 고주파 절제술을 위한 임상진료)

  • Jung Suk Sim
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.5
    • /
    • pp.1017-1030
    • /
    • 2023
  • Radiofrequency ablation (RFA) is a non-surgical treatment for symptomatic, benign thyroid nodules. This treatment works by heating and destroying the nodule tissue, which results in reduction of its size and alleviation of the symptoms involved. RFA is indicated for nodules which are confirmed to be benign on two or more cytological or histological examinations, and which result in clinical symptoms requiring medical treatment. It is associated with good short-term outcomes on one-year follow-up; however, 20%-30% of the nodules regrow after more than three years. Therefore, on the basis of long-term follow-up, management of regrowth is key to patient care following RFA. Regrowth is more likely to occur in nodules that are large in size prior to RFA, and in those with high or increased vascularity. Recently, new techniques such as hydrodissection, artery-first ablation, and venous ablation have been introduced to inhibit regrowth. In addition, appropriate criteria for additional RFA should be applied to manage regrowth and prolong its therapeutic effects. RFA is essentially an alternative to surgery; therefore, the ultimate goal of this procedure is to avoid surgery permanently, rather than to achieve temporary effects.

Pulmonary Vein to Esophageal Fistula after Staged Hybrid Totally Thoracoscopic Surgical and Percutaneous Radiofrequency Catheter Ablation: A Case Report

  • Park, Byung-Jo;Kim, Yong Han;Jeong, Dong Seop;Choi, Yong Soo;On, Young Keun
    • Journal of Chest Surgery
    • /
    • v.47 no.6
    • /
    • pp.560-562
    • /
    • 2014
  • A case of a fistula running from the pulmonary vein to the esophagus after a staged hybrid procedure combining total thoracoscopic ablation and percutaneous radiofrequency catheter ablation has not been reported previously. We describe such a case in a 37-year-old man who was successfully treated by surgery.

Impact of Energy and Access Methods on Extrahepatic Tumor Spreading and the Ablation Zone: An Ex vivo Experiment Using a Subcapsular Tumor Model

  • Jin Sil Kim;Youngsun Ko;Hyeyoung Kwon;Minjeong Kim;Jeong Kyong Lee
    • Korean Journal of Radiology
    • /
    • v.20 no.4
    • /
    • pp.580-588
    • /
    • 2019
  • Objective: To evaluate the impact of energy and access methods on extrahepatic tumor spreading and the ablation zone in an ex vivo subcapsular tumor mimic model with a risk of extrahepatic tumor spreading. Materials and Methods: Forty-two tumor-mimics were created in bovine liver blocks by injecting a mixture of iodine contrast material just below the liver capsule. Radiofrequency (RF) ablations were performed using an electrode placed parallel or perpendicular to hepatic surface through the tumor mimic with low- and high-power protocols (groups 1 and 2, respectively). Computed tomography (CT) scans were performed before and after ablation. The presence of contrast leak on the hepatic surface on CT, size of ablation zone, and timing of the first roll-off and popping sound were compared between the groups. Results: With parallel access, one contrast leak in group 1 (1/10, 10%) and nine in group 2 (9/10, 90%) (p < 0.001) were identified on post-ablation CT. With perpendicular access, six contrast leaks were identified in each group (6/11, 54.5%). The first roll-off and popping sound were significantly delayed in group 1 irrespective of the access method (p = 0.002). No statistical difference in the size of the ablation zone of the liver specimen was observed between the two groups (p = 0.247). Conclusion: Low-power RF ablation with parallel access is proposed to be effective and safe from extrahepatic tumor spreading in RF ablation of a solid hepatic tumor in the subcapsular location. Perpendicular placement of an electrode to the capsule is associated with a risk of extrahepatic tumor spreading regardless of the power applied.

The Evaluation of Usefulness for Liver RF Ablation Which was being guide by CT (CT 유도하에 시행하는 Liver RF Ablation의 유용성 평가)

  • Kim Dong Soo;Lee Won Kyun;Lee Kang Woo
    • Journal of The Korean Radiological Technologist Association
    • /
    • v.28 no.1
    • /
    • pp.145-152
    • /
    • 2002
  • Purpose : Radiofrequency(RF) ablation has known effective treatment in patient with hepatocellular carcinoma(HCC) or hepatic metastases tumor(HMT). The purpose of this study was to evaluate the usefulness of performed patient liver RF ablation guide by CT

  • PDF

Percutaneous Radiofrequency ablation for the Treatment of Osteoid osteoma (유골골종의 경피적 고주파 열 치료)

  • Seo, Jai-Gon;Jung, Kwang-Hoon;Yang, Il-Soon
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.8 no.3
    • /
    • pp.83-89
    • /
    • 2002
  • Purpose: To analyze the postoperative functional and radiographic follow-up results in patients who underwent percutaneous radiofrequency ablation therapy after the diagnosis of osteoid osteoma. Materials and Methods: Seven patients, who were clinically and radiographically diagnosed with osteoid osteoma from July 1999 to January 2001, and received percutaneous radiofrequency ablation therapy. The average follow-up period was 15.5 months(range, 8~25 months). For the diagnosis and accurate localization of the lesion, simple radiography, computed tomography and magnetic resonance imaging(MRI) were performed preoperatively. Simple radiographs and MRI were taken periodically for the follow-up studies. Results: In all 7 patients, symptoms completely disappeared within 3 days after the operation. The average period of hospitalization was 2.4 days, excluding 1 patient who needed an additional burn treatment. The average postoperative night and day pain scores were 1.8 and 1.3, respectively. The average vocational and recreational activity scores were 1 and 0.6, respectively. Conclusions: Satisfactory functional results were obtained with percutaneous radiofrequency ablation therapy for the elimination of osteoid osteoma. Compared to conventional treatment, the advantages of this therapy were short hospitalization period, no internal fixation and bone graft for preventing fracture, and no limitation of joint motion by long fixation period.

  • PDF

Evaluation of Peri-procedural Anticoagulation Drug Therapy undergoing Radiofrequency Ablation in Patients with Atrial Fibrillation (심방세동 환자의 고주파 도자절제술 전.후의 항응고약물요법 사용실태 분석)

  • Kim, Su-Hyun;An, Sung-Shim;Kim, Soon-Joo;Bang, Joon-Seok;La, Hyen-Oh
    • Korean Journal of Clinical Pharmacy
    • /
    • v.20 no.2
    • /
    • pp.159-164
    • /
    • 2010
  • Radiofrequency ablation (RA) is being used to manage atrial fibrillation (AF) with patients failed at the $1^{st}$-line anti-arrhythmic medications. Patients undergoing this procedure are at increased risk of thromboembolism after ablation, and anticoagulation management surrounding the ablation remains controversial. Although no conclusive recommendations can be made, published guidelines and data support therapeutic anticoagulation with warfarin. The purpose of this study was to analyze effectiveness of current therapy and to find factors fluctuate International Normalized Ratio (INR) values in patients undergone RA followed by anticoagulation service (ACS). Retrospective review was conducted utilizing database in a hospital. Among 110 patients under warfarin around ablation between January 2006 to September 2007, 54 patients were selected and allocated into 2 groups: Group A included 47 who discontinued warfarin after ablation, while 7 in B continued the medication. Information on demographics, amount and length of warfarin dosing, INR values and measuring frequencies, and the causing factors on INR fluctuation were abstracted. Differences were analyzed using chi-squared test, Fisher's Exact test, and unpaired Student t-test. Mean amount of warfarin before and after surgery was 4.0 mg, 4.1 mg in Group A and was 5.1 mg, 4.6 mg in Group B, respectively. Average duration of warfarin doing before ablation was 73.7 days in Group A, 129.9 days in B with no significant difference (p = 0.312). The duration time of warfarin on groups after ablation lasted several months. The number of checking INRs was 4.1 and 7.6, respectively. Inter-individual variability of INR fluctuations were $2.1{\pm}0.6$ in Group A and $2.2{\pm}0.7$ in B which were not significantly different (p = 0.062). 164 cases of decreased INR were: 'omission in taking medication, stressfulness and headache, 'increased intake of high vitamin K foods', 'lifestyle change of increased physical activities', and 'increase of food-intakes'. To the contrary, 36 cases of increased INR were: 'reduce of food-intake', 'use of non-prescription drugs', 'reduction in physical activities', and 'excessive restriction on food-intake', consecutively. In conclusion, the study validated therapeutic outcomes of RA patients who we treated with standard guideline and demonstrated 9 factors of INR fluctuations in the patient. A well-trained, pharmacist-monitored anticoagulation service could reduce the risk of adverse effects and prevent complications in patients with AF around RA operation.