• Title/Summary/Keyword: Radiofrequency (RF)

Search Result 96, Processing Time 0.026 seconds

Extraction Method of Ultrasound Spectral Information using Phase-Compensation and Weighted Averaging Techniques (위상 보상과 가중치 평균을 이용한 의료 초음파 신호의 주파수 특성 추출 방법)

  • Kim, Hyung-Suk;Yi, Joon-Hwan
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.4
    • /
    • pp.959-966
    • /
    • 2010
  • Quantitative ultrasound analysis provides fundamental information of various ultrasound parameters using spectral information of the short-gated radiofrequency(RF) data. Therefore, accurate extraction of spectral information from backscattered RF signal is crucial for further analysis of medical ultrasound parameters. In this paper, we propose two techniques for calculating a more accurate power spectrum which are based on the phase-compensation using the normalized cross-correlation to minimize estimation errors due to phase variations, and the weighted averaging technique to maximize the signal-to-noise ratio(SNR). The simulation results demonstrate that the proposed method estimates better results with 10% smaller estimation variances compared to the conventional methods.

A Novel High Speed Frequency Sweeping Signal Generator in X-band Based on Tunable Optoelectronic Oscillator

  • Sun, Mingming;Chen, Han;Sun, Xiaohan
    • Current Optics and Photonics
    • /
    • v.2 no.1
    • /
    • pp.53-58
    • /
    • 2018
  • A novel X-band high speed frequency sweep signal generator based on a tunable optoelectronic oscillator (OEO) incorporating a frequency-swept laser is presented and the theoretical fundamentals of the design are explained. A prototype of the generator with tuning range from 8.8552 GHz to 10.3992 GHz and a fine step about 8 MHz is achieved. The generated radiofrequency signal with a single sideband (SSB) phase noise lower than -100 dBc/Hz@10KHz is experimentally demonstrated within the whole tunable range, without any narrow RF band-pass filters in the loop. And the tuning speed of the frequency sweep signal generator can reach to over 1 GHz/s benefiting from applying a novel dispersion compensation modular instead of several tens of kilometers of optical fiber delay line in the system.

Analysis of Chemical and Morphological Changes of Phenol Formaldehyde-based Photoresist Surface caused by O2 Plasma

  • Shutov, D.A.;Kang, Seung-Youl;Baek, Kyu-Ha;Suh, Kyung-Soo;Min, Nam-Ki;Kwon, Kwang-Ho
    • Transactions on Electrical and Electronic Materials
    • /
    • v.8 no.5
    • /
    • pp.211-214
    • /
    • 2007
  • Chemical and morphological changes of phenol formaldehyde-based photoresist after $O_2$ radiofrequency(RF) plasma treatment depending on exposure time and source power were investigated. It was found that etch rate of photoresist sharply increased after discharge turn on and reached a limit with increase in plasma exposure time. Contact angle measurements and X-ray photoelectron spectroscopy(XPS) analysis showed that the surface chemical structure become nearly constant after 15 sec of the treatment. Atomic force microprobe(AFM) measurements were shown that surface roughness was increased with plasma exposure time.

Electrosurgery Sparks induced Stimulating Current at Active Electrode

  • Kim, Ji-Hun;Na, Byeong-Geun;Bae, In-Sik;Seol, Yu-Bin;Jang, Hong-Yeong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.08a
    • /
    • pp.318-318
    • /
    • 2011
  • Electrosurgery has been widely used in surgical procedures for many years. The surgical procedure using radiofrequency power generated occasionally sparks causing electrical stimulations. According to a paper of commercialized APC (Argon Plasma Coagulation) in the gastrointestinal endoscopy, Patients treated by APC had experienced pain and neuromuscular stimulation. This study aimed to investigate the electrosurgery sparks. In this experiment, current threshold of electrosurgery using rf was investigated. Sparks analogous to surgical situation was generated and measured the I-V figure. Asymmetric current, observed by other researchers, was also measured. This could be explained by difference between positive phase and negative phase. Furthermore, a method was developed to remove asymmetric current and to make safer device for surgical field.

  • PDF

Flexible Engineering Tool for Radiofrequency Parameter Identification of RF-MEMS BAW Filters

  • Mabrouk, Mohamed;Boujemaa, Mohamed-Ali;Choubani, Fethi
    • ETRI Journal
    • /
    • v.38 no.5
    • /
    • pp.988-995
    • /
    • 2016
  • In this paper, we present a new specific and customized interface tool with parameter identification of Modified Butterworth-Van Dyke models for ladder bulk acoustic wave filters. The aforementioned tool is easy to use and flexible because it allows simulations and reengineering to be conducted in an application. A modular design approach is applied to simplify the extension of the proposed tool for different topologies. The proposed tool was validated using measurements from an aluminum-nitride based ladder BAW filter dedicated to the frequency ranges of the Universal Mobile Telecommunications Service and standards and Wideband Code Division Multiple Access.

Evaluation of the Utility of Self Produced MRI Radiofrequency Shielding Material (자체 제작한 자기공명영상 고주파 차폐체의 유용성 평가)

  • Lee, Jin-Hoe;Lee, Bo-Woo
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.11
    • /
    • pp.89-94
    • /
    • 2020
  • This paper proposes a better shielding method to over sampling technique. The new method uses aluminum foil for RF shielding. As a result of the phantom test, when the over-sampling technique was applied, the aliasing artifact was reduced by about 94% compared to before the application, and the case where the aluminum shielding band was applied was also reduced by about 92% compared to before application. In addition, the scan time also increased by more than 3 times in the case of the over-sampling technique, while it was found that there was no change from before the application of the aluminum shielding band Therefore, it was confirmed that the shielding band using aluminum foil can effectively remove aliasing artifacts without increasing the scan time..

Hyperthermia for Head and Neck Cancer - Preliminary Result of Hyperthermia Using 8 MHz Radiofrequency in Treatment of Advanced and Recurrent Head and Neck Cancer- (두경부암의 온열요법 -국소적으로 진행 혹은 재발된 두경부암 치료에 있어서 8MHz 라디오파를 이용한 온열요법의 중간보고 -)

  • Park K.R.;Lee C.G.;Kim S.K.;Cho K.H.;Suh C.O.;Kim G.E.;Loh J.K.;Kim B.S.;Hong W.P.;Park C.S.
    • Korean Journal of Head & Neck Oncology
    • /
    • v.3 no.1
    • /
    • pp.107-114
    • /
    • 1987
  • Clinical application of hyperthermia using 8 MHz radiofrequency(capacitive type THERMOTRON RF-8) in cancer treatment was begun at Yonsei Cancer Center in 1985. From April 1985 to April 1986, 23 patients with loco-regionally advanced and persistent or recurrent carcinomas of the head and neck were treated with hyperthermia at the Department of Radiation Oncology, Yonsei University College of Medicine. Radiation therapy and/or chemotherapy were combined with hyperthermia to improve the tumor response. The response rate of 23 patients was 52%, 4 had complete response, and 7 had partial response. The factors affecting the tumor response were dose of irradiation(P=0.009). Complications related to treatment were found in 8 patients and all of them were self-limited. The result of this study indicates that localized hyperthermia as a combined modality has a significant role in palliation of advanced and recurrent head and neck cancer.

  • PDF

Synthesis of Gold Nanoparticles by Electro-reduction Method and Their Application as an Electro-hyperthermia System

  • Yoon, Young Il;Kim, Kwang-Soo;Kwon, Yong-Soo;Cho, Hee-Sang;Lee, Hak Jong;Yoon, Chang-Jin;Yoon, Tae-Jong
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.6
    • /
    • pp.1806-1808
    • /
    • 2014
  • We report the successful preparation of gold nanoparticles (Au NPs) using a novel electroreduction process, which is simple, fast, and environmentally friendly (toxic chemicals such as strong reducing agents are not required). Our process allows for the mass production of Au NPs and adequate particle size control. The Au NPs prepared show high biocompatibility and are non-toxic to healthy human cells. By applying radio-frequency (RF) ablation, we monitored the electro-hyperthermia effect of the Au NPs at different RFs. The Au NPs exhibit a fast increase in temperature to $55^{\circ}C$ within 5 min during the application of an RF of 13 MHz. This temperature rise is sufficient to promote apoptosis through thermal stress. Our work suggests that the selective Au NP-mediated electro-hyperthermia therapy for tumor cells under an RF of 13 MHz has great potential as a clinical treatment for specific tumor ablation.

Preliminary Phantom Experiments to Map Amino Acids and Neurotransmitters Using MRI

  • Oh, Jang-Hoon;Kim, Hyug-Gi;Woo, Dong-Cheol;Rhee, Sun Jung;Lee, Soo Yeol;Jahng, Geon-Ho
    • Progress in Medical Physics
    • /
    • v.29 no.1
    • /
    • pp.29-41
    • /
    • 2018
  • The objective of this study was to evaluate the chemical exchange saturation transfer (CEST) effect of amino acids and neurotransmitters, which exist in the human brain, depending on the concentration, pH, and amplitude of the saturation radiofrequency field. Phantoms were developed with asparagine (Asn), ${\gamma}-aminobutyric$ acid (GABA), glutamate (Glu), glycine (Gly), and myoinositol (MI). Each chemical had three different concentrations of 10, 30, and 50 mM and three different pH values of 5.6, 6.2, and 7.4. Full Z-spectrum CEST images for each phantom were acquired with a continuous-wave radiofrequency (RF) saturation pulse with two different $B_1$ amplitudes of $2{\mu}T$ and $4{\mu}T$ using an animal 9.4T MRI system. A voxel-based CEST asymmetry was mapped to evaluate exchangeable protons based on amide (-NH), amine ($-NH_2$), and hydroxyl (-OH) groups for the five target molecules. For all target molecules, the CEST effect was increased with increasing concentration and B1 amplitude; however, the CEST effect with varying pH displayed a different trend depending on the characteristics of the molecule. On CEST asymmetric maps, Glu and MI were well visualized around 3.0 and 0.9 ppm, respectively, and were well separated macroscopically at a pH of 7.4. The exchange rates of Asn, Glu, BABA, and Gly usually decreased with increasing pH. The CEST effect was dependent on the concentration, acidity of the target molecules, and B1 amplitude of the saturation RF pulse. The CEST effect for Asn can be observed in a 9.4T MRI system. The results of this study are based on applying the CEST technique in patients with neurodegenerative diseases when proteins in the brain are increased with disease progression.

Fabrication of Combined Probes for Interstitial hyperthermia and Brachyradiotherapy (고 선량율 근접 및 온열치료 병용 삽입관의 제작과 특성)

  • Chu, Sung-Sil;Kim, Sung-Kyu
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2004.11a
    • /
    • pp.85-87
    • /
    • 2004
  • We fabricated flexible thermoradiotherapy probes to alternated combination with Interstitial hyperthermia and Brachyradiotherapy thermoradiotherapy probe was coated by gold plate on polyethylene brachytherapy probe. When Agar phantom was heated 15 minute with 30 W radiofrequency power, temperature increased as 5oC for polyethylene probe and 20oC for gold coated polyethylene probe. We observed that the 1 cm square array would heat a volume with a 1.25 cm radius circular field cross section to therapeutic temperatures (90% relative SAR using Tm) and the 2 cm square array with a 1.75 cm radius rectangular field with central inhomogeneity. With 2 cm long electrode implants, we observed that the 1 cm square array would heat a 3 cm long sagittal section to therapeutic temperature (90% relative SAR using Tm). The histopathological changes associated with RF heating of normal canine brains have been correlated with thermal distributions. RF needle electrode heating was applied for 50 min to generate tissue temperatures of 43${\circ}$C. We obtained a quarter of the heated tissue material immediately after heating and sacrificed at intervals from 7${\sim}$30 days. The acute stage was demonstrated by liquefactive necrosis, pyknosis of neuronal element in the gray matter. Mild gliosis occurring around the necrosis was demonstrated in the last sacrificed (days30)canine brain.

  • PDF