• 제목/요약/키워드: Radioactivity Concentration

검색결과 196건 처리시간 0.022초

Estimation of the Endogenous Pancreatic/Biliary Zinc Pool and the Effect of Phytate and Calcium on Zinc Homeostasis

  • Kwun, In-Sook;Donald Oberleas
    • Preventive Nutrition and Food Science
    • /
    • 제2권1호
    • /
    • pp.35-41
    • /
    • 1997
  • The pancreas is an important organ in the maintenance of zinc homeostasis. Endogenous zinc is con-tinuously secreted via pancreatic exocrine fluid or to a lesser extent in bile. Much of the endogenous secretion must be reabsorbed to sustain zinc homeostasis. The objective of this study was to estimate the relative size of the pancreatic/biliary zinc pool in comparision to the dietary zinc intake, and to study the effect of the phytate and calcium on the zinc homeostasis using a rat model. At the termination of the experiment, pan-creatic/biliary fluid was collected from the rats. Both radioactivity and total zinc were measured and the relative size of the pancreatic/biliary zinc pool was estimated. To determine the effect of phytate and calcium on zinc homeostsis, dietary zinc intake, the amount of zinc in pancreatic.biliary fluid and fecal zinc excretion were measured. The flow rate of pancreatic/biliary fluid, as corrected for tubing constriction, gives the corrected zinc concentration in the pancreatic/biliary fluid was 2.2 times higher than dietary zinc intake. To maintain zinc homeostasis, zinc absorption/reabsorption was very efficient in the current model; 76%, 88% of absorption/reabsorption for low calcium group and high calcium group 81% for phytate group and non-phytate group, respectively.

  • PDF

110mAg 간섭으로부터 137Cs 정량평가를 위한 드럼핵종분석 교정기술 (Calibration Method of the Tomographic Gamma Scan Techniques Available for Accurately Characterizing 137Cs from 110mAg Interference)

  • 정성엽
    • 방사성폐기물학회지
    • /
    • 제14권1호
    • /
    • pp.57-61
    • /
    • 2016
  • The Tomographic Gamma Scan (TGS) technique partitions radioactive waste drums into $10{\times}10{\times}16$ voxels and assays both the density and concentration of radioactivity for each voxel thus providing for improved accuracy, when compared to the traditional Non-Destructive Assay(NDA) techniques. It could decrease the degree of precision measurement since there is a trade-off between spatial resolution and precision. This latter drawback is compensated by expanding the Region of Interest (ROI) that differentiates the full energy peaks, which, in turn, results in an optimized degree of precision. The enlarged ROI, however, increases the probability of interference among those nuclides that emit energies in the adjacent spectrum. This study has identified the cause of such interference for the reference nuclide of the TGS technique, $^{137}Cs$ (661.66 keV, half-life 30.5 years), to be $^{110m}Ag$ (657.75 keV, half-life 249.76 days). A new calibration method of determining the optimized ROI was developed, and its effectiveness in accurately characterizing $^{137}Cs$ and eliminating the interference was further ascertained.

방사성 토양폐기물 시료의 통계적 대표성에 관한 연구 (A Study on the Statistical Representativeness of Samples taken from Radioactive Soil)

  • 조한석;김태국;이강무;안섬진;손종식
    • 한국방사성폐기물학회:학술대회논문집
    • /
    • 한국방사성폐기물학회 2005년도 춘계 학술대회
    • /
    • pp.151-157
    • /
    • 2005
  • 한국원자력연구소에서는 토양폐기물의 규제해제를 통한 처리를 위하여 토양의 핵종 및 방사능분석에 대한 절차를 개발하고 있다. 토양의 규제해제를 위한 기반작업으로 대표성 있는 시료를 추출하기 위하여 균질화, 평균화를 거쳐 임의추출(random sample)하는 시료추출의 방법론을 결정하였다. 통계학적인 관점에서의 대표성은 시료추출의 방법론 뿐 만 아니라 시료의 크기를 얼마로 할 것인가에 대한 설계가 선행 되어야 한다. 본 연구에서는 토양폐기물에서 시료를 채취하는 절차에 따라 예비시료를 추출한 후 핵종 및 방사능평가 작업을 수행한 결과를 사용하여 신뢰구간과 오차 한계에 따른 시료의 개수를 산정하였다.

  • PDF

동전기적방법을 이용한 방사능오염토양 내의 세슘 제거 (Cesium Removal from Soil Contaminated with Radioactivity Using Electrokinetic Method)

  • 김계남;원휘준;김민길;박진호;오원진
    • 한국방사성폐기물학회:학술대회논문집
    • /
    • 한국방사성폐기물학회 2003년도 가을 학술논문집
    • /
    • pp.696-700
    • /
    • 2003
  • $H_2SO_4$과 Citric acid 은 다른 화학물질보다 토양으로부터 $^{137}Cs$의 추출효율이 높았다. 오래 저장된 방사능오염 토양으로부터 $^{137}Cs$ 제거효율을 높이기 위해 동전기방법에 의한 토양복원 실험 시 $H_2SO_4$과 citric acid를 첨가제로 사용했다. 실험 컬럼으로부터 방출된 방출수의 평균속도는 $2.0{\times}10^{-2}$cm/min이고, 10일 동안 방출된 토양폐액의 부피는 3.6 Pore Volume이다. 10일간 컬럼 내의 $^{137}Cs$의 제거효율이 54%이었다. 한편, 개발된 모델에 의해 계산된 잔류농도 예측 값은 실험으로부터 구한 결과와 거의 일치했다.

  • PDF

구조화된 논쟁 전략이 공통과학 환경 단원 학습에 미치는 효과 (The Effects of Structured Controversy Strategy on the Learning of Environmental Unit in General Science)

  • 한재영;노태희
    • 한국환경교육학회지:환경교육
    • /
    • 제13권1호
    • /
    • pp.44-52
    • /
    • 2000
  • In this study, the effects of structured controversy strategy, individual learning, and traditional learning on the learning of environmental unit in ‘General Science’ were compared. One hundred and forty-three 10th-graders had been taught about environmental issues-self purification, biological concentration, acid rain, greenhouse effect, noise, and radioactivity-for 6 class hours. Prior to the instructions, environmental attitudes test and self-esteem test were administered. After the instructions, their achievements, critical thinking, environmental attitudes. self-esteem, and views on Science-Technology-Society were examined. The results of 2-way ANCOVA and/or Kruskal-Wallis test revealed that there were no significant main effects in the scores of the achievement test and the critical thinking test. The environmental attitudes test scores tended to be highest in the structured controversy group, and lowest in the traditional learning group. Self-esteem scores of the structured controversy group and the individual learning group were higher than those of the traditional learning group. Significant differences by students' prior achievement level in students' critical thinking, environmental attitudes, and views on Science-Technology-Society were also found.

  • PDF

의료용 선형가속기 차폐 재질로써 일반 콘크리트와 저 방사화 콘크리트 비교 (Comparison of General Concrete and Low-radiation Concrete as Shielding Materials for Medical Linear Accelerators)

  • 이동연;김정훈
    • 한국방사선학회논문지
    • /
    • 제13권1호
    • /
    • pp.45-53
    • /
    • 2019
  • 본 연구는 의료용 선형가속기 시설을 차폐하는 콘크리트에 대한 중성자 방사화 연구로써, 일반 콘크리트와 저 방사화 콘크리트를 비교 분석하였다. 실험 방법은 MCNPX (Ver. 2.5.0)와 FISPACT-2010를 사용하여 모의실험을 진행하여, 광자선과 중성자선에 대한 차폐능을 산정하고 중성자 방사화 평가를 진행하였다. 그 결과 차폐능은 일반 콘크리트에서 20~50 cm 효율적이였으며, 방사화 평가의 경우 저 방사화 콘크리트에서 방사능이 낮게 계산되었으나, 모두 자체처분허용 농도를 초과하지 않는 수준으로 산정되었다. 이를 종합적으로 분석한 결과 일반 콘크리트를 사용하는 것이 효율적인 것으로 판단된다.

HTO 형태 시료 조제 조건에 따른 삼중수소 계측에 미치는 영향 평가 (Evaluation of Effects on Tritium Measurement According to HTO Type Sample Preparation Conditions)

  • 안은미;김정훈;이홍연;한상준;김보길
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제44권4호
    • /
    • pp.381-387
    • /
    • 2021
  • In this study, for the measurement of 3H(tritium) radioactivity concentration, a study was conducted on whether the type of cocktail and the material of the vial had an effect on the measurement before liquid scintillation counter measurement on HTO-type samples that had undergone physical and chemical pretreatment. As a result of the study, the efficiency according to the type of cocktail was higher in Ultima Gold LLT than Ultima Flo-AP cocktail with polyethylene (1.49%), glass (5.10%), and teflon (6.58%), respectively. Regarding the effect according to the type of vial, the efficiency and SQP(E) of both Ultima Gold LLT and Ultima Flo-AP showed the highest values in the order of teflon, polyethylene, and glass.

Preliminary ALARA residual radioactivity levels for Kori-1 decommissioning and analysis of results and effects of remediation area

  • Seo, Hyung-Woo;Yu, Ji-Hwan;Kim, Gi-Lim;Son, Jin-Won
    • Nuclear Engineering and Technology
    • /
    • 제54권3호
    • /
    • pp.1136-1144
    • /
    • 2022
  • The effects of nearby residents and the public by the residual contamination from the decommissioning of nuclear facilities should comply with the dose criteria, and whether additional remediation action is necessary from the ALARA perspective must be determined. Therefore, we analyzed the requirements of ALARA action levels and performed preliminary ALARA evaluation. The ratio of residual contamination concentration to DCGL was calculated for the basement fill and the building occupancy mode. The results showed that the additional remediation actions below DCGL are not justified. In addition, we analyzed the effect of remediation area. It was noted that the increase of the remediation area showed a positive correlation with the Conc/DCGL value in the basement fill mode. On the other hand, in the building occupancy mode, since the floor area of the building is the target of remediation and has the effect of increasing the same as the evaluation area of the building occupants, but due to the difference in the amount of increase, the Conc/DCGL showed a negative correlation. We expect the approach and method of ALARA evaluation can be utilized for concrete cost-benefit calculation during the decommissioning or at the time of remediation.

Assessment of occupational radiation exposure of NORM scales residues from oil and gas production

  • EL Hadji Mamadou Fall;Abderrazak Nechaf;Modou Niang;Nadia Rabia;Fatou Ndoye;Ndeye Arame Boye Faye
    • Nuclear Engineering and Technology
    • /
    • 제55권5호
    • /
    • pp.1757-1762
    • /
    • 2023
  • Radiological hazards from external exposure of naturally occurring radioactive materials (NORM) scales residues, generated during the extraction process of oil and gas production in southern Algeria, are evaluated. The activity concentrations of 226Ra, 232Th, and 40K were measured using high-purity gamma-ray spectrometry (GeHP). Mean activity concentration of 226Ra, 232Th and 40K, found in scale samples are 4082 ± 41, 1060 ± 38 and 568 ± 36 Bq kg-1, respectively. Radiological hazard parameters, such as radium equivalent (Raeq), external and internal hazard indices (Hex, Hin), and gamma index (Iγ) are also evaluated. All hazard parameter values were greater than the permissible and recommended limits and the average annual effective dose value exceeded the dose constraint (0.3 mSv y-1). However, for occasionally exposed workers, the dose rate of 0.65 ± 0.02 mSv y-1 is lower than recommended limit of 1 mSv y-1 for public.

The effect of sensitive and non-sensitive parameters on DCGL in probability analysis for decommissioning of nuclear facilities

  • Hyung-Woo Seo;Hyein Kim
    • Nuclear Engineering and Technology
    • /
    • 제55권10호
    • /
    • pp.3559-3570
    • /
    • 2023
  • In the decommissioning of nuclear facilities, Derived Concentration Guideline Level (DCGL) derivation is necessary for the release of the facility after the site remediation, which also needs to be implemented in the stage of establishing a decommissioning planning. In order to derive DCGL, the dose assessment for the receptors can be conducted from residual radioactivity by using RESRAD code. When performing sensitivity analysis on probabilistic parameters, secondary evaluation is performed by assigning a single value for parameters classified as sensitive. However, several options may arise in the handling of nonsensitive parameters. Therefore, we compared the results of the first execution of RESRAD applying probabilistic parameters for each scenario with the results of the second execution applying a single value to sensitive parameters among the probabilistic parameters. In addition, we analyzed the effect of setting options for non-sensitive parameters. As a result, the effect on DCGL were different depending on the application scenario, the target radionuclides, and the input parameter selections. In terms of the overall evaluation period, the DCGL graph of the default option was generally shown as the most conservative except for some radionuclides. However, it will not necessarily be given priority in the aspect of the need to reflect site characteristics. The reason for selecting a probabilistic parameter is the availability of the parameter and the uncertainty of applying a single value. Therefore, as an alternative, it can be consistently applied to distribution as an option for non-sensitive parameters after sensitivity analysis.