• Title/Summary/Keyword: Radio Transceiver

Search Result 142, Processing Time 0.028 seconds

A 3~5 GHz Interferer Robust IR-UWB RF Transceiver for Data Communication and RTLS Applications (간섭 신호에 강인한 특성을 갖는 데이터 통신과 위치 인식 시스템을 위한 3~5 GHz 대역의 IR-UWB RF 송수신기)

  • Ha, Jong Ok;Park, Myung Chul;Jung, Seung Hwan;Eo, Yun Seong
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.1
    • /
    • pp.70-75
    • /
    • 2014
  • This paper presents a IR-UWB(Impulse Radio Ultra-Wide Band) transceiver circuit for data communication and real time location system. The UWB receiver is designed to OOK(On-Off Keying) modulation for energy detection. The UWB pulse generator is designed by digital logic. And the Gaussian filter is adopted to reject side lobe in transmitter. The measured sensitivity of the receiver is -65 dBm at 4 GHz with 1 Mbps PRF(Pulse Repetition Frequency). And the measured energy efficiency per pulse is 20.6 pJ/bit. The current consumption of the receiver and transmitter including DA is 27.5 mA and 25.5 mA, respectively, at 1.8 V supply.

A Study on a Radio System for Lifesaving in Case of a Falling Accident of the Sea (해상추락 인명구조용 무선시스템에 관한 연구)

  • Choi, Byung-Ha;Kim, Gu-Chol
    • Journal of Advanced Navigation Technology
    • /
    • v.6 no.1
    • /
    • pp.62-68
    • /
    • 2002
  • Mother ship must be able to know accident occurrence information rapidly to rescue crew who fall in sea. In this paper, designed and manufactured transceiver of prescribed 447 MHz is operating as low power radio station specified in Radio Regulation. So, it is available without special permission proceedings getting form probation so that the use of this system may be easy. the system has been started for operation when the sensor get in touch with water. The system transmits with modulation by 500Hz square wave, and the receiver alarms when the transmitted signal is received. Therefore, the system can be used for not only saving a life, but also for low speed of data transmission below 2,400 bps, and other purposes.

  • PDF

Design and simulation of a rectangular planar printed circuit board coil for nuclear magnetic resonance, radio frequency energy harvesting, and wireless power transfer devices

  • Mostafa Noohi;Adel Pourmand;Habib Badri Ghavifekr;Ali Mirvakili
    • ETRI Journal
    • /
    • v.46 no.4
    • /
    • pp.581-594
    • /
    • 2024
  • In this study, a planar printed circuit board (PCB) coil with FR4 substrate was designed and simulated using the finite element method, and the results were analyzed in the frequency domain. This coil can be used in wireless power transfer (WPT) as a transmitter or receiver, eliminating wires. It can also be used as the receiver in radio frequency energy-harvesting (RF-EH) systems by optimizing the planar PCB coil to convert radio-wave energy into electricity, and it can be employed as an excitation (transmitter) or receiver coil in nuclear magnetic resonance (NMR) spectroscopy. This PCB coil can replace the conventional coil, yielding a reduced occupied volume, a fine-tuned design, reduced weight, and increased efficiency. Based on the calculated gain, power, and electromagnetic and electric field results, this planar PCB coil can be implemented in WPT, NMR spectroscopy, and RF-EH devices with minor changes. In applications such as NMR spectroscopy, it can be used as a transceiver planar PCB coil. In this design, at frequencies of 915 MHz and 40 MHz with 5 mm between coils, we received powers of 287.3 μW and 480 μW, respectively, which are suitable for an NMR coil or RF-EH system.

Implementation of a Medical Information Transmission Protocol Based on Mobile Wireless Communication (무선 이동통신 기술에 기반한 의료 정보 전송 프로토콜 구현)

  • 정희창;한민수
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.1
    • /
    • pp.19-24
    • /
    • 1998
  • The main goal of this paper is to propose and to test a radio protocol based CSMA/CA (Carrier Sense Multiple Access with Collision Avoidance) for the purpose of enhancing the existing medical information system. The feature of the new medical information system, Medical Application Radio System(MARS), which operating in real time is the transmission of medical information in bi-direction between the hospital control office and patients mobile stations. MARS monitors patients linked to the network by radio and provides quick alarm, flexible documentation capabilities, asnd fast treatment for the analysis of collected medical data. The existing medical information system, radio telemetry system which transfers the message of patients to the CAP(Central Access Point) unit in one way at the speed of 9.6Kbps and operates a channel frequency bandwidth. To verify the Performance of the proposed system, we have performed the numerical analysis and have implemented a test system which consists of the 2.4Ghz radio transceiver and personal computer.

  • PDF

Voice Communication Performance in 900MHz ISM Band Using Codec2 (Codec 2를 이용한 900MHz ISM대역에서의 음성 통신 성능 검토)

  • Kim, Gyeong-Jin;Kim, Jeong-Uk
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.23 no.6
    • /
    • pp.59-66
    • /
    • 2018
  • In this paper, we experimented how long distance voice communication is possible After implemented PTT(Push to talk) Bi-directional radio using open source project Codec 2, which is a low speed voice codec for digital amateur radio and 900MHz FSK transceiver. In case of a general digital radio, the AMBE+2 codec, which is regarded as an industry standard in terms of performance, is expensive and has the monopoly of technology. Using the 400MHz band in terms of frequency, narrow bandwidth of DMR(12.5kHz) and DPMR(6.25kHz) is used, so the data rate is low. In the 900MHz bandwidth can be extended, which is advantageous in terms of data transmission. As a result of the voice quality and distance field test, we could find that the communication takes place within about 500m. In this paper, only voice communication is reviewed. if a review of data transmission such as a simple image is added, this solution can be used in various fields as a low cost IOT radio.

A Study on the Effect and Countermeasures for Radio Wave Interference between LTE-Maritime Radio Facilities and Maritime Radio Service Facilities (초고속 해상무선통신망 무선설비와 해상업무용 무선설비간 전파 간섭 영향 및 대책 연구)

  • Jeong-Hun Lee;Hyung-Jin Moon;Bu-Young Kim;Woo-Seong Shim
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2021.11a
    • /
    • pp.119-120
    • /
    • 2021
  • Radio equipment for maritime service and navigation aids installed on fishing vessels are required to comply with the performance standards KN60945_60533 that apply IEC 60945. The LTE-M transceiver was excluded from the target because it did not belong to the radio equipment of the ship station, and it acted as a cause of audible noise in the radio equipment for maritime service installed in the fishing vessel due to interference by radiated emission or conducted emission. In this paper, we analyze the impact of interference based on related cases and present institutional solutions for the diversification of LTE-M.

  • PDF

An impulse radio (IR) radar SoC for through-the-wall human-detection applications

  • Park, Piljae;Kim, Sungdo;Koo, Bontae
    • ETRI Journal
    • /
    • v.42 no.4
    • /
    • pp.480-490
    • /
    • 2020
  • More than 42 000 fires occur nationwide and cause over 2500 casualties every year. There is a lack of specialized equipment, and rescue operations are conducted with a minimal number of apparatuses. Through-the-wall radars (TTWRs) can improve the rescue efficiency, particularly under limited visibility due to smoke, walls, and collapsed debris. To overcome detection challenges and maintain a small-form factor, a TTWR system-on-chip (SoC) and its architecture have been proposed. Additive reception based on coherent clocks and reconfigurability can fulfill the TTWR demands. A clock-based single-chip infrared radar transceiver with embedded control logic is implemented using a 130-nm complementary metal oxide semiconductor. Clock signals drive the radar operation. Signal-to-noise ratio enhancements are achieved using the repetitive coherent clock schemes. The hand-held prototype radar that uses the TTWR SoC operates in real time, allowing seamless data capture, processing, and display of the target information. The prototype is tested under various pseudo-disaster conditions. The test standards and methods, developed along with the system, are also presented.

Design of RF Energy Detector for Spectrum Sensing in TV White Space Transceiver (TV White Space 송수신기의 스펙트럼 센싱을 위한 RF 에너지 검출 회로 설계)

  • Kim, Jong-Sik;Shin, Hyun-Chol
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.11 no.2
    • /
    • pp.83-91
    • /
    • 2012
  • An RF energy detector for spectrum sensing in TV white space transceiver is presented. It is based on an RF active filtering technique that comprises a low-noise amplifier with a frequency-translation high-pass filtering feedfoward loop, which attenuates the unwanted sideband energy and only passes the wanted band energy. Unlike the conventional architecture, a new architecture that can attenuate both sidebands at the same time is proposed. A simplified system modeling method is presented to assess the non-ideality effects on the RF energy detector performances. System behavioral simulations demonstrate that the proposed architecture can be instrumental for realizaing a RF energy detector circuit in CMOS.

A New Automatic Compensation Circuit for Low Noise Amplifiers (저잡음 증폭기를 위한 새로운 자동 보상 회로)

  • Ryu, Jee-Youl;Deboma, Gilbert D.;Noh, Seok-Ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • v.9 no.1
    • /
    • pp.995-998
    • /
    • 2005
  • This paper proposes a new SoC (System-on-Chip)-based automatic compensation circuit (ACC) for 5GHz low noise amplifier (LNA). This circuit is extremely useful for today's RF IC (Radio Frequency Integrated Circuit) devices in a complete RF transceiver environment. The circuit contains RF BIST (Built-ln Self-Test) circuit, Capacitor Mirror Banks (CMB) and digital processing unit (DPU). The ACC automatically adjusts performance of 5GHz LNA by the processor in the SoC transceiver when the LNA goes out of the normal range of operation.

  • PDF

RF Characteristics of TO-can Packaged FP-LD Optical Transceiver Module (TO-can 패키지 레이저 다이오드 모듈의 주파수 특성 개선)

  • 이동수
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.4
    • /
    • pp.8-12
    • /
    • 2003
  • Characteristics of optical transceiver module in radio frequency(RF) band were investigated with TO-can packaged Fabry-Perot laser diode(FP-LD). R-L-C parameters for equivalent circuit model of the LD were extracted with an impedance analyzer. With this model, impedance matching to the packaged LD could be performed by eliminating inductive components of the leads in the package by using lumped chip capacitors that have opposite reactance, while it shows resonance dip in low frequency band. The resonance dip could be removed using lumped elements for impedance matching by shifting the resonance frequency to the region out of interest.