• 제목/요약/키워드: Radical removal

검색결과 212건 처리시간 0.024초

저온 플라즈마와 첨가제를 이용한 NOx 제거실험 및 수치해석 (The Study of NOx Removal Experiment and Numerical Analysis Modeling using Chemical Addition with Non-thermal Plasma)

  • 채재우;문승일;김관영;김상우;박용광;이창민
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 추계학술대회논문집B
    • /
    • pp.720-725
    • /
    • 2000
  • To remove harmful gases from combustion exhaust gases. fundamental study on NOx removal using pulse corona discharge has been performed through experiments and simulations. The energy consumption should be decreased in order to apply non-thermal plasma technology to industry process. This work summarized the effects of $H_2O$ and Hydrocarbon additive in NOx removal efficiency. The Radical program is used to simulate high voltage discharge and the process of NOx removal. At last, experimental results were compared with simulation results to verify the reliability of this program.

  • PDF

화학적 산화법에 의한 부식산의 분해 처리기술에 관한 연구(I) - 광산화공정을 통한 부식산의 분해특성 분석 - (Characterization of Humic Acid in the Chemical Oxidation Technology(I) - Characteristics by Photocatalytic Oxidation Process -)

  • 김종부;이동석
    • 분석과학
    • /
    • 제13권2호
    • /
    • pp.234-240
    • /
    • 2000
  • 수질계의 부식산을 화학적 산화처리하기 위한 방법의 하나로 광산화공정을 도입하여 부식산의 특성 변화를 조사하였다. 광산화공정은 UV단독, UV/$TiO_2$ 및 UV/$H_2O_2$ 시스템을 실험하였다. UV 단독 조사시 TOC 제거율은 pH 7-9에서 가장 높았으며, 흡광도는 강알카리성 영역에서 감소율이 향상된 결과를 보였다. 각 시스템별로 처리도를 보면, UV/$TiO_2$ 시스템의 경우 $TiO_2$ 의 농도가 50ppm 일때 TOC 제거와 흡광도 감소의 효율이 높았으며 50ppm 이상을 투입해도 처리율에 변화가 없었다. UV/$H_2O_2$ 시스템에서는 과산화수소의 농도가 20mM이 최적의 주입농도로 조사되었으며, 그 이상 투입할 경우 TOC와 흡광도의 처리율이 저하되었다. 탄산이온을 첨가할 경우, TOC 제거율 및 UV 흡광도의 감소율 모두 감소하며, TOC 제거율이 흡광도 감소율에 비해 상대적으로 더 크게 나타났다.

  • PDF

나노영가철/활성탄 입자전극과 과황산을 이용한 3차원 전기화학적 산화공정 (Three-dimensional Electrochemical Oxidation process using Nanosized Zero-valent Iron/Activated carbon as Particle electrode and Persulfate)

  • 민동준;김철용;안준영;조수빈;황인성
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제23권6호
    • /
    • pp.104-113
    • /
    • 2018
  • A three-dimensional electrochemical process using nanosized zero-valent iron (NZVI)/activated carbon (AC) particle electrode and persulfate (PS) was developed for oxidizing pollutants. X-ray diffraction (XRD), scanning electron microscopy with energy dispersive spectroscopy (SEM-EDS), and Brunauer-Emmett-Teller (BET) surface area analysis were performed to characterize particle electrode. XRD and SEM-EDS analysis confirmed that NZVI was impregnated on the surface of AC. Compared with the conventional two-dimensional electrochemical process, the three-dimensional particle electrode process achieved three times higher efficiency in phenol removal. The system with current density of $5mA/cm^2$ exhibited the highest phenol removal efficiency among the systems employing 1, 5, and $10mA/cm^2$. The removal efficiency of phenol increased as the Fe contents in the particle electrode increased. The particle electrode achieved more than 70% of phenol removal until it was reused for three times. The sulfate radical played a predominant role in phenol removal according to the radical scavenging test.

BDD 전극을 이용한 OH 라디칼 생성과 염료 분해에 미치는 운전인자의 영향 (Effects of Operating Parameters on Electrochemical Degradation of Rhodamine B and Formation of OH Radical Using BDD Electrode)

  • 박영식;김동석
    • 한국환경과학회지
    • /
    • 제19권9호
    • /
    • pp.1143-1152
    • /
    • 2010
  • The purpose of this study is to degradation of Rhodamine B (RhB, dye) and N, N-Dimethyl-4-nitrosoaniline (RNO, indicator of the electro-generation of OH radical) in solution using boron doped diamond (BDD) electrode. The effects of applied current (0.2~1.0 A), electrolyte type (NaCl, KCl, and $Na_2SO_4$) and electrolyte concentration (0.5~3.0 g/L), solution pH (3~11) and air flow rate (0~4 L/min) were evaluated. Experimental results showed that RhB and RNO removal tendencies appeared with the almost similar thing, except of current. Optimum current for RhB degradation was 0.6 A, however, RNO degradations was increased with increase of applied current. The RhB and RNO degradation of Cl type electrolyte were higher than that of the sulfate type. The RhB and RNO degradation were increased with increase of NaCl concentration and optimum NaCl dosage was 2.5 g/L. The RhB and RNO concentrations were not influenced by pH under pH 7. Optimum air flow rate for the oxidants generation and RhB and RNO degradation were 2 L/min. Initial removal rate of electrolysis process was expressed Langmuir - Hinshelwood equation, which is used to express the initial removal rate of UV/$TiO_$2 process.

자외선 및 초음파 공정에 의한 수용액 상의 PCBs 분해 (Removal of PCBs in Aqueous Phase in Ultraviolet (UV), Ultrasonic (US), and UV/US Processes)

  • 이덕영;손영규
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제26권4호
    • /
    • pp.1-7
    • /
    • 2021
  • The removal of PCBs (Polychlorinated biphenyls) in aqueous phase was investigated in the ultraviolet (UV) process, ultrasonics (US) process and ultraviolet/ultrasonic (UV/US) process using PCB No.7 and Aroclor 1260. For PCB No.7 relatively high removal efficiency over 90% was obtained during 20 min in the UV process and UV/US process. On the other hand, lower removal efficiency of 50 - 70% was achieved for it consisted of individual congeners of PCBs containing 3~8 of chlorine atom. It was found that the dechlorination reaction (the photolytic cleavage of C-Cl bond) was considered as a main removal mechanism in the UV process while PCBs were removed by cavitation-induced radical reaction in the US process. No significant dechlorination occurred in the US process. Consequently, it was suggested that the UV process or UV/US process was applicable for the removal of PCBs in aqueous phase in terms of the removal efficiency and operation time. In addition, the application of saturating gas such as Ar and Air could be considered to control redox condition and enhance the severity of acoustic cavitation for the removal of PCBs.

ORGANIC POLLUTANTS DEGRADATION USING PULSELESS CORONA DISCHARGE: APPLICATION IN ULTRAPURE WATER PRODUCTION

  • Shin, Won-Tae;Sung, Nak-Chang
    • Environmental Engineering Research
    • /
    • 제10권3호
    • /
    • pp.144-154
    • /
    • 2005
  • The use of ozone gained acceptance in the production of ultrapure water because of its powerful oxidizing ability. Ozone is currently used to deactivate microorganisms and remove organic contaminants. However, interest also exists in using radical species, which arc stronger oxidants than ozone, in such processes. One means of producing radical species is by corona discharge. This work investigates the use of a novel pulseless corona-discharge system for the removal of organic substances in ultrapure water production. The method combines corona discharge with electrohydrodynamic spraying of oxygen, forming microbubbles. Experimental results show that pulseless corona discharge effectively removes organics, such as phenol and methylene blue, in deionized water. The corona-discharge method is demonstrated to be comparable to the direct use of ozone at a high-applied voltage. The results also show that a minimum applied voltage exists for operation of the corona-discharge method. In this work, the minimum applied voltage is approximately 4.5 kV. The kinetic rate or phenol degradation in the reactor is modeled. Modeling results show that the dominant species of the pulseless corona-discharge reactor are hydroxyl radical and aqueous electron. Several radical species produced in the pulseless corona-discharge process are identified experimentally. The. major species are hydroxyl radical, atomic hydrogen species, and ozone.

하공정맥에 종양혈전을 동반한 신세포암 -수술 치험 2례- (Renal Cell Carcinoma Extending into IVC: 2 surgical cases)

  • 박형주
    • Journal of Chest Surgery
    • /
    • 제23권2호
    • /
    • pp.390-395
    • /
    • 1990
  • Renal cell carcinoma frequently extends into the vena cava and occasionally, even into the right atrium. We experienced 2 cases of renal cell carcinoma extending into the inferior vena cava by radical nephrectomy and complete removal of thrombi in the cava by joint approach with urologic surgeons. In the literature, improvement of survival by complete removal of tumor thrombi in the vena cava was documented and joint approach of cardiovascular surgeons and urologic surgeons result in appropriate surgical approach.

  • PDF

불용성 전극의 Dye 제거 성능과 산화제 생성 비교 (Comparison of Dye Removal Performance and Oxidants Formation of Insoluble Electrode)

  • 유영억;김동석
    • 한국환경과학회지
    • /
    • 제20권10호
    • /
    • pp.1273-1284
    • /
    • 2011
  • The aim of this research was to evaluate the performance of insoluble electrode for the purpose of degradation of Rhodamine B (RhB) and oxidants generation [N,N-Dimethyl-4-nitrosoaniline (RNO, indicator of OH radical), $O_3$, $H_2O_2$, free Cl, $ClO_2$)]. Methods: Four kinds of electrodes were used for comparison: DSA (dimensional stable anode; Pt and JP202 electrode), Pb and boron doping diamond (BDD) electrode. The effect of applied current (0.5~2.5 A), electrolyte type (NaCl, KCl and $Na_2SO_4$) and electrolyte concentration (0.5~3.5 g/L) on the RNO degradation were evaluated. Experimental results showed that the order of RhB removal efficiency lie in: JP202 > Pb > BDD ${\fallingdotseq}$ > Pt. However, when concerned the electric power on maintaining current of 1 A during electrolysis reaction, the order of RhB removal efficiency was changed: JP202 > Pt ${\fallingdotseq}$ Pb > BDD. The total generated oxidants ($H_2O_2$, $O_3$, free Cl, $ClO_2$) concentration of 4 electrodes was Pt (6.04 mg/W) > JP202 (4.81 mg/W) > Pb (3.61 mg/W) > BDD (1.54 mg/W), respectively. JP202 electrode was the best electrode among 4 electrodes from the point of view of performance and energy consumption. Regardless of the type of electrode, RNO removal of NaCl and KCl (chlorine type electrolyte) were higher than that of the $Na_2SO_4$ (sulfuric type electrolyte) RNO removal. Except BDD electrode, RhB degradation and creation tendency of oxidants such as $H_2O_2$, $O_3$, free Cl and $ClO_2$, found that do not match. RNO degradation tendency were considered a simple way to decide the method which is simple it will be able to determinate the electrode where the organic matter decomposition performance is superior. As the added NaCl concentration was increases, the of hydrogen peroxide and ozone concentration increases, and this was thought to increase the quantity of OH radical.

Functional recovery after radical prostatectomy for prostate cancer

  • Ko, Young Hwii
    • Journal of Yeungnam Medical Science
    • /
    • 제35권2호
    • /
    • pp.141-149
    • /
    • 2018
  • With the enthusiasm regarding robotic application in radical prostatectomy in accordance with the widespread use of serum prostate-specific antigen as a screening test, the number of surgeries performed for complete removal of the gland is increasing continuously. However, owing to the adjacent anatomical location of the prostate to the nerve and urethral sphincter complex, functional recovery, namely improvement from post-prostatectomy incontinence (PPI) and post-prostatectomy erectile dysfunction, still remains a main problem for patients who are reluctant to undergo surgery and tend to choose alternative ways instead. Since the late 1980s, the introduction of radical prostatectomy by open surgical modalities, the depth of the anatomical understanding of the structure surrounding the prostate is getting tremendous, which leads to the development of new surgical modalities and techniques that are consequently aimed at reducing the incidences of PPI and erectile dysfunction. Briefly, recent data from robotic radical prostatectomy, particularly on PPI, are quite acceptable, but by contrast, the reported potency regain rate still remains <20%, which indicates the need for advanced surgical modification to overcome it. In this review, the authors summarized the recent findings on the anatomy and surgical techniques reported up to now.

염소 또는 오존을 이용한 항생제 내성 유전오염물질 제어 (The Antibiotic Resistant Gene Pollutant Controls using Chlorine or Ozone disinfection)

  • 김성표;유대환;오준식;조윤철
    • 한국습지학회지
    • /
    • 제13권3호
    • /
    • pp.697-705
    • /
    • 2011
  • 본 연구의 목적은 다제 항생제 내성특성을 가진 pB10을 함유한 Escherichia coli DH 5 alpha,(E.coli $DH5{\alpha}$)를 대상 미생물로 하여 염소와 오존의 살균효율을 비교하는 것이다. 또한 다제 내성플라스미드 pB10에 대한 염소와 오존에 의한 제거율을 조사하였다. 주입농도 대비 오존살균이 염소살균에 비해 약 1.2~1.4 배 정도 효율이 높게 나타났다. 또한 다제 내성플라스미드 pB10에 대한 제거 실험에서 오존에 의한 제거율이 염소보다 약 2~4배 높게 나타났다. 오존살균에 의한 높은 pB10 제거효율은 오존 살균시 발생하는 OH 라디칼에 의한 것으로 사료된다. 이러한 연구결과로부터 내성균 및 유전물질을 효과적으로 제어하기 위하여 기존 염소살균법에 오존 또는 광촉매산화와 같은 고급산화법을 연계처리에 대한 필요가 있을 것으로 판단된다.