• 제목/요약/키워드: Radiational characteristics

검색결과 13건 처리시간 0.029초

자연환기와 복사냉방을 병용한 하이브리드 시스템의 제안 (A Proposal of Hybrid Cooling System Coupled with Radiation Panel Cooling and Natural Ventilation)

  • 송두삼
    • 설비공학논문집
    • /
    • 제15권6호
    • /
    • pp.543-550
    • /
    • 2003
  • In order to saving the energy for HVAC system of buildings, utilization of wind-induced cross ventilation is thought to be promising. However, utilization of natural ventilation alone is not sufficient for maintaining the human thermal-comfort such as in hot and humid regions. A hybrid air conditioning system with a controlled natural ventilation system, or combination of natural ventilation with mechanical air conditioning is thought to overcome the deficiency of wind-driven cross ventilation and to have significant effects on energy reduction. This paper describes a concept of hybrid system and propose a new type of hybrid system using radiational cooling with wind-induced cross ventilation. Moreover, a radiational cooling system is compared with an all-air cooling system. The characteristics of the indoor environment will be examined through CFD (Computational Fluid Dynamics) simulation, which is coupled with a radiation heat transfer simulation and with HVAC control in which the PMV value for the human model in the center of the room is controlled to attain the target value.

능동제어를 이용한 스피커 지향성의 방사특성 (Radiational characteristics of speaker directivity using active control)

  • 이채봉;이창영
    • 한국전자통신학회논문지
    • /
    • 제7권1호
    • /
    • pp.27-31
    • /
    • 2012
  • 본 논문에서는 FXLMS(Filtered-X LMS) 알고리즘을 이용하여 지향성을 가진 배열의 스피커 시스템을 구축하고 그 방사특성을 확인하였다. 배면 위치한 스피커에서 제어대상 신호의 $180^{\circ}$ 특성에 대하여 최적화 된 필터계수에 의해 제어신호를 발생시켜 제어스피커 $0^{\circ}$ 방향 특성을 간섭시켜 제어스피커 정면 $0^{\circ}$ 특성의 억제를 하도록 하였다. 이 시스템을 이용하여 장착된 배면 스피커 배열의 방사특성을 측정하였으며 제어대상 스피커의 신호가 감쇄효과를 나타나는 것을 확인하였다. 감쇄시 적응필터계수를 이용하여 배면위치 스피커의 주파수특성과 방사특성을 구한 결과, 제어점에 있어서의 감쇄는 모든 주파수 영역에서 확인되었다. 100Hz, 200Hz, 1000Hz에서의 주파수대역에서는 정면에서 $60^{\circ}{\sim}100^{\circ}$의 범위에서 감쇄효과가 나타났다.

음향인텐시티법에 의한 고체진동 가진판의 소음원 검출에 관한 연구 (A study of noise source identification on plate excited structure borne sound by acoustic intensity method)

  • 오재응;김상헌;홍동표;이찬홍
    • 오토저널
    • /
    • 제8권4호
    • /
    • pp.43-55
    • /
    • 1986
  • 소음저감에 대한 연구에서 소음언을 규명하기 위해서 소음의 발생 메카니즘을 안다는 것은 중요 하다. 구조물의 진동과 이로 인해서 발생되는 방사음과의 관계는 상당히 복잡하기 때문에 본 연 구에서는 음향인텐시티의 측정을 위하여 간단한 방사 모델을 대해 연구하였다. 소음원 규명의 첫 단계로서 본 연구에서는 음압측정에 의한 소음평가에 대해 알아 보았다. 두 번째 단계로서 음향 인텐시티법을 이용하여 음향 방사 모우드 패턴을 결정하였으며 음향인텐시티법이 소음원 검출에 유효함을 입증하였다. 또한 본 연구에서는 방진재 부착에 따른 음의 방사특성을 예측하고 방 진재 부착위치를 결정할 수 있었다.

  • PDF

열분해 방식에 따른 고체 커패시터의 특성연구 (A Study on the Characteristics of Solid Capacitor According to the Pyrolysis Methods)

  • 김재근;유형진;홍웅희
    • Korean Chemical Engineering Research
    • /
    • 제44권6호
    • /
    • pp.614-622
    • /
    • 2006
  • 질산망간수용액의 열분해에 의한 이산화망간 적용 $Ta/Ta_2O_5/MnO_2$ 커패시터의 특성 연구를 수행하였다. 질산망간수용액의 TG/DSC 분석을 통해 약 $230{\sim}250^{\circ}C$ 범위에서 단일상의 이산화망간이 생성되었다. 열분해 온도, 질산망간수용액의 농도, 열분해 회수를 이산화망간 고체 전해질 생성의 기초 변수로 선정하고 이에 따른 커패시터 특성을 평가하였다. 최적 조성을 기준으로 복사열분해 방식이 대류열분해 방식에 비하여 우수한 특성을 발휘하였다. 이는 복사열분해에 의해 상대적으로 구형의 작은 입자 상태의 이산화망간 입자들이 생성되고 이를 통해 미세 다공성 구조의 커패시터 소결체 내부에 균일하고 치밀한 이산화망간 고체전해질 층이 생성되는 것에서 기인하는 결과임을 확인하였다.

극저준위 콘크리트, 금속 해체방폐물의 방사선적 특성을 고려한 매립형 처분시설 방사선작업자 예비 피폭선량 평가 (Preliminary Radiation Exposure Dose Evaluation for Workers of the Landfill Disposal Facility Considering the Radiological Characteristics of Very Low Level Concrete and Metal Decommissioning Wastes)

  • 도호석;조예슬;강현구;하재철
    • 방사선산업학회지
    • /
    • 제17권4호
    • /
    • pp.509-518
    • /
    • 2023
  • The Kori Unit 1 nuclear power plant, which is planned to be dismantled after permanent shutdown, is expected to generate a large amount of various types of radioactive waste during the dismantling process. For the disposal of Very-low-level waste, which is expected to account for the largest amount of generation, the Korea Radioactive waste Agency (KORAD) is in the process of detailed design to build a 3-phase landfill disposal facility in Gyeongju. In addition, a large container is being developed to efficiently dispose of metal and concrete waste, which are mainly generated as Very low-level waste of decommissioning. In this study, based on the design characteristics of the 3-phase landfill disposal facility and the large container under development, radiation exposure dose evaluation was performed considering the normal and accident scenarios of radiation workers during operation. The direct exposure dose evaluation of workers during normal operation was performed using the MCNP computer program, and the internal and external exposure dose evaluation due to damage to the decommissioning waste package during a drop accident was performed based on the evaluation method of ICRP. For the assumed scenario, the exposure dose of worker was calculated to determine whether the exposure dose standards in the domestic nuclear safety act were satisfied. As a result of the evaluation, it was confirmed that the result was quite low, and the result that satisfied the standard limit was confirmed, and the radiational disposal suitability for the 3-phase landfill disposal facility of the large container for dismantled radioactive waste, which is currently under development, was confirmed.

반무반사실내 VHF 대역 안테나 측정환경 구현 (Quiet Zone Implementation for VHF Antenna Measurement in Semi-Anechoic Chamber)

  • 문정익
    • 전기전자학회논문지
    • /
    • 제16권4호
    • /
    • pp.290-296
    • /
    • 2012
  • 본 논문에서는 반무반사실내에서 반사체와 시간영역 측정을 이용한 반사파의 효과적인 억제 기술을 제안하고 있다. 제안한 기법을 이용하여 측정 영역상에 전기장의 균일도를 향상시켜 완전 무반사실과 유사한 안테나 측정환경을 구현할 수 있었다. 구현한 측정환경의 성능은 측정을 통하여 검증하였으며 소형 VHF대역 안테나 측정에 사용 가능할 것으로 판단된다.

음향인텐시티법을 이용한 4기통 가솔린 엔진의 소음원 검출에 관한 연구 (A study on the identification of noise sources of the 4-cylinder gasoline engine by using acoustic intensity method)

  • ;오재응;이완익;조진호
    • 오토저널
    • /
    • 제11권1호
    • /
    • pp.57-67
    • /
    • 1989
  • 본 연구에서는 음향 인텐시티법을 가솔린 엔진에 직접 적용하여, 각각의 중심주파수별 음향인텐시티 응답특성을 1/3옥타브 밴드로 구하였고, 오버올 레벨 및 최대 인텐시티레벨을 갖는 중심주파수에서의 음향 인텐시티 방사특성을 등고선 및 3차원 표시로 나타내었다. 또한 그 결 과를 분석 및 고찰하여 엔진의 중요 소음원을 검출하므로써 이 수법이 소음대책에 유효하다는 것을 검증하였다. 연구 결과, 오버올 레벨에서는 아이들링 상태의 경우 엔진 전면부에서, 2,000 rpm 상태의 경우 엔진 우측부에서 가장 높은 음향 인텐시티가 방사되었으며, 최대 인텐시티레 벨을 갖는 중심주파수에서는 오일팬과 흡, 배기매니홀드가 100Hz에서 가장 높은 음향 인텐시티를 나타내었다.

  • PDF

이층류 모델링의 교환류와 내부조석파 연구에의 적용 (Two Layer Modelling with Applications to Exchange Flow and Internal Tide)

  • Kang, Sok-Kuh;Abbott, Michael-B.;Heung, Jae-Lie;Yum, Ki-Dai
    • 한국해안해양공학회지
    • /
    • 제9권1호
    • /
    • pp.9-23
    • /
    • 1997
  • 일차원 2층 성충류에 대한 음해 유한차분법을 이용한 수치실험 연구를 실시하였다 수치방법에 대한 기본 테스트와 함께 수질실험 자료가 있는 교환류에 대한 모델결과의 검증을 실시하였다. 다양한 충간 및 해저마찰계수와 수치계산의 시간 가중인자, smoothing 인자에 대한 모델 반응 결과를 제시한다. 아울러 2층 모델을, 성충이 되어 있고 해저면 기울기가 급격한 조건에서 내부파의 발생과 전파 특성에 대한 연구에 응용하였다. 하류부 경계의 1개 층 혹은 2개 층을 방사조건으로 처리했을 때, 하류부를 통해 내부파가 잘 전파되어, 방사파 조건의 성충류 모델링에의 적용성을 확인하였다. 또한 하류부의 저층두께가 두꺼울수록 내부파가 하류부 경계를 통해 활발히 전파해 가는 것으로 나타났다. 이는 충간의 내부파 위치에너지는 상충의 두께가 일정한 경우, 하층의 두께에 좌우될 것임을 암시한다.

  • PDF

상용 의학용 X-ray 필름의 특성곡선 (The Characteristic Curves of Commercial Medical X-ray Films)

  • 허훈;정연태;이재성
    • 한국인쇄학회지
    • /
    • 제19권2호
    • /
    • pp.12-21
    • /
    • 2001
  • For the purpose of determining characteristics of widely used commercial medical x-ray films, which are used for obtaining the Linac-grams for radiational treatment of cancers, we placed several commercial x-ray films at a fixed distance form the linear accelerator. After varying the exposed amount of radiation step by step, we could obtain a continually increasing density image for each film whose densities were determined by microdensitometer readings. The characteristic curves of the films were obtained by plotting the densities vs. the exposed radiation amounts, and their ${\gamma}$ values were determined. These values can be used to suggest a minimum necessary amount of exposed radiation to get a useful Linac-gram. The measured ${\gamma}$ values of the characteristic curves of the Kodak-DVP/RA-1 film were 1.73 when used 6MV x-ray, 1.70 when used 15MV of intensity. For the Konica-AX film, ${\gamma}$ values were 1.29 and 1.18 respectively. The result suggests that the effective conditions for high resolution of a L-gram be 6 MV of x-ray intensity and about 3 rad of exposed dose on a Kodak-DVP/RA-1 film.

  • PDF

영덕군 덕산리 얼음골의 냉각 및 하계 결빙현상에 관한 연구 (A Study on Cooling and Freezing During Summer Season in Deoksan-ri Eoreumgol (ice valley) Yeongdeok-gun (South Korea))

  • 이진국;신재열;장윤득
    • 한국지역지리학회지
    • /
    • 제21권3호
    • /
    • pp.608-617
    • /
    • 2015
  • 본 연구는 영덕군 덕산리 얼음골의 발생적 특징을 파악하고 하계 결빙현상의 과정을 규명하기 위해 미기상학적 자료 분석 및 지형 발달 특성을 종합적으로 검토하고 있다. 연구지역의 얼음골은 산지 동사면 애추 지형에서 발달하고 있으며 냉각 및 하계 결빙의 강도는 애추의 형태 및 규모와 밀접한 상관이 있는 것으로 판단된다. 얼음골의 냉각은 동계 산지 정상부로부터 애추 내 암설의 공극을 통해 하단부로 이동하는 냉기류에 의해 이루어지며, 그 결과 애추 내 하단부 암설들을 과냉각시킨다. 냉각된 공기는 안정한 기층을 형성하여 외부의 공기와 순환되지 못하고 애추 지형 하단부에 정체하며 일부 유출 지점에서는 초여름까지 결빙 현상을 발생시키는 것으로 파악된다. 특히 냉기류가 유출될 때 외부 공기의 습도 및 기화열의 발생은 결빙 현상에 중요한 요인이 된다.

  • PDF