• 제목/요약/키워드: Radiation technique

검색결과 1,274건 처리시간 0.134초

X-ray properties measurement of Flat panel Digital X-ray gas detector (평판형 디지털 엑스레이 가스 검출기의 엑스선 특성 측정기술에 관한 연구)

  • Yoon, Min-Seok;Cho, Sung-Ho;Oh, Kyung-Min;Jung, Suk-Hee;Nam, Sang-Hee;Park, Ji-Goon
    • Journal of the Korean Society of Radiology
    • /
    • 제3권1호
    • /
    • pp.17-21
    • /
    • 2009
  • The Recently, large area matrix-addressed image detectors are investigated for X-ray imaging with medical diagnostic and other applications. In this paper, a new flat panel gas detector for diagnostic X-ray imaging is proposed, and its characteristics are investigated. The research of flat panel gas detector is not exist at all. Because of difficulty to inject gas against to atmospheric pressure. So almost gas detector made by chamber shape. We made flat panel sample by display technique. (ex: PDP, Fed, etc.) The experimental measurements, the transparent electrodes, dielectric layer, and the MgO protection layer were formed in front glass. And, the X-ray phosphor layer and address electrodes are formed in the rare glass. The dark current, the x-ray sensitivity and linearity as a function of electric field were measured to investigate the electrical properties. From the results, the stabilized dark current density and the significant x-ray sensitivity were obtained. And the good linearity as a function of exposure dose was showed in wide diagnostic energy range. These results means that the passive matrix-addressed flat panel gas detector can be used for digital x-ray imaging.

  • PDF

Field Application of Phased Array Ultrasonic Testing for Structural Weld Overlay on Dissimilar Welds of Pressurizer Nozzles (가압기 노즐 이종금속 용접부의 구조적 오버레이 용접부에 대한 위상배열 초음파기법의 현장 적용)

  • Kim, Jin-Hoi;Kim, Yongsik
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • 제35권4호
    • /
    • pp.268-274
    • /
    • 2015
  • Weld overlay was first used in power plants in the US in the early 1980s as an interim method of repairing the welds of flawed piping joints. Weld overlaid piping joints in nuclear power plants must be examined periodically using ultrasonic examination technology. Portable phased array ultrasonic technology has recently become available. Currently, the application of preemptive weld overlays as a mitigation technique and/as a method to improve the examination surface condition for more complex configurations is becoming more common. These complex geometries may require several focused conventional transducers for adequate inspection of the overlay, the original weld, and the base material. Alternatively, Phased array ultrasonic probes can be used to generate several inspection angles simultaneously at various focal depths to provide better and faster coverage than that possible by conventional methods. Thus, this technology can increase the speed of examinations, save costs, and reduce radiation exposure. In this paper, we explain the general sequence of the inspection of weld overlay and the results of signal analysis for some PAUT (phased array ultrasonic testing) signals detected in on-site inspections.

The Development of Water Quality Monitoring System and its Application Using Satellite Image Data

  • Jang, Dong-Ho;Jo, Gi-Ho
    • Proceedings of the KSRS Conference
    • /
    • 대한원격탐사학회 1998년도 Proceedings of International Symposium on Remote Sensing
    • /
    • pp.376-381
    • /
    • 1998
  • In this study, we was measured the radiance reflectance by using multi-spectral image of low resolution camera(LRC) which will be loaded in the multi-purpose satellite(KOMPSAT) to use the data in analyzing water pollution. Also we investigated the possibility of extraction of water quality factors in rivers and water body by using high resolution remote sensing data such as Airborne MSS. Especially, we tried to extract the environmental factors related with eutrophication, and also tried to develop the process technique and the radiance feature of reflectance related with eutrophication. The results were summarized as follows: First, the spectrum of sun's rays which reaches the surface of the earth was consistent with visible rays bands of 0.4${\mu}{\textrm}{m}$~0.7${\mu}{\textrm}{m}$ and about 50% of total quantity of radiation were there. And at around 0.5${\mu}{\textrm}{m}$ of green spectral band in visible rays bands, the spectrum was highest. Second, as a result of the radiance reflectance Chlorophyll-a represented high spectral reflectance mainly around 0.52${\mu}{\textrm}{m}$ of green spectral band, and suspended sediments and turbidity represented high spectral reflectance at 0.8${\mu}{\textrm}{m}$ and at 0.57${\mu}{\textrm}{m}$ each. Third, as a result of the water quality analysis by using Airborne MSS, Chlorophyll-a could have a distribution chart when carried out ratio of B3 and BS to B7. And Band 7 was useful for making the distribution chart of suspended sediments. And when we carried out PCA, suspended sediments and turbidity had distributions at PC 1 , PC 4 each similarly to ground truth data. Above results can be changed according to the change of season and time. Therefore, in order to analyze more exactly the environmental factors of water quality by using LRC data, we need to investigate constantly the ground truth data and the radiance feature of reflectance of water body. Afterward in this study, we will constantly analyze the radiance feature of the surface of water in water body by measuring the on-the-spot radiance reflectance and using low resolution satellite image(SeaWiFs). Besides, we will gather the data of water quality analysis in water body and analyze the pattern of water pollution.

  • PDF

Thermal and Water Transmission Properties of Vapor Permeable Water Repellent Fabrics and Thermal Insulation Batting Materials (투습발수직물과 보온단열소재의 열 및 수분전달 특성)

  • Cho Gil Soo;Choi Jong Myoung;Lee Jung Ju;Lee Sern Woo
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • 제16권2호
    • /
    • pp.237-244
    • /
    • 1992
  • The purpose of this study was to comparatively evaluate thermal and water transmission properties of several vapor permeable water repellent (VPWR) fabrics and synthetic battings that became available in recent years. Five VPWR fabrics evaluated were Hipora in three coating variants, $Gore-Tex^{\circledR}$ and $Aitace^{\circledR}$. Battings evaluated were $Viwarma^{\circledR}$, $Uniwarmr^{\circledR}$, $Thinsulate^{\circledR}$, and $Airseal^{\circledR}$ Thermal resistance and water vapor transmission were measured for each fabric and batting and in all combinations. Thermal resistance at zero and 37 cm/sec air velocity was determined by the Thermo Labo II technique for simultaneously measuring conduction and radiation heat transfer. Water vapor transmission over 24 hours was measured by a modified weight-gain method in a compact humid chamber at conditions simulating the clothing climate under heavy exercise ($40{\pm}1^{\circ}C$, $90{\pm}2\%$ R.H., and 0.5 m/sec air velocity). Fabric porosity was calculated from fiber density and fabric weight, thickness, and area. Thermal resistance results for the fabrics showed the effectiveness of coatings in inhibiting heat transfer. Measurements taken in wind were: $31.1\~37.6\%$ for $Hipora^{\circledR}$ variants; $31.0\%$ for $Gore-Tex^{\circledR}$; and $18.4\%$ for $Aitaca^{\circledR}$ Measurements without wind were higher but in the same order. Water vapor transmission results were in reverse order: $Aitac^{\circledR}$, $8.8 kg/m^{2};\;Gore-Tex^{\circledR}$, 6.4 kg/$m^{2}$; and $Hipora^{\circledR},\;4.4\~6.0\;kg/m^{2}$. In general thermal resistance increased with porosity. For battings, the thermal resistance with wind results were: $Viwarmu^{\circledR}$, $65.0\%;\; Thinsulate^{\circledR}$, $62.0\%$; $Uniwarm^{\circledR}$, $61.0\%$; and $Airseala^{\circledR},\;53.1\%$. Thermal resistance was proportional to thickness. Thermal resistance of fabric-batting combinations were $20\%$ higher than those of the battings only. Water vapor transmission for combinations was mainly affected by that for the VPWR fabric used.

  • PDF

The evaluation on the biological safety of diagnostic ultrasound using radiation-induced apoptosis in the external granular layer of mouse cerebellum (마우스 소뇌과립층의 apoptosis를 지표로 한 진단용 초음파의 안전성 검증)

  • Oh, Heon;Lee, Song-eun;Yang, Jung-ah;Jo, Sung-kee;Chung, Chi-young;Son, Chang-ho;Kim, Sung-ho
    • Korean Journal of Veterinary Research
    • /
    • 제39권3호
    • /
    • pp.628-634
    • /
    • 1999
  • We have studied, by a nonisotopic in situ end-labeling(ISEL) technique, frequency of apoptosis in the external granular layer(EGL) of the cerebellum of immature mice by ${\gamma}$-rays irradiation from $^{60}Co$ or diagnostic ultrasound exposure. The total number of normal cells and cells showing morphological features of apoptosis were counted. The frequency of apoptotic cells was expressed as a percentage of the total number of cells in EGL. The extent of changes following 200 cGy(1090 cGy/min) was studied at 2, 4, 6, 8, 12, or 24 hours after exposure. The maximal frequency was found 6~8 hours after exposure. The immature mice that received 18, 36, 54, 108, 198, 396 cGy of ${\gamma}$-rays or diagnostic ultrasound(7.5MHz, 4.2mW, $I_{SPTA}=7.9mW/cm^2$, $I_{SPTA}=114.3W/cm^2$) for 10 or 30 minutes were examined 6 hours after irradiation. Measurements performed after ${\gamma}$-ray irradiation showed a dose-related increase in apoptotic cells in each of the mice studied. The dose-response curves were analyzed by a linear-quadratic model ; frequency of apoptotic cell in the EGL was y = $(0.1349{\pm}0.01175)D$+$(-0.0001522{\pm}0.0000334)D^2$+0.048($r^2$ = 0.981, D = dose in cGy). In the experiment of ultrasound exposure, the frequency of apoptotic cell was $0.106{\pm}0.130$(10 minutes exposure) and $0.167{\pm}0.220$(30 minutes exposure). We estimated the relative dose of the yield from the experiment with ultrasound by substituting the yield from ultrasound exposure into the curve from the ${\gamma}$-irradiation. The relative dose of ultrasound exposure compared with ${\gamma}$-irradiation were 0.432 cGy(10 minutes exposure) and 0.885 cGy(30 minutes exposure). We have found that there is no evidence to indicate that diagnostic ultrasound involves a significant risk.

  • PDF

Studies on the Productive Structure and the Productivity of × Populus albaglandulosa Plantation (은수원사시나무의 조림지(造林地)의 생산구조(生産構造)와 생산성(生産性))

  • Kim, Joon Ho;Sun, Soon Hwa;Lee, Suk Koo;Kim, Chung Suk
    • Journal of Korean Society of Forest Science
    • /
    • 제35권1호
    • /
    • pp.9-14
    • /
    • 1977
  • The productive structure and the productivity of ${\times}$Populus albaglandulosa plantations, where are middle parts of the Korean peninsula, were studied by means of stratifying clip technique and of allometry. The densities of stands in the sample areas were 693 trees/ha in 6 year-old plantation and 527 or 625 trees/ha in 9 year-old one. The photosynthetic part of the productive structure was not shown normal conical form but layering. So this was efficient to transmit solar radiation into the stand floor. The standing crop of the terrestrial parts of 6 year-old plantation was 18.11 ton/ha and that of 9 year-old one 38.8 to 47.3 ton/ha. The wood volume to trunk to 6 year-old was $31.3m^3/ha$ and that of 9 year-old was 68.8 to $83.9m^3/ha$. The annual net production of 6 year-old plantation was 4.8 ton/ha/year and that of 9 year-old one was 10.0 to 11.7 ton/ha/year and its wood volume of trunks was 17.9 to $21.1m^3/ha/year$. In the 9 year-old plantation the standing crop or the annual net production was different between two sample areas. This seemed that the cause was not due to chemical character but to physical character of soil.

  • PDF

A Study on the Enhancement of Isolation of the MIMO Antenna for LTE/DCS1800/USPCS1900 Handset (LTE/DCS1800/USPCS1900 단말기용 MIMO 안테나의 격리도 개선에 관한 연구)

  • Cho, Dong-Ki;Son, Ho-Cheol;Lee, Jin-Woo;Lee, Sang-Woon;Lee, Mun-Soo
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • 제47권10호
    • /
    • pp.80-85
    • /
    • 2010
  • In this paper, a MIMO antenna is proposed for LTE/DCSl800/USPCSl900 handset applications. The proposed antenna is based on the IFA and its wide bandwidth is obtained by using a stagger tuning technique. To improve the isolation, a suspended line is connected to the shorting points in two antennas, and capacitors and inductors are added to the connected suspended line. Two identical antennas of which dimension is 2.8cc($40{\times}10{\times}7mm$) are mounted on the two end lines of the system ground plane($40{\times}60mm$). Analysis of the antenna performance and optimization is performed using CST Microwave Studio. The bandwidths are satisfied for LTE band class 13(746-787MHz), class 14(758-798MHz) and DCSl800/USPCSl900 band (1710-1990MHz). The isolations between two antennas are about -12dB for LTE band and -10dB for DCSl800/USPCSl900 band. And the radiation efficiency of each antenna is about for LTE band 33% and 45% for DCSl800/USPCSl900 band respectively.

Design and Implementation of Plannar S-DMB Antenna with Omni-Directional Radiation Pattern Using Metamaterial Technique (메타 물질 기법을 이용한 전방향성 복사 패턴을 갖는 평면형 S-DMB 안테나 설계 및 구현)

  • An, Chan-Kyu;Yu, Ju-Bong;Jeon, Jun-Ho;Kim, Woo-Chan;Yang, Woon-Geun;Nah, Byung-Ku;Lee, Jae-Ho
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • 제21권12호
    • /
    • pp.1343-1351
    • /
    • 2010
  • In this paper, a novel patch antenna based on the metamaterial CRLH(Composite Right- and Left-Handed) structure is designed, implemented, and measured. Contrary to the standard microstrip patch's fundamental resonance mode of half-wavelength or its positive multiple, the proposed antenna shows the in-phase electric field over the entire antenna. The proposed antenna has a desired omni-directional field pattern which is typical characteristic of $\lambda/4$ monopole antenna, and also shows the merit of low profile. HFSS(High Frequency Structure Simulator) of Ansoft which is based on the FEM(Finite Element Method) is used to simulate the proposed antenna. FR-4 substrate of thickness 1.6 mm and relative permitivity 4.4 is used for the proposed antenna implementation. The implemented antenna showed VSWR (Voltage Standarding Wave Ratio)$\leq$2 for the frequency band from 2.63 GHz to 2.655 GHz which is used for S-DMB (Satellite-Digital Multimedia Broadcasting) service. And measured peak gain and efficiency are 2.65 dBi and 81.14 %, respectively.

Cavity-Backed Slot Array Antenna for a Repeater System of a Satellite Digital Multimedia Broadcasting (위성 DMB 중계기용 Cavity-Backed슬롯 배열 안테나)

  • Jung Hee-Chul;Lee Hak-Yong;Jung Byungwoon;Kang Gi-Cho;Park Myun-Joo;Lee Byungje
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • 제16권4호
    • /
    • pp.366-372
    • /
    • 2005
  • This paper presents analysis of a slot array antenna having a low side lobe level and high front-to-back ratio for a repeater system of a satellite DMB(Digital Multimedia Broadcasting) service. Antennas for this repeater system require a high gain and enough isolation to reduce interferences between signals in system. Therefore, it is necessary to suppress a side lobe level and to increase front-to-back ratio. Unlike a structure 134 by lossy microstrip lines, in this work a single cavity-backed slot antenna array using a single waveguide feed is proposed to obtain the reliability for high power handling and high radiation efficiency. The side lobe level and front-to-back ratio are enhanced with tapered array technique and an optimized vertical reflector. The measured side lobe levels in H- and E-plane are under $-33.24\;\cal{dB}$ and $-35.78\;\cal{dB}$, respectively. The front-to-back ratio over $37.84\;\cal{dB}$, and the peak gain of over $17\;\cal{dBi}$ are measured.

Thermoluminescence Dating of Pottery Shards by Subtraction Method (Subtraction 방법을 이용한 TL 연대측정법에 의한 토기 시편의 절대연대 결정)

  • Shin, Hyun-Sang;Lee, Chang-Woo;Nam, Young-Mee;Jee, Kwang-Yong;Park, Byung-Bin
    • Analytical Science and Technology
    • /
    • 제13권4호
    • /
    • pp.403-411
    • /
    • 2000
  • This study described a method of thermoluminescence dating of pottery shards using subtraction method. TL measurement was achieved using two different types of samples prepared by quartz inclusion method and fine-grain technique. Fine grains (size range: $5-10{\mu}m$) were separated by suspending grounded pottery samples into acetone solution and sedimentation quantitatively. In quartz inclusion method quartz grains in the size range of 90 to $125{\mu}m$ diameter were obtained by extracting the quartz crystals embed in the pottery shards and etching them with 1.0 M HF solutions. The archaeological dose of both the quartz and fine grains was determined from the dose calibration curves obtained from sequential irradiation of $^{137}Cs$ gamma and $^{241}Am$ alpha source to the samples and TL measurement of natural samples, in which the alpha dose of 4.60 Gy for the Packjae pottery was obtained using subtraction method. Annual alpha dose rates ($3.05{\pm}0.11$ mGy/yr.) were determined by the analysis of U, Th contents in the pottery shards and evaluation of the values with Bell's equation. Dividing the alpha dose accumulated in the pottery shards by the annual alpha dose rate, we found age of approximately $1508{\pm}80$ years B.P. (AD. ca. 492 yr.) for the Packjae pottery. It matches well with the archeological age estimate (middle of 5th century) within 10 percent uncertainty and thereby conforms the age of the pottery sample.

  • PDF