• Title/Summary/Keyword: Radiation technique

Search Result 1,274, Processing Time 0.035 seconds

A study on the arrangement of actuators and speaker zones of the panel speaker (패널 스피커의 가진기 및 스피커 배치에 관한 연구)

  • Jung-Han Woo;Seong-Hyun Lee;Yun-Ho Seo;Pyung-Sik Ma;Dongjoon Kim
    • The Journal of the Acoustical Society of Korea
    • /
    • v.42 no.5
    • /
    • pp.388-394
    • /
    • 2023
  • When the vibration of the thin panel by exciting single point is used to radiate sound, the inherent vibration characteristic of the plate itself causes influence on the radiated sound. A conventional panel speaker system usually uses the single or double point excitations for generating the sound through the panel itself. The radiated sound can be easily distorted due to the modal characteristics of the plate so it is difficult to expect sufficient sound power or high radiation efficiency. In this paper, to achieve an immersive sound field, the multiple speaker zones on a thin panel are created with the limited number of actuators. The designated vibration field which can generates directional sound is realized by employing the vibro-acoustic inverse rendering methods. Actuators are arranged from the positions which have the advantage of implementing with multi-modal excitations. The location and number of actuators are compared with the location and number of controllable speaker zones by conducting numerical simulations.

A closer look at the structure and gamma-ray shielding properties of newly designed boro -tellurite glasses reinforced by bismuth (III) oxide

  • Hammam Abdurabu Thabit;Abd Khamim Ismail;N.N. Yusof;M.I. Sayyed;K.G. Mahmoud;I. Abdullahi;S. Hashim
    • Nuclear Engineering and Technology
    • /
    • v.55 no.5
    • /
    • pp.1734-1741
    • /
    • 2023
  • This work presents the synthesis and preparation of a new glass system described by the equation of (70-x) B2O3-5TeO2 -20SrCO3-5ZnO -xBi2O3, x = 0, 1, 5, 10, and 15 mol. %, using the melt quenching technique at a melting temperature of 1100 ℃. The photon-shielding characteristics mainly the linear attenuation coefficient (LAC) of the prepared glass samples were evaluated using Monte Carlo (MC) simulation N-particle transport code (MCNP-5) at gamma-ray energy extended from 59 keV to 1408 keV emitted by the radioisotopes Am-241, Ba-133, Cs-137, Co-60, Na-22, and Eu-152. Furthermore, we observed that the Bi2O3 content of the glasses had a significantly stronger impact on the LAC at 59 and 356 keV. The study of the lead equivalent thickness shows that the performance of fabricated glass sample with 15 mol.% of Bi2O3 is four times less than the performance of pure lead at low gamma photon energy while it is enhanced and became two times lower the perforce of pure lead at high energy. Therefore, the fabricated glasses special sample with 15 mol.% of Bi2O3 has good shielding properties in low, intermediate, and high energy intervals.

Percutaneous Ultrasound-Guided Fine-Needle Aspiration Cytology and Core-Needle Biopsy for Laryngeal and Hypopharyngeal Masses

  • Dongbin Ahn;Gil Joon Lee;Jin Ho Sohn;Jeong Eun Lee
    • Korean Journal of Radiology
    • /
    • v.22 no.4
    • /
    • pp.596-603
    • /
    • 2021
  • Objective: To evaluate the feasibility and diagnostic performance of ultrasound (US)-guided fine-needle aspiration cytology and core-needle biopsy (US-FNAC/CNB) for the diagnosis of laryngo-hypopharyngeal masses. Materials and Methods: This was a single-center prospective case series. From January 2018 to June 2019, we initially enrolled 40 patients with highly suspicious laryngo-hypopharyngeal masses on laryngoscopic examinations. Of these, 28 patients with the mass involving or abutting the pre-epiglottic, paraglottic, pyriform sinus, and/or subglottic regions were finally included. These patients underwent US examinations with/without subsequent US-FNAC/CNB under local anesthesia for evaluation of the laryngo-hypopharyngeal mass. Results: Of the 28 patients who underwent US examinations, a laryngo-hypopharyngeal mass was identified in 26 patients (92.9%). US-FNAC/CNB was performed successfully in 25 of these patients (96.2%), while the procedure failed to target the mass in 1 patient (3.8%). The performance of US caused minor subclinical hematoma in 2 patients (7.7%), but no major complications occurred. US-FNAC/CNB yielded conclusive results in 24 (96.0%) out of the 25 patients with a successful procedure, including 23 patients with squamous cell carcinoma (SCC) and 1 patient with a benign mass. In one patient with atypical cells in US-FNAC, additional direct laryngoscopic biopsy (DLB) was required to confirm SCC. Among the 26 patients who received US-FNAC/CNB, the time from first visit to pathological diagnosis was 7.8 days. For 24 patients finally diagnosed with SCC, the time from first visit to the initiation of treatment was 25.2 days. The mean costs associated with US-FNAC/CNB was $272 under the Korean National Health Insurance Service System. Conclusion: US-FNAC/CNB for a laryngo-hypopharyngeal mass is technically feasible in selected patients, providing good diagnostic performance. This technique could be used as a first-line diagnostic modality by adopting appropriate indications to avoid general anesthesia and DLB-related complications.

Development of numerical method to predict broadband radiation noise resulting in fluid-induced vibration and acoustic-induced vibration of pipe (배관의 유동 유발 진동 및 음향 유발 진동 기인 광대역 방사 소음 예측을 위한 수치 해석 기법 개발)

  • Sangheon Lee;Cheolung Cheong;Songjune Lee
    • The Journal of the Acoustical Society of Korea
    • /
    • v.43 no.1
    • /
    • pp.112-121
    • /
    • 2024
  • The pipping system is widely used in many industries as equipment for transporting fluids over long distances. In high-pressure pipe, as the speed of the fluid increases, a loud noise is generated. Therefore, various studies have been conducted to reduce pipe noise. In this paper, a pipe noise analysis was developed to predict and quantitatively assess the flow-induced vibration and acoustic-induced vibration due to valve flow in high-temperature and high-pressure. To do this, a high-fidelity fluid analysis technique was developed for predicting internal flow in the pipe with valve. In additional, the contribution of compressible/incompressible pressure by frequency band was evaluated using the wavenumber-frequency analysis. To predict a low/middle frequency pipe noise, the vibroacoustic analysis method was developed based on Finite Element Method (FEM). And the pipe noise prediction method for the middle/high frequency was developed based on Statistical Energy Analysis (SEA).

The Effect of PET Scan Time on the Off-Line PET Image Quality in Proton Therapy (양성자 치료에서 영상 획득 시간에 따른 Off Line PET의 효율성 검증)

  • Hong, Gun-Chul;Jang, Joon-Yung;Park, Se-Joon;Cha, Eun-Sun;Lee, Hyuk
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.2
    • /
    • pp.74-79
    • /
    • 2017
  • Purpose Proton therapy can deliver an optimal dose to tumor while reducing unnecessary dose to normal tissue as compared the conventional photon therapy. As proton beams are irradiated into tissue, various positron emitters are produced via nuclear fragmentation reactions. These positron emitters could be used for the dose verification by using PET. However, the short half-life of the radioisotopes makes it hard to obtain the enough amounts of events. The aim of this study is to investigate the effect of off-line PET imaging scan time on the PET image quality. Materials and Methods The various diameters of spheres (D=37, 28, 22 mm) filled with distilled water were inserted in a 2001 IEC body phantom. Then proton beams (100 MU) were irradiated into the center of the each sphere using the wobbling technique with the gantry angle of $0^{\circ}$. The modulation widths of the spread out bragg peak were 16.4, 14.7 and 9.3 cm for the spheres of 37, 28 and 22 mm in diameters respectively. After 5 min of the proton irradiation, the PET images of the IEC body phantom were obtained for 50 min. The PET images with different time courses (0-10 min, 11-20 min, 21-30 min, 31-40 min and 41-50 min) were obtained by dividing the frame with a duration of 10 min. In order to evaluate the off-line PET image quality with the different time courses, the contrast-to-noise ratio (CNR) of the PET image calculated for each sphere. Results The CNRs of the sphere (D=37 mm) were 0.43, 0.42, 0.40, 0.31 and 0.21 for the time courses of 0-10 min, 11-20 min, 21-30 min, 31-40 min and 41-50 min respectively. The CNRs of the sphere (D=28 mm) were 0.36, 0.32, 0.27, 0.19 and 0.09 for the time courses of 0-10 min, 11-20 min, 21-30 min, 31-40 min and 41-50 min respectively. The CNR of 37 mm sphere was decreased rapidly after 30 min of the proton irradiation. In case of the spheres of 28 mm and 22 mm, the CNR was decreased drastically after 20 min of the irradiation. Conclusion The off-line PET imaging time is an important factor for the monitoring of the proton therapy. In case of the lesion diameter of 22 mm, the off-line PET image should be obtained within 25 min after the proton irradiation. When it comes to small size of tumor, the long PET imaging time will be beneficial for the proton therapy treatment monitoring.

  • PDF

Dose Distribution of Intensity Modulated Radiation Therapy in Prostate Cancer (전립선암에서 세기조절방사선치료의 선량분포 특성)

  • Kim, Sung-Kyu;Choi, Ji-Hoon;Yun, Sang-Mo
    • Progress in Medical Physics
    • /
    • v.21 no.3
    • /
    • pp.298-303
    • /
    • 2010
  • The aim of this study was to compare the dose distribution of intensity modulated radiation therapy (IMRT) with 3 dimensional conformal radiation therapy (3DCRT) in prostate cancer. The IMRT plan and the 3DCRT plan used the 9 fields technique, respectively. In IMRT, tumor dose was a total dose of 66 Gy at 2.0 Gy per day, 5 days a week for 5 weeks. All cases were following the dose volume histogram (DVH) constraints. The maximum and minimum tumor dose constraints were 6,700 cGy and 6,500 cGy, respectively. The rectum dose constraints were <35% over 50 Gy. The bladder dose constraints were <35% over 40 Gy. The femur head dose constraints were <15% over 20 Gy. Tumor dose in the 3DCRT were 66 Gy. In IMRT, the maximum dose of PTV was 104.4% and minimum dose was 89.5% for given dose. In 3DCRT, the maximum dose of PTV was 105.3% and minimum dose was 85.5% for given dose. The rectum dose was 34.0% over 50 Gy in IMRT compared with 63.3% in 3DCRT. The bladder dose was 30.1% over 40 Gy in IMRT compared with 30.6% in 3DCRT. The right femur head dose was 9.5% over 20 Gy in IMRT compared with 17.5% in 3DCRT. The left femur head dose was 10.6% over 20 Gy in IMRT compared with 18.3% in 3 DCRT. The dose of critical organs (rectum, bladder, and femur head) in IMRT showed to reduce than dose of 3DCRT. The rectum dose over 50 Gy in IMRT was reduced 29.3% than 3DCRT. The bladder dose over 40 Gy in IMRT was similar to 3DCRT. The femur head dose over 20 Gy in IMRT was reduced about 7~8% than 3DCRT.

Accelerated Fractionation In The Treatment of Brain Metastasis From Non-Small Cell Carcinoma of The Lung (비소세포성 폐암환자의 뇌전이에 대한 급속분할조사법)

  • Hong, Seong-Eon
    • Radiation Oncology Journal
    • /
    • v.12 no.2
    • /
    • pp.165-173
    • /
    • 1994
  • Purpose : Metastatic cancer to the brain is a major problem for the patients with bronchogenic carcinoma, and most of these patients have a limited survival expectancy. To increase tumor control and / or to decrease late morbidity with possible shortening in over-all treatment period, multiple daily fraction technique for brain metastasis was performed. The author reperesented the results of accelerated fractionation radiotherapy in patients with brain metastases from non-small cell lung cancer. Materals and Methods : Twenty-six patients with brain metastases from non-small cell lung cancer between 1991 and 1993 received brain radiotherapy with a total dose of 48 Gy, at 2 Gy per fraction, twice a day with a interfractional period of 6 hours, and delivered 5 days a week. The whole brain was treated to 40 Gy and boost dose escalated to 8 Gy for single metastatic lesion by reduced field. Twenty-four of the 26 patients completed the radiotherapy. Radiotherapy was interupted in two patients suggesting progressive intracerebral diseases. Results : This radiotherapy regimen appears to be comparable to the conventional scheme in relief from symptoms. Three of the 24 patients experienced nausea and or vomiting during the course of treatment because of acute irradiation toxicity. The author observed no excessive toxicity with escalating dose of irradiation. An increment in median survival, although not statistically significant(p>0.05), was noted with escalating doses(48 Gy) of accelerated fractionation(7 months) compared to conventional treatment(4.5 months). Median survival also increased in patients with brain solitary metastasis(9 months) compared to multiple extrathoracic sites(4 months), and in patients with good performance status(9 months versus 3.5 months), they were statistically significant (p<0.01). Conclusion : The increment in survival in patients with good prognostic factors such as controlled primary lesion, metastasis in brain only and good perfomance status appeared encouraging. Based on these results, a multi-institutional prospective randomized trial should be initiated to compare the twice-a-day and once-a-day radiotherapy schemes on patients with brain metastasis with careful consideration for the patients' quality of life.

  • PDF

Application of the Equivalent-Field Method for Output Calculation: Is it safe for elongated x-ray fields\ulcorner (출력인자 계산에 이용되는 등가면법의 타당성 연구 : 장방형 X-선 조사면에 대해서 안전한가\ulcorner)

  • Kim, Chang-Seon;Kim, Chul-Yong;Park, Myung-Sun
    • Progress in Medical Physics
    • /
    • v.9 no.4
    • /
    • pp.195-200
    • /
    • 1998
  • Purpose: When an elongated x-ray field is used for treating a patient, the equivalent- field method is commonly used for the output calculation. This study is intended for investigating potential factors such as, beam quality, field elongation ratio, and depth of measurement, which might effect on the applicability of the equivalent square technique for output calculation. The derivation of a 'rule of thumb' for the application criteria of the equivalent-field method is also aimed. Materials and Methods: Three x-ray beams, 4-, 6- and 10-MV, were employed for this study. Width of the rectangular field was ranged from 5-40 cm and the elongation ratio (length/width) 1:0 to 10:0. An elongation effect was measured in a water phantom at three different depths, dmax, 5-cm, and 10-cm. For an elongated field and its equivalent square field, the output factor was measured and the difference in the output factor were examined between two fields. Results and Discussions: As the elongation ratio increases, a larger discrepancy in outputs is observed between the elongated rectangular field and its corresponding equivalent square field. Output was measured larger for an elongated field than for its corresponding equivalent square field and the maximal difference over 10 % was found. The difference was found larger for the smaller field with the same elongation ratio. The effect of the beam quality and the depth of measurement on the output difference was minimal. Conclusion: Based on the study, there is criteria for the application of the method for output calculation. For the combination of long axis and elongation ratio whose relationship satisfies Elongation ratio < (0.48) (Long axis) - 0.5, the equivalent-field method is valid for output calculation within 2 % for the field whose long axis < 25-cm. For other combinations, instead of using the equivalent-field method, direct output measurement is recommended. This criteria can be applied for 4-10 MV x-ray beams up to 10-cm depth.

  • PDF

Radical Radiotherapy for Carcinoma of the Prostate (전립선암의 근치적 방사선치료)

  • Chun, Ha-Chung;Lee, Myung-Za
    • Radiation Oncology Journal
    • /
    • v.19 no.1
    • /
    • pp.40-44
    • /
    • 2001
  • Purpose : To evaluate effect and tolerance of external beam radiotherapy for carcinoma of the prostate and define the optimal radiotherapeutic regimen. Materials and methods : We retrospectively analyzed the records of 60 patients with prostate cancer who were treated with external beam radiotherapy with curative intent in our institution between September, 1987 and March, 2000. Histologic diagnosis was established by transurethral resection or ultrasonography guided biopsy. The major presenting symptoms were a nodule at routine prostatic examination and frequency and urgency of urination, along with dysuria. The median age was 63 years with range of 51 to 87 years. There were 6 patients in Stage A, 20 in Stage 8, 26 in Stage C, and 8 in Stage Dl. All patients were treated with megavoltage equipment producing 10 MV photons. The 4 field pelvic brick technique was used to a dose of 45 Gy or 50.4 Gy at 1.8 Gy per day in 5 to 6 weeks, after which a small boost field was delivered 2.0 Gy per day to a total dose of 66 to 70 Gy. The follow-up period ranged from 1 to 8 years. Results : Actuarial 5-year and 7-year survival rates for Stage A, B, C, and D1 were $100\%\;and\;84\%$, $83\%\;and\;72\%$, $67\%\;and\;54\%$, and $v$, respectively. The corresponding 5-year and 7-year relapse free survival rates were $84\%\;and\;84\%$, $77\%\;and\;67\%$, $48\%\;and\;40\%$, and $33\%\;and\;25\%$, respectively. Relapse free 5-year survival rates for Stage B were $80\%,\;80\%,\;and\;50\%$ for well, moderately, and poorly differentiated tumors, respectively. These were $64\%,\;44\%,\;and\;33\%$ for Stage C, respectively. The local control rates at 5 years were $84\%,\;85\%,\;78\%,\;and\;60\%$ for Stage A, B, C, and D1, respectively. Mild to moderate complications were observed in $22\%$ of patients. Severe complications requiring surgical procedures were documented in only $3\%$ of patients. Conclusion : This study confirms that external beam irradiation is an effective and safe treatment for prostatic cancer, providing long-term local control and good survival with acceptable complications.

  • PDF

A Study on GPU-based Iterative ML-EM Reconstruction Algorithm for Emission Computed Tomographic Imaging Systems (방출단층촬영 시스템을 위한 GPU 기반 반복적 기댓값 최대화 재구성 알고리즘 연구)

  • Ha, Woo-Seok;Kim, Soo-Mee;Park, Min-Jae;Lee, Dong-Soo;Lee, Jae-Sung
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.5
    • /
    • pp.459-467
    • /
    • 2009
  • Purpose: The maximum likelihood-expectation maximization (ML-EM) is the statistical reconstruction algorithm derived from probabilistic model of the emission and detection processes. Although the ML-EM has many advantages in accuracy and utility, the use of the ML-EM is limited due to the computational burden of iterating processing on a CPU (central processing unit). In this study, we developed a parallel computing technique on GPU (graphic processing unit) for ML-EM algorithm. Materials and Methods: Using Geforce 9800 GTX+ graphic card and CUDA (compute unified device architecture) the projection and backprojection in ML-EM algorithm were parallelized by NVIDIA's technology. The time delay on computations for projection, errors between measured and estimated data and backprojection in an iteration were measured. Total time included the latency in data transmission between RAM and GPU memory. Results: The total computation time of the CPU- and GPU-based ML-EM with 32 iterations were 3.83 and 0.26 see, respectively. In this case, the computing speed was improved about 15 times on GPU. When the number of iterations increased into 1024, the CPU- and GPU-based computing took totally 18 min and 8 see, respectively. The improvement was about 135 times and was caused by delay on CPU-based computing after certain iterations. On the other hand, the GPU-based computation provided very small variation on time delay per iteration due to use of shared memory. Conclusion: The GPU-based parallel computation for ML-EM improved significantly the computing speed and stability. The developed GPU-based ML-EM algorithm could be easily modified for some other imaging geometries.