• Title/Summary/Keyword: Radiation spectrum

Search Result 512, Processing Time 0.024 seconds

Fabrication of $CaSO_4$ : Tm, $CaSO_4$ : Tm-PTFE TLD Radiation Sensors and Its Characteristics ($CaSO_4$ : Tm, $CaSO_4$ : Tm-PTFE TLD 소자의 제작과 특성에 관한 연구)

  • Park, Myeong-Hwan;Lee, Joon-Il
    • Journal of radiological science and technology
    • /
    • v.16 no.1
    • /
    • pp.107-115
    • /
    • 1993
  • In this study, to develop highly sensitive radiation sensors, $CaSO_4$ : Tm phosphors and its disc-type TLD elements embedded PTFE(polytetrafluoroethylene) are fabricated. The highest sensitivity of $CaSO_4$ : Tm phosphors is obtained when phosphors have been doped with 0.5mol % Tm and sintered in atmosphere at $600^{\circ}C$ for two hours. Fabricated disc-type elements are made from a homogeneous mixture of phosphors and PTFE powder. They are first cold-pressed and then polymerized at $370^{\circ}C$ in air for one hour. The dose dependence of the prepared $CaSO_4$ : Tm TLD radiation sensors is linear within the range of $100{\mu}Gy{\sim}10Gy$ for X-rays and ${\gamma}-rays$. The response of $CaSO_4$ : Tm to 30keV X-rays is ten times higher than that of 1.25MeV $^{60}Co\;{\gamma}-rays$. The fading rate of the main peak is about 2% per a month. The spectral peaks of TL emission spectrum are at about 350nm and 475nm. The $CaSO_4$ : Tm TLD radiation sensors prepared in this work may be used as radiation dosimeter for personal and environmental monitoring because of their high sensitivity and little fading.

  • PDF

Effects of Plasticizer to Polyvinylchloride on Radio-resistance of Organic Stabilizer,Dielectric and Mechanical Characteristics under the Influence of Radiation (Polyvinylchloride에 있어 가소제의 첨가가 유기안정제의 내 방사성 및 유전, 기계적 특성에 미치는 영향)

  • 김봉흡;강도열;이재인
    • 전기의세계
    • /
    • v.26 no.2
    • /
    • pp.89-94
    • /
    • 1977
  • In order to investigate the properties of radiation resistance together with dielectric, and mechanical relaxation behaviors of polyvinylcholoride exposed to several different doses under the .gamma.-ray of Co$^{60}$ source, several observations were carried out on the exposed specimens propared by mixing dibutyl-tin-dilaulate and dibutyl-tin-dimaleate as stabilizer with or without adding dioctyl-phthalate as plasticizer. Conclusions obtained from the study are as follows: The origin of the absorption band at 1,540-1,640$cm^{-1}$ / on I.R. spectrum seems to be RCOO- ion originated from ionization of the stabilizer, and this peak can be useful as a measure of radiation resistance on polyvinylchloride. Addition of increasing plasticizer to polyvinylchloride exhibits increasing radiation resistance and the reason for this result may be attributed to aromatic resonance absorption of radiation energy by diotylphthalate. On dose dependent dielectric characteristics, nonplastized specimen shows a peak at about 10 Mrad and that this peak disappears on the plastification of specimens. Those phenomena may be explainable in considering the statistical distribution of scissored chain molecular segments as well as the plastification process of plasticizer to polyvinylchloride chain molecules.

  • PDF

Evaluation of Radiation Degradation or Crosslinked Polyethylene using TGA (TGA를 이용한 가교폴리에틸렌의 방사선 열화 평가)

  • Lee, Chung;Kim, Ki-Yup;Ryu, Boo-Hyung;Lim, Kee-Joe
    • Journal of the Korean Society of Safety
    • /
    • v.18 no.2
    • /
    • pp.50-55
    • /
    • 2003
  • Radiation degradation of crosslinked polyethylene(XLPE) was investigated using thermogravimetric analysis(TGA), The results of TGA were compared with FT-IR, melting temperature, oxidation induction time, and elongation at break on the XLPE exposed by $\gamma$-ray. 5% decomposition temperature of $\gamma$-ray irradiated XLPE showed similar tendencies with the case of elongation at break. Both properties agreed below 1000 KGy, however, did not show any remarkable characteristics above 1000 kGy, these properties can be useful to evaluate the radiation degradation of XLPE for only low irradiated region. Above 1000 kGy, the thermal decomposition activation energy showed decreased, on the contrary, increasing below 1000 kGy. Compared with FT-IR spectrum of irradiated XLPE, it was confirmed that the oxidation reaction was still occurring below 1000 kGy. Radiation degradation of XLPE was dependent upon the irradiation doses, TGA can be a useful tool to evaluate the degradation.

Assessment of Temporary Radioactivation for Tissue Expanders in Breast Radiation Therapy: Preliminary Study

  • Hwajung Lee;Do Hoon Oh;Lee Yoo;Minsoo Chun
    • Journal of Radiation Protection and Research
    • /
    • v.48 no.2
    • /
    • pp.100-106
    • /
    • 2023
  • Background: As breast tissue expanders consist of metallic materials in the needle guard and ferromagnetic injection port, irradiation can produce radioactivation. Materials and Methods: A CPX4 (Mentor Worldwide LLD) breast tissue expander was exposed using the Versa HD (Elekta) linear accelerator. Two photon energies of 6 and 10 MV-flattening filter free (FFF) beams with 5,000 monitor units (MU) were irradiated to identify the types of radiation. Furthermore, 300 MU with 10 MV-FFF beam was exposed to the CPX4 breast tissue expander by varying the machine dose rates (MDRs) 600, 1,200, and 2,200 MU/min. To assess the instantaneous dose rates (IDRs) solely from the CPX4, a tissue expander was placed outside the treatment room after beam irradiation, and a portable radioisotope identification device was used to identify the types of radiation and measure IDR. Results and Discussion: After 5,000 MU delivery to the CPX4 breast tissue expander, the energy spectrum whose peak energy of 511 keV was found with 10 MV-FFF, while there was no resultant one with 6 MV-FFF. The time of each measurement was 1 minute, and the mean IDRs from the 10 MV-FFF were 0.407, 0.231, and 0.180 μSv/hr for the three successive measurements. Following 10 MV-FFF beam irradiation with 300 MU indicated around the background level from the first measurement regardless of MDRs. Conclusion: As each institute room entry time protocol varies according to the working hours and occupational doses, we suggest an addition of 1 minute from the institutes' own room entry time protocol in patients with CPX4 tissue expander and the case of radiotherapy vaults equipped with a maximum energy of 10 MV photon beams.

GESS-A Code for Verification of Shielding Integrity by Monte Carlo Method (몬테칼로 방법에 의한 차폐체 건전성 검증코드 개발)

  • Lee, Tae-Young;Ha, Chung-Woo;Lee, Jai-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.11 no.1
    • /
    • pp.29-36
    • /
    • 1986
  • GESS-a computer code for simulation of energy spectra for gamma-ray in NaI(T1) scintillator has been developed. The Monte Carlo method was employed to simulate physical behaviours of particle transport in a medium. In the processes of simulation, all the interaction processes such as Rayleigh and Compton scattering, photoelectric effect and pair production were considered. The resulting electron slowing down spectrum was also considered with the CSDA model. For the purpose of verification of the code, a measurement gamma spectrum for incident gamma energy of 1.33 MeV was performed. The measured values appeared to be slightly higher than the theoretically calculated values.

  • PDF

Characteristics of Low-power Microwave Induced Plasma Emission Spectrum and Detection of $CO_2$ (저출력 마이크로파 유도 플라스마 방출스펙트럼의 특성과 $CO_2$ 분석)

  • Noh, Seung Man;Park, Chang Joon;Kim, Young Sang
    • Journal of the Korean Chemical Society
    • /
    • v.40 no.4
    • /
    • pp.235-242
    • /
    • 1996
  • A surfatron-type microwave induced plasma (MIP) cavity has been constructed, which can be easily interfaced with a gas chromatograph. Various plasma gases such as He, Ar and N2 were used to generate the MIP and small amounts of CO2 gases were injected through the MIP to obtain characteristic spectrum of each plasma gas and to study feasibility of the MIP as a soft ionization source. Since He and Ar plasmas have high metastable state energy, it was not possible to detect sample gas in molecular state. With N2 plasma, however, a strong emission of molecular ions could be detected owing to its low metastable state energy.

  • PDF

Effect of Prompt Fission Neutron Spectral Formulae on Nuclear Criticality (핵분열(核分裂) 중성자(中性子)스펙트럼이 핵임계도(核臨界度)에 미치는 효과(效果))

  • Ro, Seung-Gy;Min, Duck-Kee;Youk, Geun-Uck;Oh, Hi-Peel
    • Journal of Radiation Protection and Research
    • /
    • v.7 no.1
    • /
    • pp.56-60
    • /
    • 1982
  • A calculation of the effective multiplication factor has been made for GODIVA and JEZEBEL critical assemblies by using a computer code, ANISN, with having the Watt's, Cranberg's and Maxwellian formulae for the prompt fission neutron spectrum as a fission source. Then the calculated values have been compared with experimental data obtained by others. The Maxwellian formula seems to be the best one for representing the prompt fission neutron spectrum since the effective multiplication factor based on it shows a better agreement with the experimental value compared to the rest formulae.

  • PDF

A Copper Shield for the Reduction of X-γ True Coincidence Summing in Gamma-ray Spectrometry

  • Byun, Jong-In
    • Journal of Radiation Protection and Research
    • /
    • v.43 no.4
    • /
    • pp.137-142
    • /
    • 2018
  • Background: Gamma-ray detectors having a thin window of a material with low atomic number can increase the true coincidence summing effects for radionuclides emitting X-rays or gamma-rays. This effect can make efficiency calibration or spectrum analysis more complicated. In this study, a Cu shield was tested as an X-ray filter to neglect the true coincidence summing effect by X-rays and gamma-rays in gamma-ray spectrometry, in order to simplify gamma-ray energy spectrum analysis. Materials and Methods: A Cu shield was designed and applied to an n-type high-purity germanium detector having an $X-{\gamma}$ summing effect during efficiency calibration. This was tested using a commercial, certified mixed gamma-ray source. The feasibility of a Cu shield was evaluated by comparing efficiency calibration results with and without the shield. Results and Discussion: In this study, the thickness of a Cu shield needed to avoid true coincidence summing effects due to $X-{\gamma}$ was tested and determined to be 1 mm, considering the detection efficiency desired for higher energy. As a result, the accuracy of the detection efficiency calibration was improved by more than 13% by reducing $X-{\gamma}$ summing. Conclusion: The $X-{\gamma}$ summing effect should be considered, along with ${\gamma}-{\gamma}$ summing, when a detection efficiency calibration is implemented and appropriate shielding material can be useful for simplifying analysis of the gamma-ray energy spectra.

Study on Dual-Energy Signal and Noise of Double-Exposure X-Ray Imaging for High Conspicuity

  • Song, Boram;Kim, Changsoo;Kim, Junwoo
    • Journal of Radiation Protection and Research
    • /
    • v.46 no.4
    • /
    • pp.160-169
    • /
    • 2021
  • Background: Dual-energy X-ray images (DEI) can distinguish or improve materials of interest in a two-dimensional radiographic image, by combining two images obtained from separate low and high energies. The concepts of DEI performance describing the performance of double-exposure DEI systems in the Fourier domain been previously introduced, however, the performance of double-exposure DEI itself in terms of various parameters, has not been reported. Materials and Methods: To investigate the DEI performance, signal-difference-to-noise ratio, modulation transfer function, noise power spectrum, and noise equivalent quanta were used. Low- and high-energy were 60 and 130 kVp with 0.01-0.09 mGy, respectively. The energy-separation filter material and its thicknesses were tin (Sn) and 0.0-1.0 mm, respectively. Noise-reduction (NR) filtering used the Gaussian-filter NR, median-filter NR, and anti-correlated NR. Results and Discussion: DEI performance was affected by Sn-filter thickness, weighting factor, and dose allocation. All NR filtering successfully reduced noise, when compared with the dual-energy (DE) images without any NR filtering. Conclusion: The results indicated the significance of investigating, and evaluating suitable DEI performance, for DE images in chest radiography applications. Additionally, all the NR filtering methods were effective at reducing noise in the resultant DE images.

The emission spectrum from isolated black holes

  • Gwon, Sun-Ja;Park, Myeong-Gu
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.40 no.1
    • /
    • pp.86.3-86.3
    • /
    • 2015
  • There could be significant numbers of isolated stellar mass black holes in our Galaxy. The detection of these black holes will provide important clues on the origin of supermassive black holes. Interstellar gas will be accreted to these isolated black holes in nearly spherical flow. The gas and the interstellar magnetic field will be compressed and emit bremsstrahlung and magnetic bremsstrahlung. We calculate the density, temperature, magnetic field of the accretion flow onto a 10 solar mass black hole as well as its radiative emission; special attention is given to cyclotron radiation and synchrotron radiation, which covers from microwave to X-ray. We consider the possibility to detect these radiation from isolated Galactic black holes with current instruments and surveys.

  • PDF