Argonne National Laboratory of the United States and Kharkov Institute of Physics and Technology (KIPT) of Ukraine have cooperated on the development, design, and construction of a neutron source facility. The facility was constructed at Kharkov, Ukraine, and its commissioning process is underway. The facility will be used for researches, producing medical isotopes, and training young nuclear specialists. The neutron source facility is designed with a provision to include a cryogenically cooled moderator system-a cold neutron source (CNS). This CNS provides low-energy neutrons, which will be used in the scattering experiment and material structures analysis. Cold neutron guides, coated with reflective material for the low-energy neutrons, will be used to transport the cold neutrons to the experimental site. The cold neutron guides would keep the cold neutrons within certain energy and angular space concentrated inside, while most of the gamma rays and high-energy neutrons are not affected by the cold neutron guides. For the KIPT design, the cold neutron guides need to extend several meters outside the main shield of the facility, and curved guides will also be used to remove the gamma and high-energy neutron. The neutron guides should be installed inside a shield structure to ensure an acceptable biological dose in the facility hall. Heavy concrete is the selected shielding material because of its acceptable performance and cost. Shield design analysis was carried out for the CNS guide hall. MCNPX was used as the major computation tool for the design analysis, with neutron and gamma dose calculated separately. Weight windows variance reduction technique was also used in the shield design. The goal of the shield design is to keep the total radiation dose below the $5.0{\mu}Sv/hr$ guideline outside the shield boundary. After a series of iterative MCNPX calculations, the shield configuration and parameters of CNS guide hall were determined and presented in this article.
방사성 동위원소 등의 고준위 방사성물질을 운반하기 위한 운반용기는 국내외의 관련법규에 따라 정상수송은 물론 가상사고조건에서도 방사성물질의 누설이 발생되지 않도록 방사선차폐, 열 및 구조적 건전성이 유지되어야 한다. 운반용기의 건전성 평가는 시험모델을 이용한 시험적 방법과 전산해석 코드를 이용한 해석적 방법에 의하여 이루어지고 있다. 본 논문에서는 원자력연구소의 하나로에서 생산되는 동위원소를 동위원소 생산시설까지 이송하기 위한 HTS (Hydraulic Transfer System) 방사성 동위원소 운반용기의 안전성을 평가하였다. 방사선차폐해석, 열해석 및 구조해석을 수행한 결과 동위원소 운반용기는 정상수송조건 뿐만 아니라 가상사고조건에서도 건전성이 유지되는 것으로 나타났다.
The accuracy of the photoatomic cross-section data is of great importance in the field of radiation protection, particularly in the characterization of radiation shielding materials. With the release of the latest and probably the most accurate photoatomic data library, EPDL2017, the need to re-evaluate all the existing and already established mass attenuation coefficients (MACs) of all radiation shielding materials arises. The MACs of several polymers, alloy-based, glasses, and building materials used in a nuclear medicine facility were investigated using the EPDL2017 library embedded in EpiXS software and were compared to MACs available in the literature. The relative differences between MACEpiXS and MACXCOM were negligible, ranging from 0.02% to 0.36% for most materials. However, for material like a glass comprising of elements Te and La evaluated near their corresponding K-edge energies, the relative differences in MACs increased up to 1.46%. On the other hand, a comparison with MACs calculated based on EPDL97 (a predecessor of EPDL2017) revealed as much as a 6.61% difference. Also, it would seem that the changes in MACs were more evident in the materials composed of high atomic number elements evaluated at x-ray energies compared to materials composed of low atomic number elements evaluated at gamma-ray energies.
전 세계적으로 컴퓨터 단층 촬영 장치(Computed Tomography, CT)의 임상 적용이 환자의 질병의 조기 진단에 매우 중요하게 사용되고 있으며 사용 빈도 또한 매년 급증하고 있다. 새로운 종류의 CT 장치들이 병변을 조기 진단하기 위하여 개발되고 있다. 이 방사선 발생 장치에 의한 환자나 작업 종사자들의 방사선 피폭이 불가피 할 수도 있다. 국내에서는 CT 장치에 대한 구체적인 방사선 방어나 방사선 시설에 대한 구체적인 규정이 확립되어 있지 않다. 본 논문에서는 국내에서의 CT 사용시설에 대한 방사선 방어 시설과 사용 기준에 대한 규정 마련에 토대를 이루기 위하여 외국에서의 CT 장비에 대한 방사선 방어 및 방사선 차폐에 대한 규정을 조사하였다. 조사방법으로는 구글 검색을 이용한 특정 키워드 검색과 방사선 관련 업무를 수행하는 특정 웹사이트를 직접 검색하는 방법을 사용하였다. 검색결과 캐나다, 미국, 영국 등의 국가에서 국가의 실정에 맞는 가이드라인을 사용하고 있었으나, 아직 이중 에너지 CT에 대한 가이드라인은 없는 것으로 나타났다. 한국에서도 국내 실정에 적합한 CT 장비에서의 방사선 방어, 차폐, 환자나 작업종사자 및 일반인에 대한 방사선 피폭에 대한 가이드라인의 설정이 필요하다고 생각된다.
Korea expects a shortage in storage capacity for spent fuels at reactor sites. Therefore, a need for more metal and/or concrete casks for storage systems is anticipated for either the reactor site or away from the reactor for interim storage. For the purpose of interim storage and transportation, a dual purpose metal cask that can load 21 spent fuel assemblies is being developed by Korea Radioactive Waste Management Corporation (KRMC) in Korea. At first the gamma and neutron flux for the design basis fuel were determined assuming in-core environment (the temperature, pressure, etc. of the moderator, boron, cladding, $UO_2$ pellets) in which the design basis fuel is loaded, as input data. The evaluation simulated burnup up to 45,000 MWD/MTU and decay during ten years of cooling using the SAS2H/OGIGEN-S module of the SCALE5.1 system. The results from the source term evaluation were used as input data for the final shielding evaluation utilizing the MCNP Code, which yielded the effective dose rate. The design of the cask is based on the safety requirements for normal storage conditions under 10 CFR Part 72. A radiation shielding analysis of the metal storage cask optimized for loading 21 design basis fuels was performed for two cases; one for a single cask and the other for a $2{\times}10$ cask array. For the single cask, dose rates at the external surface of the metal cask, 1m and 2m away from the cask surface, were evaluated. For the $2{\times}10$ cask array, dose rates at the center point of the array and at the center of the casks' height were evaluated. The results of the shielding analysis for the single cask show that dose rates were considerably higher at the lower side (from the bottom of the cask to the bottom of the neutron shielding) of the cask, at over 2mSv/hr at the external surface of the cask. However, this is not considered to be a significant issue since additional shielding will be installed at the storage facility. The shielding analysis results for the $2{\times}10$ cask array showed exponential decrease with distance off the sources. The controlled area boundary was calculated to be approximately 280m from the array, with a dose rate of 25mrem/yr. Actual dose rates within the controlled area boundary will be lower than 25mrem/yr, due to the decay of radioactivity of spent fuel in storage.
I. 목적 방사선치료에 사용되는 선형가속기를 설치하기 위해서는 국내 원자력법 및 국제 방사선방어규정에 의거하여 일정 면적이상의 설치공간을 확보하는 것은 물론 방사선 방호 등의 차폐두께를 면밀히 검토하여 시설공사를 시행한다. 본원에서는 방사선치료 환자의 증가로 인하여 치료장비의 증설이 요구됨에 따라 기존시설에 장비설치를 위한 공간확보의 어려움이 초래되었다. 이에 차폐벽의 두께를 최소화하면서 공간을 확보할 수 있는 특수차폐물인 Ledite(Atomin International사, 미국)를 사용하여 시공한 결과를 보고하고자 한다. II. 대상 및 방법 본원에 추가 도입되는 6MV 선형가속기, 15MV 선형가속기실의 차폐시설을 밀도가 다른 두 종류인 Ledite XN240 (15MV-TVT19.1cm, 6MV-TVT15.2cm), Ledite XN288 (15MV-TVT20.3cm, 6MV-TVT15.2cm)를 사용하여 기존 건축시설에 의한 특수공법으로 국내 건축기술진에 의해 시공하였다. III. 결과 및 고찰 콘크리트에 의한 건축과 Ledite에 의한 건축을 비교하였을 때 최대(천정)236.4cm를 103.7cm로, 최소(벽)158cm를 69.4cm로 2배의 벽두께를 축소할 수 있었다. 공사기간은 Ledite의 경우는 약 90일, 콘크리트는 150일로 건축기간을 2개월 단축시킬 수 있고, 또한 Ledite는 취급 운반이 용이하고, 시공의 안정성과 공사후 에너지에 따른 장비의 변경시에도 쉽게 재시공 가능한 이점이 있다. 반면에 공사비용은 Ledite는 약 10억(예상), 콘크리트는 약 4억 정도로 고가의 공사비가 지출됨을 알 수 있었다. IV. 결론 시공후 survey meter로 측정한 결과, 누출선량이 허용선량 이내로 측정되었으며, 본원과 같은 제한된 공간에 방사선시설을 차폐할 경우 Ledite를 이용함으로써 공사기간 단축 및 효율적인 이용이 가능하였으나 공사비요 지출 증가가 예상된다.
Pyroprocess technology has been considered as a fuel cycle option to solve the spent fuel accumulation problems in Korea. The Korea Atomic Energy Research Institute has been studying pyroprocess technology, and the conceptual design of an engineering-scale pyroprocess facility, called the Advanced Fuel Cycle (AFC) facility, has been performed on the basis of a 10tHM throughput per year. In this paper, the concept of the AFC facility was introduced, and its safety evaluations were performed. For the safety evaluations, anticipated accident events were selected, and environmental safety analyses were conducted for the safety of the public and workers. In addition, basic radiation shielding safety analyses and criticality safety analyses were conducted. These preliminary safety studies will be used to specify the concept of safety systems for pyroprocess facilities, and to establish safety design policies and advance more definite safety designs.
한국원자력연구소에서는 고온의 용융염 매질 하에서 사용 후 핵연료를 환원시키는 차세대관리종합공정 연구를 수행 중에 있다. 추후 본 기술개발을 실증시험 하기 위해서는 방사선 차폐능이 확보된 핫셀이 필수적이며, 핫셀은 최대 1,385TBq의 방사능량에 대한 차폐 안전성을 가져야 한다. 최대 방사선원에 대한 핫셀의 차폐능을 확보하기 위하여, 본 연구에서는 실증시험 시 사용후핵연료부터 발생하는 중성자 및 감마선에 의한 선량률이 법적 허용선량치보다 낮게 유지되도록 핫셀의 차폐 설계에 대한 안전성을 평가하였다. QAD-CGGP 및 MCNP-4C 코드를 이용하여 핫셀 차폐체의 설계치에 대한 차폐 계산을 수행하였다. 작업구역에 대한 감마선 차폐계산 결과 QAD-CGGP 코드는 2.10${\times}$$10^{-3}$, 2.97${\times}$$10^{-3}$ mSv/h, MCNP-4C 코드는 1.60${\times}$$10^{-3}$, 2.99${\times}$$10^{-3}$ mSv/h 이었으며, 서비스 구역은 1.01${\times}$$10^{-2}$, 7.88${\times}$$10^{-2}$ mSv/h 로 평가되었다. 그리고 MCNP-4C코드를 이용하여 중성자에 의한 선량률을 계산한 결과, 중성자에 의한 선량률은 감마에 의한 선량률의 약 20% 이하치를 나타내었다. 따라서 선량률 대부분은 감마선에 의한 영향임을 알 수 있었다. 본 연구를 통하여 핫셀의 차폐 설계치가 작업구역의 선량 제한치 0.01 mSv/h 와 서비스 구역에서의 선량 제한치 0.15 mSv/h를 만족시키는 것을 확인할 수 있었다.
한국원자력환경공단에서는 국내 경수로 원전에서 발생된 사용후핵연료를 건식으로 저장할 수 있는 콘크리트 용기를 개발하였다. 본 저장용기는 사용후핵연료가 건식환경에서 장기간 저장되는 동안 용기 및 사용후핵연료의 건전성이 유지되며, 방사선량률이 저장시설의 설계기준을 초과하지 않도록 설계되어야 한다. 특히, 저장시설은 정상 및 사고조건에서 적절한 방사선 방호를 위한 차폐설계가 이루어져야 한다. 이를 위해 본 연구에서는 미국 10CFR72 및 10CFR20의 기술기준과 NRC의 표준 심사지침 NUREG-1536에서 제시한 평가방법에 따라 건식저장조건하에서 단일 콘크리트용기 및 $2{\times}10$ 용기배열조건의 선량율을 평가하였다. 평가결과, 일반인에 대한 연간선량 한도인 0.25 mSv를 만족하는 통제구역 경계까지의 거리는 약 230 m로 도출되었다. 콘크리트 저장용기의 설계사고는 $2{\times}10$ 배열의 저장시설에서 한 개의 저장용기가 이송 중 전도사고가 발생하여 용기의 바닥면이 통제구역 경계로 향하는 상황으로 가정하였다. 전도된 저장용기의 바닥면으로 부터 100 m 및 230 m 지점에서 각각 12.81 mSv 및 1.28 mSv로 평가되었다. 본 연구를 통해 건식저장조건에서 콘크리트 저장용기 및 저장시설은 적절하게 평가된 통제구역경계까지의 거리가 확보된다면 방사선적 안전성이 유지됨을 확인할 수 있었다. 본 평가결과만으로 건식환경의 저장용기(시설) 설계에 직접 적용하기는 어렵겠으나, 향후 '국가 고준위폐기물 관리 전략'에 근거한 원전내 저장시설 또는 중간저장 시설의 설계 및 운영에 유용한 자료가 될 것으로 사료된다.
As medical facilities are usually built at urban areas, special concrete aggregates and evaluation methods are needed to optimize the design of concrete walls by balancing density, thickness, material composition, cost, and other factors. Carbon treatment rooms require a high radiation shielding requirement, as the neutron yield from carbon therapy is much higher than the neutron yield of protons. In this case study, the maximum carbon energy is 430 MeV/u and the maximum current is 0.27 nA from a hybrid particle therapy system. Hospital or facility construction should consider this requirement to design a special heavy concrete. In this work, magnetite is adopted as the major aggregate. Density is determined mainly by the major aggregate content of magnetite, and a heavy concrete test block was constructed for structural tests. The compressive strength is 35.7 MPa. The density ranges from 3.65 g/cm3 to 4.14 g/cm3, and the iron mass content ranges from 53.78% to 60.38% from the 12 cored sample measurements. It was found that there is a linear relationship between density and iron content, and mixing impurities should be the major reason leading to the nonuniform element and density distribution. The effect of this nonuniformity on radiation shielding properties for a carbon treatment room is investigated by three groups of Monte Carlo simulations. Higher density dominates to reduce shielding thickness. However, a higher content of high-Z elements will weaken the shielding strength, especially at a lower dose rate threshold and vice versa. The weakened side effect of a high iron content on the shielding property is obvious at 2.5 µSv=h. Therefore, we should not blindly pursue high Z content in engineering. If the thickness is constrained to 2 m, then the density can be reduced to 3.3 g/cm3, which will save cost by reducing the magnetite composition with 50.44% iron content. If a higher density of 3.9 g/cm3 with 57.65% iron content is selected for construction, then the thickness of the wall can be reduced to 174.2 cm, which will save space for equipment installation.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.