• 제목/요약/키워드: Radiation map

검색결과 156건 처리시간 0.028초

풍력자원 평가 및 육상바람지도 작성을 위한 고해상도 대기유동장 수치모의 (Atmospheric Numerical Simulation for an Assessment of Wind Resource and an Establishment of Wind Map on Land)

  • 정우식;이화운;김현구;최현정;이순환;김동혁;김민정
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 춘계학술대회 논문집
    • /
    • pp.529-531
    • /
    • 2009
  • To construct the wind map for mainland Korea, the well designed atmospheric numerical modeling system was used. Three nest domains were construced with spatial resolutions between $10{\times}10km$ up to the hightest resolution of $1{\times}1km$. Parameterization schemes like MRF(PBL), RRTM(radiation), Grell(cumulus) were chosen since wind data simulated is in better agreement with the observed wind data. High-resolution atmospheric numerical model was applied to simulate the motion of the atmosphere and to produce the wind map around the South Korea. The results of several simulations were improved compare to the past system, because of using the fine geographical data, such as terrain height and land-use data, and the meteorological data assimilation.

  • PDF

Constraining the Evolution of Epoch of Reionization by Deep-Learning the 21-cm Differential Brightness Temperature

  • Kwon, Yungi;Hong, Sungwook E.
    • 천문학회보
    • /
    • 제44권2호
    • /
    • pp.78.3-78.3
    • /
    • 2019
  • We develop a novel technique that can constrain the evolutionary track of the epoch of reionization (EoR) by applying the convolutional neural network (CNN) to the 21-cm differential brightness temperature. We use 21cmFAST, a fast semi-numerical cosmological 21-cm signal simulator, to produce mock 21-cm map between z=6-13. We design a CNN architecture that predicts the volume-averaged neutral hydrogen fraction from the given 21-cm map. The estimated neutral fraction has a good agreement with its truth value even after smoothing the 21-cm map with somewhat realistic choices of beam size and the frequency bandwidth of the Square Kilometre Array (SKA). Our technique could be further utilized to denoise the 21-cm map or constrain the properties of the radiation sources.

  • PDF

한국형 고속철도 노선 주변 지역의 소음 지도 작성과 소음 영향 분석 (Development of a Noise Map in Neighboring Areas Around Korean Train Express Line and Analysis of the Related High Speed Railway Noise Influence)

  • 이진영;길현권;이찬;김진태
    • 환경영향평가
    • /
    • 제20권4호
    • /
    • pp.443-453
    • /
    • 2011
  • The purpose of present study is to develop a noise map around Korean Train Express (KTX) line. It is also to evaluate the high speed railway noise influence in neighboring areas around KTX. In order to develop the noise map, noise source modeling and 3-D noise radiation simulation have been performed by means of SoundPLAN program. The result of the noise map has been verified in comparison with the measured noise level. Noise measurements have been performed at 15 locations around KTX line. At each locations, 6 microphones were located 1.5m and 3m above the ground at each of 25m, 50m and 75 m distances from a center of the KTX track. The noise map showed clearly the high speed railway noise influence in neighboring areas around KTX line. The present study has also showed the noise could be reduced by using noise barriers constructed at severely noise-exposed locations.

토모테라피 환자 치료 선량 분석을 위한 3DVH 프로그램 평가 (Evaluation of 3DVH Software for the Patient Dose Analysis in TomoTherapy)

  • 송주영;김용협;정재욱;윤미선;안성자;정웅기;남택근
    • 한국의학물리학회지:의학물리
    • /
    • 제26권4호
    • /
    • pp.201-207
    • /
    • 2015
  • 세기조절방사선치료의 선량정확도에 대한 품질보증 과정에서 측정된 데이터를 기반으로 실제 치료 환자 신체 내의 치료 선량분포를 재계산하여 치료계획 시 계산된 선량분포와 비교, 분석을 수행할 수 있는 프로그램들이 개발되어 임상에 사용 중에 있다. 본 연구에서는 아크첵(ArcCHECK)을 사용하여 품질보증 과정에서 측정한 토모테라피 선량 데이터를 기반으로 환자 내 치료선량 분포를 재구성할 수 있는 3DVH 프로그램의 새로운 기능 및 선량정확도를 평가하고자 하였다. 이를 위한 가상의 환자로 이차원 다이오드 검출기 배열 장치인 MapCHECK 영상을 사용하여 토모테라피 치료계획을 수립하고, 아크첵으로 선량을 측정 후 다시 3DVH를 사용하여 MapCHECK 검출기 영역의 선량분포를 재계산한 후, 실제 MapCHECK에서 측정된 선량분포와 비교하여, 그 오차를 분석하였다. 분석 결과, 측정값과 3DVH 계산값 비교를 위한 감마평가에서 평균 합격률은 $92.6{\pm}3.5%$로 측정값과 토모치료계획에서 계산된 선량과의 감마평가 평균 합격률 $99.0{\pm}1.2%$보다 오차가 큼을 보였다. 래피드아크에서 비교한 3DVH 계산값과 측정값의 감마평가 평균 합격률 $99.3{\pm}0.9%$와 비교하였을 경우에도 더 큰 오차를 보여, 토모테라피에서 3DVH 선량 계산 기능을 임상에서 신뢰하고 사용하기에는 더 많은 측정 결과들의 분석과 오차 원인에 대한 분석이 수행되어야 할 것으로 생각된다.

호흡연동 래피드아크 치료 시 빔 조사 구간 설정에 따른 선량 변화 분석 (Dosimetric Analysis of Respiratory-Gated RapidArc with Varying Gating Window Times)

  • 윤미선;김용협;정재욱;남택근;안성자;정웅기;송주영
    • 한국의학물리학회지:의학물리
    • /
    • 제26권2호
    • /
    • pp.87-92
    • /
    • 2015
  • 호흡연동 래피드아크 치료는 무건운 하중의 선형가속기 갠트리의 회전과 정지의 반복과정에서 갠트리 회전 재시작점의 오차와 다엽조리개의 정확한 움직임 및 갠트리 속도와 같은 래피드아크의 선량정확도를 결정하는 요소들의 오차 가능성으로 인한 선량 오류가 발생할 수 있다. 본 연구에서는 이러한 갠트리의 회전과 정지의 반복적인 동작이 호흡연동 래피드아크 치료의 정확도에 어떠한 영향을 끼치는 지 치료 시 총 회전과 정지 동작 수를 결정하는 빔조사 구간 길이의 변화를 통해 분석하였다. 총 10명의 간암 환자를 대상으로 래피드아크 치료계획을 수립하였고, RPM 호흡연동 장치와 정확한 빔조사 구간 길이를 설정하기 위해 동적 팬텀을 사용하였다. 각 래피드아크 치료계획 당 EPID를 사용한 portal dosimetry delivery quality assurance (DQA) 계획과 이차원 다이오드 검출기배열장치인 MapCHECK2를 사용한 DQA 계획을 수립하여 호흡연동 방사선 치료과정에서 누적된 선량분포의 정확도를 분석하였다. 모든 환자의 호흡주기는 4초로 설정하였고, 수립한 DQA 계획들을 호흡연동 없이 연속적으로 조사하는 것과, 1초의 빔조사 구간과 2초의 빔조사 구간, 총 3가지의 경우에 대해 실제 방사선량 측정과 감마평가를 통해 선량의 정확도를 분석하였다. Portal dosimetry DQA 경우 평균 감마평가의 합격률은 호흡연동 없이 연속적일 때 $98.72{\pm}0.82%$ 였고, 1초의 빔조사 구간의 경우 $94.91{\pm}1.64%$, 2초의 빔조사 구간의 경우 $98.23{\pm}0.97%$이었다. MapCHECK2 DQA경우 평균 감마평가의 합격률은 호흡연동 없이 연속적일 때 $97.80{\pm}0.91%$였고, 1초의 빔조사 구간의 경우 $95.38{\pm}1.31%$, 2초의 빔조사 구간의 경우 $97.50{\pm}0.96%$였다. 본 연구 결과를 통해 빔조사 구간의 길이가 증가하여 갠트리 정지 동작 수가 감소할수록 호흡연동 래피드아크의 선량 정확도가 증가함을 확인할 수 있었으며, 이러한 특성을 호흡연동 방사선치료 대상 환자의 선정 및 호흡방식에 대한 교육과정에 고려되어야 할 것으로 판단되었다.

Optimal Density Assignment to 2D Diode Array Detector for Different Dose Calculation Algorithms in Patient Specific VMAT QA

  • Park, So-Yeon;Park, Jong Min;Choi, Chang Heon;Chun, Minsoo;Han, Ji Hye;Cho, Jin Dong;Kim, Jung-in
    • Journal of Radiation Protection and Research
    • /
    • 제42권1호
    • /
    • pp.9-15
    • /
    • 2017
  • Background: The purpose of this study is to assign an appropriate density to virtual phantom for 2D diode array detector with different dose calculation algorithms to guarantee the accuracy of patient-specific QA. Materials and Methods: Ten VMAT plans with 6 MV photon beam and ten VMAT plans with 15 MV photon beam were selected retrospectively. The computed tomography (CT) images of MapCHECK2 with MapPHAN were acquired to design the virtual phantom images. For all plans, dose distributions were calculated for the virtual phantoms with four different materials by AAA and AXB algorithms. The four materials were polystyrene, 455 HU, Jursinic phantom, and PVC. Passing rates for several gamma criteria were calculated by comparing the measured dose distribution with calculated dose distributions of four materials. Results and Discussion: For validation of AXB modeling in clinic, the mean percentages of agreement in the cases of dose difference criteria of 1.0% and 2.0% for 6 MV were $97.2%{\pm}2.3%$, and $99.4%{\pm}1.1%$, respectively while those for 15 MV were $98.5%{\pm}0.85%$ and $99.8%{\pm}0.2%$, respectively. In the case of 2%/2 mm, all mean passing rates were more than 96.0% and 97.2% for 6 MV and 15 MV, respectively, regardless of the virtual phantoms of different materials and dose calculation algorithms. The passing rates in all criteria slightly increased for AXB as well as AAA when using 455 HU rather than polystyrene. Conclusion: The virtual phantom which had a 455 HU values showed high passing rates for all gamma criteria. To guarantee the accuracy of patent-specific VMAT QA, each institution should fine-tune the mass density or HU values of this device.

Feasibility Study of Patient Specific Quality Assurance Using Transit Dosimetry Based on Measurement with an Electronic Portal Imaging Device

  • Baek, Tae Seong;Chung, Eun Ji;Son, Jaeman;Yoon, Myonggeun
    • 한국의학물리학회지:의학물리
    • /
    • 제28권2호
    • /
    • pp.54-60
    • /
    • 2017
  • This study was designed to measure transit dose with an electronic portal imaging device (EPID) in eight patients treated with intensity modulated radiotherapy (IMRT), and to verify the accuracy of dose delivery to patients. The calculated dose map of the treatment planning system (TPS) was compared with the EPID based dose measured on the same plane with a gamma index method. The plan for each patient was verified prior to treatment with a diode array (MapCHECK) and portal dose image prediction (PDIP). To simulate possible patient positioning errors during treatment, outcomes were evaluated after an anthropomorphic phantom was displaced 5 and 10 mm in various directions. Based on 3%/3 mm criteria, the $mean{\pm}SD$ passing rates of MapCHECK, PDIP (pre-treatment QA) for 47 IMRT were $99.8{\pm}0.1%$, $99.0{\pm}0.7%$, and, respectively. Besides, passing rates using transit dosimetry was $90.0{\pm}1.5%$ for the same condition. Setup errors of 5 and 10 mm reduced the mean passing rates by 1.3% and 3.0% (inferior to superior), 2.2% and 4.3% (superior to inferior), 5.9% and 10.9% (left to right), and 8.9% and 16.3% (right to left), respectively. These findings suggest that the transit dose-based IMRT verification method using EPID, in which the transit dose from patients is compared with the dose map calculated from the TPS, may be useful in verifying various errors including setup and/or patient positioning error, inhomogeneity and target motions.

가스치환포장과 감마선조사 병용 처리한 최소가공 무의 미생물학적 안전성 (Microbiological Safety of Minimally Processed White Radish in Modified Atmosphere Packaging Combined with Irradiation Treatment)

  • 김재경;조철훈;김현주;이주운;황한준;변명우
    • 한국식품과학회지
    • /
    • 제37권1호
    • /
    • pp.11-14
    • /
    • 2005
  • 최소가공 무의 미생물학적 안전성을 확보하고 품질을 보존하기 위하여 가스치환포장과 감마선 조사를 병용 처리하여 4에서 2주간 저장하면서 일반 호기성 미생물, 대장균군, 젖산균 및 pH의 변화를 각각 조사하였다. 일반 호기성 미생물의 변화를 관찰한 결과 저장기간과 포장 방법에 관계없이 감마선 조사에 의해 유의적으로 줄어들었으며 처리 당일의 경우 2kGy의 방사선 조사에 의해 $CO_{2}$$CO_{2}/N_{2}$ 포장구가 함기 포장구 보다 유의하게 미생물을 감소하였다. 대장균군 역시 저장기간과 포장 방법에 관계없이 감마선 조사에 의해 유의적으로 줄어들었으며 젖산균도 저장기간과 포장 방법에 관계없이 감마선 조사에 의해 유의적으로 줄어들었다. pH의 변화에 있어서는 감마선 조사와 포장방법에 의한 유의한 차이를 보이지는 않았지만 가스치환포장을 하였을 때 pH가 낮아지는 경향을 보였으며 저장기간 동안 pH 증가하였다. 이러한 결과로 볼 때 최소가공 무의 미생물학적 안전성을 확보하고 품질을 보존하기 위해서는 2kGy의 감마선 조사와 가스치환포장의 병용처리가 효과적이라 사료된다.

Prostate Cancer 환자에 대한 One Arc와 Two Arc VMAT Plan의 선량 측정 비교 분석 (Dosimetric Comparison of One Arc & Two Arc VMAT Plan for Prostate cancer patients)

  • 김병찬;김종덕;김효중;박호춘;백정옥
    • 대한방사선치료학회지
    • /
    • 제30권1_2호
    • /
    • pp.107-116
    • /
    • 2018
  • 목 적 : IMRT는 일반적인 3차원 방사선 치료방법보다 Prostate 주변 중요장기(OAR)에 대한 방사선 부작용을 줄이고 Prostate Cancer에 더 많은 선량을 투여할 수 있기 때문에 Prostate Cancer Therapy에 광범위하게 사용되었다. 장비 및 치료 기술의 많은 진보로 인하여 최근에는 체적 변조 아크 치료(VMAT)가 널리 사용되어지고 있으며, VMAT은 IMRT에 비해 치료 시간을 최대 55 % 단축시킬 수 있어 치료 중 움직임에 대한 오차를 최소화 할 수 있는 장점이 있다. 대상 및 방법 : 본 실험에서는 Prostate Cancer 환자 10명에 대해 LN가 포함된 치료 Group 5명과, LN가 포함되지 않는 Group 5명으로 1 Arc와 2 Arc 치료 계획 방법을 총 4 Group으로 분류하여 MU, DVH값들을 비교 분석 하였고, ArcCHECK과 MapCHECK을 사용하여 DQA 관련 측정을 수행했다. 결 과 : Prostate patients의 Target과 OAR 선량분포 결과는 다음과 같다. $D_{max}$는 4개 Group이 100~110 % 범위로 나타났으며, Hot spot인 110 % 이상은 보이지 않았다. LN가 없는 Only-Prostate($P_1$, $P_2$)의 Target $D_{98%}$ 분포도는 1 Arc plan($P_1$)보다 2 Arc plan($P_2$)에서 조금 더 좋은 결과 값을 보였다. LN-Prostate($P_{L1}$, $P_{L2}$) Group에서의 Target $D_{98%}$ 분포도는 1 Arc plan($P_{L1}$)보다 2 Arc plan($P_{L2}$)이 더 좋은 결과 값을 보였고, 1 Arc plan($P_{L1}$)에서는 Target $D_{98%}$의 처방 선량 값에 도달하지 못했다. 또한, OAR에서는 Only-Prostate($P_1$, $P_2$) Group에서 1 Arc와 2 Arc Plan 모두 처방 선량 값에 만족했고, LN-Prostate 1 Arc($P_{L1}$) Plan은 OAR의 처방 선량치보다 높은 선량 값을 보였다. DQA 측정에서 계산된 ArcCHECK과 MapCHECK의 Gamma evaluation pass rate는 99 %보다 조금 더 높았고, CC04 Ion-chamber를 이용한 점 선량(Point Dose) 측정값의 평균 오차 범위는 1 % 미만이었다. 결 론 : 본 연구에서 분석한 결과, Only-Prostate($P_1$, $P_2$) Group의 경우는 두 plan의 선량이 비슷했지만, 치료시간과 MU값 등을 고려했을 때 1 Arc 치료 방법($P_1$)이 더 적합하였으며, LN-Prostate($P_{L1}$, $P_{L2}$) Group에서는 Target $D_{98%}$와 OAR의 처방 선량에 만족하는 2 Arc 치료 방법($P_{L2}$)이 더 적합한 결과를 보였다.

  • PDF

체적변조회전치료에서 Hybrid Optimized VMAT Phantom (HOVP)을 이용한 실시간 환자 맞춤형 정도관리를 위한 예비연구 (A Pilot Research for Real-Time Specific Patient Quality Assurance Using the Hybrid Optimized Vmat Phantom (Hovp) in Volume Modulated Arc Therapy)

  • 허현도;최상현;김우철;김헌정;김금배;김성훈;조삼주;민철기;조광환;이상훈;이석;심장보;신동오;지영훈
    • 한국의학물리학회지:의학물리
    • /
    • 제22권4호
    • /
    • pp.206-215
    • /
    • 2011
  • 다엽콜리메이터, 겐트리회전, 선량율 등에서 형성되는 플루언스 맵을 이용하여 환자 맞춤형 치료 선량검증이 가능한지 알아보았다. 플루언스 맵은 2D 배열 검출기로 측정하였고, 동일 치료계획을 팬톰 내에서 이온전리함, 필름, 유리선량계 등을 이용하여 측정 비교하였다. 목표점에서 체적감마인자(volume gamma index, 3%, 3 mm)기준에 통과율은 $85.22%{\pm}1.7$(RT_target), $89.96%{\pm}2.15$였고, G4는 $95.14%{\pm}1.18$이었다. 선량 전달 오차는 선량이 급격히 변화는 영역(G1, G2, G3)과 주요장기(G4)에서 각각 $11.72%{\pm}0.531$, $-11.47%{\pm}0.991$, $7.81%{\pm}0.857$, $-4.14%{\pm}0.761$이었다. 이온전리함 측정값의 상대오차는 각각 평균 $-1.02%{\pm}0.222$ (Rt_target), $0.96%{\pm}0.294$ (Lt_target)이었다. 필름의 감마인자(3%, 3 mm) 기준 평균 통과율은 $92.59%{\pm}3.312$이었다. 유리선량계 상대 오차는 8.3% (G1), -5.4% (G2), 7.2% (G3), 6.1% (G4)이었다. 체적변조회전방사선 치료(VMAT)시 실시간 플루언스 맵 측정을 통한 실시간 환자 맞춤형 선량 검증이 가능할 것으로 사료되었다.