• 제목/요약/키워드: Radiation loss

검색결과 958건 처리시간 0.022초

개인선량계 분실 사례 및 분실 방지 방안 조사 (Investigation of Personal Dosimeter Loss Case and Measures to Prevent Loss)

  • 박성우;박현식;박영재;이경재;오기백;이성하;김민석;박주언;원문희
    • 핵의학기술
    • /
    • 제27권1호
    • /
    • pp.66-70
    • /
    • 2023
  • Purpose It is intended to improve the management efficiency of personal dosimeters by analyzing and sharing personal dosimeter loss cases and loss prevention measures. Materials and Methods From 2017 to 2021, data on the number of lost personal dosimeters were collected at large hospitals, and the number of personal dosimeters issued and lost were investigated. Results In order to prevent loss by institution, methods such as the use of auxiliary rings, contact stickers and dosimeter necklaces were implemented. Conclusion Hospitals are a business that frequently changes clothes, such as surgical gowns and work clothes, so there is a lot of loss. In addition, it was confirmed that the loss rate increases as the number of personal dosimeters issued increases.

  • PDF

Reproduction strategy of radiation data with compensation of data loss using a deep learning technique

  • Cho, Woosung;Kim, Hyeonmin;Kim, Duckhyun;Kim, SongHyun;Kwon, Inyong
    • Nuclear Engineering and Technology
    • /
    • 제53권7호
    • /
    • pp.2229-2236
    • /
    • 2021
  • In nuclear-related facilities, such as nuclear power plants, research reactors, accelerators, and nuclear waste storage sites, radiation detection, and mapping are required to prevent radiation overexposure. Sensor network systems consisting of radiation sensor interfaces and wxireless communication units have become promising tools that can be used for data collection of radiation detection that can in turn be used to draw a radiation map. During data collection, malfunctions in some of the sensors can occasionally occur due to radiation effects, physical damage, network defects, sensor loss, or other reasons. This paper proposes a reproduction strategy for radiation maps using a U-net model to compensate for the loss of radiation detection data. To perform machine learning and verification, 1,561 simulations and 417 measured data of a sensor network were performed. The reproduction results show an accuracy of over 90%. The proposed strategy can offer an effective method that can be used to resolve the data loss problem for conventional sensor network systems and will specifically contribute to making initial responses with preserved data and without the high cost of radiation leak accidents at nuclear facilities.

냉장고 가스켓 주위의 복사열전달 효과에 관한 연구 (A Study on the Radiation Heat Transfer Effect near a Refrigerator Gasket)

  • 하지수
    • 한국산학기술학회논문지
    • /
    • 제16권3호
    • /
    • pp.1605-1610
    • /
    • 2015
  • 본 논문은 냉장고의 열손실의 약 30%를 차지하고 있는 가스켓 주위의 열전달 해석시 복사열전달을 고려하지 않은 경우와 고려한 경우가 많은 차이가 있어서 가스켓 주위의 열전달 해석시 복사열전달 고려 여부에 따른 열손실 효과를 살펴보는 연구이다. 이를 위해 가스켓 주위를 단순화한 형상으로 모델링하여 열전달 전산해석을 수행하였다. 본 연구를 통해서 가스켓 내부의 공기층을 단순히 전도열전달만 고려한 경우 열손실이 $25.6W/m^2$이고 복사열전달을 함께 고려한 경우 $55.0W/m^2$로 약 2.2배 크게 나타남을 알 수 있었다. 가스켓 내부에 복사열전달 차단판을 0에서 7개로 변화하면서 복사열전달 저감 효과를 살펴본 결과 차단판 개수가 증가하여 7개 인 경우는 설치하지 않은 경우에 비하여 열손실이 $55.0W/m^2$에서 $36.7W/m^2$로 33% 감소함을 알 수 있었다. 또한 같은 개수의 복사 차단판일 경우는 냉장고 내부와 외부에 치우치는 쪽으로 설치하는 것이 가스켓의 가운데에 설치하는 것 보다 효과적임을 알 수 있었다.

Radiation Effects on ${\gamma}$-Ray Irradiated Ethylene Propylene Rubber using Dielectric Analysis

  • Kim, Ki-Yup;Ryu, Boo-Hyung;Lee, Chung;Lim, Kee-Joe
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제3C권2호
    • /
    • pp.48-54
    • /
    • 2003
  • To evaluate the radiation degradation of ethylene propylene rubber (EPR), radiation effects on EPR were investigated by using dielectric analysis and thermal-gravimetric analysis. Permittivity, loss factor, tan$\delta$, and thermal decomposition temperature were observed for ${\gamma}$-ray irradiated EPR. As the radiation dose was increased, the peak temperature of the loss factor and tans of EPR were increased and loss factor and tan$\delta$ at peak temperature were decreased. Activation energies were calculated using loss factor and thermal decomposition for ${\gamma}$-ray irradiated EPR as well. The trends of both calculated activation energies showed the same tendencies as radiation dose was increased.

감마선 조사에 의한 광섬유의 전송손실 특성변화에 관한 연구 (A Study on the Radiation-Induced Loss of Optical Fiber by ${\gamma}$-ray Irradiation)

  • 김웅기;이용범;이종민
    • 대한전자공학회논문지
    • /
    • 제27권4호
    • /
    • pp.604-611
    • /
    • 1990
  • One of the confronting problems in using optical fibers under radiation environments is producing of color centers in optical materials due to nuclear radiation. These centers increase transmission loss by absorbing propagating light. In this study, the radiation effects on optical fiber are studied theoretically. Also, optical attenuation induced by \ulcorner-ray irradiation from Co**60 for single mode and multimode optical fibers is measured at the optical wavelength of 0.85\ulcorner and 1.3\ulcorner, and the results are analyzed. Gammaray is irradiated for 5hours at the rate of 300rads/min, which is corresponding to 90 krads of integrated dose. In case of multimode optical fibers, the induced loss at 0.85\ulcorner wavelength has been twice higher than that at 1.3\ulcorner. The loss in multimode fibers has been significantly larger by 7-20 times than that in single mode fibers, dependently on fiber materials at 1.3\ulcorner.

  • PDF

손실 기판을 이용한 금속 부착형 RFID 태그 안테나의 복사 효율 향상 (Radiation Efficiency Improvement of RFID Tag Antenna for Metallic Objects Printed on Lossy Substrate)

  • 손해원;최원규;최길영
    • 한국전자파학회논문지
    • /
    • 제19권11호
    • /
    • pp.1265-1271
    • /
    • 2008
  • 본 논문에서는 FR4와 같은 저가의 고손실 기판을 이용하여 금속 부착형 태그 안테나를 설계하는 새로운 방법을 제안한다. 제안한 설계 방법은 유전 손실(dielectric loss)에 따른 기판 손실(substrate loss)을 크게 감소시킴으로써, 태그 안테나의 복사 효율(radiation efficiency)을 기존의 평면 역 F 안테나(planar inverted-F antenna: PIFA)에 비하여 2배 이상 향상시킨다. 본 논문에서는 제안한 방법에 따른 안테나의 등가 회로 모델을 정립하고 이를 체계적으로 분석하였으며, 시제품을 제작 및 측정하여 제안한 방법의 우수성을 입증하였다.

고압하에서 수소 확산화염의 소염에 미치는 복사 열손실 효과에 관한 수치적 연구 (A Numerical Study on Effect of Radiative Heat Loss on Extinction of Hydrogen Diffusion Flames at High Pressure)

  • 오태균;손채훈
    • 대한기계학회논문집B
    • /
    • 제32권5호
    • /
    • pp.351-358
    • /
    • 2008
  • Extinction characteristics of hydrogen-air diffusion flames at various pressures are investigated numerically by adopting counterflow flame configuration as a model flamelet. Especially, effect of radiative heat loss on flame extinction is emphasized. Only gas-phase radiation is considered here and it is assumed that $H_2O$ is the only radiating species. Radiation term depends on flame thickness, temperature, $H_2O$ concentration, and pressure. From the calculated flame structures at various pressures, flame thickness decreases with pressure, but its gradient decreases at high pressure. Flame temperature and mole fraction of $H_2O$ increase slightly with pressure. Accordingly, as pressure increases, radiative heat loss becomes dominant. When radiative heat loss is considered, radiation-induced extinction is observed at low strain rate in addition to transport-induced extinction. As pressure increases, flammable region, where flame is sustained, shifts to the high-temperature region and then, shrunk to the point on the coordinate plane of flame temperature and strain rate. The present numerical results show that radiative heat loss can reduce the operating range of a combustor significantly.

접시형 태양열 집광시스템용 흡수기의 열손실 해석 (An Analysis of Heat Losses from Receivers for a Multifaceted Parabolic Solar Collector)

  • 류시열;서태범;강용혁
    • 태양에너지
    • /
    • 제20권3호
    • /
    • pp.61-73
    • /
    • 2000
  • Heat losses from receivers for a dish-type solar energy collecting system are numerically investigated. The analytical method for predicting conductive heat loss from a cavity receiver is used. The Stine and McDonald Model is used to estimate convective heat loss. Two kinds of techniques for the radiation analysis are used. The Net Radiation Method that is based on the radiation heat balance on the surface is used to calculate the radiation heat transfer rate from the inside surface of the cavity receiver to the environment. The Monte-Carlo Method that is the statistical approach is adopted to predict the radiation heat transfer rate from the reflector to the receiver. Based on the heat loss analysis, the performance of two different receivers for multifaceted parabolic solar collectors with several flat facets can be estimated, and the optimal facet size is obtained.

  • PDF

Evaluation of the Efficacy of Zoledronic Acid and Amifostine on Radiation-induced Bone Loss in Mice

  • Kim, Jinwook;Lee, Sueun;Kang, Sohi;Moon, Changjong;Kim, Jong-Choon;Jung, Uhee;Jo, Sung-Kee;Jang, Jong-Sik;Kim, Sung-Ho
    • Journal of Radiation Protection and Research
    • /
    • 제41권3호
    • /
    • pp.253-259
    • /
    • 2016
  • Background: This study investigated the effects of zoledronic acid (ZA) on radiation-induced bone loss in C3H/HeN mice. Materials and Methods: C3H/HeN mice were divided into sham control and three irradiated groups (3 Gy, gamma ray). The irradiated mice were treated for 12 weeks with vehicle, amifostine (intraperitoneal injection), or ZA (subcutaneous injection). Grip strength, uterus weight, and serum alkaline phosphatase (ALP), and tartrate-resistant acid phosphatase (TRAP) levels were measured. Tibiae were analyzed using micro-computed tomography. Results and Discussion: Treatment of ZA ($100{\mu}g{\cdot}kg^{-1}{\cdot}week^{-1}$) significantly preserved trabecular bone volume, trabecular thickness, trabecular number, trabecular separation, bone mineral density of proximal tibia metaphysic, and cortical bone volume, but did not alter the uterus weight of the mice. The administration of ZA for 12 weeks lowered serum ALP and TRAP levels in irradiated mice, suggesting that ZA can reduce the bone turnover rate in mice. No differences were apparent between the amifostine-treated group and the irradiation control group. Conclusion: The results indicate that ZA can prevent radiation-induced bone loss in mice.