• Title/Summary/Keyword: Radiation heat

Search Result 1,421, Processing Time 0.027 seconds

Effects of CO2 on Heat Transfer from Oxygen-Enriched Hydrogen Flame (이산화탄소가 수소 산소부화 화염의 열전달에 미치는 영향)

  • Lee, Chang-Yeop;Choi, Joon-Won;Baek, Seung-Wook
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.8 s.227
    • /
    • pp.937-944
    • /
    • 2004
  • An experimental study has been conducted to evaluate the effects of $CO_2$ on heat transfer from oxygen-enriched hydrogen flame. Experiments were performed on flames stabilized by a co-flow swirl burner, which was mounted on top of the furnace. Five different oxidizer compositions were prepared by replacing $N_2$ with $CO_2$. In a steady state, the total as well as radiative heat flux from the flame to the wall of furnace have been measured using a heat flux meter. Temperature distribution in furnace also has been measured and compared. By increasing $CO_2$ proportion in the oxidizer, the convection played a more significant role rather than radiation. Overall temperature in the furnace was seen to be decreased, while the total heat flux has increased.

An Experimental Study on Comparing Solar Heat Shading Performances in Accordance with the Type of Internal Blinds in the Summer (하절기 내측 블라인드의 유형별 일사차폐성능 비교 실측연구)

  • Park, Eun-Mi;Choi, Dong-Ho
    • Journal of the Korean Solar Energy Society
    • /
    • v.36 no.4
    • /
    • pp.1-9
    • /
    • 2016
  • The purpose of this study was to compare heat shading performance of various blind types in summer. 4 types of blinds were employed and the results are summarized as follows: 1) There were significant differences in indoor thermal environment and heat shading performance between different heat shading devices, and functional blinds demonstrated relatively superior heat shading performance. 2) Indoor long wave radiation influx measures were lowest for the coating roll blind (Blind B), followed by the coating venetian blind (Blind C), the venetian blind (Blind A), the roll blind, and not having any blinds at all. 3) Such examination results carry implications to reduce cooling load and enhance the indoor environment.

A Numerical Study of Opposed Nonpremixed Tubular Flames with Radiative Heat Loss (복사열손실이 있는 비예혼합 튜브형 화염에 관한 수치 해석적 연구)

  • Bak, Hyun Su;Yoo, Chun Sang
    • 한국연소학회:학술대회논문집
    • /
    • 2015.12a
    • /
    • pp.247-250
    • /
    • 2015
  • The characteristics of opposed nonpremixed tubular flames with radiation heat loss are investigated using linear stability analysis and 2-D numerical simulations. Two extinction limits, as the $Damk{\ddot{o}}hler$ number is small or large, are confirmed using finite difference method with a simple continuation method. It is verified that the results of linear stability analysis predict the number of flame cells and the critical Da starting cellular instability or amplification of temperature near both extinction limits with good resolution.

  • PDF

Effects of Surface Radiation on the Unsteady Natural Convection in a Rectangular Enclosure

  • Baek, Seung-Wook;Kim, Taig-Young
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.3 no.1
    • /
    • pp.95-104
    • /
    • 2002
  • Numerical solution of the full Navier-Stokes equation as well as the energy equation has been obtained for the unsteady natural convection in a rectangular enclosure. One side wall was maintained at very high temperature simulating fires. Especially the effect of surface radiation was taken into account. While the enclosed air was assumed to be transparent, the internal walls directly interacted one another through the surface radiation. Due to a significant temperature difference in the flow field, the equation of state was used instead of the Boussinesq approximation. It was found that the rapid heating of the adiabatic ceiling and floor by the incoming radiation from the hot wall made the evolution at thermo-fluid field highly unstable in the initial period. Therefore, the secondary cells brought about at the floor region greatly affected the heat transfer mechanism inside the enclosure. The heat transfer rate was augmented by the radiation, resulting in requiring less time for the flow to reach the steady state. At the steady state neglecting radiation two internal hydraulic jumps were clearly observed in upper/left as well as in lower/right comer. However, the hydraulic jump in the lower/right comer could not be observed for the case including radiation due to its high momentum flow over the bottom wall. Radiation resulted in a faster establishment of the steady state phenomena.

Analysis of the Waymth Retentivity of Waddings (솜의 보온특성분석)

  • Chang Shin Yae;Kahng He Won;Kim Sung Reon
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.1 no.1
    • /
    • pp.25-29
    • /
    • 1977
  • The warmth retentivity of natural and syntheic waddings as bedding stuff, and further, the machanism of heat transmission through conduction, radiation and convection were analysed. The materials used were cotton, silk, and wool as natural waddings, and polyamide, polyester, regular acrylic, conjugate acrylic, regular polyprepylene and conjugate polypropylene as synthetic waddings. The results of this study are as follow: 1. The warmth retentivity is highest in silk. Following silk in descending order is cotton, conjugate acrylic, polyester, regular acrylic, wool, polyamide, conjugate polypropylene and regular polypropylene. There is not any significant relationship between warmth retentivity and the conductivity of the fibers. 2. Transmission by radiation through the fiber waddings is highest in conjugate polypropylene. Following conjugate polypropylene in descending order is regular polypropylene. polyester. polyamide, conjugate acrylic, regular acrylic, wool, cotton, and silk. This is seen to be in nearly reversed order to the abovementioned order of warmth retentivity. In this respect, warmth retentivity with loose fibreous material as in the case of bedding stuff is primarily affected by the interceptive function of the fibers in heat radiation. 3. Warmth retentivity becomes lower with increasing air content of the waddings. This is because heat transmission by radiation incrases as air content increases. The air content increase is due to the fact that the air is unable to intercept heat radiation. In addition, heat transmission accelates in proportion to the increase in convection as the air gap enlarges.

  • PDF

A Study on the Change of Indoor Thermal Environment According to the location of Blinds (블라인드 설치 위치에 따른 실내열환경 변화에 관한 연구)

  • Hwang, Deuk-Soo;Lee, Kyung-Hee
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.5
    • /
    • pp.113-118
    • /
    • 2011
  • In order to prevent incoming solar radiation, it is necessary to study about blinds' blocking out effects of heat that are installed at the balcony at an apartment house. To figure out the heating effects from the windows, a study for indoor thermal environment according to the location of blinds is also needed. In order to find out the changes of indoor thermal environment, we'll compare models of a house building with or without Venetian blinds: one place has an extended living room removing a balcony and another one has a normal balcony. The result is as follows. Without blinds, the place with an extended living room has benefits for saving heat compare to the place with a normal balcony. It's because the warm air heated by the incoming solar radiation moves into the living room through convection current and radiation which causes an increase of the indoor temperature. At an extended living room, the temperature difference from outside and inside, when blinds were installed inside, was $1.9^{\circ}C$ while it was $0.6^{\circ}C$ when the blinds were installed at outside of the balcony. It is evaluated that setting up the blind outside prevents much heat. At the space with a normal balcony, installing blinds at living room windows can save much heat compare to installing blinds at windows at the balcony. The indoor temperature was low when blinds were installed. It can be said that blinds block heat from the incoming solar radiation. Moreover, when blinds are installed, there is a big change of indoor temperature due to the radiation from the blinds' slat and convective activities in between the blinds and windows. This also has to be considered.

Heat Transfer and Combustion Characteristics and Performance of U type Radiation Tube Burner with fin (핀 부착 U형 복사튜브 버너의 열전달 및 연소성능 실험)

  • Lee, Hyun-Chan;You, Hyun-Seok;Lee, Joong-Seong
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.516-521
    • /
    • 2001
  • Present study deals with combustion characteristics and performance of U type radiation tube burner with fin which combustion capacity is 30,000kcal/hr and the maximum capacity of supply fuel is $30Nm^{3}/hr$. Temperature difference of radiation tube is about $173^{\circ}C$ at 25% capacity and this show relatively small temperature difference for convenient type. Thermal efficiency is satisfactory as $72{\sim}81%$. Also, radiative efficiency of radiation tube is $52{\sim}73%$. The efficiency of heat exchanger is $27{\sim}37%$. Therefore, radiative efficiency is improved to $1{\sim}10%$ after installing fin.

  • PDF

Thermal Analysis of a Cryochamber for an Infrared Detector Considering a Radiation Shield (적외선 검출기용 극저온 챔버에서 복사 차폐막을 고려한 열해석)

  • Kim Young-Min;Kang Byung-Ha
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.8
    • /
    • pp.672-677
    • /
    • 2006
  • The steady cooling characteristics of a cryochamber for infrared (IR) detector have been investigated analytically, considering radiation shields. The thermal modeling considers the conduction heat transfer through cold finger, the gaseous conduction due to out-gassing, and the radiation heat transfer. The cooling load of the cryochamber is obtained by using a fin equation. The results obtained indicate that the gaseous conduction plays an important role in determining the steady cooling load. The steady cooling load is increased as the gas pressure is increased. It is also found that the cooling load is substantially decreased with a radiation shield. The most thermal load of a cryochamber occurs through the cold finger.

Mathematical Description and Prognosis of Cell Recovery after Thermoradiation Action

  • Komarova, Ludmila N.;Kim, Jin-Kyu;Petin, Vladislav G.
    • Korean Journal of Environmental Biology
    • /
    • v.26 no.1
    • /
    • pp.1-7
    • /
    • 2008
  • A mathematical model for the synergistic interaction of physical and chemical environmental agents was suggested for quantitative prediction of irreversibly damaged cells after combined exposures. The model took into account the synergistic interaction of agents and was based on the supposition that additional effective damages responsible for the synergy are irreversible and originated from an interaction of ineffective sublesions. The experimental results regarding the irreversible component of radiation damage of diploid yeast cells simultaneous exposed to heat with ionizing radiation ($^{60}Co$) or UV light (254 nm) are presented. It was shown that the cell ability of the liquid holding recovery decreased with an increase in the temperature, at which the exposure was occurred. A good correspondence between experimental results and model prediction was demonstrated. The importance of the results obtained for the interpretation of the mechanism of synergistic interaction of various environmental factors is discussed.

RADIATION HEAT TRANSFER IN HORIZONTAL CYLINDRICAL ANNULUS (수평원관 사이 환상유로에서의 복사열전달 연구)

  • Han, C.Y.;Park, E.S.;Jeon, H.Y.;Yu, M.J.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.75-77
    • /
    • 2011
  • Thermofluid flow analysis is major subject in most computational fluid dynamics applications. Accompanying convective and conductive heat transport phenomena, radiation plays an important role in high temperature operating systems. Cares in which the radiation dominates are found in such systems as boilers, furnaces, rocket engines, etc. In this paper the finite-volume method (FVM) are employed to simulate two-dimensional radiation problems in concentric and eccentric horizontal cylindrical annuli with general body-fitted coordinates. In that case the simplest and intuitive remedies are proposed for mitigation of ray effect.

  • PDF