• 제목/요약/키워드: Radiation emergency

검색결과 215건 처리시간 0.029초

Virtual calibration of whole-body counters to consider the size dependency of counting efficiency using Monte Carlo simulations

  • Park, MinSeok;Kim, Han Sung;Yoo, Jaeryong;Kim, Chan Hyeong;Jang, Won Il;Park, Sunhoo
    • Nuclear Engineering and Technology
    • /
    • 제53권12호
    • /
    • pp.4122-4129
    • /
    • 2021
  • The counting efficiencies obtained using anthropomorphic physical phantoms are generally used in whole-body counting measurements to determine the level of internal contamination in the body. Geometrical discrepancies between phantoms and measured individuals affect the counting efficiency, and thus, considering individual physical characteristics is crucial to improve the accuracy of activity estimates. In the present study, the counting efficiencies of whole-body counting measurements were calculated considering individual physical characteristics by employing Monte Carlo simulation for calibration. The NaI(Tl)-based stand-up and HPGe-based bed type commercial whole-body counters were used for calculating the counting efficiencies. The counting efficiencies were obtained from 19 computational phantoms representing various shapes and sizes of the measured individuals. The discrepancies in the counting efficiencies obtained using the computational and physical phantoms range from 2% to 33%, and the results indicate that the counting efficiency depends on the size of the measured individual. Taking into account the body size, the equations for estimating the counting efficiencies were derived from the relationship between the counting efficiencies and the body-build index of the subject. These equations can aid in minimizing the size dependency of the counting efficiency and provide more accurate measurements of internal contamination in whole-body counting measurements.

Measurement uncertainty analysis of radiophotoluminescent glass dosimeter reader system based on GD-352M for estimation of protection quantity

  • Kim, Jae Seok;Park, Byeong Ryong;Yoo, Jaeryong;Ha, Wi-Ho;Jang, Seongjae;Jang, Won Il;Cho, Gyu Seok;Kim, Hyun;Chang, Insu;Kim, Yong Kyun
    • Nuclear Engineering and Technology
    • /
    • 제54권2호
    • /
    • pp.479-485
    • /
    • 2022
  • At the Korea Institute of Radiological and Medical Sciences, physical human phantoms were developed to evaluate various radiation protection quantities, based on the mesh-type reference computational phantoms of the International Commission on Radiological Protection. The physical human phantoms were fabricated such that a radiophotoluminescent glass dosimeter (RPLGD) with a Tin filter, namely GD-352M, could be inserted into them. A Tin filter is used to eliminate the overestimated signals in low-energy photons below 100 keV. The measurement uncertainty of the RPLGD reader system based on GD-352M should be analyzed for obtaining reliable protection quantities before using it for practical applications. Generally, the measurement uncertainty of RPLGD systems without Tin filters is analyzed for quality assurance of radiotherapy units using a high-energy photon beam. However, in this study, the measurement uncertainty of GD-352M was analyzed for evaluating the protection quantities. The measurement uncertainty factors in the RPLGD include the reference irradiation, regression curve, reproducibility, uniformity, energy dependence, and angular dependence, as described by the International Organization for Standardization (ISO). These factors were calculated using the Guide to the Expression of Uncertainty in Measurement method, applying ISO/ASTM standards 51261(2013), 51707(2015), and SS-ISO 22127(2019). The measurement uncertainties of the RPLGD reader system with a coverage factor of k = 2 were calculated to be 9.26% from 0.005 to 1 Gy and 8.16% from 1 to 10 Gy. A blind test was conducted to validate the RPLGD reader system, which demonstrated that the readout doses included blind doses of 0.1, 1, 2, and 5 Gy. Overall, the En values were considered satisfactory.

저선량과 고선량 측정구간 변환이 가능한 모바일 방사선 측정시스템 개발 및 평가 (Development and Evaluation of a Mobile Environmental Radiation Measurement System That Can Switch between Low and High Dose Measurement Sections)

  • 이홍연;한상준;김보길;이건주;김석현;김정훈
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제45권1호
    • /
    • pp.49-55
    • /
    • 2022
  • This study is to develop a mobile type environmental radiation measurement system for emergency response or environmental radiation monitoring of local governments near nuclear facilities. A mobile radiation measurement system can monitor radiation by field beyond the spatial constraints of a fixed environmental radiation monitor. If installed in local government infrastructure such as public transportation, environmental radiation can be monitored without additional manpower and measurement work. In addition, it is designed to enable monitoring and measurement of radiation from low to high doses as well as the environment in preparation for radioactive disasters such as nuclear power plant accidents. It is expected that this system will be utilized not only in normal times but also in the event of a radiation accident to improve the disaster prevention capabilities of local governments.

Air Leakage Analysis of Research Reactor HANARO Building in Typhoon Condition for the Nuclear Emergency Preparedness

  • Lee, Goanyup;Lee, Haecho;Kim, Bongseok;Kim, Jongsoo;Choi, Pyungkyu
    • Journal of Radiation Protection and Research
    • /
    • 제41권4호
    • /
    • pp.354-358
    • /
    • 2016
  • Background: To find out the leak characteristic of research reactor 'HANARO' building in a typhoon condition Materials and Methods: MELCOR code which normally is used to simulate severe accident behavior in a nuclear power plant was used to simulate the leak rate of air and fission products from reactor hall after the shutdown of the ventilation system of HANARO reactor building. For the simulation, HANARO building was designed by MELCOR code and typhoon condition passed through Daejeon in 2012 was applied. Results and Discussion: It was found that the leak rate is $0.1%{\cdot}day^{-1}$ of air, $0.004%{\cdot}day^{-1}$ of noble gas and $3.7{\times}10^{-5}%{\cdot}day^{-1}$ of aerosol during typhoon passing. The air leak rate of $0.1%{\cdot}day^{-1}$ can be converted into $1.36m^3{\cdot}hr^{-1}$, but the design leak rate in HANARO safety analysis report was considered as $600m^3{\cdot}hr^{-1}$ under the condition of $20m{\cdot}sec^{-1}$ wind speed outside of the building by typhoon. Conclusion: Most of fission products during the maximum hypothesis accident at HANARO reactor will be contained in the reactor hall, so the direct radiation by remained fission products in the reactor hall will be the most important factor in designing emergency preparedness for HANARO reactor.

Educational Program for Radiation Emergency Medicine at the Hirosaki University Graduate School of Health Sciences: A Training Course for Medical Personnel

  • Saito, Yoko;Nakamura, Toshiya;Urushizaka, Mayumi;Kitajima, Yu;Itaki, Chieko;Terashima, Shingo;Hosokawa, Yoichiro
    • Journal of Radiation Protection and Research
    • /
    • 제41권4호
    • /
    • pp.436-441
    • /
    • 2016
  • Background: Although nuclear disaster is considered rare, its effects are serious, and we must prepare a system to enable an effective response. Materials and Methods: Since 2010, we have been offering a two-day seminar to provide current nurses and radiological technologists with basic knowledge and train them in radiation emergency medicine (REM) techniques. This training offers lectures to deepen each specialty from the perspective of REM, as well as exercises on ways to handle irradiated and/or contaminated patients. Participants were expected to treat patients according to the concept of REM. Results and Discussion: All participants learn to assess and decontaminate contaminated wounds through drills. The questionnaire survey for participants indicated that participants were satisfied with this training and wanted to attend again. Conclusion: We believe that this training course will provide a valuable opportunity for medical professionals to gain knowledge and expertise in REM.

Second intercomparison on electron paramagnetic resonance (EPR) retrospective dosimetry in Korea using hydroxyapatite

  • HyoJin Kim;Jae Seok Kim;Byeong Ryong Park;Seongjae Jang;Han-Ki Jang;Ki-Taek Han;Hoon Choi;Jeongin Kim;In Jung Kim;Yunho Kim;Wi-Ho Ha;Jungil Lee;Yeong-Rok Kang
    • Nuclear Engineering and Technology
    • /
    • 제55권12호
    • /
    • pp.4576-4582
    • /
    • 2023
  • The Korea retrospective dosimetry (KREDOS)-electron paramagnetic resonance (EPR) group undertook an intercomparison investigation utilizing hydroxyapatite. This analysis involved four institutions: the Korea Institute of Radiological and Medical Sciences, Dongnam Institute of Radiological and Medical Sciences, Korean Association for Radiation Application, and Radiation Health Institute of Korea Hydro & Nuclear Power. Following the irradiation of the hydroxyapatite sample, the recorded build-up was analyzed. To validate the reliability of the EPR dosimetry findings and enhance its operational performance, a hydroxyapatite dose-response curve was plotted and dosimetry was performed for a blind sample. The proficiency of each laboratory was assessed by employing an interlaboratory comparison methodology. This involved a comparative analysis of the measurement results by calculating the relative bias, z-score, and En value. The results submitted by the participating laboratories demonstrated satisfactory ratings for doses of 1.006, 3.999, and 6.993 Gy. Following the second intercomparison, efforts to optimize their hydroxyapatite-EPR dosimetry systems are underway in the participating laboratories. The current assessment of hydroxyapatite dose yielded the foundational data required to establish the parameters of dental dosimetry. In future, the third intercomparison experiment will be conducted for exploring other materials.

Age-Specific Thyroid Internal Dose Estimation for Koreans

  • Kwon, Tae-Eun;Yoon, Seokwon;Ha, Wi-Ho;Chung, Yoonsun;Jin, Young Woo
    • Journal of Radiation Protection and Research
    • /
    • 제46권4호
    • /
    • pp.170-177
    • /
    • 2021
  • Background: The International Commission on Radiological Protection is preparing to provide reference dose coefficients for environmental radioiodine intake based on newly developed age-specific biokinetic models. However, the biokinetics of iodine has been reported to be strongly dependent on the dietary intake of stable iodine; for example, the thyroidal uptake of iodine may be substantially lower in iodine-rich regions than in iodine-deficient regions. Therefore, this study attempted to establish a system of age-specific thyroid dose estimation for South Koreans, whose daily iodine intakes are significantly higher than that of the world population. Materials and Methods: Korean age-specific biokinetic parameters and thyroid masses were derived based on the previously developed Korean adult model and the Korean anatomical reference data for adults, respectively. This study complied with the principles used in the development of age-specific biokinetic models for world population and used the ratios of baseline values for each age group relative to the value for adults to derive age-specific values. Results and Discussion: Biokinetic model predictions based on the Korean age-specific parameters showed significant differences in iodine behaviors in the body compared to those predicted using the model for the world population. In particular, the Korean age-specific thyroid dose coefficients for 129I and 131I were considerably lower than those calculated for the world population (25%-76% of the values for the world population). Conclusion: These differences stress the need for Korean-specific internal dose assessments for infants and children, which can be achieved by using the data calculated in this study.

방사선비상시 내부피폭 신속 분류를 위한 휴대용 NaI 검출기의 계측효율 전산모사 (Simulation of Counting Efficiencies of Portable NaI Detector for Rapid Screening of Internal Exposure in Radiation Emergencies)

  • 하위호;유재룡;윤석원;박민정;김종경
    • Journal of Radiation Protection and Research
    • /
    • 제40권4호
    • /
    • pp.211-215
    • /
    • 2015
  • 원자력사고 등의 방사선비상시 환경으로 누출된 방사성물질은 일반인의 내부피폭을 야기할 수 있다. 특히 감마선 방출핵종의 내부피폭의 경우 전신계수기가 널리 사용되지만 현장에서 신속히 내부피폭을 분류하는 용도로는 부적합하다. 본 연구에서는 휴대용 감마스펙트로메터를 비상시 내부피폭 신속분류에 적용하기 위하여 몬테카를로 전산모사 방법을 이용하여 NaI 검출기의 계측효율을 BOMAB 팬텀의 크기별로 평가하였다. 두 가지 측정 지오메트리에서 계측효율을 비교한 결과 앉은 모델에서의 계측효율이 서 있는 모델에 비해 약 1.1배 높은 계측효율을 나타내었다. 하지만 측정 지오메트리에 의한 계측효율 차이보다 신체크기에 따른 계측효율 차이가 크게 발생하는 것을 확인하였다. 특히 신체크기가 작은 4세 팬텀의 경우 표준남성과 비교하면 약 2.4~3.1배의 높은 계측효율을 나타내어 신체크기가 상이한 일반인을 대상으로 내부피폭을 모니터링할 경우 반드시 계측효율에 대한 고려가 필요한 것으로 확인되었다.

중증외상환자의 전산화단층촬영 및 중재술에 의한 방사선 유효선량 및 생애 귀속위험도 (Effective Radiologic Doses and Lifetime Attributable Risks in Patients with Trauma Critical Pathway Activation)

  • 이원효;공태영;김승환;유제성;박유석;이재길;정성필
    • Journal of Trauma and Injury
    • /
    • 제26권3호
    • /
    • pp.198-206
    • /
    • 2013
  • Purpose: This study was performed to calculate and analyze the effective radiation doses from computed tomography (CT) and radiologic intervention in patients in the emergency department (ED) with trauma critical pathway (CP) activation and further to estimate the lifetime attributable risks (LARs) for the incidence of and mortality from cancers induced by the radiation dose. Methods: Through a retrospective electrical chart review of 104 injured patients who trauma critical pathway were activated from November 2012 to March 2013, we calculated effective radiologic doses by taking the product of the dose-linear product of the scan and the conversion coefficient. After a determination of the image results, we divided the patients into two groups, negative or positive, and calculated the effective dose for each group. With these results, we estimated the LARs for the incidence of and the mortality from cancers by using the table in the Biologic Effects of Ionizing Radiation (BEIR)-VII report. Results: A total of 76 patients were enrolled. The mean age was $49.0{\pm}8.5$ years. The mean injury severity score (ISS) was $12.7{\pm}8.4$. The cumulative effective dose (CED) for individual patients varied from 2.8 mSv to 238.8 mSv, and the mean was $47.6{\pm}39.9$ mSv. The CED in patients with an $ISS{\geq}16$($63.2{\pm}26.6$ mSv) was higher than that of patients whose ISS<16($33.5{\pm}23.1$ mSv) (p<0.001). The CED in patients who were treated with surgery or intervention($69.0{\pm}45.2$ mSv) was higher than that of patients who were treated conservatively($33.6{\pm}22.4$ mSv) (p<0.001). The LARs for cancer incidence and mortality were $328.5{\pm}308.6$ and $189.0{\pm}159.3$ per 100,000 people, respectively. Conclusion: The CED and the LAR for trauma CP-activated patients in the ED were significant, so efforts should be made to decrease the effective dose received by severely injured patients.