• 제목/요약/키워드: Radiation correction method

검색결과 120건 처리시간 0.02초

복사 간섭 보정을 통한 초고온 가스 온도 측정 방법 (Temperature Measurement Method with Radiation Correction for Very High Temperature Gas)

  • 김찬수;홍성덕;서동운;김용완;이원재
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2059-2063
    • /
    • 2008
  • When a thermocouple is placed in a high temperature gas-flow stream, the measured temperature could be biased from the true gas temperature due to a large radiation heat loss from a thermocouple surface to its surroundings. In this study, two thermocouples of unequal diameters with 1/8 inch and 1/16 inch are used to correct the radiation effect. The method is called the reduced radiation error (RRE). The preliminary test results show that the radiation and the sheath conduction cannot be negligible for the gas temperature measurement. To minimize the sheath conduction effect, all the thermocouples will have a grounded junction and 1/8 inch thermocouple will be replaced with 1 mm thermocouples. In addition, the computational fluid dynamics code analysis shows that there is a negligible temperature difference between the positions where the thermocouples were installed.

  • PDF

Pulse pileup correction method for gamma-ray spectroscopy in high radiation fields

  • Lee, Minju;Lee, Daehee;Ko, Eunbie;Park, Kyeongjin;Kim, Junhyuk;Ko, Kilyoung;Sharma, Manish;Cho, Gyuseong
    • Nuclear Engineering and Technology
    • /
    • 제52권5호
    • /
    • pp.1029-1035
    • /
    • 2020
  • The detector suffers from pulse pileup by overlapping of the signals when it was used in high radiation fields. The pulse pileup deteriorates the energy spectrum and causes count losses due to random co-incidences, which might not resolve within the resolving time of the detection system. In this study, it is aimed to propose a new pulse pileup correction method. The proposed method is to correct the start point of the pileup pulse. The parameters are obtained from the fitted exponential curve using the peak point of the previous pulse and the start point of the pileup pulse. The amplitude at the corrected start point of the pileup pulse can be estimated by the peak time of the pileup pulse. The system is composed of a NaI (Tl) scintillation crystal, a photomultiplier tube, and an oscilloscope. A 61 μCi 137Cs check-source was placed at a distance of 3 cm, 5 cm, and 10 cm, respectively. The gamma energy spectra for the radioisotope of 137Cs were obtained to verify the proposed method. As a result, the correction of the pulse pileup through the proposed method shows a remarkable improvement of FWHM at 662 keV by 29, 39, and 7%, respectively.

특수일사계를 이용한 맑은 날 일사량의 온도 보정 (Temperature Correction of Solar Radiation on Clear Sky Using by Modified Pyranometer)

  • 조일성;정명재;이규태;지준범;김부요
    • 한국태양에너지학회 논문집
    • /
    • 제35권1호
    • /
    • pp.9-19
    • /
    • 2015
  • Pyranometer have many uncertainty factors (sensitivity function, thermal offset, other spectral effect, geometric, environment, and equipment etc.) than pyrheliometer. The solution for most of the uncertainty factors have been researched, but the problem for thermal offset is being continued research so far. Under the clear sky, due to the thermal offset of pyranometer, the diffuse and global radiation have been negative value for the nighttime and lower value for the daytime, respectively. In order to understand the uncertainty of the thermal offset effect, solar radiation are observed and analyzed using Ji and Tsay method and data from modified pyranometer. As a result of performing temperature correction using the modified pyranometer, the slope (dome factor; k) and intercept ($r_0$) from a linear regression method are 0.064 and $3.457g{\cdot}m^{-2}{\cdot}k^{-1}$, respectively. And the solar radiation is decreased significantly due to the effect of thermal offset during nighttime. The solar radiation from modified pyranometer increased approximately 8% higher than its observed by general pyranometer during daytime. By the way, these results did not generalize because its result is for only single case in clear sky. Accordingly, it is to required for accurate results obtained by the various cases (clear, cloudy and rainy) with longterm observations.

조영제 사용 전${\cdot}$후 불균질 조직 보정 알고리즘에 따른 선량변화에 대한 연구

  • 김주호;조정희;이석;전병철;박재일
    • 대한방사선치료학회지
    • /
    • 제13권1호
    • /
    • pp.38-46
    • /
    • 2001
  • Purpose : The aim of this study is to investigate the effect of tissue inhomogeneities when appling to contrast medium among Homogeneous, Batho and ETAR dose calculation method in RTP system. Method and Material : We made customized heterogeneous phantom it filled with water or contrast medium slab. Phantom scan data have taken PQ 5000 (CT scanner, Marconi, USA) and then dose was calculated in 3D RTP (AcQ-Plan, Marconi, USA) depends on dose calculation algorithm (Homogeneous, Batho, ETAR). The dose comparisons were described in terms of 2D isodose distribution, percent depth dose data, effective path length and monitor unit. Also dose distributions were calculated with homogeneous and inhomogeneous correction algorithm, Batho and ETAR, in each patients with different clinical sites. Results : Result indicated that Batho and ETAR method gave rise to percent depth dose deviation $1.5{\sim}2.7\%,\;2.3{\sim}3.5\%$ (6MV, field size $10{\times}10cm^2$) in each status with and without contrast medium. Also show that effective path lengths were more increase in contrast status (23.14 cm) than Non-contrast (22.07 cm) about $4.9\%$ or 10.7 mm (In case Hounsfield Unit 270) and these results were similary showned in each patient with different clinical site that was lung. prostate, liver and brain region. Concliusion : In conclusion we shown that the use of inhomogeneity correction algorithm for dose calculation in status of injected contrast medium can not represent exact dose at GTV region. These results mean that patients will be more irradiated photon beam during radiation therapy.

  • PDF

High-Dose-Rate Electron-Beam Dosimetry Using an Advanced Markus Chamber with Improved Ion-Recombination Corrections

  • Jeong, Dong Hyeok;Lee, Manwoo;Lim, Heuijin;Kang, Sang Koo;Jang, Kyoung Won
    • 한국의학물리학회지:의학물리
    • /
    • 제31권4호
    • /
    • pp.145-152
    • /
    • 2020
  • Purpose: In ionization-chamber dosimetry for high-dose-rate electron beams-above 20 mGy/pulse-the ion-recombination correction methods recommended by the International Atomic Energy Agency (IAEA) and the American Association of Physicists in Medicine (AAPM) are not appropriate, because they overestimate the correction factor. In this study, we suggest a practical ion-recombination correction method, based on Boag's improved model, and apply it to reference dosimetry for electron beams of about 100 mGy/pulse generated from an electron linear accelerator (LINAC). Methods: This study employed a theoretical model of the ion-collection efficiency developed by Boag and physical parameters used by Laitano et al. We recalculated the ion-recombination correction factors using two-voltage analysis and obtained an empirical fitting formula to represent the results. Next, we compared the calculated correction factors with published results for the same calculation conditions. Additionally, we performed dosimetry for electron beams from a 6 MeV electron LINAC using an Advanced Markus® ionization chamber to determine the reference dose in water at the source-to-surface distance (SSD)=100 cm, using the correction factors obtained in this study. Results: The values of the correction factors obtained in this work are in good agreement with the published data. The measured dose-per-pulse for electron beams at the depth of maximum dose for SSD=100 cm was 115 mGy/pulse, with a standard uncertainty of 2.4%. In contrast, the ks values determined using the IAEA and AAPM methods are, respectively, 8.9% and 8.2% higher than our results. Conclusions: The new method based on Boag's improved model provides a practical method of determining the ion-recombination correction factors for high dose-per-pulse radiation beams up to about 120 mGy/pulse. This method can be applied to electron beams with even higher dose-per-pulse, subject to independent verification.

$^{90}Sr$ 방사성 동위원소를 이용한 전리함의 대기 보정계수 측정 (Air Density Correction of Ionization Chamber using $^{90}Sr$ Radioactive Check Device)

  • 박성용;김우철;신동오;지영훈;권수일;이길동;조영갑;노준규
    • Journal of Radiation Protection and Research
    • /
    • 제23권4호
    • /
    • pp.267-271
    • /
    • 1998
  • 전리함을 사용한 흡수선량 측정시 대기 보정계수의 측정은 필수적인 요소이다. 일반적으로는 기압계 및 온도계를 이용하여 대기 보정계수를 얻고 있는데 본 실험에서는 $^{90}Sr$ 방사성 등위원소를 사용하여 보정계수를 얻고 그 값들을 비교하고자 한다. PTW 사의 Radioactive Check Device, Unidos Elecetrometer 및 0.6 co Ion Chamber를 이용하여 각각의 다른 환경 조건하에서 대기 보정계수를 구하고 온도계와 기압계를 사용하여 구한 대기 보정계수를 비교해 본 결과 그들은 0.2 % 이내로 잘 일치가 되었다. 이론적으로 온도계 및 기압계를 사용할 경우 전체 선량의 불확정도는 ${\pm}$1.2 - 1.6 % 인데 반하여 $^{90}Sr$ 방사성 동위원소를 사용할 경우 전체 선량의 불확정도는 ${\pm}1.02%$로 계산할 수 있다. $^{90}Sr$ 방사성 동위원소를 사용한 방법은 온도계 및 기압계의 정기적인 검교정이 없을 경우 발생할 수 있는 오차를 줄일 수 있으며 보다 정확한 보정계수를 얻을 수 있다.

  • PDF

Performance evaluation of an adjustable gantry PET (AGPET) for small animal PET imaging

  • Song, Hankyeol;Kang, In Soo;Kim, Kyu Bom;Park, Chanwoo;Baek, Min Kyu;Lee, Seongyeon;Chung, Yong Hyun
    • Nuclear Engineering and Technology
    • /
    • 제53권8호
    • /
    • pp.2646-2651
    • /
    • 2021
  • A rectangular-shaped PET system with an adjustable gantry (AGPET) has been developed for imaging small animals. The AGPET system employs a new depth of interaction (DOI) method using a depth dependent reflector patterns and a new digital time pickoff method based on the pulse reconstruction method. To evaluate the performance of the AGPET, timing resolution, intrinsic spatial resolution and point source images were acquired. The timing resolution and intrinsic spatial resolution were measured using two detector modules and Na-22 gamma source. The PET images were acquired in two field of view (FOV) sizes, 30 mm and 90 mm, to demonstrate the characteristic of the AGPET. As a result of in the experiment results, the timing resolution was 0.9 ns using the pulse reconstruction method based on the bi-exponential model. The intrinsic spatial resolution was an average of 1.7 mm and the spatial resolution of PET images after DOI correction was 2.08 mm and 2.25 mm at the centers of 30 mm and 90 mm FOV, respectively. The results show that the proposed AGPET system provided higher sensitivity and resolution for small animal imaging.

A novel reconstruction algorithm based on density clustering for cosmic-ray muon scattering inspection

  • Hou, Linjun;Zhang, Quanhu;Yang, Jianqing;Cai, Xingfu;Yao, Qingxu;Huo, Yonggang;Chen, Qifan
    • Nuclear Engineering and Technology
    • /
    • 제53권7호
    • /
    • pp.2348-2356
    • /
    • 2021
  • As a relatively new radiation imaging method, the cosmic-ray muon scattering imaging technology can be used to prevent nuclear smuggling and is of considerable significance to nuclear safety. Proposed in this paper is a new reconstruction algorithm based on density clustering, aiming to improve inspection quality with better performance. Firstly, this new algorithm is introduced in detail. Then in order to eliminate the inequity of the density threshold caused by the heterogeneity of the muon flux in different positions, a new flux correction method is proposed. Finally, three groups of simulation experiments are carried out with the help of Geant4 toolkit to optimize the algorithm parameters, verify the correction method and test the inspection quality under shielded condition, and compare this algorithm with another common inspection algorithm under different conditions. The results show that this algorithm can effectively identify and locate nuclear material with low misjudging and missing rates even when there is shielding and momentum precision is low, and the threshold correcting method is universally effective for density clustering algorithms.

공명기 분포에 따른 공명기 배열형 패널의 공명주파수 변화 (Resonance frequency shifts of Helmholtz resonator array panel brought by change in resonator arrangements)

  • 김상렬;김양한
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계 학술대회논문집(수송기계편)
    • /
    • pp.97-100
    • /
    • 2005
  • Precise prediction of resonance frequency has been the subject of numerous papers related to Helmholtz resonator design because of its high performance at the frequency. The resonance frequency is dependent upon not only the internal dimensions of resonator but also the external boundary conditions such as the existence of other resonators in Helmholtz resonator array panel. However, the latter effect, which changes the external end correction of resonator, has not been well studied. We propose a formula to calculate the radiation impedance (or external end correction) of Helmhoitz resonator array panel. Any distance between adjacent resonators and any angle of Incidence can be allowed in the method. Numerical examples show how and how much the distance affects the resonance frequency of the panel. It is also found that the maximum absorption of the panel varies with the resonator arrangement.

  • PDF