• Title/Summary/Keyword: Radiation anxiety

Search Result 67, Processing Time 0.023 seconds

Evaluation of Ovary Dose of Childbearing age Woman with Breast cancer in Radiation therapy (가임기 여성의 방사선 치료 시 난소 선량 평가)

  • Park, Sung Jun;Lee, Yeong Cheol;Kim, Seon Myeong;Kim, Young Bum
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.33
    • /
    • pp.145-153
    • /
    • 2021
  • Purpose: The purpose of this study is to evaluate the ovarian dose during radiation therapy for breast cancer in women of childbearing age through an experiment. The ovarian dose is evaluated by comparing and analyzing between the calculated dose in the treatment planning system according to the treatment technique and the measured dose using a thermoluminescence dosimeter (TLD). The clinical usefulness of lead (Pb) apron is investigated through dose analysis according to whether or not it is used. Materials and Methods: Rando humanoid phantom was used for measurement, and wedge filter radiation therapy, 3D conformal radiation therapy, and intensity modulated radiation therapy were used as treatment techniques. A treatment plan was established so that 95% of the prescribed dose could be delivered to the right breast of the Rando humanoid phantom 3D image obtained using the CT simulator. TLD was inserted into the surface and depth of the virtual ovary of the Rando hunmanoid phantom and irradiated with radiation. The measurement location was the center of treatment and the point moved 2 cm to the opposite breast from the center of the Rando hunmanoid phantom, 5cm, 10cm, 12.5cm, 15cm, 17.5cm, 20cm from the boundary of the right breast to the center of treatment and downward, and the surface and depth of the right ovary. Measurements were made at a total of 9 central points. In the dose comparison of treatment planning systems, two wedge filter treatment techniques, three-dimensional conformal radiotherapy, and intensity-modulated radiation therapy were established and compared. Treatments were compared, and dose measurements according to the use of lead apron were compared and analyzed in intensity-modulated radiation therapy. The measured value was calculated by averaging three TLD values for each point and converting using the TLD calibration value, which was calculated as the point dose mean value. In order to compare the treatment plan value with the actual measured value, the absolute dose value was measured and compared at each point (%Diff). Results: At Point A, the center of treatment, a maximum of 201.7cGy was obtained in the treatment planning system, and a maximum of 200.6cGy was obtained in the TLD. In all treatment planning systems, 0cGy was calculated from Point G, which is a point 17.5cm downward from the breast interface. As a result of TLD, a maximum of 2.6cGy was obtained at Point G, and a maximum of 0.9cGy was obtained at Point J, which is the ovarian dose, and the absolute dose was 0.3%~1.3%. The difference in dose according to the use of lead aprons was from a maximum of 2.1cGy to a minimum of 0.1cGy, and the %Diff value was 0.1%~1.1%. Conclusion: In the treatment planning system, the difference in dose according to the three treatment plans did not show a significant difference from 0.85% to 2.45%. In the ovary, the difference between the Rando humanoid phantom's treatment planning system and the actual measured dose was within 0.9%, and the actual measured dose was slightly higher. This did not accurately reflect the effect of scattered radiation in the treatment planning system, and it is thought that the dose of scattered radiation and the dose taken by CBCT with TLD inserted were reflected in the actual measurement. In dosimetry according to the with or without a lead apron, when a lead apron was used, the closer the distance from the treatment range, the more effective the shielding was. Although it is not clinically appropriate for pregnancy or artificial insemination during radiotherapy, the dose irradiated to the ovaries during treatment is not expected to significantly affect the reproductive function of women of childbearing age after radiotherapy. However, since women of childbearing age have constant anxiety, it is thought that psychological stability can be promoted by presenting the data from this study.

Evaluation of Image Quality according to the Use of Attachable X-ray Table Equipped with Heating Device (가열장치를 구비한 부착형 X선 촬영대의 사용에 따른 화질 평가)

  • Song, Jongnam;Kim, Eungkon
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.4
    • /
    • pp.219-225
    • /
    • 2015
  • This study aims to evaluates the image quality of CR and DR that are scanned with the use of the attachable carbon heater X-ray scanner table equipped with heating device by measuring SNR and CNR before and after the attachment of the said table. In the aluminum staircase testing, CR increased SNR and CNR when attached with the table, while DR decreased SNR and CNR. In the human-body model phantom testing, CR increased SNR and CNR only in the low-energy low-dose radiation and the high-energy high-dose radiation, but decreased SNR and CNR under all other conditions. In conclusion, the use of such table can make the patient feel comfortable by removing his or her anxiety, thus helping the testing, but in the actual clinical application thereof, if the thickness and material of the bottom film and the protective film, including the carbon heater, are not considered, it affects the picture quality, thereby requiring continuous research on the use of such table.

Analysis of the Risk Perception of Nuclear Power Plant and Radiation (원자력발전 및 방사선의 사회적 위험에 대한 인식분석)

  • Kim, Jung-Hoon;Kim, Chang-Soo;Lim, Chang-Seon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.8
    • /
    • pp.3570-3577
    • /
    • 2012
  • Researches on the danger of nuclear power generation, the foundation of the development of national industry and one of the energy sources, as perceived by ordinary citizens, are very important to social acceptance of nuclear power generation. Accordingly, this study intends to understand how ordinary citizens perceive the social risk of nuclear power generation and radiation, and their misconceptions, and to propose ways to improve such perceptions. To achieve these goals, this study analyzed the perceptions of 251 ordinary citizens. The analysis showed that ordinary citizens have vague anxiety and suspicion about the safety of nuclear power generation, and little trust in government-affiliated organizations. The younger they were, the more influential they thought corporations and industries were. The result of this study suggests that the misconceptions of ordinary citizens should be corrected by professors and scientists in university research institutions they trust the most, and their intrinsic perceptions should be changed accordingly.

A study on the effect of collimator angle on PAN-Pelvis volumetric modulated arc therapy (VMAT) including junction (접합부를 포함한 PAN-전골반암 VMAT 치료 계획 시 콜리메이터 각도의 영향에 관한 고찰)

  • Kim, Hyeon Yeong;Chang, Nam Jun;Jung, Hae Youn;Jeong, Yun Ju;Won, Hui Su;Seok, Jin Yong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.32
    • /
    • pp.61-71
    • /
    • 2020
  • Purpose: To investigate the effect of collimator angle on plan quality of PAN-Pelvis Multi-isocenter VMAT plan, dose reproducibility at the junction and impact on set-up error at the junction. Material and method: 10 adult patients with whole pelvis cancer including PAN were selected for the study. Using Trubeam STx equipped with HD MLC, we changed the collimator angle to 20°, 30°, and 45° except 10° which was the default collimator angle in the Eclipse(version 13.7) and all other treatment conditions were set to be the same for each patient and four plans were established also. To evaluate these plans, PTV coverage, coverage index(CVI) and homogeneity index (HI) were compared and clinical indicators for each treatment sites in normal tissues were analyzed. To evaluate dose reproducibility at the junction, the absolute dose was measured using a Falmer type ionization chamber and dose changes at the junction were evaluated by moving the position of the isocenter in and out 1~3mm and setting up the virtual volume at the junction. Result: CVI mean value was PTV-45 0.985±0.004, PTV-55 0.998±0.003 at 45° and HI mean value was PTV-45 1.140±0.074, and PTV-55 1.031±0.074 at 45° which were closest to 1. V20Gy of the kidneys decreased by 9.66% and average dose of bladder and V30 decreased by 1.88% and 2.16% at 45° compared to 10° for the critical organs. The dose value at the junction of the plan and the actual measured were within 0.3% and within tolerance. At the junction, due to set-up error the maximum dose increased to 14.56%, 9.88%, 8.03%, and 7.05%, at 10°, 20°, 30°, 45°, and the minimum dose decreased to 13.18%, 10.91%, 8.42%, and 4.53%, at 10°, 20°, 30°, 45° Conclusion: In terms of CVI, HI of PTV and critical organ protection, overall improved values were shown as the collimator angle increased. The impact on set-up error at the junction by collimator angle decreased as the angle increased and it will help improve the anxiety about the set up error. In conclusion, the collimator angle should be recognized as a factor that can affect the quality of the multi-isocenter VMAT plan and the dose at the junction, and be careful in setting the collimator angle in the treatment plan.

The Fukushima Nuclear Accident and Environmental Risk: A Survey of Fukushima Residents

  • Miyawaki, Takeshi;Sasaoka, Shinya
    • Asian Journal for Public Opinion Research
    • /
    • v.5 no.1
    • /
    • pp.1-14
    • /
    • 2017
  • The Fukushima nuclear accident caused by an earthquake and a subsequent tsunami on March 11, 2011 has seriously impacted the environment surrounding the Fukushima Daiichi nuclear power plant. While all the residents near the plant were evacuated from the area deemed uninhabitable after the accident, residents of the neighboring area outside of the evacuation zone still seem to live in fear of invisible radiation. To understand Fukushima residents' thinking about the environmental risks that accompany a nuclear disaster, we utilize a poll of the residents of Fukushima conducted in 2013. Based on the survey data, we reveal factors that seem to strongly affect their knowledge and concerns about nuclear power plants. The results of the multivariate analysis show the importance of the following two factors: (1) confidence in mass media, and (2) trust in institutions in charge of administering the accident, especially the central government, the Nuclear and Industrial Safety Agency, and Tokyo Electric Power Company. We conclude that the more people trust mass media and particular institutions, the more likely it is that they are have an elevated sense of anxiety and fear of the presence of nuclear plants.

The Usefulness of Al Face Block Fabrication for Reducing Exposure Dose of Thyroid Glands in Mammography (유방촬영 시 갑상샘의 피폭선량 경감을 위한 Al Face Block 제작 및 유용성에 관한 연구)

  • Hong, Eun-Ae;Lee, In-Ja
    • Journal of radiological science and technology
    • /
    • v.36 no.1
    • /
    • pp.11-17
    • /
    • 2013
  • Currently, there are many studies being conducted around the world to reduce exposure dose to radiation for patients to receive medical treatments in a safe environment. We developed and fabricated of this shield that the patients are protected from the radiation and are need of safety control during breast imaging. In this study, for breast imaging, GE Senography 2000D were used and set at SID 65cm, 28kVp, and 63mAs. The measuring instrument was Fluke's Victoreen 6000-529. And we performed Face Block on with 30 patients. The chamber on the actual thyroid glands to take CC and MLO and measure the dosage before and after wearing the Face Block. For the results, after wearing the Face Block, exposure was decreased by 53.8%-100% and 65.8% in average in CC View and by 50%-100% and 60.7% in average in MLO View. The development of the Face Block that practically decreased the exposure dose of thyroid glands, crystalline eyes during breast imaging and reduced the patients' anxiety during breast imaging. The Face Block is expected to improve patients' satisfaction and contribute to reducing patients' exposure dose, but more efforts should be made to reduce exposure dose to medical radiation.

Development of Self-Questionnaire for Internal Dose Assessment by Food Ingestion

  • JiEun Lee;Hyo Jin Kim;Yong-Uk Kye;Dong-Yeon Lee;Wol Soon Jo;Chang-Geun Lee;Jung-Ki Kim;Yeong-Rok Kang
    • Journal of Radiation Protection and Research
    • /
    • v.47 no.4
    • /
    • pp.204-213
    • /
    • 2022
  • Background: The accident at the Fukushima Daiichi nuclear power plant increased the level of anxiety related to the radioactive contamination of various foods sourced in Japan. Particularly, after the accident, the detection of artificial radionuclides in locally produced foods raised food safety concerns. In this study, the radioactivity concentrations and annual ingestions of 40K and 137Cs in food products commonly and frequently consumed by the general public were investigated, and the annual effective dose of each was evaluated. Materials and Methods: The 2016-2018 data from the Radiation Safety Management Report released by the Korea Nuclear Safety Technology Center was referenced for the evaluation of the amounts of 40K and 137Cs contained in food. Using the food-ingestion survey mentioned above as a reference, we selected 62 foods to include in our radioactivity concentration and dose assessment. We also developed a questionnaire and evaluated the responses from the subjects who answered the questionnaire. Results and Discussion: The radioactivity concentration of 137Cs was found to be close to or below the level of minimum detectable activity. Additionally, the annual ingestion of 62 foods was 294.77 kg/yr, the effective doses from 40K and 137Cs were 136.4 and 0.163 μSv/yr, respectively. Conclusion: Thus, the findings confirmed that the effective dose from 40K and 137Cs in food tends to be lower than the effective dose limit of 1 mSv/yr suggested by the International Commission on Radiological Protection (ICRP) Publication 60. The questionnaire developed in this study is expected to be useful for estimating the annual effective dose status of Korean adults who consume foods containing 40K and 137Cs.

Rectal Bleeding and Its Management after Irradiation for Cervix Cancer (자궁경부암 환자에서 방사선치료 후에 발생한 직장출혈과 치료)

  • Chun Mison;Kang Seunghee;Kil Hoon-Jong;Oh Young-Taek;Sohn Jeong-Hye;Jung Hye-Young;Ryu Hee Suk;Lee Kwang-Jae
    • Radiation Oncology Journal
    • /
    • v.20 no.4
    • /
    • pp.343-352
    • /
    • 2002
  • Purpose : Radiotherapy is the main treatment modality for uterine cervix cancer. Since the rectum is in the radiation target volume, rectal bleeding is a common late side effect. This study evaluates the risk factors of radiation induced rectal bleeding and discusses its optimal management. Materials and Methods : total of 213 patients who completed external beam radiation therapy (EBRT) and intracavitary radiation (ICR) between September 1994 and December 1999 were included in this study. No patient had undergone concurrent chemo-radiotherapy. Ninety patients received radiotherapy according to a modified hyperfractionated schedule. A midline block was placed at a pelvic dose of between 30.6 Gy to 39.6 Gy. The total parametrial dose from the EBRT was 51 to 59 Gy depending on the extent of their disease. The Point A dose from the HDR brachytherapy was 28 Gy to 30 Gy $(4\;Gy\times7,\;or\;5\;Gy\times6)$. The rectal point dose was calculated either by the ICRU 38 guideline, or by anterior rectal wall point seen on radiographs, with barium contrast. Rectal bleeding was scored by the LENT/SOMA criteria. For the management of rectal bleeding, we opted for observation, sucralfate enema or coagulation based on the frequency or amount of bleeding. The median follow-up period was 39 months $(12\~86\;months)$. Results : The incidence of rectal bleeding was $12.7\%$ (27/213); graded as 1 in 9 patients, grade 2 in 16 and grade 3 in 2. The overall moderate and severe rectal complication rate was $8.5\%$. Most complications $(92.6\%)$ developed within 2 years following completion of radiotherapy (median 16 months). No patient progressed to rectal fistula or obstruction during the follow-up period. In the univariate analysis, three factors correlated with a high incidence of bleeding an icruCRBED greater than 100 Gy $(19.7\%\;vs.\;4.2\%)$, an EBRT dose to the parametrium over 55 Gy $(22.1\%\;vs.\;5.1\%)$ and higher stages of III and IV $(31.8\%\;vs.\;10.5\%)$. In the multivariate analysis, the icruCRBED was the only significant factor (p>0.0432). The total parametrial dose from the EBRT had borderline significance (p=0.0546). Grade 1 bleeding was controlled without further management (3 patients), or with sucralfate enema 1 to 2 months after treatment. For grade 2 bleeding, sucralfate enema for 1 to 2 months reduced the frequency or amount of bleeding but for residual bleeding, additional coagulation was peformed, where immediate cessation of bleeding was achieved (symptom duration of 3 to 10 months). Grade 3 bleeding lasted for 1 year even with multiple transfusions and coagulations. Conclusion : Moderate and several rectal bleeding occurred in $8.5\%$ of patients, which is comparable with other reports. The most significant risk factor for rectal bleeding was the accumulated dose to the rectum (icruCRBED), which corrected with consideration to biological equivalence. Prompt management of rectal bleeding, with a combination of sucralfate enema and coagulation, reduced the duration of the symptom, and minimized the anxiety/discomfort of patients.

Usefulness Evaluation of HRCT using Reconstruction in Chest CT (흉부CT 검사 시 HRCT 영상 재구성의 유용성)

  • Park, Sung-Min;Kim, Keung-Sik;Kang, Seong-Min;Yoo, Beong-Gyu;Lee, Ki-Bae
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.17 no.1
    • /
    • pp.13-18
    • /
    • 2015
  • Purpose : Skip the repetitive HRCT axial scan in order to reduce the exposure of patients during chest HRCT scan, Helical Scan Data into a reconstructed image, and exposure of the patient change and visually evaluate the usefulness of the HRCT images. Materials and method : Patients were enrolled in the survey are 50 people who underwent chest CT scans of patients who presented to the hospital from January 2015 to March 2015. 50 people surveyed 22 people men and 28 people women people showed an average distribution of 30 to 80 years age was 48 years. 50 patients to Somatom Sensation 64 ch (Siemens) model with 120 kVp tube voltage to a reference mAs tube current to mAs (Care dose, Siemens) as a whole, including the lungs and the chest CT scan was performed. Scan upon each patient CARE dose 4D (Automatic exposure control, Siemens Medical Solution Erlangen, Germany) was to maintain the proper radiation dose scan every cross-section through a device that automatically adjusts the tube current of. CT scan is the rotation time of the Tube slice collimation, slice width 0.6 mm, pitch factor was made under the terms of 1.4. CT scan obtained after the raw data (raw data) to the upper surface of the axial images and coronal images for each slice thickness 1 mm, 5 mm intervals in the high spatial frequency calculation method (hight spatial resolution algorithm, B60 sharp) was the use of the lung window center -500 HU, windows were reconstructed into images in the interval -1000 HU to see. Result : 1. Measure the total value of DLP 50 patients who proceed to chest CT group A (Helical Scan after scan performed with HRCT) and group B (Helical Scan after the HR image reconstruction to the original data) compared with the group divided, analysis As a result of the age, but show little difference for each age group it had a decreased average dose of about 9%. 2. A Radiation read the results of the two Radiologist and a doctor upper lobe and middle lobe of the lung takes effect the visual evaluation is not a big difference between the two images both, depending on the age of the patient, especially if the blood vessels of the lower lobe (A: 3.4, B: 4.6) and bronchi(A: 3.8, B4.7) image shake caused by breathing in anxiety (blurring lead) to the original data (raw data) showed that the reconstructed image is been more useful in diagnostic terms. Conclusion : Scan was confirmed a continuous, rapid motion video to get Helical scan is much lower lobe lung reduction in visual blurring, Helical scan data to not repeat the examination by obtaining HRCT images reorganization reduced the exposure of the patient.

  • PDF

New Measurement of Whitening Effects by Using Confocal Scanning Laser Microscope (CSLM) (Confocal Scanning Laser Microscope (CSLM)을 이용한 신규 미백 효과 측정 연구)

  • Kim, Myong Ki;Cho, Seok-Cheol;Nam, Gaewon
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.41 no.3
    • /
    • pp.279-285
    • /
    • 2015
  • Hyperpigmentation on face is a highly anxiety-producing symptom, especially for women from the aspect of beauty. Pigmentation of the skin is related to the amount of melanin that provides protection against UV radiation. In vivo reflectance confocal microscopy is a non-invasive imaging tool allowing visualization of the skin without tissue alteration, by placing a microscopy directly on the living skin. The aim of this study was to develop the new evaluation method of whitening effects using in vivo reflectance confocal microscopy and to validate other instruments for measuring skin colors, and UV-induced hyperpigmentation was elicited on the inside skin of the forearm. It suggested that the new method for whitening effects using the confocal microscopy was useful to evaluate the de-pigmentation products and to easy for understanding to customers.