• Title/Summary/Keyword: Radiation Usage

Search Result 106, Processing Time 0.022 seconds

Measurements of relative depth dose rates for a brachytherapy Ir-192 sourceusing an organic scintillator fiber-optic radiation sensor (유기 섬광체-광섬유 방사선 센서를 이용한 근접 방사선원 Ir-192의 상대 깊이 선량율 측정)

  • Shin, Sang-Hun;Jang, Kyoung-Won;Cho, Dong-Hyun;Yoo, Wook-Jae;Seo, Jeong-Ki;Lee, Bong-Soo;Moon, Joo-Hyun;Kim, Sin;Park, Byung-Gi
    • Journal of Sensor Science and Technology
    • /
    • v.17 no.6
    • /
    • pp.462-469
    • /
    • 2008
  • In this study, we have fabricated a fiber-optic radiation sensor using an organic scintillator and plastic optical fiber for brachytherapy dosimetry. Also, we have measured relative depth dose rates of Ir-192 source using a fiber-optic sensor and compared them with the results obtained using a conventional EBT film. Cerenkov lights which can be a noise in measuring scintillating light with a fiber-optic sensor are measured and eliminated by using of a background optical fiber. It is expected that a fiber-optic radiation sensor can be used in brachytherapy dosimetry due to its advantages such as a low cost, simple usage and a small volume.

Fabrication of Miniature Radiation Sensor Using Plastic Optical Fiber for Medical Usage (플라스틱 광섬유를 이용한 초소형 의료용 방사선 센서 제작)

  • Hwang, Young-Muk;Cho, Dong-Hyun;Cho, Hyo-Sung;Kim, Sin;Lee, Bong-Soo
    • Journal of radiological science and technology
    • /
    • v.28 no.1
    • /
    • pp.9-12
    • /
    • 2005
  • In this study, film type radiation sensor tips are fabricated for remote sensing of X or g-ray with inorganic scintillators and plastic optical fiber. The visible range of light from the inorganic scintillator that is generated by X and g-ray is guided by the plastic optical fiber and is measured by optical detector and power-meter. It is expected that the fiber-optic radiation sensor which is possible to be developed based on this study is used for remote, fast and exact sensing of X or g-ray because of its characteristics such as very small size, light weight and no interference to electromagnetic fields.

  • PDF

Analysis of the Latest Trends of Radioisotope Using in RI-Biomics Fields (RI-Biomics분야 RI의 최신 동향 분석)

  • Jang, Sol-Ah;Yeom, Yu-Sun;Park, Tai-Jin;Hwang, Young Muk;Youn, Dol-Mi
    • Journal of Radiation Industry
    • /
    • v.7 no.2_3
    • /
    • pp.221-224
    • /
    • 2013
  • RI-Biomics is a new compound word of radiation technology and Biomics related to the study of life. RI-Biomics is high radiation fusion technology by combining evaluation of pharmacokinetics in vivo (RI-ADME) of new drugs and medical materials using radioisotope and molecular imaging technology using nuclear medicine equipments. RI-Biomics fields are emerging with the increasing usage of radioisotopes (RI). In this paper, we investigated the latest trends of radioisotope using in RI-Biomics fields. The representative radioisotopes are $^{14}C$, $^3H$ and $^{32}P$ for the optimization and the selection of candidates in the development process of new drugs among the RI-Biomics fields. As shown in the status of accumulated income of radioisotopes, using amounts of radioisotopes are showing a tendency to increase every year. $^{14}C$ is 61.6% increase of accumulated income growth rate and $^3H$ increased by 58.8% and $^{32}P$ increased by 33.9% in 2012 compared to 2007. These isotopes are used in a variety of fields as using of $^{14}C$ for microdosing test, development of [$^3H$]cholesterol absorption inhibitors, study of [$^{131}I$]pyronaridine tetraphosphate for malaria therapy. These are going on in vivo test sucessfully. So, clinical research step is expected to begin soon. Therefore, usages of radioisotopes are necessary and need for the evaluation of pharmacokinetics, optimization and the selection of new drug candidates in the development process of new drugs among the RI-Biomics fields. So, using of radioisotopes is predict to increase continuously except for primarily used $^{14}C$, $^3H$.

Development of RMRD and Moving Phantom for Radiotherapy in Moving Tumors

  • Lee, S.;Seong, Jin-Sil;Chu, Sung-Sil;Yoon, Won-Sup;Yang, Dae-Sik;Choi, Myung-Sun;Kim, Chul-Yong
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2003.09a
    • /
    • pp.63-63
    • /
    • 2003
  • Purpose: Planning target volume (PTV) for tumors in abdomen or thorax includes enough margin for breathing-related movement of tumor volumes during treatment. We developed a simple and handy method, which can reduce PTV margins in patients with moving tumors, respiratory motion reduction device system (RMRDs). Materials and Methods: The patients clinical database was structured for moving tumor patients and patient setup error measurement and immobilization device effects were investigated. The system is composed of the respiratory motion reduction device utilized in prone position and abdominal presser (strip device) utilized in the supine position, moving phantom and the analysis program, which enables the analysis on patients setup reproducibility. It was tested for analyzing the diaphragm movement and CT volume differences from patients with RMRDs, the magnitude of PTV margin was determined and dose volume histogram (DVH) was computed using a treatment planning software. Dose to normal tissue between patients with RMRDs and without RMRDs was analyzed by comparing the fraction of the normal liver receiving to 50% of the isocenter dose(TD50). Results: In case of utilizing RMRDs, which was personally developed in our hospital, the value was reduced to $5pm1.4 mm$, and in case of which the belt immobilization device was utilized, the value was reduced to 3$pm$0.9 mm. Also in case of which the strip device was utilized, the value was proven to reduce to $4pm.3 mm$0. As a result of analyzing the TD50 is irradiated in DVH according to the radiation treatment planning, the usage of the respiratory motion reduction device can create the reduce of 30% to the maximum. Also by obtaining the digital image, the function of comparison between the standard image, automated external contour subtraction, and etc were utilized to develop patients setup reproducibility analysis program that can evaluate the change in the patients setup. Conclusion: Internal organ motion due to breathing can be reduced using RMRDs, which is simple and easy to use in clinical setting. It can reduce the organ motion-related PTV margin, thereby decrease volume of the irradiated normal tissue.

  • PDF

Terms Standardization between the Rules of Diagnosis Radiation Equipment Safety Management and Atomic Energy Law : Problems and Suggestions (진단용 방사선발생장치의 안전관리에 관한 규칙과 원자력법의 용어통일 개선 방향)

  • Kim, Hwa-Gon;Kang, Se-Sik;Kim, Chang-Soo;Park, Cheol-Seo
    • Journal of radiological science and technology
    • /
    • v.29 no.1
    • /
    • pp.39-46
    • /
    • 2006
  • The rules and terms are described different meaning, in this results the research is accomplished for preventing practical workers from confusion. Atomic law are kept up modification and development in our situation by the ICRP's recommendation, on the other hand, the rules of diagnosis radiation equipment safety managements are modified partial, then resulted in confusion. The study was comparison between the rules of diagnosis radiation equipment safety management and atomic energy law, and the modification items obtained were as follows. 1. With each other different the terms and units are used. With the exception of special terms for affairs usage, it is needless to say that common term uniformity is standardized. The standardization of rules and guidance have not need to confusion radiological practical workers. 2. The following is omitted. 1) The radiation protection against tile patient and the hospital visitor. 2) Radiation dose limit of the woman patient who is in the process of becoming pregnant. 3) Radiation dose limit of the person who is not regarded as madical madical exposure. 4) The control of the exposure of pregnant of women at work.

  • PDF

CFD STUDY ON THE COMBUSTION CHAMBER OF A 1 kW CLASS STIRLING ENGINE (1 kW급 LNG 스털링 엔진 연소실 수치해석)

  • Ahn, J.;Lee, Y.S.;Kim, H.J.
    • Journal of computational fluids engineering
    • /
    • v.16 no.3
    • /
    • pp.88-94
    • /
    • 2011
  • The availability of the thermal energy has been deeply recognized recently to encourage the cascade usage of thermal energy from combustion. Within the framework, a 1 kW class Stirling engine based cogeneration system has been proposed for a unit of a distributed energy system. The capacity has been designed to be adequate for the domestic usage, which requires high compactness as well as low emission and noise. To develop a highly efficient system with satisfying these requirements, a premixed slot type short flame burner has been proposed and a series of numerical simulation has been performed to establish a design tool for the combustion chamber. The thermal radiation model has been found to highly affect the computational results and a proper resolution to analyze the heat transfer characteristics of the high temperature heat exchanger. Finally, the combustion characteristics of the premixed flame with the metal fiber type burner has been studied.

Research on the Actual Condition of the radiation Safety Management(RSM) for the Educated Training of the Dental Diagnostics X-ray Generators (교육용 치과 엑스선 발생장치에 대한 방사선 안전 관리 실태 조사)

  • Lee, Mihyeon;Yu, Yunsik;Lee, Jaeseung;Im, Inchul
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.7
    • /
    • pp.467-477
    • /
    • 2014
  • The purpose of this study is to offer data base for establishment of dental training x-ray generator based safety usage through surveying real radiation safety management state of radiation worker's in plan of operations that have dental training x-ray generators and use it. For it, comprehensive references were surveyed referring reports of current state of regulation technique development and domestic radiation safety evaluation and nuclear related legislation regarding radiation safety management of dental training x-ray generators. On the basis of it, questionnaires were filled in about respondent's general characteristic radiation safety manager's status current state of radiation safety management and the level of knowledge & consciousness. For the study, the survey was conducted to 224 people of radiation safety managers and university graduates training assistants and full-time professors who can treat dental training x-ray generators in education center. through this survey 95 questionnaires were used as analysis materials except the insufficient and omitted responses. As a method of analysis, the frequency and percentage were figured out with the general characteristics and safety manager's status. Chi-square test for frequency and correlation per question analysis and Pearson correlation analysis for crosslevel correlation were done with current state of radiation safety management and knowledge & consciousness level. As a result, running dental training x-ray generators was dealt with by 20's to 40's who have high education level over post undergraduate degree and major in dental hygienic. In addition, female have higher consciousness level for radiation safety management than male. It shows significal linear relation statistically(${\chi}^2$ >5, 0.1${\chi}^2$ >5, 0.3${\chi}^2$ >5, 0.3

Improving the Usage of the Korea Meteorological Administration's Digital Forecasts in Agriculture: IV. Estimation of Daily Sunshine Duration and Solar Radiation Based on 'Sky Condition' Product (기상청 동네예보의 영농활용도 증진을 위한 방안: IV. '하늘상태'를 이용한 일조시간 및 일 적산 일사량 상세화)

  • Kim, Soo-ock;Yun, Jin I.
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.17 no.4
    • /
    • pp.281-289
    • /
    • 2015
  • Information on sunshine duration and solar radiation are indispensable to the understanding of crop growth and development. Yet, relevant variables are not available in the Korea Meteorological Administration's (KMA) digital forecast. We proposed the methods of estimating sunshine duration and solar radiation based on the 'sky condition' of digital forecast products and validated using the observed data. The sky condition values (1 for clear, 2 for partly cloudy, 3 for cloudy, and 4 for overcast) were collected from 22 weather stations at 3-hourly intervals from August 2013 to July 2015. According to the observed relationship, these data were converted to the corresponding amount of clouds on the 0 to 10 scale (0 for clear, 4 for partly cloudy, 7 for cloudy, and 10 for overcast). An equation for the cloud amount-sunshine duration conversion was derived from the 3-year observation data at three weather stations with the highest clear day sunshine ratio (i.e., Daegwallyeong, Bukgangneung, and Busan). Then, the estimated sunshine hour data were used to run the Angstrom-Prescott model which was parameterized with the long-term KMA observations, resulting in daily solar radiation for the three weather stations. Comparison of the estimated sunshine duration and solar radiation with the observed at those three stations showed that the root mean square error ranged from 1.5 to 1.7 hours for sunshine duration and from 2.5 to $3.0MJ\;m^{-2}\;day^{-1}$ for solar radiation, respectively.

A Case Study on the MRI Profitability of a General Hospital (한 종합병원의 MRI 채산성 사례 연구)

  • Kang, Chang-Yeol;Song, Sung-Ho;Lim, Kyeong-Tae
    • The Korean Journal of Health Service Management
    • /
    • v.4 no.1
    • /
    • pp.145-156
    • /
    • 2010
  • The purpose of this study is one of high price medical equipment wished to grasp propriety factor about the MRI introduction, analyzing payability through cost accounting into compensation. It was investigated from January 1 to December 31, 2007 about the MRI of a General Hospital. Expectation availability was 23.2 cases, but actual availability did achievement more than 196.1% with 45.5 items. It is estimated that there are a lot of occurrence cases because great reasons that actual availability increases more than expectation availability is excellent resolving power than a CT, and is device that prefer to reason back that radiation damage is less in person body. The followings show the main results of this study. 1. The MRI was construed in order of cost accounting, wave and personnel expenses 45.4%, administrative expenses 53.0%, and material costs 1.6%. 2. According to CVP (Cost-volume-profit) analysis, BEP (Break Even Point) profit is 173,931,428 won for 11 months, and break even usage number of items are 37.5 cases, and separation usage number of items were confirmed by 1.4 cases. Therefore, was construed that can achieve BEP within 11 months though usage number of items keeps 1.4 items day to create the MRI's hospital operation profit. 3. Estimated limit profitability appears high by 96.7%, exceed fixed charges even if when is non-benefit and when it is benefit consider variable, is judged that the MRI's addition induction helps in hospital management enhancing earning rates.

Effect of the amount of battery charge on tube voltage in different hand-held dental x-ray systems

  • Kim, Eun-Kyung
    • Imaging Science in Dentistry
    • /
    • v.42 no.1
    • /
    • pp.1-4
    • /
    • 2012
  • Purpose : Hand-held dental x-ray system is a self contained x-ray machine designed to perform intraoral radiography with one or two hands. The issue about its usage as general dental radiography is still in dispute. The aim of the present study was to assess the relationship between the amount of battery charge and the tube voltage in different handheld dental x-ray systems. Materials and Methods : Seven hand-held dental x-ray units were used for the study. Tube voltage was measured with Unfors ThinX RAD (Unfors Instruments AB, Billdal, Sweden) for 3 consecutive exposures at the different amount of battery charge of each unit. The average and the deviation percentage of measured kV from indicated kV of each unit were calculated. Results : Tube voltage of only 1 unit was 70 kV (indicated by manufacturer) and those of the others were 60 kV. Tube voltage deviation percentage from the indicated kV at the fully charged battery was from 2.5% to -5.5% and from -0.8% to -10.0% at the lowest charged battery. Conclusion : Tube voltages of all units decreased as the residual amount of the battery charge decreased. It is suggested that the performance test for hand-held x-ray system should be performed for the minimum residual charged battery as well as the full charged one. Persistent battery charging is suggested to maintain the proper tube voltage of the hand-held portable x-ray system.