• 제목/요약/키워드: Radiation Output

검색결과 466건 처리시간 0.027초

고효율 X선 검출기 적용을 위한 PbO 필름 제작 및 특성 연구 (Fabrication and Characterization of Lead Oxide (PbO) Film for High Efficiency X-ray Detector)

  • 조성호;강상식;최치원;권철;남상희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 하계학술대회 논문집 Vol.8
    • /
    • pp.329-329
    • /
    • 2007
  • Photoconductive poly crystalline lead oxide coated on amorphous thin film transistor (TFT) arrays is the best candidate for direct digital x-ray detector for medical imaging. Thicker films with lessening density often show lower x-ray induced charge generation and collection becomes less efficient. In this work, we present a new methodology used for the high density deposition of PbO. We investigate the structural properties of the films using X-ray diffraction and electron microscopy experiments. The film coatings of approximately $200\;{\mu}m$ thickness were deposited on $2"{\times}2"$ conductive-coated glass substrates for measurements of dark current and x-ray sensitivity. The lead oxide (PbO) films of $200\;{\mu}m$ thickness were deposited on glass substrates using a wet coating process in room temperature. The influence of post-deposition annealing on the characteristics of the lead oxide films was investigated in detail. X-ray diffraction and scanning electron microscopy, and atomic force microscopy have been employed to obtain information on the morphology and crystallization of the films. Also we measured dark current, x-ray sensitivity and linearity for investigation of the electrical characteristics of films. It was found that the annealing conditions strongly affect the electrical properties of the films. The x-ray induced output charges of films annealed in oxygen gas increases dramatically with increasing annealing temperatures up to $500^{\circ}C$ but then drops for higher temperature anneals. Consequently, the more we increase the annealing temperatures, the better density and film quality of the lead oxide. Analysis of this data suggests that incorporation and decomposition reactions of oxygen can be controlled to change the detection properties of the lead oxide film significantly. Post-deposition thermal annealing is also used for densely film. The PbO films that are grown by new methodology exhibit good morphology of high density structure and provide less than $10\;pA/mm^2$ dark currents as they show saturation in gain (at approximate fields of $4\;V/{\mu}m$). The ability to operate at low voltage gives adequate dark currents for most applications and allows voltage electronics designs.

  • PDF

광역학적 암치료를 위한 635nm 다이오드 레이저 시스템 개발 (The Development of 63nm Diode Laser System for Photodynamic Therapy of Cancer)

  • 임현수
    • 대한의용생체공학회:의공학회지
    • /
    • 제24권4호
    • /
    • pp.319-328
    • /
    • 2003
  • 본 논문은 광역학적 암치료를 위한 광원장치의 개발로서 반도체 다이오드 레이저를 이용한 의료용 레이저 시스템의 개발이 목적이다. 광역학적 암 치료에서 이상적인 광원장치는 초점크기를 조절할 수 있으면서 발산하지 않는 균일한 빛과 특정 파장대의 안정성을 갖는 것이다. 본 연구에서는 이러한 점을 고려하여 635nm 파장대의 다이오드 공진기를 이용하였으며, 개발된 레이저 시스템은 제어장치를 사용하여 정교하고 안정적인 출력을 가지도록 하였으며, 시스템은 사용자의 편리성을 고려하여 소형화하였다. 다이오드 레이저시스템의 펄스 형태의 발진모드에서는 초기의 돌입전류에 의해 공진기를 파손시킬 수 있으므로 본 연구에서는 이러한 현상을 회로적으로 보완하여 msec 단위로 on/off 할 경우에도 공진기에 전혀 손상을 입히지 않도록 설계를 하였다. 임상의가 편리하게 방사시간을 설정하고, 연속출력. 펄스. 버스트 펄스, 슈퍼펄스를 방사할 수 있도록 고안하여. 다양한 암조직의 상태에 따라 치료할 수 있도록 구현하였다. 실험결과 레이저의 출력은 입력전류와 시간에 따라 10mW에서 300mW 까지 선형적으로 증가함을 보였다. 개발된 광역학적 레이저 시스템은 고속제어가 가능하고 정 전류 제어와 효과적인 냉각 제어를 통해 안정적으로 정확하게 출력할 수 있었다.

센서-회로 분리형 엑스선 DR 검출기를 위한 대면적 CMOS 영상센서 모사 연구 (Simulation Study of a Large Area CMOS Image Sensor for X-ray DR Detector with Separate ROICs)

  • 김명수;김형택;강동욱;유현준;조민식;이대희;배준형;김종열;김현덕;조규성
    • 방사선산업학회지
    • /
    • 제6권1호
    • /
    • pp.31-40
    • /
    • 2012
  • There are two methods to fabricate the readout electronic to a large-area CMOS image sensor (LACIS). One is to design and manufacture the sensor part and signal processing electronics in a single chip and the other is to integrate both parts with bump bonding or wire bonding after manufacturing both parts separately. The latter method has an advantage of the high yield because the optimized and specialized fabrication process can be chosen in designing and manufacturing each part. In this paper, LACIS chip, that is optimized design for the latter method of fabrication, is presented. The LACIS chip consists of a 3-TR pixel photodiode array, row driver (or called as a gate driver) circuit, and bonding pads to the external readout ICs. Among 4 types of the photodiode structure available in a standard CMOS process, $N_{photo}/P_{epi}$ type photodiode showed the highest quantum efficiency in the simulation study, though it requires one additional mask to control the doping concentration of $N_{photo}$ layer. The optimized channel widths and lengths of 3 pixel transistors are also determined by simulation. The select transistor is not significantly affected by channel length and width. But source follower transistor is strongly influenced by length and width. In row driver, to reduce signal time delay by high capacitance at output node, three stage inverter drivers are used. And channel width of the inverter driver increases gradually in each step. The sensor has very long metal wire that is about 170 mm. The repeater consisted of inverters is applied proper amount of pixel rows. It can help to reduce the long metal-line delay.

CMOS 기반 X선 영상의 해상력 향상을 위한 Gd2O2S:Tb 미세형광체 필름 제작 및 영상 질 평가 (Fabrication of Gd2O2S:Tb fine scintillator film and evaluation of image quality for resolution improvement of X-ray imaging based on CMOS)

  • 강상식;최영준;정봉재;노시철;조창훈;윤인찬;박지군
    • 한국방사선학회논문지
    • /
    • 제5권5호
    • /
    • pp.283-287
    • /
    • 2011
  • 본 연구는 고해상도 디지털 X선 영상 검출기 적용을 위해 미세 $Gd_2O_2S$:Tb 형광체 분말을 저온 액상법을 이용하여 합성하였다. 제조된 형광체 분말을 이용하여 입자침전법을 이용하여 형광체 필름을 제작하여 발광특성을 조사하였다. 측정결과, Tb 첨가농도에 따른 상대적인 발광량 측정결과 5 wt%의 첨가농도에서 가장 높은 발광효율을 보였으며, 첨가농도가 증가할수록 소광현상에 의한 발광강도가 급격히 감소하는 경향을 보였다. 또한 270 ${\mu}m$ 두께의 $Gd_2O_2S$:Tb에서 2945 pC/$cm^2$/mR의 발광 강도를 가졌으며, 발광 강도가 거의 포화되는 것을 관찰할 수 있었다. 끝으로 제조된 형광체의 영상획득 성능을 평가하기 위해 상용화된 CMOS 센서를 이용하여 X선 영상을 획득하여 MTF, NPS를 측정하여 DQE 평가를 수행하였다. 측정결과, DQE(0)의 값은 37%로 다소 낮은 값을 보였다. 향후 필름 제조 공정상의 문제점을 해결한다면, DQE를 개선할 수 있을 것으며, 고해상도 의료 방사선 영상 시스템 적용에 유용하게 적용 가능할 것으로 판단된다.

협대역 고출력 전자기파에 의한 CMOS IC의 전기적 특성 분석 (An Electrical Properties Analysis of CMOS IC by Narrow-Band High-Power Electromagnetic Wave)

  • 박진욱;허창수;서창수;이성우
    • 한국전기전자재료학회논문지
    • /
    • 제30권9호
    • /
    • pp.535-540
    • /
    • 2017
  • The changes in the electrical characteristics of CMOS ICs due to coupling with a narrow-band electromagnetic wave were analyzed in this study. A magnetron (3 kW, 2.45 GHz) was used as the narrow-band electromagnetic source. The DUT was a CMOS logic IC and the gate output was in the ON state. The malfunction of the ICs was confirmed by monitoring the variation of the gate output voltage. It was observed that malfunction (self-reset) and destruction of the ICs occurred as the electric field increased. To confirm the variation of electrical characteristics of the ICs due to the narrow-band electromagnetic wave, the pin-to-pin resistances (Vcc-GND, Vcc-Input1, Input1-GND) and input capacitance of the ICs were measured. The pin-to-pin resistances and input capacitance of the ICs before exposure to the narrow-band electromagnetic waves were $8.57M{\Omega}$ (Vcc-GND), $14.14M{\Omega}$ (Vcc-Input1), $18.24M{\Omega}$ (Input1-GND), and 5 pF (input capacitance). The ICs exposed to narrow-band electromagnetic waves showed mostly similar values, but some error values were observed, such as $2.5{\Omega}$, $50M{\Omega}$, or 71 pF. This is attributed to the breakdown of the pn junction when latch-up in CMOS occurred. In order to confirm surface damage of the ICs, the epoxy molding compound was removed and then studied with an optical microscope. In general, there was severe deterioration in the PCB trace. It is considered that the current density of the trace increased due to the electromagnetic wave, resulting in the deterioration of the trace. The results of this study can be applied as basic data for the analysis of the effect of narrow-band high-power electromagnetic waves on ICs.

상업용 12인치 급속가열장치의 제어계 설계를 위한 모델인식 (Model Identification for Control System Design of a Commercial 12-inch Rapid Thermal Processor)

  • 윤우현;지상현;나병철;원왕연;이광순
    • Korean Chemical Engineering Research
    • /
    • 제46권3호
    • /
    • pp.486-491
    • /
    • 2008
  • 상업용 12인치 급속가열장치(RTP)의 다변수 고급제어기를 개발하기 위하여 열전대가 부착된 웨이퍼를 대상으로 다변수 모델인식을 수행하였다. 웨이퍼에는 7개의 열전대가 설치되어 있으며 10개의 텅스텐-할로겐 램프 그룹으로 가열을 할 수 있다. 모델인식 실험과정에서 웨이퍼의 휨을 최소화하며 최종적으로 10-입력 7-출력의 균형 잡힌 상태공간 모델을 얻기 위한 모델인식방법을 제안하였다. 또한 넓은 온도영역에서 복사에 의한 비선형성을 가장 효과적으로 상쇄시킬 수 있는 출력변수 정의방법을 제안하였다. 600, 700, $800^{\circ}C$ 부근의 정상상태에서 실험을 수행하여 모델을 추정한 결과 상태의 차수는 80~100, 모델출력은 $y=T(K)^2$으로 결정하는 것이 바람직하며, 이때 one-step-ahead 온도예측 오차의 제곱평균은 0.125~0.135 K 정도로 나타났다.

방사성동위원소 추적자를 이용한 침적형 고정 미생물 반응조 진단 (Diagnosis of Submerged Fixed Bioreactor using Radioisotope Tracer)

  • 정성희;진준하;이면주
    • 대한환경공학회지
    • /
    • 제22권6호
    • /
    • pp.1149-1158
    • /
    • 2000
  • 염색폐수를 생물학적으로 처리하여 방류하는 연속으로 연결되어있는 6개의 단으로 구성된 폐수처리시설에서 폐수 유동을 관찰하고 처리공정에 영향을 줄 수 있는 요인들을 찾기 위해 동위원소를 이용한 추적자 실험을 수행하였다. 추적자로 약 20mCi의 $^{131}I$를 첫 번째 단의 폐수 유입부에 투입하고 각 단에 방사선 검출기를 설치하여 시간에 따른 추적자 농도변화를 측정하였다. 측정된 데이터를 Perfect Mixers in Series Model을 이용한 분석을 통하여 평균체재시간과 시스템에서의 유동 특성 파라미터들을 계산하였다. 시스템의 평균체재시간은 설계치인 22.3시간의 76%인 17시간으로 계산되었다. 시스템을 구성하고 있는 6개의 단 중에서 제1단은 완전혼합기(perfect mixer)로서의 특성을 보이지 않았으나, 나머지 5개의 단은 완전혼합기와 같이 작동하였다. 제1단의 출력은 상호 교환이 일어나는 탱크를 가진 완전혼합기 모델로 모사한 출력과 좋은 일치를 보였다. 이 교환되는 탱크의 크기는 전체의 약 4분의 1인 것으로 분석되었다. 체재시간분포 실험의 결과는 유입 폐수의 방사선 전처리를 위해 설치된 전자선가속기의 가동조건 변경 후 그 영향에 대한 연구를 위한 적정 시료채취시간 산정에 사용되었다.

  • PDF

진단 엑스선 영상에서 환자 위치잡이의 자동화 (Auto-Positioning of Patient in X-ray Diagnostic Imaging)

  • 양원석;손정민;천권수
    • 한국방사선학회논문지
    • /
    • 제12권6호
    • /
    • pp.793-799
    • /
    • 2018
  • 인공지능에 대한 관심이 높아짐에 따라 의료분야에서도 활발하게 인공지능이 연구되고 있다. 현재 국내에서는 엑스선 촬영, 컴퓨터단층촬영(Computer Tomography), 자기공명영상(Magnetic Resonance Imaging) 등의 의료영상장치에 인공지능이 접목되고 있으며 향후 방사선사 없이 환자의 방사선 영상을 획득 할 수 있는 인공지능을 탑재한 의료기기가 발명 될 것으로 예상된다. 본 연구는 엑스선 촬영에 있어서 환자 위치잡이에 대한 자동화에 대해서 초기 연구를 했다. 위치잡이에 대한 평가를 위해 엑스선 장비와 인체 팬텀을 사용했다. 프로그램은 Visual Studio 2010 MFC로 구현했으며 영상은 $1,450{\times}1,814$ 크기로 했다. 픽셀 값을 눈으로 식별 가능한 0 ~ 255 값을 갖는 명암으로 변환하여 모니터에 출력했다. 출력한 영상에 세 픽셀 좌표 값을 통해 각도를 예측하고 각도에 따른 음성안내에 따라 환자가 바른 위치잡이를 하도록 유도하는 절차 알고리즘 프로그램을 개발 했다. 다음 연구에서는 사용자가 좌표의 기준을 인공지능에게 전달하는 것이 아닌 인공지능 스스로 구조물을 파악하여 각도를 계산하는 연구를 진행할 것이다. 향후 위치잡이의 자동화를 통해 촬영부터 위치잡이까지 인공지능이 실시하도록 하는 연구에 도움이 될 것으로 예상된다.

전산화단층영상 기반 뇌출혈 검출을 위한 YOLOv5s 성능 평가 (Performance Evaluation of YOLOv5s for Brain Hemorrhage Detection Using Computed Tomography Images)

  • 김성민;이승완
    • 한국방사선학회논문지
    • /
    • 제16권1호
    • /
    • pp.25-34
    • /
    • 2022
  • 뇌 전산화단층촬영은 비침습성, 3차원 영상 제공, 저방사선량 등의 장점 때문에 뇌출혈과 같은 질병 진단을 위해 시행된다. 하지만 뇌 전산화단층영상 판독을 위한 전문의의 인력 공급 부족 및 막대한 업무량으로 인해 수많은 판독 오류 및 오진이 발생하고 있다. 이와 같은 문제를 해결하기 위해 객체 검출을 위한 다양한 인공지능 기술이 개발되고 있다. 본 연구에서는 뇌 전산화단층영상으로부터 뇌출혈 검출을 위한 딥러닝 기반 YOLOv5s 모델의 적용 가능성을 확인하였다. 또한 YOLOv5s 모델 학습 시 초매개변수를 변화시켜 학습된 모델의 성능을 평가하였다. YOLOv5s 모델은 backbone, neck 및 output 모듈로 구성하였고, 입력 CT 영상 내 뇌출혈로 의심되는 부위를 검출하여 출력할 수 있도록 하였다. YOLOv5s 모델 학습 시 활성화함수, 최적화함수, 손실함수 및 학습 횟수를 변화시켰고, 학습된 모델의 뇌출혈 검출 정확도 및 학습 시간을 측정하였다. 연구결과 학습된 YOLOv5s 모델은 뇌출혈로 의심되는 부위에 대한 경계 박스 및 해당 경계박스에 대한 정확도를 출력할 수 있음을 확인하였다. Mish 활성화함수, stochastic gradient descent 최적화함수 및 completed intersection over union 손실함수 적용 시 YOLOv5s 모델의 뇌출혈 검출 정확도 향상 및 학습 시간이 단축되는 결과를 확인하였다. 또한 YOLOv5s 모델의 뇌출혈 검출 정확도 및 학습 시간은 학습 횟수에 비례하여 증가하는 결과를 확인하였다. 따라서 YOLOv5s 모델은 뇌 전산화단층영상을 이용한 뇌출혈 검출을 위해 활용할 수 있으며, 최적의 초매개변수 적용을 통해 성능을 향상 시킬 수 있다.

연구용 압출기를 활용한 PLA와 텅스텐 혼합물의 차폐 성능 (Shielding Performance of PLA and Tungsten Mixture using Research Extruder)

  • 김도성;김태형;윤명성;김상현
    • 한국방사선학회논문지
    • /
    • 제17권4호
    • /
    • pp.557-564
    • /
    • 2023
  • 본 연구에서는 차폐성능의 우수함이 증명된 납 사용에 있어 나타나는 단점을 보완하고 불필요한 인체 피폭을 제어하기 위하여 3D 프린팅 기술을 이용하였다. 3D 프린터는 3차원 형상 구현이 가능하며, 개인의 아이디어를 즉각적으로 적용할 수 있어 시제품 제작 비용 및 기간을 줄여주면서 기술 보완 유지에 큰 장점이 있다. 다양한 특증의 3D 프린터 중 FDM 방식을 채택하였으며, 출력에 사용되는 필라멘트를 폴리락트산 (Polylactic acid, PLA)와 텅스텐 두 가지 소재를 혼합하여 연구용 압출기를 활용해 제작하였다. 출련된 혼합 필라멘트를 형태학적 차폐체로 구현하였으며, 선량평가를 통해 유효성 검증과 동시에 다양한 물질의 차페체 제작에 기초 정보 제공에 목적을 두었다. PLA와 텅스텐을 혼합하여 연구용 압출기로 제작된 필라멘트는 텅스텐 함유 비율에 따라서 10 %, 20 %, 30 %, 40 %, 50 %로 구분하여 제작하였다. 3D Modeling, STL File 저장, G-code생성, 출력등의 처리과정으로 10 cm × 10 cm × 0.5cm의 크기로 각각 제작하였고, 관전압 60 kVp, 80 kVp, 100 kVp, 120 kVp와 관전류 20 mAs, 40 mAs의 조건으로 선량 및 차폐성능 평가 실험하였다.