• 제목/요약/키워드: Radiation Output

검색결과 466건 처리시간 0.03초

Even Harmonic Mixer를 이용한 2.4GHz ISM band용 Direct Conversion방식의 RF Module 설계 및 제작 (Design and Fabrication of Direct Conversion RF Module using Even Harmonic Mixer for 2-4GHz ISM band)

  • 이주갑;윤영섭;최현철
    • 한국전자파학회:학술대회논문집
    • /
    • 한국전자파학회 2001년도 종합학술발표회 논문집 Vol.11 No.1
    • /
    • pp.222-226
    • /
    • 2001
  • In this paper, 2.4GHz RF Module using Even Harmonic Mixer(EHM) was designed and fabricated for Direct conversion(DC) system. By minimizing performance degradation of DC system with DC offset and LO radiation, the capability of minimization and one chip solution in wireless system was proposed. The designed EHM using anti-parallel diode pair represented 9dB conversion loss and about -60dBm 2LO leakage radiation in RF port, and output reflection and reverse transmission characteristic of low noise amplifier was improved. So superior DC offset suppression characteristic is expected. RF Module which consists of EHM, LNA, RF amplifier, Frequency synthesizer and Duplexer was designed and fabricated.

  • PDF

Cosmic Infrared Background from the First Stars and Relic H II Regions

  • 안경진
    • 천문학회보
    • /
    • 제36권2호
    • /
    • pp.72.2-72.2
    • /
    • 2011
  • We have performed the first self-consistent, large-scale simulation of cosmic reionization by stellar sources, including the Population III stars that emerged and were hosted by minihalos at very high redshifts (z~40). Based on this result, we calculate the redshifted radiation background from these stars and the relic H II regions which can be observed at near-infrared and infrared regime. Formation of the first stars inside minihalos are quenched by radiative feedback at z~15, while the relic H II regions have much longer lifetime due to the slow recombination rate. Therefore, the radiation output from the relic H II regions, dominated by Lyman alpha photons, will be observed both in the near-infrared and infrared regime. The estimated background from the first stars inside minihalos are still sub-dominant compared to that from stars inside larger halos, however, and thus complementary observations are necessary, such as redshifted 21-cm line observation.

  • PDF

고출력 고주파 증폭기의 설계 (Design of High Power RF Amplifier)

  • 남상훈;전명환;김영수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 A
    • /
    • pp.180-182
    • /
    • 1994
  • In an electron storage ring of Pohang Light Source (PLS), electrons lose their energy in every turn by the synchronous radiation. A high power RF amplifier is employed to compensate the electron energy that is lost by the synchronous radiation. The specification of RF amplifier is an continuous output power of 60 kW at 500.082 MHz operating frequency. The power is supplied to RF cavities in the storage ring tunnel. Total number of amplifier system currently required is three. Tile total number will be increased upto five as the operating condition of storage ring is upgraded. The RF amplifier is mainly consisted of a high voltage DC power supply, an intermediate RF power amplifier (IPA), and a klystron tube. In this article, the design of RF amplifier system and characteristics of the klystron tube will be discussed.

  • PDF

고전압트랜스포머의 진공이 방사선출력 노이즈에 미치는 영향 (Electric power characteristic test of diagnostic X-ray high voltage transformer by input power condition)

  • 김영표;천민우;박용필
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 하계학술대회 논문집 Vol.9
    • /
    • pp.499-499
    • /
    • 2008
  • High voltage transformer of Diagnostic X-ray system has been contributed to wiping out disease to get a good quality images from patients. High voltage transformer of diagnostic X-ray system has been usefully used for diagnostic purpose but if high voltage transformer performances are deteriorated, low quality image will be archived. In this case, operator has to exposure to get a more good quality images. In this case, unexpected radiation could be exposed to patient and it is very harmful to the patient. And I would like to design and make equipment to checkable high voltage transformer performance after that I wish to test and study what it is most influences in radiation output quality.

  • PDF

선량평가 및 Display시스템 (A Rapid Dose Assessment and Display System Applicable to PWR Accident)

  • 문광남;육종철
    • Journal of Radiation Protection and Research
    • /
    • 제13권2호
    • /
    • pp.67-77
    • /
    • 1988
  • 원자력발전소의 비상사태 발생시 효과적인 비상대책 수립을 위하여 인근 주민에 대한 신속한 피폭선량 평가 시스템의 개발이 강조되고 있다. 여기서 개발한 시스템은 다양한 원전의 사고에 대해 인근 주민에 대한 방사선 영향의 신속한 평가 모델로서 마이크로 컴퓨터에 기초한 프로그램이며, 문답형의 메뉴방식의 사용자 입력구조를 가지고 있고 수행 결과의 출력은 표 또는 그래픽 형식의 구조를 가지고 있어서 신속한 피폭선량평가 수행뿐만 아니라 신속한 결과 판독이 가능하여 비상대책 활동을 위한 결정에 도움을 준다.

  • PDF

Extension Test of Midday Apparent Evapotranspiration toward Daily Value Using a Complete Remotely-Sensed Input

  • Han, Kyung-Soo;Kim, Young-Seup
    • 대한원격탐사학회지
    • /
    • 제19권5호
    • /
    • pp.341-349
    • /
    • 2003
  • The so-called B-method, a simplified surface energy budget, permits calculation of daily actual evapotranspiration (ET) using remotely sensed data, such as NOAA-AVHRR. Even if the use of satellite data allows estimation of the albedo and surface temperature, this model requires meteorological data measured at ground-level to obtain the other inputs. In addition, a difficulty may be occurred by the difference of temporal scales between the net radiation in daily scale and instantaneous measurement at midday of the surface and air temperatures because the data covered whole day are necessary to obtain accumulated daily net radiation. In order to solve these problems, this study attempted a modification of B-method through an extension of hourly ET value calculated using a complete instantaneous inputs. The estimation of the daily apparent ET from newly proposed system showed a root mean square error of 0.26 mm/day as compared the output obtained from the classical model. It is evident that this may offer more rapid estimation and reduced data volume.

CLINAC 1800 선형가속기의 15 MV X-선의 특성 (Characteristics of 15 MV Photon Beam from a Varian Clinac 1800 Dual Energy Linear Accelerator)

  • 김계준;이종영;박경란
    • Radiation Oncology Journal
    • /
    • 제9권1호
    • /
    • pp.131-141
    • /
    • 1991
  • 국내에서 처음으로 사용되는 CLINAC 1800에서 발생된 15MV X-선의 특성을 구하기 위하여 3 Dimensional water Phantom Dosimetry system)를 이용하여 방사선 치료에 근간이 되는 심부선량 백분율(POD), 최대 조직 비율(TMR), 편평도(beam profile), 대칭도, Wedge인자 등을 측정하였고 선량계산을 위하여 출력 인자들을 구하였다. 1. 선축상 최대치 지점(Dmax)은 SSD 100cm일때 조사면이 $10\times10cm^2$에서 $3.0\pm0.1$ cm이였고 $4\times4cm^2,\;35\times35cm^2$에서 각각 $3.1\pm0.1\;cm,2.2\pm0.1$ cm으로 조사면이 넓어지면서 측정치가 표면에 가까워지는 결과를 보였다. 2. 조직표면 선량(Surface Dose)는 SSD 100cm일때 조사면이 $10\times10cm^2$에서 $15.5\%$이였고 $4\times4cm^2,\;35\times35cm^2$에서 각각 $9.8\%\;,51.2\%$로 조사면이 넓어지면서 표면 선량은 증가하는 결과를 보였다. 3. 심부선량 백분율(PDO)은 SSD 100cm에서 측정하였고 조사면이 $10\times10cm^2$이고 10cm depth에서 $76.8\%$이였고 $80\%,\;50\%$ 선량의 깊이는 각각 $9.1\pm0.1\;cm,19.9\pm0.2\;cm$으로 측정되었다. 4. 최대조직비율(TMR)은 심부선량 백분율(PDD)로부터 계산하였고 측정값과의 차이는 $10\times10cm^2$ 조사면에서 평균 $1\;%$ 이내의 오차를 보였다. 5. 대칭도(symmetry)와 편평도(flatness)는 조사면 $10\times10cm^2$일때 각각 $0.73\%,\;2.72\%$이였다. 6. 출력인자(output factor)는 $10\times10cm^2$ 기준 조사면에서 흡수선량을 1로 하였을때 $4\times4cm^2,\;35\times35cm^2$ 조사면에서는 각각 0.927, 1.087로 측정되었는데 조사면이 증가할수록 흡수량이 증가하는 결과를 보였다. 7. Wedge factor는 $15^{\circ}\;30^{\circ}\;45^{\circ}\;60^{\circ}$를 10cm깊이에서 측정하였는데 0.825, 0.099, 0.560, 0.457로 각각 측정되었고 아크릴 0.4 mm Tray의 투과율은 0.976이였다. 8. 15 MV X-선에 의한 납벽층의 반가층 두께는 13 mm였고 Cerrobend의 반가층은 15.5 mm으로 측정되었다.

  • PDF

UV램프를 이용한 유수처리형 살균장치의 설계방법 (Design Method for Flowing Water Purification with UV Lamp)

  • 정병균;이진종;정병호
    • 전기학회논문지P
    • /
    • 제58권4호
    • /
    • pp.455-460
    • /
    • 2009
  • A number of factors combine to make ultraviolet radiation a superior means of water purification for ground water, rainwater harvesting systems and so on. Ultraviolet radiation is capable of destroying all types of bacteria. Additionally, ultraviolet radiation disinfects rapidly without the use of heat or chemical additives which may undesirably alter the composition of water. In a typical operation, water enters the inlet of a UV lamp and flows through the annular space between the quartz sleeve and the outside chamber wall. The irradiated water leaves through the outlet nozzle. Several design features are combined to determine the dosage delivered. The first is Wavelength output of the lamp, the Second is Length of the lamp - when the lamp is mounted parallel to the direction of water flow, the exposure time is proportional to the length of the lamp, the third is Design water flow rate - exposure time is inversely related to the linear flow rate, the forth is Diameter of the purification chamber - since the water itself absorbs UV energy, the delivered dosage diminishes logarithmically with the distance from the lamp. In this paper, It describe the how to design optimal UV disinfection device for ground water and rainwater. To search the optimal design method, it was performed computer simulation with 3D-CFD discrete ordinates model and manufactured prototype. Using proposed design method manufactured prototype applied to disinfection test and proved satisfied performance.

고정밀 레이저 변위기용 반사 광량 측정 기법 (The Measurement Method of Reflected Intensity of Radiation for High Precision Laser Range Finder)

  • 배영철;조의주;이현재;김성현;김현우
    • 한국항행학회논문지
    • /
    • 제13권1호
    • /
    • pp.34-40
    • /
    • 2009
  • 고정밀 레이저 변위기에서 측정하고자하는 목표물인 표적으로부터 반사되어 돌아오는 반사광의 강도에 따라 애벌런치 포토다이오드(APD: Avalanche Photo Diode) 출력신호의 위상 지연이 발생한다. 이 위상지연에 의한 차이는 측정오차의 주요 원인이 되나 이를 측정하기 위한 적절한 계측기와 측정 방법이 없었다. 본 논문에서는 이들 문제를 해결하기 위하여, APD의 수신회로에 반사광량에 비례하는 출력 DC 전압을 측정하여 실시간으로 반사광의 강도를 측정할 수 있는 광량 측정기법을 제시하고 구현하였다.

  • PDF

CALIBRATION ISSUES OF SPACEBORNE MICROWAVE RADIOMETER DREAM ON STSAT-2

  • Singh, Manoj Kumar;Kim, Sung-Hyun;Chae, Chun-Sik;Lee, Ho-Jin;Park, Jong-Oh;Sim, Eun-Sup;Zhang, De-Hai;Jiang, Jing-Shan;Kim, Yong-Hoon
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2006년도 Proceedings of ISRS 2006 PORSEC Volume I
    • /
    • pp.398-401
    • /
    • 2006
  • Dual channel Radiometer for Earth and Atmospheric Monitoring (DREAM) is the main payload on Science and Technology SATellite-2 (STSAT-2) of Korea. DREAM is two-channel microwave radiometer with linear polarization, and operating at center frequencies of 23.8 GHz and 37 GHz. An equation for DREAM calibration is derived which accounts for losses and re-radiation in the microwave components of the radiometer due to physical temperature. This paper describes the radiometric calibration equation to get antenna temperature ($T_A$) from the measured output data. At lower altitude, the measured deep space temperature is contaminated by middle atmosphere and earth radiation. In this paper, we presented the detail mathematical formulation to find the altitude up to which cold source brightness temperature is not affected by earth and middle atmosphere radiation. The DREAMPFM data is used to calculate the performance parameters (linearity, sensitivity, dynamic range, and etc.) of the system.

  • PDF