고 에너지 방사선치료 시 GEANT4-DICOM과 TPS간 선량비교 연구 (A Comparative Study on the Dose of GEANT4-DICOM to TPS for High-Energy Radiation Treatment)

  • 곽근탁;김양수;권형철;김정수;이선영
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제41권6호
    • /
    • pp.567-572
    • /
    • 2018
  • Radiation therapy is one of the beneficial choices in the treatment of cancer. This is a comparison of TPS(Treatment Planning System) and GEANT4-DICOM, which should be preceded by the best radiation therapy. A treatment plan for prostate cancer was established with Eclipse and the point doses 366.1 cGy, 189.1 cGy, 213.4 cGy, 127 cGy, 105.7 cGy of any five prostate, bladder, rectum, right femoral head and left femoral head were identified. GEANT4-DICOM simulation showed that the results of Eclipse and ${\pm}2%$ dose error were confirmed. The monthly X-ray output agreement management value recommended by TG-142 is ${\pm}2%$, which means that the experimental results can be meaningful. In conclusion, GEANT4-DICOM is an infinite way to obtain more extended dose information once the time constraints are overcome in the simulation.

Acceptance Testing and Commissioning of Robotic Intensity-Modulated Radiation Therapy M6 System Equipped with InCiseTM2 Multileaf Collimator

  • Yoon, Jeongmin;Park, Kwangwoo;Kim, Jin Sung;Kim, Yong Bae;Lee, Ho
    • 한국의학물리학회지:의학물리
    • /
    • 제29권1호
    • /
    • pp.8-15
    • /
    • 2018
  • This work reports the acceptance testing and commissioning experience of the Robotic Intensity-Modulated Radiation Therapy (IMRT) M6 system with a newly released $InCise^{TM}2$ Multileaf Collimator (MLC) installed at the Yonsei Cancer Center. Acceptance testing included a mechanical interdigitation test, leaf positional accuracy, leakage check, and End-to-End (E2E) tests. Beam data measurements included tissue-phantom ratios (TPRs), off-center ratios (OCRs), output factors collected at 11 field sizes (the smallest field size was $7.6mm{\times}7.7mm$ and largest field size was $115.0mm{\times}100.1mm$ at 800 mm source-to-axis distance), and open beam profiles. The beam model was verified by checking patient-specific quality assurance (QA) in four fiducial-inserted phantoms, using 10 intracranial and extracranial patient plans. All measurements for acceptance testing satisfied manufacturing specifications. Mean leaf position offsets using the Garden Fence test were found to be $0.01{\pm}0.06mm$ and $0.07{\pm}0.05mm$ for X1 and X2 leaf banks, respectively. Maximum and average leaf leakages were 0.20% and 0.18%, respectively. E2E tests for five tracking modes showed 0.26 mm (6D Skull), 0.3 mm (Fiducial), 0.26 mm (Xsight Spine), 0.62 mm (Xsight Lung), and 0.6 mm (Synchrony). TPRs, OCRs, output factors, and open beams measured under various conditions agreed with composite data provided from the manufacturer to within 2%. Patient-specific QA results were evaluated in two ways. Point dose measurements with an ion chamber were all within the 5% absolute-dose agreement, and relative-dose measurements using an array ion chamber detector all satisfied the 3%/3 mm gamma criterion for more than 90% of the measurement points. The Robotic IMRT M6 system equipped with the $InCise^{TM}2$ MLC was proven to be accurate and reliable.

출력인자 계산에 이용되는 등가면법의 타당성 연구 : 장방형 X-선 조사면에 대해서 안전한가\ulcorner (Application of the Equivalent-Field Method for Output Calculation: Is it safe for elongated x-ray fields\ulcorner)

  • Kim, Chang-Seon;Kim, Chul-Yong;Park, Myung-Sun
    • 한국의학물리학회지:의학물리
    • /
    • 제9권4호
    • /
    • pp.195-200
    • /
    • 1998
  • 연구 목적: 등가면법은 장방형의 X-선 조사면의 출력인자 계산에 널리 이용되고 있다. 본 연구에 서는 출력인자 계산시 등가면법의 적용에 영향을 줄 수 있는 선질, 조사면의 두 변의 길이의 비, 측정점의 깊이 등을 조사하였다. 또한 등가면법의 타당성이 유지되는 영역을 밝히는 어림계산법을 제시하였다. 대상 및 방법 : 본 연구에 사용된 X-선의 선원은 4-, 6-, l0-MV 이었다. 조사면의 폭을 5-40 cm 까지 변화시키고 각 조사면에서 두 변의 비를 1:1 에서 10:1 까지 변화시켰다. 조사면의 장방효과는 물팬톰을 이용하였으며, dmax, 5-cm, 10-cm 깊이에서 시행하였다. 장방형의 조사면과 각 조사면에 대한 등가정사각형면에서의 출력인자를 구하여 이들 두 방법에서의 차이를 나타냈다. 결과 및 토의: 장방형의 조사면과 이에 대응하는 등가면 간의 출력인자의 차이는 일반적으로 장방비가 커질수록 증가하였다. 장방형의 조사면에 대한 출력인자의 측정값은 일반적으로 각 조사면의 등가정사각형면을 이용하여 계산한 값보다 높게 나타나서 크게는 10%의 차이를 나타냈다. 똑같은 두 변의 비에 대하여 장방형의 조사면과 둥가정사각형면에 대한 출력인자의 차이는 조사면의 크기가 작을수록 크게 나타났다. 실험에 사용한 각각에서 선질의 종류와 각각의 선질에서 측정깊이에서 두 값은 큰 차이를 보이지 않았다. 결론 : 본 연구결과에 의하여 등가면법을 출력인자 계산에 사용할 경우 이를 판단할 어림계산법을 구할 수 있다. 한 변의 길이가 25-cm 이하인 조사면에 대하여 만일 장방비 < (0.48) (긴 변의 길이) - 0.5를 만족하는 경우에는 출력인자의 오차를 2% 안에서 등가면법을 이용할 수 있다. 이와는 다른 경우에는 출력인자를 직접 측정하여야 한다. 이러한 기준은 4-10MV X-선원에 대하여 10-cm 깊이의 측정점까지 타당하다.

  • PDF

Radiochromic film dosimetry for linac-based stereotactic radiosurgery

  • Han, Seung-Hee;Park, Suk-Won;Oh, Do-Hoon
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.302-304
    • /
    • 2002
  • In linac-based stereotactic radiosurgery, assuring the quality of the planning and delivery of external photon beam requires accurate evaluation of beam parameters, usually including output factors, tissue-phantom ratio and off-axis ratios, and measurement of actual dose distributions from simulated treatment. We're going to test the use of calibrated radio chromic film (Gafchromic film; type MD-55, Nuclear associate) using a Lumiscan 75 digitizer to measure absolute dose and relative dose distributions for linac-based radiosurgery unit Relative dose distribution of a human-style spherical acryl phantom were measured using radiochromic film and calculated by treatment planning system. The absolute dose at the sphere center was measured by radiochromic film and micro chamber (Exradin A-14, 0.009cc). What we want to demonstrate in this work, the 'well selected' radiochromic films when external photon beam are used in linac-based stereotactic radiosurgery are very accurate detector for dosimetry.

  • PDF

Worst-Case Estimate of Envelope Correlation Coefficient for Small MIMO Mobile Antennas Below 1 GHz

  • Zhao, Xing;Tak, Jinpil;Choi, Jaehoon
    • Journal of electromagnetic engineering and science
    • /
    • 제15권1호
    • /
    • pp.44-52
    • /
    • 2015
  • A worst-case estimate of an envelope correlation coefficient (ECC) is obtained for small multiple-input multiple-output (MIMO) mobile antennas operating below 1 GHz. The worst-case estimate is numerically derived in this paper using spherical and exponential wave functions. The derived result confirms that the worst-case ECC can be easily obtained from the rotation angle between the radiation patterns of two MIMO elements, which are attained directly from the amplitude of 2D electric field patterns without any additional phase and polarization information. As a practical example, MIMO mobile antennas with different antenna element arrangements are compared to verify the validity of the proposed worst-case estimate. Moreover, based on these analyses, we also suggest an effective approach to reduce the ECC of a small MIMO mobile antenna operating below 1 GHz by properly locating the antenna elements to make the radiation patterns perpendicular to each other.

Second order grating CCGSE-DFB 레이저 해석 (Concentric-Circle-Grating Surface Emitting (CCGSE)-DFB Laser with second order grating)

  • 박해령;김효창;이연호
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2000년도 추계종합학술대회 논문집(2)
    • /
    • pp.313-316
    • /
    • 2000
  • Concentric-Circle-Grating (CCG) cavity is analyzed by coupled mode theory. In this case concentric grating is acting as both feedback element and output coupler. In our calculations radiation loss terms are included in guided coupled mode equations. The surface-emitted field distribution is obtained in self-consistent manner.

  • PDF

고주파 공진형 인버터식 X-선 장치의 단시간 출력특성 비교 연구 (A Study on the Output Characteristics Comparison of High Frequency Resonant Inverter Type X-ray Generators in Short Exposure Time)

  • 정수복;이성길;임홍우;백형래
    • 전력전자학회논문지
    • /
    • 제4권1호
    • /
    • pp.66-72
    • /
    • 1999
  • 본 논문은 고주파 공진형 PWM 인버터식 X-선 장치의 인버터에 단상과 3상 전파정류방식 및 PSU 전원을 연결시켰을 때 나타나는 단시간 출력특성에 대해 분석하였다. X-선의 선질은 X-선관에 입력되는 DC 전압 파형에 의존한다. DC 출력전압 파형은 DC 전압전원의 고조파 왜곡에 의해 영향을 받는다. 이러한 관전압 파형의 왜곡은 X-선 출력의 직선성, 재현성 및 출력선질을 저하시킨다. 따라서 본 논문에서는 DC 출력전압 파형과 세 가지 형식의 DC 입력전원 형식에 따른 출력선량을 비교하였고 이에 따른 실험결과를 검토하였다.

주변 온도 영향에 따른 비분산 적외선 가스센서의 출력 특성 해석 (Analysis of Output Voltage Properties of Non-dispersive Infrared Gas Sensors According to Ambient Temperatures)

  • 박한길;이승환
    • 센서학회지
    • /
    • 제27권5호
    • /
    • pp.294-299
    • /
    • 2018
  • This article describes the output properties of non-dispersive infrared carbon dioxide($CO_2$) sensors resulting from the changes in ambient temperatures. After the developed sensor module was installed inside the gas chamber, the temperature was set to 267 K, 277 K, 300 K, and 314 K, and the concentrations of $CO_2$ gas were increased from 0 to 5,000 ppm. Then, the output voltage at each concentration was obtained. Through these experimental results, two observations were made. First, both the $CO_2$ sensor and the reference sensor showed an increase in the output voltages as the temperature rose from 0 ppm, Second, the full scale outputs of the $CO_2$ sensor grew as the temperature increased. The output characteristics were analyzed based on two factors: change in the radiant energy of the infrared light source and change in the absorptivity of $CO_2$ gas according to the ambient temperature. Additionally, temperature compensation methods were discussed.

정류방식에 따른 진단용 X-선 장치의 출력비교 (A Comparative Study on Output of Four Type Diagnostic X-ray Equipments)

  • 김정민
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제20권2호
    • /
    • pp.34-43
    • /
    • 1997
  • There are 4 types of equipment in diagnostic radiography. These are single phase, three phase, inverter type and condenser type X-ray generators. It is very confusing to make an adequate exposure factor and to know the usage of different type of X-ray generators. In this experiment, I explored a comparative study of outputs in 4 different type of X-ray units. I expect that this experiment could be helpful for manufacturer to make both the X-ray equipment better, In terms of Ideal exposure factors, thereby reducing the patient dose. Experimental results are as follow : 1) X-ray output The ratio of X-ray output of single, three phase and inverter type of X-ray generator was 1 : 1.6 : 2 without absorber and 1 : 2 : 2.6 with 20 mm aluminium absorber. 2) Beam quality The X-ray beam quality of single phase generator was proved to be softer than three phase and inverter type of generators by 0.4 mmAL and 0.55 mmAl HVL respectively. 3) Reproducibility Linearity of X-ray output Retroducibility of X-ray output met the regulation below CV 0.05 and linearity also met the regulation below 0.1 in 4 types of diagnostic X-ray generators. 4) The comparison of incident dose Three phase X-ray generator was 20% higher than two other X-ray generators in radiation dose to make same film density.

  • PDF

다중 조사면 치료 시 기계적 입력치(MU)에 따른 선량적 안정성에 대한 연구 (A Study of Dose Stability at Low Monitor Unit Setting for Multiple Irradiated Field)

  • 김주호;이상규;신현경;이석;나수경;조정희;김동욱
    • 대한방사선치료학회지
    • /
    • 제17권2호
    • /
    • pp.155-160
    • /
    • 2005
  • 목 적 : 전산화단층 모의치료조준(CT simulation)과 선량 계획 장비(RTP)의 발전으로 많은 저자들에 의해 종양부 위의 선량을 증가시키고 인접한 장기의 선량을 효과적으로 감소시킬 수 있는 3차원 입체 조형 치료(Conformal therapy)와 조사면내 선량 보강 기법(Field in field technique)이 자주 소개되어지고 있다. 이러한 치료 기법은 많은 수의 조사면을 사용함으로써 조사면이 증가할수록 10 MU이하의 극히 적은 기계적 입력치(monitor unit, MU)를 사용하기도 한다. 통상 일반적으로 사용되어지는 선량에 대한 정보(beam data)는 이보다 훨씬 많은 100 MU이상 혹은 그보다 높은 안정적인 출력을 기대할 수 있는 상태에서 측정되어지므로 극히 적은 기계적 입력치에서도 기존에 측정되어진 선량 정보와 동일한 선량분포를 구현할 수 있는지 반드시 확인하여야 한다. 따라서 본 연구에서는 극히 적은 기계적 입력치(MU)에서의 선량적 안정성을 알아보고 향후 정도 관리지침에 활용코자 한다. 대상 및 방법 : 본원에서 사용 중인 선형가속기 Varian 2100C/D의 6 MV, 10 MV(USA)와 Varinan 600C의 4 MV(USA)의 에너지를 사용하여 $10{\times}10cm^2$ 조사면에서 90 MU를 90 MU, 45 MU, 30 MU, 18 MU, 9 MU, 6 MU로 각각 1, 2, 3, 5, 10, 15 회씩 나누어 조사하였다. 전리함(pinpoint farmer type chamber, PTW, GERMANY)를 이용하며 4 MV, 6 MV는 5 cm, 10 MV는 10 cm 깊이, SAD 100 cm에서 물 팬텀을 이용하며 조사면내의 출력을 측정하였고, 측정용 필름(X-omat V, Kodak, USA)을 이용하며 높은 선량을 나타내는 90 MU, 30 MU에서의 편평도와, 대칭도를 비교하였고 일반적인 medical film(AGFA USA)을 이용하여 낮은 선량을 보이는 9MU에서 조사면내 편평도와, 대칭도를 비교하여 선질의 특성 변화를 관찰하였다. 결 과 : 전리함을 이용한 측정에서 2100C/D는 90 MU와 9 MU에서 1 MU 당 선량(cGy/MU)은 6 MV와 10 MV에서 90 MU를 1회에 조사한 것과 비교하여 약 1.6% 정도 증가하였고 2100C는 0.5%, 1.3%가 각각 증가하였다. 600C 또한 1.6% 증가하였으나 6 MU에서 약 3% 차이를 나타내었다. 편평도와 대칭도는 장비와 에너지에 따라 1%에 2.9%까지 차이가 있었으나 전체적으로 적은 MU에서 약간 더 균등하였고 극히 적은 MU로 인한 차이는 확인할 수 없었다. 결 론 : 각각의 실험에서 선량적 차이는 허용되어지는 범위이하의(출력<3%, 편평도<${\pm}3%$, 대칭도<2%, ICRU report 50)오차를 모임으로써 보유한 장비에 따라 정도에 차이는 있을 수 있으나 본원에서 사용 중인 장비에서 극히 적은 MU의 사용이 현저한 선량적 오차를 유발하진 않는 것으로 사료되어진다. 그러나 정도 관리 시 그 오차를 확인하는 과정은 장비의 사용과 수명에 따라 지속적으로 관리되어져야 할 것이다.

  • PDF