• 제목/요약/키워드: Radiation Measure

검색결과 808건 처리시간 0.033초

Soil-to-Plant Transfer of $^{54}Mn,\;^{60}Co,\;^{85}Sr$ and $^{137}Cs$ Deposited during the Growing Season of Potato (감자의 재배기간 중 토양에 침적한 $^{54}Mn,\;^{60}Co,\;^{85}Sr,\;^{137}Cs$의 작물체로의 전이)

  • Choi, Yong-Ho;Lim, Kwang-Muk;Jun, In;Keum, Dong-Kwon
    • Journal of Radiation Protection and Research
    • /
    • 제33권3호
    • /
    • pp.105-112
    • /
    • 2008
  • To measure the soil-to-plant transfer factors ($TF_a,\;m^2\;kg^{-1}$-fresh) of radionuclides deposited during the growing season of potato, a radioactive solution containing $^{54}Mn,\;^{60}Co,\;^{85}Sr$ and $^{137}Cs$ was applied to the soil surfaces in soil boxes 2 d before seeding and three different times during the plant growth. For the pre-seeding application (PSA), radionuclides were mixed with the topsoil (loamy sand and 5.2 in pH). The plant parts investigated were leaves, stems, tuber skin and tuber flesh. The $TF_a$ values of $^{54}Mn,\;^{60}Co,\;^{85}Sr$ and $^{137}Cs$ from the PSA were in the ranges of $1.9{\times}10^{-4}{\sim}1.5{\times}10^{-2}$, $1.8{\times}10^{-4}{\sim}7.5{\times}10^{-4}$, $4.0{\times}10^{-4}{\sim}1.6{\times}10^{-2}$, $1.5{\times}10^{-4}{\sim}3.9{\times}10^{-4}$ respectively, for different plant parts. The TFa values from the growing-time applications were on the whole a few times lower than those from the PSA. For $^{54}Mn,\;^{85}Sr$ and $^{137}Cs$, the $TF_a$ values from the early- or middle-growth-stage application were higher than those from the late-growth-stage application, whereas the opposite was true for $^{60}Co$. Leaves and tuber flesh had the highest and lowest $TF_a$ values, respectively, in most cases. The total uptake from soil by the four plant parts was in the range of $0.05{\sim}3.16%$. In the third year following the PSA, the $TF_a$ values of $^{54}Mn,\;^{60}Co$ and $^{137}Cs$ were $11{\sim}25%$, $21{\sim}25%$ and $38{\sim}67%$ of those in the first year, respectively, depending on the plant parts. The present results can be used for estimating the radiological impact of an acute radioactive deposition during the growing season of potato and for testing the validity of relevant food-chain models.

Evaluation on the Accuracy of the PPS in the Proton Therapy System, Which Uses the Self Made QA Phantom (자체 제작한 QA Phantom을 이용한 양성자 PPS (Patient Positioning System)의 정확성 평가)

  • Lee, Ji-Eun;Kim, Jae-Won;Kang, Dong-Yoon;Choi, Jae-Hyeok;Yeom, Du-Seok
    • The Journal of Korean Society for Radiation Therapy
    • /
    • 제24권2호
    • /
    • pp.115-121
    • /
    • 2012
  • Purpose: The process of the proton treatment is done by comparing the DRR and DIPS anatomic structure to find the correction factor and use the PPS to use this factor in the treatment. For the accuracy of the patient set up, the PPS uses a 6 axis system to move. Therefore, there needs to be an evaluation for the accuracy between the PPS moving materialization and DIPS correction factor. In order to do this, we will use a self made PPS QA Phantom to measure the accuracy of the PPS. Materials and Methods: We set up a PPS QA Phantom at the center to which a lead marker is attached, which will act instead of the patient anatomic structure. We will use random values to create the 6 axis motions and move the PPS QA Phantom. Then we attain a DIPS image and compare with the DRR image in order to evaluate the accuracy of the correction factor. Results: The average correction factor, after moving the PPS QA Phantom's X, Y, Z axis coordinates together from 1~5 cm, 1 cm at a time, and coming back to the center, are 0.04 cm, 0.026 cm, 0.022 cm, $0.22^{\circ}$, $0.24^{\circ}$, $0^{\circ}$ on the PPS 6 axis. The average correction rate when moving the 6way movement coordinates all from 1 to 2 were 0.06 cm, 0.01 cm, 0.02 cm, $0.1^{\circ}$, $0.3^{\circ}$, $0^{\circ}$ when moved 1 and 0.02 cm, 0.04 cm, 0.01 cm, $0.3^{\circ}$, $0.5^{\circ}$, $0^{\circ}$ when moved 2. Conclusion: After evaluating the correction rates when they come back to the center, we could tell that the Lateral, Longitudinal, Vertical were all in the acceptable scope of 0.5 cm and Rotation, Pitch, Roll were all in the acceptable scope of $1^{\circ}$. Still, for a more accurate proton therapy treatment, we must try to further enhance the image of the DIPS matching system, and exercise regular QA on the equipment to reduce the current rate of mechanical errors.

  • PDF

Image-based Absorbed Dosimetry of Radioisotope (영상기반 방사성동위원소 흡수선량 평가)

  • Park, Yong Sung;Lee, Yong Jin;Kim, Wook;Ji, Young Hoon;Kim, Kum Bae;Kang, Joo Hyun;Lim, Sang Moo;Woo, Sang-Keun
    • Progress in Medical Physics
    • /
    • 제27권2호
    • /
    • pp.86-92
    • /
    • 2016
  • An absorbed dose calculation method using a digital phantom is implemented in normal organs. This method cannot be employed for calculating the absorbed dose of tumor. In this study, we measure the S-value for calculating the absorbed dose of each organ and tumor. We inject a radioisotope into a torso phantom and perform Monte Carlo simulation based on the CT data. The torso phantom has lung, liver, spinal, cylinder, and tumor simulated using a spherical phantom. The radioactivity of the actual absorbed dose is measured using the injected dose of the radioisotope, which is Cu-64 73.85 MBq, and detected using a glass dosimeter in the torso phantom. To perform the Monte Carlo simulation, the information on each organ and tumor acquired using the PET/CT and CT data provides anatomical information. The anatomical information is offered above mean value and manually segmented for each organ and tumor. The residence time of the radioisotope in each organ and tumor is calculated using the time activity curve of Cu-64 radioactivity. The S-values of each organ and tumor are calculated based on the Monte Carlo simulation data using the spatial coordinate, voxel size, and density information. The absorbed dose is evaluated using that obtained through the Monte Carlo simulation and the S-value and the residence time in each organ and tumor. The absorbed dose in liver, tumor1, and tumor2 is 4.52E-02, 4.61E-02, and 5.98E-02 mGy/MBq, respectively. The difference in the absorbed dose measured using the glass dosimeter and that obtained through the Monte Carlo simulation data is within 12.3%. The result of this study is that the absorbed dose obtained using an image can evaluate each difference region and size of a region of interest.

In Tomotherapy, for the Maintenance of Body Temperature due to Substance Use, Changes in Dose Assessment in the Organization (TOMO 치료 시 체온 유지를 위한 물질 사용에 따른 조직 내 선량 변화 평가)

  • Hwang, Jae-Woong;Jeong, Do-Hyeong;Kim, Dae-Woong;Yang, Jin-Ho;Choi, Gye-Suk
    • The Journal of Korean Society for Radiation Therapy
    • /
    • 제22권2호
    • /
    • pp.131-134
    • /
    • 2010
  • Purpose: TOMO therapy treatment for a relatively long run Beam time and temperature-sensitive detector, such as CT clinics in optimal temperature ($20~21^{\circ}$) to maintain a constant temperature in addition to its own Chamber Cooling system is activating. TOMO This clinic has been reduced in the patients' body temperature to keep the sheets and covers over the treated area. Therefore, these materials for any changes in the organization gives the dose were analyzed. Materials and Methods: To compare changes in the organization Dose Phantom cheese (Cheese Phantom) were used, CT-simulation taking the center point of the cheese phantom PTV (Planning Target Volume, treatment planning target volume) by setting Daily dose 200 cGy, 3 meetings planned treatment. PTV, PTV +7 cm, PTV +14 cm, the total count points on the phantom using the Ion chamber cover without any substance to measure the dose, and one of the most commonly used treatment, including the frequently used four kinds of bedding materials (febric 0.8 mm, gown 1.4 mm, rug, 3.3 mm, blanket 13.7 mm) and covered with a phantom and the dose measured at the same location were analyzed 3 times each. Results: PTV, PTV +7 cm, PTV +14 cm from the point of any substance measured in the state are covered with four kinds of materials (fabric, gown, rug, blanket) was measured in the covered states and compares their results, PTV respectively -0.17%, -0.44%, -0.53% and -0.9% change, PTV +7 cm, respectively -0.04%, +0.07%, +0.06%, +0.07%, were changed, PTV +14 cm, respectively 0%, -0.06%, -0.02%, +0.6%, respectively. Conclusion: These results TOMO treatment to patients to maintain their body mass by using PTV thickness of the material decreased in proportion to. PTV +7 cm, but showed slight changes in the point, PTV +14 cm at the point of the dose was increased a little. Sejijeom all the difference in treatment tolerance ${\pm}3%$ range, this is confirmed in the coming treatment will not affect the larger should be considered.

  • PDF

A Survey on Radiation Exposure of Patient in Mammography (유방 X선촬영 시 피폭선량에 대한 조사 연구)

  • Kim, Hyung-Chul;Cho, Pyung-Gon;Kim, Sung-Soo;Choi, Jong-Hak;Kim, You-Hyun
    • Journal of radiological science and technology
    • /
    • 제27권4호
    • /
    • pp.55-60
    • /
    • 2004
  • The purpose of this study was to examine both patient exposure dose during mammography and the utility status of mammograpy equipments. The data of this study were collected through questionnaire survey for 278 medical facilities registered at Korean Hospital Association and finally 161 medical facilities's data were analyzed. According to data analysis, medical facilities of 14.9% used the average glandular dose of less than 0.5 mGy, $0.51{\sim}1.0\;mGy$ 8.6%, $1.01{\sim}1.5\;mGy$ 14.9%, $1.51{\sim}2.0\;mGy$ 11.1%, $2.01{\sim}2.5\;mGy$ 9.8%, $2.51{\sim}3.0\;mGy$ 33.3%, and 7.4% more than 3.01 mGy. It was found that medical facilities of 92.6% used less than 3 mGy, showing that this figure is similar to the limit value of 3 mGy recommended by Korea Food & Drug Administration(KFDA). Recently, international organizations such as ICRP associated with radiation protection suggests that less than 3 mGy of average mammary gland dose be used during mammography in case of using Mo target+Mo filter, film/screen system and craniocaudal projection with the breast pressed to 4.2 cm. The standard dose is being strictly observed and that of the limits is going down to 2 mGy or 1.5 mGy. The major results of this study indicate that interests and a counterplan to reduce patient dose during mammography should be considered. Based on this study, the authors of this study will continue to measure exposure dose to set a new standard for patient exposure dose during mammography.

  • PDF

A Study of Radiation Incidence Angle in Anteroposterior Cervical Vertebra Examination (경추 정면 검사에서 방사선 입사각에 관한 연구)

  • Jeung, Seung-Woon;Lim, Cheong-Hwan;Han, Beom-Hee;Jung, Hong-Ryang;Joo, Yeong-Cheol;Park, Mi-Ja
    • Journal of radiological science and technology
    • /
    • 제35권2호
    • /
    • pp.83-92
    • /
    • 2012
  • In anteroposterior projection for cervical vertebra, it is general that the incidence angle of X-ray is $15^{\circ}$ to $20^{\circ}$ degrees to head in order to prevent overlap of mandible and occipital bone and to observe array of cervical interbody and shapes of joints. However, the angle is appropriate for foreigners that was determined by foreign literature review long ago, and there have been few researches of incidence angle for Koreans' body type. The purpose of in this study are to identify the incidence angle appropriate for Koreans and to present methodology. In order to measure the incidence angle, 1,044 patients who visited S Hospital located in Seosan were selected and measured of average length of cervical vertebra, OID, axis angle, and FID. The incidence angle was calculated from the applied formula by measuring average values per age groups and sex (see Formula 1 and 2). The average length of cervical vertebra was 6cm: the length was increased from teenagers to twenties but was decreased since thirties. The difference between males and females was around 1cm (p<.01). The OID was almost the same regardless of age groups and sex. As for axis angle, the slope was increased in teenagers and twenties, but was decreased since thirties. The difference between males and females was around 2 degrees (p<.01). The FID measurements were almost the same regardless of age groups and sex, and when the incidence angle was measured from these values, the teenagers were $15.9^{\circ}$, the twenties were $16.9^{\circ}$, the thirties were $16.6^{\circ}$, the forties were $16.2^{\circ}$, the fifties were $15.9^{\circ}$, and the sixties were $14.5^{\circ}$, indicating that the angle was increased from teenagers to the twenties but decreased since the thirties. While the angles of males and females were measured to be the same in the teenagers, the angle was different between males and females by $2^{\circ}$. When the incidence angle statistically analyzed with measurement of average length of cervical vertebra, OID, axis angle, and FID, all of them were shown to have correlations with the incidence angle (p<.01). Conclusively, it was shown that the incidence angle was measured differently from average length of cervical vertebra, OID, FID, and axis slope, as well as from age and sex. Therefore, it can be suggested that the anteroposterior radiation test for cervical vertebra should be conducted by different incidence angles based on age and sex. The data of this study may be used as reference in determining the incidence angle of cervical vertebra tests for the future.

An Analysis of Thermal Comforts for Pedestrians by WBGT Measurement on the Urban Street Greens (도심 가로 녹음의 습구흑구온도(WBGT) 측정을 통한 보행자 열쾌적성 효과 분석)

  • Ahn, Tong-Mahn;Lee, Jae-Won;Kim, Bo-Ram;Yoon, Ho-Seon;Son, Seung-Woo;Choi, Yoo;Lee, Na-Rae;Lee, Ji-Young;Kim, Hae-Ryung
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • 제41권3호
    • /
    • pp.22-30
    • /
    • 2013
  • This study aims to measure the thermal comfort effects of urban street trees. As the usual dry bulb air temperature does not indicate properly how the average pedestrian feels the heat of a typical summer day under the strong sunshine, we adopted the Wet Bulb Globe Temperature(WBGT). WBGT involves black globe temperature to measure the direct radiation of sun beams on our bodies, for example our heads. We measured temperatures on very sunny and hot summer days, August 3, 4, and 7, 2012, on the urban streets of Seoul, Korea. Wet bulb, globe, and dry bulb temperatures were measured under direct sunlight from 1 O'clock to 5 O'clock pm. Globe and dry bulb temperatures were measured under street tree shades nearby during the same hours. Then the WBGTs were calculated with the formulae, one for sunny outdoor spaces, and the other for shaded outdoor spaces or indoor. The results are compared with the Korean Standards Association(KS A ISO 7243). The major findings were: 1) On very sunny and hot summer days in Seoul, street tree shades lower the WBGT about 1 to 4 degrees, 2) during the hours of 3 and 4 O'clock in the afternoon, the WBGT under the tree shades are about 3 to 4 degrees lower compared to those under sunshines(approx. 29 to 32 degrees respectively), 3) This difference makes a major thermal comfort for urban pedestrians because senior citizens or weak persons are recommended to move indoor, and even healthy people are recommended stop outdoor sports and take rests in the shades when WBGT is about 32. On the other hand, if the WBGT is around 29, or 3 degrees lower, slower walking, light works or sports are allowable, 4) On site questionnaire survey confirms the thermal comforts under the tree shades, and we even could not get survey subjects on the sunny parts of the sidewalks, 5) We strongly recommend change of guidelines for urban street trees from "one row of street trees on 6m~8m intervals" to "street trees to make continuous shades".

A Study of Bleaching Phenomenon of Otter (Lutra lutra) Spraints in Relation to Weather Conditions and Characteristics of Sprainting Sites (기상조건과 배설지 특성에 따른 수달(Lutra lutra) 분변의 표백현상에 관한 연구)

  • Noh, Eun-Young;Han, Sung-Yong;Yoo, Jeong-Chil
    • Journal of Wetlands Research
    • /
    • 제17권1호
    • /
    • pp.1-10
    • /
    • 2015
  • The bleaching phenomenon of otter spraints is indicates that the age of spraints (fresh or old spraints). As previous studies on the old otter faeces (spraint) have focused only on the external changes of spraints, it has been difficult to explain the difference of the decomposition rates among old spraints. We hypothesized that the micrometeorology difference caused by various characteristics of sprainting sites such as porosity and consistency of soil could affect the extent of the decomposition rate, the solar bleaching phenomenon of spraints used as a measure of the patterns of old spraints. Sprainting sites were classified into four types (Clay, Sand, Rock and Concrete spot) and each type was divided into two groups according to the sunlight condition (Sunny site and Shady site) to measure the effect of solar radiation. Micrometeorology of the sites were evaluated by measuring temperatures and humidities of the sites during the whole season. The variations in micrometeorology of the sunny sites according to the sprainting site types were examined with correlation analyses between the factors of micrometeorology. The analyses on the bleaching phenomenon of the spraints by micrometeorology showed that the highest rate of bleaching was found at the 'Rock spot' and 'Concrete spot' of the sunny site and especially in summer, the highest rate of bleaching ($63.4{\pm}7.6%$) was found at the 'Clay spot' of the sunny sites. The lowest rate of bleaching was found at the 'Sand spot' of the sunny sites. The above findings show that the difference in bleaching rates among sprainting sites was due to the seasonal or sunny condition. In addition, we found that the differences in thermal conductivity among sprainting site characteristics have resulted in different sprainting site temperature which have affected the rate of bleaching of spraints. In conclusion, this study suggests that studies of otters on their population size and home ranges using spraints as an indirect sign, should consider the effects of sprainting site characteristics and weather conditions.

Seasonal Variations of Evapotranspiration Observed in a Mixed forest in the Seolmacheon Catchment (설마천 유역의 혼효림에서 관측된 증발산의 계절변화)

  • Kwon, Hyo-Jung;Lee, Jung-Hoon;Lee, Yeon-Kil;Lee, Jin-Won;Jung, Sung-Won;Kim, Joon
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • 제11권1호
    • /
    • pp.39-47
    • /
    • 2009
  • The importance of securing water resources and their efficient management has attracted more attention recently due to water deficit. In water budget analysis, however, evapotranspiration(${\lambda}E$) has been approximated as the residual in the water balance equation or estimated from empirical equations and assumptions. To minimize the uncertainties in these estimates, it is necessary to directly measure ${\lambda}E$. In this study, using the eddy covariance technique, we have measured ${\lambda}E$ in a mixed forest in the Seolmacheon catchment in Korea from September 2007 to December 2008. During the growing season(May-July), ${\lambda}E$ in this mixed forest averaged about $2.2\;mm\;d^{-1}$, whereas it was on average $0.5\;mm\;d^{-1}$ during the non-growing season in winter. The annual total ${\lambda}E$ in 2008 was $581\;mm\;y^{-1}$, which is about 1/3 of the annual precipitation of 1997 mm. Despite the differences in the amount and frequency of precipitation, the accumulated ${\lambda}E$ during the overlapping period(i.e., September to December) for 2007 and 2008 was both ${\sim}110$ mm, showing virtually no difference. The omega factor, which is a measure of decoupling between forest and the atmosphere, was on average 0.5, indicating that the contributions of equilibrium ${\lambda}E$ and imposed ${\lambda}E$ to the total ${\lambda}E$ were about the same. The results suggest that ${\lambda}E$ in this mixed forest was controlled by various factors such as net radiation, vapor pressure deficit, and canopy conductance. In this study, based on the direct measurements of ${\lambda}E$, we have quantified the relative contribution of ${\lambda}E$ in the water balance of a mixed forest in the Seolmacheon catchment. In combination with runoff data, the information on ${\lambda}E$ would greatly enhance the reliability of water budget analysis in this catchment.

Measurement of Effective Half-life Using Dual Time I-131 Whole Body Scan in Patients with Differentiated Thyroid Cancer Treated by High Dose Therapy (고용량 방사성옥소 치료를 받은 갑상선분화암 환자에서 Dual Time I-131 Whole Body Scan을 이용한 유효반감기의 측정)

  • Yoon, Jae Sik;Lee, Jae Gon;Lee, Ki Hyun;Lim, Kwang Seok;Choi, Hak Ki;Lee, Sang Mi
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • 제18권1호
    • /
    • pp.98-103
    • /
    • 2014
  • Purpose: The effective half life of I-131 is useful to calculate radiation dose, period of hospitalization, and exposure dose of surrounding people from patient. However, it is difficult to measure. This study estimates the effective half life in whole body and thyroid in using of value of residual radioactivity obtained from the early and delay images of Dual time I-131 whole body scan. Also, the correlations between the effective half life and serum creatinine, GFR, and administration dose were investigated in this study. Materials and Methods: The targets were 50 patients administration high dose of I-131 from February to August in 2013, having normal range of serum creatinine and over $30{\mu}IU/mL$ of TSH levels. After administration radioactive I-131, the early scan in the 3rd day and the delay scan in the 5-6th days were performed. To measure the residual radioactivity in the whole body and thyroid, ROI was set and then background radioactivity was corrected to estimate. The effective half life was estimated by calculating the ratio of measured values between the early and delay images. To compare the effective half lives of the whole body and thyroid, it was analyzed by Independent t-test, and each correlation of the effective half life, GFR, serum creatinine, and the dose of administration were analyzed by calculating the pearson's correlation coefficient. All of the analysis were determined to be statistically significant when P<0.05. Results: The effective half life of the whole body was $17.06{\pm}5.50$ hours and of the thyroid was $17.22{\pm}5.41$ hours. The two effective half life did not show significant difference (P=0.887). As the value of GFR was increased, the effective half life of whole body (r=-0.407, P=0.003) and of thyroid (r=-0.473, P=0.001) were significantly decreased; as the value of serum creatinine was increased, the effective half life of whole body (r=0.309, P=0.029) and of thyroid (r=0.371, P=0.008) were significantly increased. In the administration dose, effective half life did not have correlations. Conclusion: The effective half life of I-131 of patients treated for their thyroids were estimated only by using the images of Dual time I-131 whole body scan. Also, the correlations with the effective life, GFR, and serum creatinine were examined. This study might be utilized for a study on optimization for the period of hospitalization of patients treated by high dose of I-131 and on evaluation for internal absorbed dose of MIRD schema in application of the effective half life.

  • PDF