Characteristics of Radiated Electromagnetic Fields From A Cylindrical Cavity (원통형 캐비티에서 방출되는 방사 전자파 특성)

  • Kim, Hyo-Gyun;Cho, Jun-Ho;Lim, Dong-young;Kim, Ki-Chai
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.2
    • /
    • pp.237-244
    • /
    • 2016
  • This paper, presents the characteristics of electromagnetic fields radiated from a pole-transformer. The cylindrical cavity is used to measure electromagnetic fields radiated from a pole-transformer when partial discharge occures inside the pole-transformer. The theoretical analysis is conducted by a finite difference time domain (FDTD) method. As a result, frequency characteristics of the radiated electromagnetic waves emitted from the inside the cavity to the outside through the 1st and 2nd bushings could be observed for the configuration of the cylindrical cavity with a radiation window. The frequency characteristics of electromagnetic field are also studied according to the enclosure structure of the cylindrical cavity. To verify the theoretical analysis, computed results are compared to experimental results.

Characteristics of Charge Accumulation in Glass Materials under E-Beam Irradiation (E-빔 조사하에서 유리의 전하축퇴 특성)

  • Choi, Yong-Sung;Lee, Kyung-Sup
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.377-378
    • /
    • 2008
  • Space charge formation in various glass materials under electron beam irradiation was investigated. Charging of spacecraft occurs in plasma and radiation environment. Especially, we focused on an accident caused by internal charging in a glass material that was used as the cover plate of solar panel array, and tried to measure the charge distribution in glass materials under electron beam irradiation by using a PEA (Pulsed Electro-Acoustic method) system. In the case of a quartz glass (pure $SiO_2$), no charge accumulation was observed either during or after the electron beam irradiation. On the contrary, positive charge accumulation was observed in glass samples containing metal-oxide components. It is found that the polarity of the observed charges depends on the contents of the impurities. To identify which impurity dominates the polarity of the accumulated charge, we measured charge distributions in several glass materials containing various metal-oxide components and calculated the trap energy depths from the charge decay characteristics of all glass samples. Furthermore, the dependence of the polarity of accumulated charges on the component of glass materials is discussed by using the models of energy bands.

  • PDF

A Study on the Solar Distillation in a Cube with Tilted Angles (경사진 육면체에서의 태양열에 의한 증발 현상에 대한 연구)

  • Park, Yeong-Hoon;Kim, Byung-Chul
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1424-1429
    • /
    • 2004
  • Distillation is one of many processes that can be used for the purification of water. It requires an energy input such as heat and solar radiation is a possible source of energy. In this process, water is evaporated, thus separating water vapor from the solute. The vapor is then condensed to pure water. The temperature of the water, the cavity of the enclosure and the surface of the glass was measured everyday. Fifteen points were chosen for the temperature measure using a thermocouple. The inner wall and the bottom of each still was painted black for good absorption of heat. The enforced glass was used for the cover for the entering of solar energy. The size of all of the water baths was the same, but the glass of the rectangular form had a tilted angle. In the case of fine or general weather, the volume of condensed water produced by $45^{\circ}$ and $60^{\circ}$ is very irregular compared to that of $15^{\circ}$ and $30^{\circ}$, In case of a rainy day, the occurrence of the volume of condensed water was similar to that of $15^{\circ}$ and $30^{\circ}$, but the volume of condensed water produced by $30^{\circ}$ was the highest.

  • PDF

Performance Evaluation of Heat Radiant for 50W LED by the CNT Thermal Interface Material (CNT 열전달 물질에 의한 50W LED의 방열 성능평가)

  • Cho, Young-Tae;Lee, Choong-Ho
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.13 no.6
    • /
    • pp.23-29
    • /
    • 2014
  • In this study, cooling and heat-transfer tests are performed to compare and evaluate the thermal conductivity in a prepared CNT TIM (thermal interface material). A polymerized CNT heat-transfer resin and commercial thermal grease (Shinetsu G-747) were applied for a comparison test in both cases. Cooling experiments with an aluminum foil specimen were performed in order to measure the temperature distribution using an infrared camera, and in heat radiation experiments, performance testing of the thermal conductivity was conducted using high-power LEDs. Carbon resin with the polymerization of graphite and carbon black, and CNT-polymerized CNT resin with graphite and carbon black were tested and compared with using G-747. It was found that the cooling performance and the heat transfer ability in both the carbon resin and the CNT-polymerized CNT resin were greater than those of G-747 because the temperature by 5. $0^{\circ}C$ in both cases appeared lower than that of the G-747.

Performance evaluation of bubble pump used on solar water heating system

  • Xuesong, Li;Park, Gi-Tae;Kim, Pil-Hwan;Chung, Han-Shik;Jeong, Hyo-Min
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.416-422
    • /
    • 2007
  • The application analysis of bubble pump on the domestic solar water heater system is presented. The system investigated in this study is a passive device, self pumping and self regulating. It was test to use the bubble pump on solar water heater system. The test experiment has been taken on the existed vacuum tube about the efficiency, working fluid temperature and pressure and circulated power. In order to check the working temperature and working pressure effectively, the bubble pump was test separated from the solar water heater. The equipment consists of the bubble pump, heater and heat exchanger. The main structure of bubble pump was design depend on the character of two phase flow. The complete system was instrumented to measure pressures, temperatures and their relationship with the solar radiation intensity. The theory analysis of design bubble pump has been given and the experiment result analysis has been included in the paper.

  • PDF

SPF Evaluation and Safety of Sunscreen Products (자외선 차단 제품의 SPF 측정과 안전성)

  • 김종일;이병곤;고재숙
    • Proceedings of the SCSK Conference
    • /
    • 1992.09a
    • /
    • pp.5-26
    • /
    • 1992
  • Many methods of in vitro SPF evaluation have been developed in order to measure SPF of sunscreen products. In this study, we compared two spectrophotometric in vitro measurements using the skin cast made of Luviset CAP- $X^{R}$ resin and Transpor $e^{R}$ tape as substrate with two in vivo measurements using guinea pig and human. And we also observed the radiation reaching on the earth's surface in Seoul for one year and the change of the primary skin irritancy along the change of SPF value. According to the our research, the first, in vivo measurement using guinea pig had the close agreement with SPF measurement using human and showed the tendancy that guinea pig SPF was lower than human SPF. The second, there was the good relationship between in vitro SPF by using Transpor $e^{R}$ tape and in vivo SPF, and it is possible to predict human SPF from Protection Index(PI) by using tape. The third, it is thought that SPE 20 is reasonable value because of UV intensity in Seoul and the primary skin irritancy of higher SPF than 25. So we propose that it is important to distinguish the sunscreen product having higher than approximate 25 from the category of general cosmetics including lower SPF sunscreen product.oduct.

  • PDF

Mitigating the Urban Heat Island Phenomenon Using a Water-Retentive Artificial Turf System

  • Tebakari, Taichi;Maruyama, Tatsuya;Inui, Masahiro
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2010.05a
    • /
    • pp.91-100
    • /
    • 2010
  • To investigate the thermal properties of a water-retentive artificial turf system (W-ATS), we estimated hydrologic parameters including thermal conductivity, heat capacity, and surface albedo for both the W-ATS and natural grass. We used a model experiment to measure surface temperature and evaporation for both the W-ATS and natural grass. We found that the W-ATS had lower thermal conductivity than natural grass did, and it was difficult for the W-ATS to convey radiant heat to the ground. Compared to natural grass, the W-ATS also had lower heat capacity, which contributed to its larger variation in surface temperature: the W-ATS had higher surface temperatures during daytime and lower surface temperatures during nighttime. The albedo of the W-ATS was one-quarter that of natural grass, and reflected shortwave radiation from the W-ATS surface was lower than that from the surface of natural grass. These results indicate that the W-ATS caused the soil temperature to increase. Furthermore, evaporation from the W-ATS was one-quarter the value of evapotranspiration from natural grass.

  • PDF

A Method for Quantifying Spectrum Use (스펙트럼 이용 계량화 방법)

  • 김영수;이형수;정영호;김상원;정진욱
    • The Proceeding of the Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.6 no.3
    • /
    • pp.24-35
    • /
    • 1995
  • In this paper, we study the Spectrum Use Measure(SUM) model for quantifying the extent of spectrum use by existing radio communication systems. This model calculates the interference level between transmitters and receivers by applying the EMC analysis technique of interference prediction process such as antenna radiation pattern model and propagation model which are well known. While several previous works have described the spectrum resources by constructing the interference contours around existing radio systems, the SUM technique is developed for quantifying and portraying the spectrum resources used by radio communication systems in a geographic area. Computer simula- tion results are illustrated to verify the calculations for the Spectrum Use Bandwidth(SUB) and Spectrum Use Factor (SUF) performed by the SUM model and find the usefulness of the SUM model.

  • PDF

The Image Resolution Compare to Having Lead Plate or Not Lumbar Lateral Projection

  • Kim, Hyun-Soo;Min, Jung-Whan;Dong, Kyung-Rae
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.13 no.4
    • /
    • pp.145-151
    • /
    • 2011
  • The purpose of this study is to know some changes of resolution and image if we remove scattered ray using lead plate when doing lumbar lateral projection. Using 3 DR system(2 FD types, 1 CCD type) equipments and 2 film system equipments, we gain the image whether the phantom of abdomen equivalent sticking resolution chart has lead plate or not, whether we do collimation or not. Also, we use ion chamber, measure radiation exposure rate and change to entrance surface dose from it. we gain that images in the greatest condition of taking in clinic. 5 people in this group decoded resolution with our eyes, measured thickness of images and compared them from each equiments. Resolution has difference to size of collimation in DR FD type. Also there is no difference the original image with the new image which we abbreviated mAs. In DR CCD type, resolution didn't have difference whether lead plate is or not and whether we do collimation or not. In film type, existing or nonexisting of lead plate didn't influence on resolution. Lead plate makes the quality of image higher due to reducing scattered ray, it doesn't influence on resolution.

  • PDF

A Study for Establishment of High Dose Radioiodine Therapy Patients' Release Standard

  • Park, Hoon-Hee;Kim, Hyun-Soo;Dong, Kyung-Rae
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.13 no.4
    • /
    • pp.153-156
    • /
    • 2011
  • This study, which is proceeded in the department of nuclear medicine, aims at preventing unnecessary radiation exposure to the patients and the people near the patients by understanding and presenting the realities about the isolating period for the high dose radioiodine patients after total thyroidectomy in the 7 general hospitals in metropolitan area. Theoretically, the physical half-life of the high dose radioiodine is 8 days. Radioiodine lower than 100 mCi usually is eliminated all in 2 days 1 night considering the biological half-life and the amount of excreting radioiodine The hospitalization standard of the patients treated with high-dose radioiodine therapy has been established according to the fact above. Investigation of the data and questionnaire from the hospital have proven that some hospitals didn't even measure the acceptable dose because of the faith in the vague data. Besides, the some of those inevitably let the readmitting patients exceeding the acceptable dose be in the general ward, not in the isolation ward, because the number of the isolation rooms is relatively smaller than the patients. Thus, we want to contribute that patients understand the realities and the hospitals consider the relevant problem actively so that the problem will be settled by this journal.

  • PDF