• Title/Summary/Keyword: Radiation Measure

Search Result 809, Processing Time 0.031 seconds

Effectiveness of the ultrasonography in the evaluation following orbit wall reconstruction (안와벽 재건술 시행 후 평가방법으로서 초음파의 효용성)

  • Kim, Chang Yun;Yang, Jeong Yeol;Cheon, Ji Seon;Moon, Jae won
    • Archives of Plastic Surgery
    • /
    • v.36 no.4
    • /
    • pp.428-431
    • /
    • 2009
  • Purpose: Blow out fracture resulting from facial trauma is of high frequency among facial bone fractures, and can cause severe complications. So, proper management and close observation after operation are needed. So far, Computed tomography has been the best choice in the evalution following orbit wall reconstruction. However, cost - effectiveness, accessibility to patients and hazard of radiation exposure of computed tomography require supplementary measure for the evaluation following orbit wall reconstruction. This study was performed to describe the effectiveness of ultrasonography in the evalution following orbit wall reconstruction. Methods: A retrospective study was performed on 40 patients who underwent orbit wall reconstruction from June, 2008 to July, 2008. The patients' ages ranged from 13 to 65 years (mean 27.5 years), and this group was compsoed of 27 male and 13 female patients. The follow up period ranged from 2 weeks to 28 weeks (mean 11weeks). Preoperatively, all fractures were diagnosed using computed tomography. Ultrasonography for all cases, and computed tomography for 2 cases were performed for evaluation following orbit wall reconstruction. Results: Reduction of herniated orbital soft tissue and orbit implant was identified by using ultrasonography in 38 cases out of 40 cases. In other cases which we could not identify the orbit implant, computed tomography was performed. Con clusion: Compared to computed tomography, ultrasonography is simple, inexpensive and convenient method. Ultrasonography can be used as supplementary measure to computed tomography in the evaluation following orbit wall reconstruction for elective patients.

Study on dose and image quality by Added filter and Grid change when exam abdominal fluoroscopy (복부투시조영 검사 시 Added filter와 Grid 변화에 따른 선량 및 화질에 관한 연구)

  • Hong, Seon Sook;Kang, Kyeong Mi;Seong, Min Suk;Lee, Jong Woong
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.14 no.2
    • /
    • pp.47-56
    • /
    • 2012
  • Amount of radiation exposure by seeing through fluoroscopy examination while is many patient exposure administration and unprepared misgovernment be. In this study, abdominal fluoroscopy during the scan, the dose and image quality change according to the use of grid and added filter optimized by measuring the test condition is proposed. Uses seeing through fluoroscopy examination equipment of Image Intensifier of Easy Diagnost Eleva (Philips), under tube type and uses Human phantom and measures average area dose according to grid insertion existence and nonexistence and added filter kind change. Measure sum of 29 organ dose and effective dose through PCXMC imagination simulation program and image J program through noise, SNR, image distortion was measured. Resolution, sharpness, and analyzed using the MTF curves. Fluorography the grid to insert the filter thickness and thickening and increased the average area dose and organ doses and effective dose. In the case of spot examination, when inserted grid, average area dose and organ dose and effective dose increased. Filter thickens the average area dose decreased, but the organ doses and effective dose were increased when use 0.2mmCu+1mmAl filter, decreased slightly. Noise and SNR measurements without inserting the gird, if you do not use the added filter was the lowest and when measure the distortion, 0.1mmCu+1mmAl filter was no difference of image quality in case insert grid was judged that when did not use occasion added filter that do not use grid, difference of image quality does not exist. Did not show a big difference, according to the grid and uses of the added filter sharpness, and resolution. Patient dose increases with factors that reduce the quality of the image so reckless grid and the use of the added filter when abdominal fluoroscopy examination should be cautious in using.

  • PDF

A Study on the Fire Risk of High-voltage Cables for Electrical Vehicles (전기차용 고전압 케이블의 화재 위험성에 관한 연구)

  • Sin Dong Kang;Ye Jin Park;Si Hyun Kim;Jae-Ho Kim
    • Journal of the Korean Society of Safety
    • /
    • v.38 no.4
    • /
    • pp.8-14
    • /
    • 2023
  • This study presents the characteristics of short circuits (SCs) caused by excessive currents in high-voltage cables used in electric vehicles and emphasizes the need to calculate the cross-sectional areas of these cables according to the SC current. Three direct current power supplies were connected in parallel to test the SC characteristics caused by excessive currents, and a timer and a magnetic contactor were used to deliver the conduction time and SC current. A circular infrared-radiation heater was used to test the temperature-dependent SC characteristics, a thermocouple was used to measure the temperature, and a shunt resistor was used to measure the current. As the SC current increased, the fusing time of the cable decreased. Additionally, a high-voltage cable (with an area of 16 mm2 ) used in electric vehicles fused when a current (approximately equal to 55 times the allowable current) flowed for 0.2 s (operating time of the protective device). When the SC current is 10 kA, the cable may fuse during the operating time of the protective device, thus creating a fire hazard. In electric vehicles, the size of the SC current increases in proportion to the capacity of the battery. Thus, the cross-sectional areas of the cables used should be calculated accordingly, and cable operations should be properly coordinated with the surrounding protective devices.

Evaluation of Usability Both Oblique Verification for Inserted Fiducial Marker of Prostate Cancer Patients (Fiducial Marker가 삽입된 전립선암 환자를 대상으로 한 양사방향 촬영의 유용성 평가)

  • Kim, Koon Joo;Lee, Jung Jin;Kim, Sung Gi;Lim, Hyun Sil;Kim, Wan Sun;Kang, Su Man
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.2
    • /
    • pp.123-129
    • /
    • 2013
  • Purpose: The way check the movement of the fiducial marker insertion in the treatment of patients with prostate cancer. However the existing methods of fiducial marker verification process difficult to identify the specific location of the marker behind the femur and pelvic bone. So to study the evaluation of maker match with using kilo voltage (KV) X-ray by On-board imager to both oblique verification method. Materials and Methods: Five patients were selected for rectal ballooning and inserted fiducial marker. Compare the position of the fiducial marker of reference plan 2D/2D Anterior/Posterior verification method and 2D/2D both oblique verification method. So to measurement the shift score of X, Y, Z (axis) and measure exposure dose given to patients and compare matching time. Results: 2 dimensional OBI KV X-ray imaging using two-dimensional matching image are orthogonal, so locating fiducial marker matching clear and useful DRR (digital reconstruction radiography) OBI souce angle ($45^{\circ}/315^{\circ}$) matching most useful. 2D/2D both oblique verification method was able to see clearly marker behind the pelvic bone. Also matching time can be reduced accordingly. According to the method of each matching results for each patient in each treatment fraction, X, Y, and Z axis the Mean $value{\pm}SD$ (standard deviation) is X axis (AP/LAT: $0.4{\pm}1.67$, OBLIQUE: $0.4{\pm}1.82$) mm, Y axis (AP/LAT: $0.7{\pm}1.73$, OBLIQUE: $0.2{\pm}1.77$) mm, Z axis (AP/LAT: $0.8{\pm}1.94$, OBLIQUE:$1.5{\pm}2.8$) mm. In addition, the KV X-ray source dose radiation exposure given to the patient taking average when AP/LAT matching is (0.1/2.1) cGY, when $315^{\circ}/45^{\circ}$ matching is (0.27/0.26) cGY. Conclusion: In conclusion for inserted fiducial marker of prostate cancer patients 2D/2D both oblique matching method is more accurate verification than 2D/2D AP/LAT matching method. Also the matching time less than the 2D/2D AP/LAT matching method. Taken as the amount of radiation exposure to patients less than was possible. Suggest would improve the treatment quality of care patients more useful to establish a protocol such as case.

  • PDF

The Study of Shielding Effect on Ovoids of Three Different Gynecological Applicator Sets in microSelectron-HDR System (microSelectron-HDR System에서 부인암 강내조사에 쓰이는 세 가지 Applicator Set들의 Ovoids에 대한 차폐효과 연구)

  • Cho, Young-K.;Park, Sung-Y.;Choi, Jin-H.;Kim, Hung-J.;Kim, Woo-C.;Loh, John-J.K.;Kim, Joo-Y.
    • Journal of Radiation Protection and Research
    • /
    • v.23 no.4
    • /
    • pp.259-266
    • /
    • 1998
  • There are three different types of gynecological applicator sets available in microSelectron-high dose-rate(HDR) System by Nucletron; standard applicator set(SAS), standard shielded applicator set(SSAS), and Fletcher-Williamson applicator set(FWAS). Shielding effect of a SAS without shielding material was compared with that of a SSAS with shielding material made of stainless steel(density ${\varrho}=8,000kg/m^3$) at the top and bottom of each ovoid, and of a FWAS with shielding material made of tungsten alloy(density ${\varrho}=14,000kg/m^3$ at the top and bottom of each ovoid. The shielding effects to the rectum and bladder of these two shielded applicator sets were to be measured at reference points with an ion chamber and specially designed supporting system for applicator ovoids inside of the computerized 3-dimensional water phantom. To determine the middle point of two ovoids the measurement was performed with the reference tip of ion chamber placed at the same level and at the middle point from the two ovoids, while scanning the dose with the ion chamber on each side of ovoids. The doses to the reference points of rectum were measured at 20(Rl), 25(R2), 30(R3), 40(R4), 50(R5), and 60(R6) mm located posteriorly on the vertical line drawn from M5(the middle dwell position of ovoid), and the doses to the bladder were measured at 20(Bl), 30(B2), 40(B3), 50(B4), and 60(B5) mm located anteriorly on the vertical line drawn from M5. The same technique was employed to measure the doses on each reference point of both SSAS and FWAS. The differences of measured rectal doses at 25 mm(R2) and 30 mm(R3) between SAS and SSAS were 8.0 % and 6.0 %: 25.0% and 23.0 % between SAS and FWAS. The differences of measured bladder doses at 20 mm(Bl) and 30 mm(B2) between SAS and SSAS were 8.0 % and 3.0 %: 23.0 % and 17.0 % between SAS and FWAS. The maximum shielding effects to the rectum and bladder of SSAS were 8.0 % and 8.0 %, whereas those of FWAS were 26.0 % and 23.0 %, respectively. These results led to the conclusion that FWAS has much better shielding effect than SSAS does, and when SSAS and FWAS were used for gynecological intracavitary brachytherapy in microSelectron-HDR system, the dose to the rectum and bladder was significantly reduced to optimize the treatment outcome and to lower the complication rates in the rectum and bladder.

  • PDF

Evaluation of usefulness of the Gated Cone-beam CT in Respiratory Gated SBRT (호흡동조 정위체부방사선치료에서 Gated Cone-beam CT의 유용성 평가)

  • Hong sung yun;Lee chung hwan;Park je wan;Song heung kwon;Yoon in ha
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.34
    • /
    • pp.61-72
    • /
    • 2022
  • Purpose: Conventional CBCT(Cone-beam Computed-tomography) caused an error in the target volume due to organ movement in the area affected by respiratory movement. The purpose of this paper is to evaluate the usefulness of accuracy and time spent using the Gated CBCT function, which reduces errors when performing RGRT(respiratory gated radiation therapy), and to examine the appropriateness of phase. Materials and methods: To evaluate the usefulness of Gated CBCT, the QUASARTM respiratory motion phantom was used in the Truebeam STxTM. Using lead marker inserts, Gated CBCT was scaned 5 times for every 20~80% phase, 30~70% phase, and 40~60% phase to measure the blurring length of the lead marker, and the distance the lead marker moves from the top phase to the end of the phase was measured 5 times. Using Cedar Solid Tumor Inserts, 4DCT was scanned for every phase, 20-80%, 30-70%, and 40-60%, and the target volume was contoured and the length was measured five times in the axial direction (S-I direction). Result: In Gated CBCT scaned using lead marker inserts, the axial moving distance of the lead marker on average was measured to be 4.46cm in the full phase, 3.11cm in the 20-80% phase, 1.94cm in the 30-70% phase, 0.90cm in the 40-60% phase. In Fluoroscopy, the axial moving distance of the lead marker on average was 4.38cm and the distance on average from the top phase to the beam off phase was 3.342cm in the 20-80% phase, 3.342cm in the 30-70% phase, and 0.84cm in the 40-60% phase. Comparing the results, the difference in the full phase was 0.08cm, the 20~80% phase was 0.23cm, the 30~70% phase was 0.10cm, and the 40~60% phase was 0.07cm. The axial lengths of ITV(Internal Target Volume) and PTV(Planning Target Volume) contoured by 4DCT taken using cedar solid tumor inserts were measured to be 6.40cm and 7.40cm in the full phase, 4.96cm and 5.96cm in the 20~80% phase, 4.42cm and 5.42cm in the 30~70% phase, and 2.95cm and 3.95cm in the 40~60% phase. In the Gated CBCT, the axial lengths on average was measured to be 6.35 cm in the full phase, 5.25 cm in the 20-80% phase, 4.04 cm in the 30-70% phase, and 3.08 cm in the 40-60% phase. Comparing the results, it was confirmed that the error was within ±8.5% of ITV Conclusion: Conventional CBCT had a problem that errors occurred due to organ movement in areas affected by respiratory movement, but through this study, obtained an image similar to the target volume of the setting phase using Gated CBCT and verified its usefulness. However, as the setting phase decreases, the scan time was increases. Therefore, considering the scan time and the error in setting phase, It is recommended to apply it to patients with respiratory coordinated stereotactic radiation therapy using a wide phase of 30-70% or more.

Development of New 4D Phantom Model in Respiratory Gated Volumetric Modulated Arc Therapy for Lung SBRT (폐암 SBRT에서 호흡동조 VMAT의 정확성 분석을 위한 새로운 4D 팬텀 모델 개발)

  • Yoon, KyoungJun;Kwak, JungWon;Cho, ByungChul;Song, SiYeol;Lee, SangWook;Ahn, SeungDo;Nam, SangHee
    • Progress in Medical Physics
    • /
    • v.25 no.2
    • /
    • pp.100-109
    • /
    • 2014
  • In stereotactic body radiotherapy (SBRT), the accurate location of treatment sites should be guaranteed from the respiratory motions of patients. Lots of studies on this topic have been conducted. In this letter, a new verification method simulating the real respiratory motion of heterogenous treatment regions was proposed to investigate the accuracy of lung SBRT for Volumetric Modulated Arc Therapy. Based on the CT images of lung cancer patients, lung phantoms were fabricated to equip in $QUASAR^{TM}$ respiratory moving phantom using 3D printer. The phantom was bisected in order to measure 2D dose distributions by the insertion of EBT3 film. To ensure the dose calculation accuracy in heterogeneous condition, The homogeneous plastic phantom were also utilized. Two dose algorithms; Analytical Anisotropic Algorithm (AAA) and AcurosXB (AXB) were applied in plan dose calculation processes. In order to evaluate the accuracy of treatments under respiratory motion, we analyzed the gamma index between the plan dose and film dose measured under various moving conditions; static and moving target with or without gating. The CT number of GTV region was 78 HU for real patient and 92 HU for the homemade lung phantom. The gamma pass rates with 3%/3 mm criteria between the plan dose calculated by AAA algorithm and the film doses measured in heterogeneous lung phantom under gated and no gated beam delivery with respiratory motion were 88% and 78%. In static case, 95% of gamma pass rate was presented. In the all cases of homogeneous phantom, the gamma pass rates were more than 99%. Applied AcurosXB algorithm, for heterogeneous phantom, more than 98% and for homogeneous phantom, more than 99% of gamma pass rates were achieved. Since the respiratory amplitude was relatively small and the breath pattern had the longer exhale phase than inhale, the gamma pass rates in 3%/3 mm criteria didn't make any significant difference for various motion conditions. In this study, the new phantom model of 4D dose distribution verification using patient-specific lung phantoms moving in real breathing patterns was successfully implemented. It was also evaluated that the model provides the capability to verify dose distributions delivered in the more realistic condition and also the accuracy of dose calculation.

The Availability of the step optimization in Monaco Planning system (모나코 치료계획 시스템에서 단계적 최적화 조건 실현의 유용성)

  • Kim, Dae Sup
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.207-216
    • /
    • 2014
  • Purpose : We present a method to reduce this gap and complete the treatment plan, to be made by the re-optimization is performed in the same conditions as the initial treatment plan different from Monaco treatment planning system. Materials and Methods : The optimization is carried in two steps when performing the inverse calculation for volumetric modulated radiation therapy or intensity modulated radiation therapy in Monaco treatment planning system. This study was the first plan with a complete optimization in two steps by performing all of the treatment plan, without changing the optimized condition from Step 1 to Step 2, a typical sequential optimization performed. At this time, the experiment was carried out with a pencil beam and Monte Carlo algorithm is applied In step 2. We compared initial plan and re-optimized plan with the same optimized conditions. And then evaluated the planning dose by measurement. When performing a re-optimization for the initial treatment plan, the second plan applied the step optimization. Results : When the common optimization again carried out in the same conditions in the initial treatment plan was completed, the result is not the same. From a comparison of the treatment planning system, similar to the dose-volume the histogram showed a similar trend, but exhibit different values that do not satisfy the conditions best optimized dose, dose homogeneity and dose limits. Also showed more than 20% different in comparison dosimetry. If different dose algorithms, this measure is not the same out. Conclusion : The process of performing a number of trial and error, and you get to the ultimate goal of treatment planning optimization process. If carried out to optimize the completion of the initial trust only the treatment plan, we could be made of another treatment plan. The similar treatment plan could not satisfy to optimization results. When you perform re-optimization process, you will need to apply the step optimized conditions, making sure the dose distribution through the optimization process.

Evaluate the Change of Body Shape and the Patient Alignment State During Image-Guided Volumetric Modulated Arc Therapy in Head and Neck Cancer Patients (두경부 환자의 VMAT 시 체형변화와 환자 정렬과의 상관관계 고찰)

  • Seo, Se Jeong;Kim, Tae Woo;Choi, Min Ho;Son, Jong Gi
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.2
    • /
    • pp.109-117
    • /
    • 2017
  • Objectives: The purpose of this study was to evaluate the change of body shape and the patient alignment state during image-guided volumetric modulated arc therapy in head and neck cancer patients, Materials and Methods: We performed a image-guided volumetric modulated arc therapy plan for 89 patients with head and neck cancer who underwent curative radiotherapy. Ten of them were evaluated for set up error. The landmarks of the ramus, chin, posterior neck, and clavicle were specified using ARIA software (Offline review), and the positional difference was analyzed. Results: The re-CT simulation therapy was performed in 60 men with $17{\pm}4$ cycles of treatment. The weight loss rate was $-6.47{\pm}3.5%$. 29 women performed re-CT simulation at $17{\pm}5$ cycles As a result, weight loss rate was $-5.73{\pm}2.7%$. The distance from skin to C1, C3, and C5 was measured, and both clavicle levels were observed to measure the skin shrinkage changes. The skin shrinkage standard deviations were C1 (${\pm}0.44cm$), C3 (${\pm}0.83cm$), and C5 (${\pm}1.35cm$), which is about 1 mm shrinkage per 0.5 kg reduction. Skin shrinkage according to the number of treatments was 1 ~ 4 fractions (no change), 5 ~ 13 fractions (-2 mm), 14 ~ 22 fractions (-4 mm) and 23 ~ 30 fractions (-6 mm). Conclusion: When the body shape changes about 5 mm, the central dose starts to differ about 3 % or more. Therefore, the CT simulation treatment for the adaptive therapy should be additionally performed. In addition, it is necessary to actively study the CT simulation therapy method and set up method of the lower neck and to examine the use of a new immobilization device.

  • PDF

Studies on the Use of Radioisotope Tracer Technique to Investigate and Improve the Root Activities in Rice Plant (II) - Effect of Application of Several Kinds of Phosphorous Fertilizer - (방사성동위체(放射性同位體) 도입(導入)과 그 추적기술(追跡技術)에 의(依)한 수도근계(水稻根系) 활성상(活性相)의 해명(解明)과 개선(改善)에 관(關)한 연구(硏究) - 인산질(燐酸質) 비료(肥料)의 비종별(肥種別) 시용효과(施用效果)에 대(對)하여 - (제2보)(第2報))

  • Ahn, Hak-Soo;Chung, Hee-Don;Ahn, Jon-Sung;Ro, Jun-Chong;Kim, Kyu-Won;Shim, Sang-Chil
    • Applied Biological Chemistry
    • /
    • v.15 no.1
    • /
    • pp.85-92
    • /
    • 1972
  • The field experiment was performed to investigate the effects of various kinds of phosphorus fertilizers such as double superphosphate, fused magnesium phosphate and Simagcarin (both the Kyun-gi Chemical Co, products) on the physiological roles in development of root system, growth and yield compositions of rice plant. Radioactive phosphoric acid $(H_3\;^{32}PO_4)$ was applied to measure the root activity. 1. The number of total tillers was significantly increased in double superphosphate plots, but the rate of fruitful tillers was more numerous in the fused magnesium phosphate and the Simagcarin plots than that of the other plots. 2. The grain yield was much more obtained in the fused magnesium phosphate and Simagcarin plots (no significant difference were found between both of plots) than the double superphosphate and control plots. It seemed due to the increasing of seedbearing rate and number of fruitful tillers. 3. In double superphosphate plots, root system was mostly developed near topsoil areas, but fused magnesium phosphate and the Simagcarin plots, root system was uniformly distributed from topsoil to subsoil areas. 4. As the results of those experiments, fused magnesium phosphate and Simagcarin was demonstrated to be soil amendmentical materials rather than the phosphorus fertilizers, especially in low productive paddy soils which lack the special mineral nutritions.

  • PDF