Acceptance Testing and Commissioning of Robotic Intensity-Modulated Radiation Therapy M6 System Equipped with InCiseTM2 Multileaf Collimator

  • Yoon, Jeongmin;Park, Kwangwoo;Kim, Jin Sung;Kim, Yong Bae;Lee, Ho
    • 한국의학물리학회지:의학물리
    • /
    • 제29권1호
    • /
    • pp.8-15
    • /
    • 2018
  • This work reports the acceptance testing and commissioning experience of the Robotic Intensity-Modulated Radiation Therapy (IMRT) M6 system with a newly released $InCise^{TM}2$ Multileaf Collimator (MLC) installed at the Yonsei Cancer Center. Acceptance testing included a mechanical interdigitation test, leaf positional accuracy, leakage check, and End-to-End (E2E) tests. Beam data measurements included tissue-phantom ratios (TPRs), off-center ratios (OCRs), output factors collected at 11 field sizes (the smallest field size was $7.6mm{\times}7.7mm$ and largest field size was $115.0mm{\times}100.1mm$ at 800 mm source-to-axis distance), and open beam profiles. The beam model was verified by checking patient-specific quality assurance (QA) in four fiducial-inserted phantoms, using 10 intracranial and extracranial patient plans. All measurements for acceptance testing satisfied manufacturing specifications. Mean leaf position offsets using the Garden Fence test were found to be $0.01{\pm}0.06mm$ and $0.07{\pm}0.05mm$ for X1 and X2 leaf banks, respectively. Maximum and average leaf leakages were 0.20% and 0.18%, respectively. E2E tests for five tracking modes showed 0.26 mm (6D Skull), 0.3 mm (Fiducial), 0.26 mm (Xsight Spine), 0.62 mm (Xsight Lung), and 0.6 mm (Synchrony). TPRs, OCRs, output factors, and open beams measured under various conditions agreed with composite data provided from the manufacturer to within 2%. Patient-specific QA results were evaluated in two ways. Point dose measurements with an ion chamber were all within the 5% absolute-dose agreement, and relative-dose measurements using an array ion chamber detector all satisfied the 3%/3 mm gamma criterion for more than 90% of the measurement points. The Robotic IMRT M6 system equipped with the $InCise^{TM}2$ MLC was proven to be accurate and reliable.

방사선수술용 4뱅크 마이크로 다엽콜리메이터의 인수 검사 (Commissioning of a micro-MLC (mMLC) for Stereotactic Radiosurgery)

  • 정동혁;신교철;김정기;김수곤;문성록;이강규
    • 한국의학물리학회지:의학물리
    • /
    • 제20권1호
    • /
    • pp.43-50
    • /
    • 2009
  • 본 연구에서는 방사선수술용 4뱅크 마이크로다엽콜리메이터(micro-multileaf collimator: mMLC)인 Acculeaf (Direx, Isral)의 가동을 위하여 인수 검사를 실시하였다. mMLC의 제어에 필요한 기하학적 요소들을 결정하고 선량계산 모델에 의해 계산한 결과를 절대선량(cGy/100 MU)의 측면에서 측정과 비교하였다. 고정된 SSD (source to surface distance) 및 SCD(source to chamber distance) 조건에서 다양한 조사면과 깊이 5 cm와 10 cm에 대하여 계산값을 평가한 결과 6 MV와 15MV x-선에 대하여 대부분 1.0% 이내로 일치하였다. 반음영의 크기는 조사면에 의존하면서 6 MV에 대하여 0.29~0.43cm 범위 그리고 15 MV에 대하여 0.36~0.51 cm 범위로 평가되었다. 엽의 투과 및 누설의 측정결과 단층 엽들에 대하여 평균 6.6% (6 MV) 및 7.4% (15 MV) 그리고 겹층 엽들에 대하여 평균 약 0.5% (6 and 15 MV)로 나타났다. 인수검사를 통하여 mMLC의 선량적 특성을 확인할 수 있었으며 치료계획시스템의 오차범위를 근사적으로 평가할 수 있었다.

  • PDF

Dosimetric Comparison of Three-Dimensional Conformal, Intensity-Modulated Radiotherapy, Volumetric Modulated Arc Therapy, and Dynamic Conformal Arc Therapy Techniques in Prophylactic Cranial Irradiation

  • Ismail Faruk Durmus;Dursun Esitmez;Guner Ipek Arslan;Ayse Okumus
    • 한국의학물리학회지:의학물리
    • /
    • 제34권4호
    • /
    • pp.41-47
    • /
    • 2023
  • Purpose: This study aimed to dosimetrically compare the technique of three-dimensional conformal radiotherapy (3D CRT), which is a traditional prophylactic cranial irradiation method, and the intensity-modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT) techniques used in the last few decades with the dynamic conformal arc therapy (DCAT) technique. Methods: The 3D CRT, VMAT, IMRT, and DCAT plans were prepared with 25 Gy in 10 fractions in a Monaco planning system. The target volume and the critical organ doses were compared. A comparison of the body V2, V5, and V10 doses, monitor unit (MU), and beam on-time values was also performed. Results: In planned target volume of the brain (PTVBrain), the highest D99 dose value (P<0.001) and the most homogeneous (P=0.049) dose distribution according to the heterogeneity index were obtained using the VMAT technique. In contrast, the lowest values were obtained using the 3D CRT technique in the body V2, V5, and V10 doses. The MU values were the lowest when DCAT (P=0.001) was used. These values were 0.34% (P=0.256) lower with the 3D CRT technique, 66% (P=0.001) lower with IMRT, and 72% (P=0.001) lower with VMAT. The beam on-time values were the lowest with the 3D CRT planning (P<0.001), 3.8% (P=0.008) lower than DCAT, 65% (P=0.001) lower than VMAT planning, and 76% (P=0.001) lower than IMRT planning. Conclusions: Without sacrificing the homogeneous dose distribution and the critical organ doses in IMRTs, three to four times less treatment time, less low-dose volume, less leakage radiation, and less radiation scattering could be achieved when the DCAT technique is used similar to conventional methods. In short, DCAT, which is applicable in small target volumes, can also be successfully planned in large target volumes, such as the whole-brain.

후쿠시마 원전사고 및 방사능 오염에 대한 인식조사 (An Investigation of Awareness on the Fukushima Nuclear Accident and Radioactive Contamination)

  • 하정철;송영주
    • Journal of Radiation Protection and Research
    • /
    • 제41권1호
    • /
    • pp.7-14
    • /
    • 2016
  • 연구배경: 본 연구는 일본 후쿠시마 원전사고 이후 원전사고 및 방사능 오염에 대한 우리 국민들의 인식도를 확인하기 위한 목적으로 진행되었다. 재료 및 방법: 설문조사는 수도권에 거주하는 성인 600명을 대상으로 하였다. 결과 및 논의: 연구 결과, 대다수 국민들은 일본 원전사고로 인한 방사능 누출이 우리나라에 영향을 미치고 있다고 우려하였다. 식품, 특히 수산물의 방사능 오염에 대한 우려가 높았고, 선호하는 정보 취득원은 TV(49.8%)와 인터넷 매체(31.3%)였다. 한편 다수의 국민들은 일본 원전사고 및 방사능 오염 정보가 충분히 제공되지 않았고, 원전사고 이후 우리 정부의 대응조치를 잘 모르고 있는 것으로 나타났다. 또한 국민 대다수가 식품 환경 등의 방사능 오염 정도와 안전성에 대한 정보제공 강화가 가장 중요한 것으로 인식하고 있었다. 결론: 본 연구 결과는 향후 방사능에 대한 올바른 인식 확립과 방사능 안전사고 리스크커뮤니케이션을 위한 유용한 자료로 활용될 수 있을 것으로 기대된다.

방류수의 방사능 오염 측정을 위한 배열형 SiPM 기반 방사선 검출 센서 제작 (Development of Radiation Sensor Based on Array SiPM for Measurement of Radioactive Contamination in Effluent)

  • 김정호;박혜민;주관식
    • 센서학회지
    • /
    • 제27권4호
    • /
    • pp.232-236
    • /
    • 2018
  • A radiation detection sensor was developed and characterized by combining three types of CsI(Tl) scintillators and an array-type SiPM to detect the radioactive contamination of discharged water in real time. The characterization results showed that type 3 exhibited the most desirable characteristics in response linearity (R-square: 0.97889) according to detection sensitivity and incident radiation dose. Furthermore, in terms of spectral characteristics, type 3 exhibited 16.54% at 0.356 MeV (the emission gamma ray energy of $^{133}Ba$), 10.28% at 0.511 MeV (the emission gamma ray energy of $^{22}Na$), 9.68% at 0.356 MeV (the emission gamma ray energy of $^{137}Cs$), and 2.55% and 4.80% at 1.173 MeV and 1.332 MeV (the emission gamma ray energies of $^{60}Co$), respectively. These measurements confirmed the good energy characteristics. The results were used to evaluate the spectral characteristics and energy linearity in a mixed source using type 3 with the best detection characteristics. It was confirmed that the gamma ray peaks of $^{133}Ba$, $^{22}Na$, $^{137}Cs$, and $^{60}Co$ were well resolved. Moreover, it was confirmed that R-square, which is an indicator of energy linearity, was 0.99986. This indicates a good linearity characteristic. Based on this study, further commercialization studies will contribute to measurements in real time and to the management of the contamination caused by radioactive wastewater or radioactive material leakage, which originate from facilities that use radioactive isotopes or care facilities.

후방복사를 이용한 램파의 위상속도 분산과 군속도의 측정 (Determination of Phase Velocity Dispersion Curve and Group Velocity of lamb Waves Using Backward Radiation)

  • 송성진;권성덕;정용무;김영환
    • 한국음향학회지
    • /
    • 제22권1호
    • /
    • pp.61-68
    • /
    • 2003
  • 유도초음파는 얇은 판재와 다층재료를 평가하는데 널리 사용되는데, 이를 정량적으로 이용하기 위해서는 위상 및 군속도의 분산 곡선은 필수적이다. 본 연구에서는 누수 램파의 후방복사 신호를 측정하기 위한 측정장치를 개발하였다. 시험편을 회전시켜서 입사각을 변화시켰으며, 2차원 평면에서 움직이면서 입사 위치를 바꾸었다. 광대역 초음파 탐촉자를 사용하여 탄성판에서 발생하는 누수 램파 후방복사 신호를 측정하였다. 입사각으로부터 위상속도가 결정되며, 이에 해당하는 램파의 특정모드가 판재 내에 강하게 발생되고, 이 램파는 시험편의 앞뒤로 진행하면서 물속으로 에너지를 방출한다. 동일한 탐촉자를 사용하여 누수 램파의 후방복사 신호를 검출하고, 이 신호의 주파수 성분은 분산곡선에 대한 정보를 지닌다. 입사각도와 수신된 파형의 주파수 분석을 통하여 램파의 위상속도 분산곡선을 구하였다. 또한 특정한 입사각에서 입사점을 변화시키면서 초음파 신호의 시간대역 이동으로부터 군속도를 측정하였다.

유전체로 코팅된 유한한 두께의 주기 슬롯을 갖는 평행평판 도파관으로부터 누설파 복사 : H-편파 (Leaky Wave Radiation from Dielectric-Coated Parallel-Plate Waveguied Periodic Slot with Finite Thickness : H-polarization)

  • 김중표;이창원;손현
    • 한국전자파학회논문지
    • /
    • 제10권2호
    • /
    • pp.247-256
    • /
    • 1999
  • 유전체 코팅된 유한한 두께의 주기적인 슬롯을 갖는 명행명판 도파관으로부터 누설파 안테나를 H-편파 경 우에 대하여 해석하였다. 이러한 구조에 대해 슬롯영역의 전자계는 명행평판 도파관의 TM 모드의 합으로 전 개하고 그 외의 모든 영역의 전자계는 역퓨리에 변환을 이용하여 파수영역 형태로 표현되어진다. 경계조건을 적용하여 선형동차 방정식을 유도한다. 슬롯 폭과 슬롯 두께, 유전체층 두께, 슬롯 개수의 영향이 위상 상수. 누설 상수 및 복사패턴 등과 같은 복사 특성에 미치는 영향을 조사하였다. 유한한 슬롯 개수의 결과와 무한 구조의 결과와 비교하여 잘 일치함을 확인하였다.

  • PDF

Air Leakage Analysis of Research Reactor HANARO Building in Typhoon Condition for the Nuclear Emergency Preparedness

  • Lee, Goanyup;Lee, Haecho;Kim, Bongseok;Kim, Jongsoo;Choi, Pyungkyu
    • Journal of Radiation Protection and Research
    • /
    • 제41권4호
    • /
    • pp.354-358
    • /
    • 2016
  • Background: To find out the leak characteristic of research reactor 'HANARO' building in a typhoon condition Materials and Methods: MELCOR code which normally is used to simulate severe accident behavior in a nuclear power plant was used to simulate the leak rate of air and fission products from reactor hall after the shutdown of the ventilation system of HANARO reactor building. For the simulation, HANARO building was designed by MELCOR code and typhoon condition passed through Daejeon in 2012 was applied. Results and Discussion: It was found that the leak rate is $0.1%{\cdot}day^{-1}$ of air, $0.004%{\cdot}day^{-1}$ of noble gas and $3.7{\times}10^{-5}%{\cdot}day^{-1}$ of aerosol during typhoon passing. The air leak rate of $0.1%{\cdot}day^{-1}$ can be converted into $1.36m^3{\cdot}hr^{-1}$, but the design leak rate in HANARO safety analysis report was considered as $600m^3{\cdot}hr^{-1}$ under the condition of $20m{\cdot}sec^{-1}$ wind speed outside of the building by typhoon. Conclusion: Most of fission products during the maximum hypothesis accident at HANARO reactor will be contained in the reactor hall, so the direct radiation by remained fission products in the reactor hall will be the most important factor in designing emergency preparedness for HANARO reactor.

우리나라의 원자력 연구 개발에 수반된 방사선 사고 (A Summary of Radiation Accidents in Atomic Energy Activities of Korea)

  • 이현덕;하정우
    • Nuclear Engineering and Technology
    • /
    • 제2권2호
    • /
    • pp.97-106
    • /
    • 1970
  • 원자력연구, 개발, 응용 및 이용사업이 시작된지 10년이 된 오늘날, 방사선을 포함한 오염사고등이 수많이 일어났고(Tablet 참조) 이들 방사선 사고로 인하여 인체 및 시설, 기구등에 까지도 자그마한 피해나마 장해 및 손상을 주었을 것이다. 이들 방사선 사고 가운데 비교적 주요한 4건의 방사선 피폭을 포함한 신체오염 사고, 말하자면 1) Cobalt-60 gamma선으로 부터의 전신피폭사고 (130 rem), 2) iodine-131에 의한 실험실내의 표면오염사고(13 mrad/hr), 3) 기체상의 iodine-131로 인한 전신오염 사고(흡입때문에 갑상선에 집적된 방사능량: 0.36$\mu$Ci) 4) 치료용 Radium 선원의 누출로 인한 Capsule이 텅빈사고[3 mg(\ulcorner)], 등에 대하여 발견하는 즉시 최대의 노력과 최소의 비용으로써 조사, 측정하고 아울러 사고의 확대를 줄이기 위하여 가능한 모든 조처를 취하였으며, 사고의 요인분석, 평가를 하였다.

  • PDF

스테레오 감마선 탐지장치를 이용한 감마선원 분포측정 시스템에 관한 연구 (The Study Image Aquisition System for Radiation Source Using the Stereo Gamma-ray Detector)

  • 황영관;이남호;이승민
    • 전자공학회논문지
    • /
    • 제52권4호
    • /
    • pp.197-203
    • /
    • 2015
  • 전 세계적으로 전력생산을 위해 원전 증설이 지속적으로 증가하고 있으며 이에 따라 노후 원전에 대한 해체 및 원전사고에 대한 관심이 증가하고 있다. 원전 사고 시 발생되는 감마선원의 누출은 신속하고 정확한 탐지해야 그 피해를 최소화 시킬 수 있다. 기 개발된 장비는 선원에 대한 방향정보만을 나타내고 있어 정확한 공간상의 분포를 알 수 없다. 본 논문에서 개발한 스테레오 감마선탐지장치는 누출된 감마선원에 대한 분포를 측정할 수 있도록 구현하고 거리탐지를 위한 알고리즘을 적용하였다. 거리탐지를 위하여 스테레오 보정을 LED광과 보정패턴을 사용하여 진행하였고, LED 광원과 감마선원을 대상으로 성능시험을 진행하였다. 성능시험 결과 두 실험에서 5%이하의 오차를 갖게 됨을 확인하였다. 본 논문의 결과는 향후 고속 경량화 된 감마선 영상화 장치 개발을 위한 자료로 활용될 것이다.