• Title/Summary/Keyword: Radiation Exposure Dose

Search Result 1,111, Processing Time 0.025 seconds

Atmospheric Dispersion Assessment for Potential Accidental Releases at Yonggwang Nuclear Power Plants (영광원전에서 가상 사고시 대기확산 평가)

  • Na, Man-Gyun;Sim, Young-Rok;Jung, Chul-Kee;Lee, Goung-Jin;Kim, Soong-Pyung;Chung, Sung-Tai
    • Journal of Radiation Protection and Research
    • /
    • v.25 no.2
    • /
    • pp.81-87
    • /
    • 2000
  • XOQ_DW code is currently used to assess the atmospheric dispersion fur the routine releases of radioactive gaseous effluents at Yonggwang nuclear power plants. This code was developed based on XOQDOQ code and an additional code is required to assess the atmospheric dispersion for potential accidental releases. In order to assess the atmospheric dispersion fer the accidental releases, XOQAR code has been developed by using PAVAN code that is based on Reg. Guide 1.145. The terrain data of XOQ_DW code inputs and the relative concentrations (X/Q) of XOQ_DW code outputs are used as the inputs of the XOQAR code through the interface with XOQ_DW code. By using this code, the maximum values of X/Q at exclusion area and low population zone boundaries except for sea areas were assessed as $1.33{\times}10^{-4}$ and $7.66{\times}10^{-6}$ sec/$m^3$, respectively. Through the development of this code, a rode system is prepared for assessing the atmospheric dispersion for the accidental releases as well as the routine releases. This developed code ran be used for other domestic nuclear power plants by modifying the terrain input data.

  • PDF

Evaluation of Phototoxicity for Cosmetics and Alternative Method (화장품 광독성 평가와 동물대체시험법)

  • Lee, Jong-Kwon;Sin, Ji-Soon;Kim, Jin-Ho;Eom, Jun-Ho;Kim, Hyung-Soo;Park, Kui-Lea
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.31 no.3 s.52
    • /
    • pp.245-251
    • /
    • 2005
  • Safety is one of the key issue in the regulation of cosmetics. Cosmetic Act deals with it in Korea. The guidance for the testing cosmetic ingredients and their safety evaluation are prepared by Korea Food and Drug Administration. Ultraviolet radiation could Induce skin damage, edema, erythema, photoaging, immune dysfunction and skin cancer. Ultraviolet radiation is classified as Group 2A(probably carcinogenic to humans) by International Agenry for Reaserch on Cancer(IARC). The in vitro methodologies for evaluating the toxic potential of ingredients reported in the literature have not yet been sufficiently validated for use in areas other than the study for mutagenicity/genotoxicity, for pre-screening for severe irritancy, for screening of phototoxicity and for evaluating the percutaneous absorption. The 3T3 neutral red uptake photoxicity test (3T3 NRU PT) was accepted as OECD toxicity guideline in 2002. The 3T3 NRU PT is an in vitro method based on a comparison of the cytotoxicitv of a chemical when tested in the presence and in the absence of exposure to a non-cytotoxic dose of UVA/visible light.

Use of Coronary CT Angiography as a Screening Tool for Coronary Artery Disease in Asymptomatic Healthy Individuals or Patients (무증상 정상인 또는 환자의 관상동맥 질환 선별 검사로서 관상동맥 전산화단층촬영 혈관조영술의 유용성)

  • Gong Yong Jin
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.1
    • /
    • pp.54-69
    • /
    • 2022
  • Early detection of potential asymptomatic coronary artery disease is very important, as patients with sudden cardiac death often do not show symptoms such as chest pain or motor dyspnea. Coronary CT angiography (CCTA) has long been unjustified as a screening tool for asymptomatic patients because of the risks posed by radiation exposure. However, there are still various opinions regarding the usefulness of CCTA for screening for coronary artery disease (CAD) in asymptomatic healthy individuals or patients. This review investigated the usefulness of coronary artery calcium score and CCTA as screening tests for CAD in asymptomatic healthy individuals or patients through various literature reviews. With the development of CT technology, recent studies have been conducted in asymptomatic CAD patients with a reduced radiation dose of less than 1 mSv. A total of 2.6% of asymptomatic subjects on CCTA found significant CAD over 70%, and it was concluded that screening CCTA for CAD showed prognostic power in predicting the future occurrence of CAD in asymptomatic people. However, after the completion of the current NIH SCOT-HEART 2 study, it may be possible to determine whether CCTA is appropriate as a screening tool for CAD in asymptomatic healthy individuals.

An Efficient CT Image Denoising using WT-GAN Model

  • Hae Chan Jeong;Dong Hoon Lim
    • Journal of the Korea Society of Computer and Information
    • /
    • v.29 no.5
    • /
    • pp.21-29
    • /
    • 2024
  • Reducing the radiation dose during CT scanning can lower the risk of radiation exposure, but not only does the image resolution significantly deteriorate, but the effectiveness of diagnosis is reduced due to the generation of noise. Therefore, noise removal from CT images is a very important and essential processing process in the image restoration. Until now, there are limitations in removing only the noise by separating the noise and the original signal in the image area. In this paper, we aim to effectively remove noise from CT images using the wavelet transform-based GAN model, that is, the WT-GAN model in the frequency domain. The GAN model used here generates images with noise removed through a U-Net structured generator and a PatchGAN structured discriminator. To evaluate the performance of the WT-GAN model proposed in this paper, experiments were conducted on CT images damaged by various noises, namely Gaussian noise, Poisson noise, and speckle noise. As a result of the performance experiment, the WT-GAN model is better than the traditional filter, that is, the BM3D filter, as well as the existing deep learning models, such as DnCNN, CDAE model, and U-Net GAN model, in qualitative and quantitative measures, that is, PSNR (Peak Signal-to-Noise Ratio) and SSIM (Structural Similarity Index Measure) showed excellent results.

3DentAI: U-Nets for 3D Oral Structure Reconstruction from Panoramic X-rays (3DentAI: 파노라마 X-ray로부터 3차원 구강구조 복원을 위한 U-Nets)

  • Anusree P.Sunilkumar;Seong Yong Moon;Wonsang You
    • The Transactions of the Korea Information Processing Society
    • /
    • v.13 no.7
    • /
    • pp.326-334
    • /
    • 2024
  • Extra-oral imaging techniques such as Panoramic X-rays (PXs) and Cone Beam Computed Tomography (CBCT) are the most preferred imaging modalities in dental clinics owing to its patient convenience during imaging as well as their ability to visualize entire teeth information. PXs are preferred for routine clinical treatments and CBCTs for complex surgeries and implant treatments. However, PXs are limited by the lack of third dimensional spatial information whereas CBCTs inflict high radiation exposure to patient. When a PX is already available, it is beneficial to reconstruct the 3D oral structure from the PX to avoid further expenses and radiation dose. In this paper, we propose 3DentAI - an U-Net based deep learning framework for 3D reconstruction of oral structure from a PX image. Our framework consists of three module - a reconstruction module based on attention U-Net for estimating depth from a PX image, a realignment module for aligning the predicted flattened volume to the shape of jaw using a predefined focal trough and ray data, and lastly a refinement module based on 3D U-Net for interpolating the missing information to obtain a smooth representation of oral cavity. Synthetic PXs obtained from CBCT by ray tracing and rendering were used to train the networks without the need of paired PX and CBCT datasets. Our method, trained and tested on a diverse datasets of 600 patients, achieved superior performance to GAN-based models even with low computational complexity.

Uncertainty Management on Human Intrusion Scenario Assessment of the Near Surface Disposal Facility for Low and Intermediate-Level Radioactive Waste: Comparative Analysis of RESRAD and GENII (중저준위방사성폐기물 표층처분시설의 인간침입 시나리오 평가에 대한 불확실성 관리: RESRAD와 GENII의 비교분석)

  • Kim, Minseong;Hong, Sung-Wook;Park, Jin Beak
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.15 no.4
    • /
    • pp.369-380
    • /
    • 2017
  • In order to manage the uncertainty about the evaluation and analysis of the human intrusion scenario of the Gyeongju Low and Intermediate Level Radioactive Waste(LILW) disposal facility, the calculation result by the GENII code was assessed using the RESRAD code, which was developed to evaluate the radiation effects of contaminated soil. The post-drilling scenario was selected as a human intrusion scenario into the near-surface disposal facility to analyze the uncertainty of the modeling by identifying any limitations in the simulation of each code and comparing the evaluation results under the same input data conditions. The results revealed a difference in the migration of some nuclides between the codes, but confirmed that the dose trends at the end of the post-closure control period were similar for all exposure pathways. Based on the results of the dose evaluation predicted by RESRAD, sensitivity analysis on the input factors was performed and major input factors were derived. The uncertainty of the modeling results and the input factors were analyzed and the reliability of the safety evaluation results was confirmed. The results of this study can be applied to the implementation 'Safety Case Program' for the Gyeongju LILW disposal facility.

Dynamic Computed Tomography based on Spatio-temporal Analysis in Acute Stroke: Preliminary Study (급성 뇌졸중 환자의 시공간 분석 기법을 이용한 동적 전산화 단층 검사: 예비 연구)

  • Park, Ha-Young;Pyeon, Do-Yeong;Kim, Da-Hye;Jung, Young-jin
    • Journal of radiological science and technology
    • /
    • v.39 no.4
    • /
    • pp.543-547
    • /
    • 2016
  • Acute stroke is a one of common disease that require fast diagnosis and treatment to save patients life. however, the acute stroke may cause lifelong disability due to brain damage with no prompt surgical procedure. In order to diagnose the Stroke, brain perfusion CT examination and possible rapid implementation of 3D angiography has been widely used. However, a low-dose technique should be applied for the examination since a lot of radiation exposure to the patient may cause secondary damage for the patients. Therefore, the degradation of the measured CT images may interferes with a clinical check in that blood vessel shapes on the CT image are significantly affected by gaussian noise. In this study, we employed the spatio-temporal technique to analyze dynamic (brain perfusion) CT data to improve an image quality for successful clinical diagnosis. As a results, proposed technique could remove gaussian noise successfully, demonstrated a possibility of new image segmentation technique for CT angiography. Qualitative evaluation was conducted by skilled radiological technologists, indicated significant quality improvement of dynamic CT images. the proposed technique will be useful tools as a clinical application for brain perfusion CT examination.

Shielding Performance of PLA and Tungsten Mixture using Research Extruder (연구용 압출기를 활용한 PLA와 텅스텐 혼합물의 차폐 성능)

  • Do-Seong Kim;Tae-Hyung Kim;Myeong-Seong Yoon;Sang-Hyun Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.4
    • /
    • pp.557-564
    • /
    • 2023
  • In this study, 3D printing technology was used to compensate for the shortcomings of the use of lead, which has proven to have excellent shielding performance, and to control unnecessary human exposure. 3D printers can implement three-dimensional shapes and can immediately apply individual ideas, which has great advantages in maintaining technology supplementation while reducing the cost and duration of prototyping. Among the various special 3D printers, the FDM method was adopted, and the filament used for output was manufactured using a research extruder by mixing two materials, PLA (Poly-Lactic-Acid) and tungsten. The purpose was to verify the validity through dose evaluation and to provide basic information on the production of chapezones of various materials. The mixed filament was implemented as a morphological shield. Filaments made of a research extruder by mixing PLA and tungsten were divided into 10 %, 20 %, 30 %, 40 %, and 50 % according to the tungsten content ratio. Through the process of 3D Modeling, STL File storage, G-code generation, and output, 10 cm × 10 cm × 0.5 cm was manufactured, respectively, and dose and shielding ability were evaluated under the conditions of tube voltages of 60 kVp, 80 kVp, 100 kVp, 120 kVp, and tube currents of 20 mAs and 40 mAs.

Immune Cell Activation and Co-X-irradiation Effect of Eleutherococcus senticosus Maxim Root (가시오갈피 뿌리의 면역세포 활성 및 방사선 병용효과)

  • Kwon, Hyoung-Cheol;Park, Jeong-Seob;Choi, Dong-Seong
    • Radiation Oncology Journal
    • /
    • v.25 no.3
    • /
    • pp.185-191
    • /
    • 2007
  • Purpose: This study was performed to investigate the effects of immune cell activation and the antitumor effect for the combination of treatment with X-irradiation and E/eutherococcus senticosus Maxim Root (ESMR) on mouse tumor cells. Materials and Methods: ESMR (250g) was extracted with 80% methanol, concentrated under decompression and lyophilized. To determine whether ESMR is able to activate the immune cells or not, the proliferation of splenocytes in vitro and the number of B cells and T cells in splenic lymphocytes in ESMR-pretreated mice were evaluated. X-irradiation was given to the mouse fibrosarcoma tumor cells (FSa II) by 250 kv X-irradiation machine. The cytotoxicity of ESMR was evaluated from its ability to reduce the clonogenecity of FSa II cells. In X-irradiation alone group, each 2, 4, 6 and 8 Gy was given to FSa II cells. In X-irradiation with ESMR group, 0.2 mg/ml of ESMR was exposed to FSa II cells for 1 hour before X-irradiation. Results: The proliferation of cultured mouse splenocytes and thymocytes were enhanced by the addition of ESMR in vitro. The number of B cells and T cells in mouse splenic lymphocytes was significantly increased in ESMR pretreated mice in vivo. In FSa II cells that received a combination of 0.2 mg/ml of ESMR with X-irradiation exposure, the survival fraction with a dose of 2, 4 and 6 Gy was $0.39{\pm}0.005$, $0.22{\pm}0.005$ and $0.06{\pm}0.007$, respectively. For FSa II cells treated with X-irradiation alone, the survival fraction with a dose of 2, 4 and 6 Gy was $0.76{\pm}0.02$, $0.47{\pm}0.008$ and $0.37{\pm}0.01$. The difference in the survival fraction of the mouse FSa II cells treated with and without ESMR was statistically significant (p<0.05). Conclusion: Treatment with ESMR increased cell viability of mouse splenocytes in vitro and especially the subpopulation of B cells and T cells in splenocytes in ESMR-pretreated mice. However, treatment with ESMR did not increase the level of Th and Tc subpopulations in the thymocytes. Treatment with the combination of ESMR and X-irradiation was more cytotoxic to mouse tumor cells than treatment with X-irradiation alone; this finding was statistically significant.

The Evaluation on Reuse Period of Patient's Clothes and Sheet After Radioiodine Therapy (방사성 요오드 치료환자의 환의 및 시트에 대한 재사용주기 평가)

  • Kim, Yeong Seon;Seo, Myung Deok;Lee, Wan Kyu;Kim, Ki Joon;Song, Jae Beom
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.12-17
    • /
    • 2012
  • Purpose : The patient's clothes and sheet after radioiodine therapy must be disposed of by related regulation. That must be disposed of as radioactive wastes, but that is reusing after radioactivity decay by keeping for the certain period of time. In general, The minimum storage period calculate by standard of take radioactive substance out of radiation controlled area based on measured surface contamination level. But the measurements of surface contamination level are able to differ by measurement method. In this paper, I wish to calculate the minimum storage period of patient's clothes and sheet after radioiodine therapy by measure nuclide concentration offered by the regulation on self-disposal of radioactive wastes. Materials and Methods : The whole area of patient's clothes and sheet measured 31 patients(male:9 patients, female:22 patients), who had radioiodine therapy(3.7 GBq:13 patients, 5.55 GBq:16 patients, 7.4 GBq:2 patients) from july 2011 to march 2012. The minimum storage period is calculated by the regulation on self-disposal of radioactive waste(100 Bq/g) and standard of take radioactive substance out of radiation controlled area(4 kBq/m2) Results : The minimum storage period of pillow sheet, upper uniform, lower uniform by standard of take radioactive substance out of radiation controlled area were each 4.6 days, 63days, 78 days. The minimum storage period of pillow sheet, upper uniform, lower uniform by the regulation on self-disposal of radioactive waste were each 18.1 days, 43 days, 62 days. Conclusion : We can verify that patient's clothes and sheet after radioiodine therapy exists a great deal of radioactive contamination. The minimum storage period calculation of patient's clothes and sheet is better suited to applying nuclide concentration offered by the regulation on self-disposal of radioactive waste. I recommend, To keep for at least 2 months of the patient's clothes and sheet contaminated radioactivity, for prevent contamination and unnecessary radiation exposure.

  • PDF