• 제목/요약/키워드: Radiation Effect

검색결과 3,593건 처리시간 0.031초

플라스틱 하우스의 직달(直達) 및 산란(散亂) 일사량(日射量) 해석(解析) (Analysis of Direct and Diffuse Radiation in Plastic Greenhouse)

  • 고학균;김문기;김용현
    • 태양에너지
    • /
    • 제9권3호
    • /
    • pp.13-24
    • /
    • 1989
  • Direct and diffuse components of solar radiation were measured inside and outside a single-span plastic greenhouse. To analyze the direct solar radiation inside the plastic greenhouse, the cross-section of the greenhouse was assumed to be circular. Then the direct solar radiation transmitted into the greenhouse was calculated theoretically, and compared with the experimental measurements. The results are summarized as follows: (1) The transmissivities of total solar radiation were about 65% on cloudy days and 50% on clear days. For cloudy days, the transmissivity of the total solar radiation was regarded as the transmissivity of sky diffuse radiation. (2) The ratio of the inside effective scattered component of direct solar radiation to the diffuse radiation was 60-65%. (3) It appeared that the seasonal variation of the transmissivity of total solar radiation was adversely affected by the transmissivity of direct solar radiation and the effective scattered coefficient. But the effect of the transmissivity of direct solar radiation was dominant factor. (4) Computer simulation showed that the inside direct solar radiation was decreased as the floor of the plastic greenhouse was higher. (5) The predicted value of the inside direct solar radiation was 3.3% to 29.0% higher than the measured value.

  • PDF

적외선 레이저 자극이 흰쥐의 진통 작용에 미치는 영향 (Effect of Infra-red laser irradiation on pain relive in rats)

  • 이인학
    • The Journal of Korean Physical Therapy
    • /
    • 제9권1호
    • /
    • pp.89-96
    • /
    • 1997
  • The purpose of this study was to determine the effect of Ga-Al-As (Gallium-Aluminum-Arsenid) laser radiation on the tail-flick latency in rat. Thirty Sprague-Dawley male and female rats Were divided into five groups : that is control, laser 15sec radiation, laser 30sec radiation, laser 60sec radiation, and Tramadol Hcl injection groups. The continuous Ga-Al-As laser with, wave length 780-830nm and diameter of probe in the 3mm, averse output of 100mw radiation was applied to the meridian point(Gv 1 : Governing vessel) of the rats. Tail-flick latency were measured with hot plate at $55^{\circ}C$ : before treatment and immediately, 30 minutes, 1 hour, 2 hours, 24 hours, 24 hours and 48 hours after treatment. The result were as follows ; 1. The tail-flick latency according to time varition, control group was not significance. 2. The tail-flick latency according to time varition, laser 15 sec irradiate rats in post-treared was significance(P<0.05). 3. The tail-flick latency according to time varition, laser 30 sec irradiate rats group was not significance. 4. The tail-flick latency according to time varition, laser 60 sec irradiate rats in post 30 minute was significance(P<0.05). 5. The tail-flick latency according to time varition, Tramadol Hcl injection rats in post-treated (P<0.05), post 30 minute(P<0.05), post 60 minute (P<0.01) and 2 hour(P<0.05) was significance. This study suggest that Ga-Al-As (Gallium-Aluminum-Arsenid) laser applied to meridian point of the rat with 15 sec, 30 sec, and 60 set radiation could induc no analgesic effect, but Tramadol Hcl injection rat is good analgesic effect.

  • PDF

혈관내피세포에서 Vascular Endothelial Growth Factor가 방사선에 의해 유도된 apoptosis에 미치는 영향 (Vascular Endothelial Growth Factor Inhibits irradiation-induced Apoptosis in Human Umbilical Vein Endothelial Cells)

  • 이송재;김동윤
    • 대한방사선치료학회지
    • /
    • 제14권1호
    • /
    • pp.165-174
    • /
    • 2002
  • 혈관내피세포 성장 인자(Vascular endothelial growth factor, VEGF)는 혈관내피세포 특이하게 성장요인으로 작용하는 물질로 알려져 있다. 전리방사선에 대한 혈관내피세포의 효과는 정상조직에 대한 반응에 있어 아주 중요한 요소일 것으로 생각된다. 본 연구는 방사선 조사에 의해 배양시킨 혈관내피세포에서 apoptosis가 유도되는지, 유도가 된다면 VEGF에 의해 apoptosis가 억제되는지 그리고 apoptosis의 억제가 어떤 경로를 경유하는지를 실험하였다. 혈관내피세포에 방사선를 조사한 결과, 대조군에 비하여 선량이 증가함에 따라 apoptosis가 증가하였다. 같은 조건하에서 VEGF는 농도 의존적으로 apoptosis를 억제하였다. Antiapoptotic factor로서 VEGF가 어떤 신호 과정을 경유하는지를 밝히고자, 혈관내피세포에 방사선을 조사하여 apoptosis를 유도하면서 Flt-1과 Flk-1/KDR receptor를 처리하였다. 그결과 VEGF에 유도된 apoptosis 억제효과가 차단되었다. Phosphatidylinositol 3'-kinase(PI3-kinase) 특정 억제 물질인 Wortmanin과 LY294002를 방사선 조사한 혈관내피에 VEGF와 함께 처리했을 때 VEGF에 의해 유도된 apoptosis를 억제하였다. 이같은 결과는 VEGF가 방사선 조사로 일어나는 세포 치사를 억제하는 중요한 역할을 담당하며, In Vivo의 실험이 더 이루어져야 할 것으로 생각된다.

  • PDF

몬테카를로 방법을 이용한 슬릿형태 구조물의 차폐능력 평가 (Shielding Capability Evaluation of Slit-shaped Structure for Scattered X-ray using Monte Carlo Method)

  • 김상록;허재승
    • 한국방사선학회논문지
    • /
    • 제14권6호
    • /
    • pp.733-740
    • /
    • 2020
  • 의료종사자의 피폭선량을 줄이기 위한 최근 연구에서, 방사선이 산란될 때 발생하는 광전효과를 이용하여 방사선치료실 입구에서의 선량을 줄이는 방법이 제안되었다. 이 방법은 특히 저에너지 광자에 효과적이기 때문에 본 연구에서는 몬테카를로 시뮬레이션을 이용하여 슬릿형태 구조물의 일반촬영실 산란 엑스선에 대한 차폐성능을 평가하였다. 두께 2 mm, 폭 50 mm, 길이 900 mm인 판을 2 mm 간격으로 수평 적재하는 형태의 슬릿형태 구조물은 알루미늄에 비해 철 또는 납으로 만드는 경우 차폐효과가 뛰어났다. 재질을 철로 한정한 경우 선원과 관심구역 사이에서 결정된 구조물의 설치위치는 차폐효과와 무관했으며, 판의 폭은 차폐효과에 비례했다. 폭 50 mm 철판을 사용한 경우 산란선이 직접 발생하는 바닥 및 환자의 높이를 제외하면 약 99.9% 또는 그 이상의 차폐효과가 있었다.

Monte Carlo simulation of spatial resolution of lens-coupled LYSO scintillator for intense pulsed gamma-ray imaging system with large field of view

  • Guoguang Li;Liang Sheng;Baojun Duan;Yang Li;Dongwei Hei;Qingzi Xing
    • Nuclear Engineering and Technology
    • /
    • 제56권7호
    • /
    • pp.2650-2658
    • /
    • 2024
  • In this paper, we use a Monte Carlo (MC) simulation based on Geant4 to investigate the influence of four parameters on the spatial resolution of the lens-coupled lutetium yttrium orthosilicate (LYSO) scintillator, including the thickness of the LYSO scintillator, the F-number and minification factor of the lens, and the incident position of the gamma-rays. Simulation results show that when the gamma-rays are incident along the lens axis, the smaller the thickness, the larger the F-number, the larger the minification factor, the higher the spatial resolution, with an isotropic point spread function (PSF). As the incident position of the gamma-rays deviates from the lens axis, the spatial resolution decreases, and the PSF becomes anisotropic. In addition, by analyzing the whole physical process of the lens-coupled LYSO scintillator from gamma-rays to secondary electrons to fluorescence photons, we aim to provide a detailed analysis of the influence of each parameter on the spatial resolution. The results show that the PSF of the secondary electrons energy deposition is almost constant in the simulation, which determines the upper limit of the spatial resolution. Meanwhile, the dispersion process of the fluorescence photons can explain the reason why each parameter affects the spatial resolution.

전뇌 방사선 치료 시 갑상선 차폐체의 주변선량 차폐효과에 대한 유용성 평가 (Evaluation of usability of the shielding effect for thyroid shield for peripheral dose during whole brain radiation therapy)

  • 양명식;차석용;박주경;이승훈;김양수;이선영
    • 대한방사선치료학회지
    • /
    • 제26권2호
    • /
    • pp.265-272
    • /
    • 2014
  • 목 적 : 전뇌 방사선 치료 시 산란선으로 인하여 영향을 받는 갑상선의 피폭선량을 감소시키기 위해 차폐체를 사용하여 갑상선의 차폐 효과를 평가하고자 한다. 대상 및 방법 : 갑상선의 피폭선량을 측정하기 위해 선형가속기(Clinac iX. VARIAN, USA)를 이용하여 6 MV X선, 300 cGy를 인체모형팬텀에 대향 2문 조사하였다. 갑상선의 입사표면선량을 측정하기 위해 인체모형팬텀의 10번째 슬라이스 표면에 유리선량계 다섯 개를 1.5 cm 간격으로 위치시킨 후 차폐체 미사용, bismuth 차폐체 사용, 0.5 mmPb 차폐체 사용, 자체 제작한 1.0 mmPb 차폐체를 사용하여 각각 5회씩 측정하여 평균값을 산출하였다. 또한, 같은 위치에서 갑상선 심부선량을 측정하기 위해서 인체모형팬텀의 10번째 슬라이스 2.5 cm 깊이에서 유리선량계 다섯 개를 1.5 cm 간격으로 위치시킨 후 차폐체 미사용, bismuth 차폐체 사용, 0.5 mmPb 차폐체 사용, 자체 제작한 1.0 mmPb 차폐체를 사용하여 각각 5회씩 측정하여 평균값을 산출하였다. 결 과 : 갑상선의 입사표면선량은 차폐체 미사용 시 44.89 mGy로 측정되었고, bismuth 차폐체는 36.03 mGy, 0.5 mmPb 차폐체는 31.03 mGy, 자체 제작한 1.0 mmPb 차폐체는 23.21 mGy로 측정되었다. 또한, 갑상선의 심부선량은 차폐체 미사용 시 36.10 mGy로 측정되었고, bismuth 차폐체는 34.52 mGy, 0.5 mmPb 차폐체는 32.28 mGy, 자체 제작한 1.0 mmPb 차폐체는 25.50 mGy로 측정되었다. 결 론 : 전뇌 방사선 치료 시 방사선 조사면 밖의 영역에서 발생하는 이차 산란 및 누출 선량에 의해 영향을 받는 갑상선에 대하여 차폐체를 사용했을 때 갑상선 심부는 약 11~30%, 갑상선 표면은 약 20~48% 정도의 피폭선량 감소 효과가 나타났다. 따라서 전뇌 방사선 치료 시 갑상선 차폐체를 사용함으로써 갑상선을 효과적으로 보호하며 치료를 시행할 수 있을 것으로 사료된다.

Intent to Use a Smartphone Application for Radiation Monitoring in Correlation with Anxiety about Exposure to Radiation, Recognition of Risks, and Attitudes toward the Use of Radiation

  • Han, Eunkyoung;Rott, Carsten;Hong, Seung-Woo
    • Journal of Radiation Protection and Research
    • /
    • 제42권4호
    • /
    • pp.205-211
    • /
    • 2017
  • Background: Radiation is used in a variety of areas, but it also poses potential risks. Although radiation is often used with great effectiveness in many applications, people perceive potential risks associated with radiation and feel anxious about the possibility of radiation exposure. Various methods of measuring radiation doses have been developed, but there is no way for the general public to measure their doses with ease. Currently, many people use smartphones, which provide information about the location of an individual phone through network connections. If a smartphone application could be developed for measuring radiation dosage, it would be a very effective way to measure individuals' radiation doses. Thus, we conducted a survey study to assess the social acceptance of such a technology by the general public and their intent to use that technology to measure radiation doses, as well as to investigate whether such an intention is correlated with anxiety and attitudes toward the use of radiation. Materials and Methods: A nationwide online survey was conducted among 355 Koreans who were 20 years old or older. Results and Discussion: Significant differences were found between the genders in attitudes, perceptions of radiation risk, and fears of exposure to radiation. However, a significant difference according to age was observed only in the intent to use a smartphone dose measurement application. Attitudes towards the use of radiation exerted a negative effect on radiation risk perception and exposure anxiety, whereas attitudes towards the use of radiation, risk perception, and anxiety about exposure were found to have a positive impact on the intent to use a smartphone application for dose measurements. Conclusion: A survey-based study was conducted to investigate how the general public perceives radiation and to examine the acceptability of a smartphone application as a personal dose monitoring device. If such an application is developed, it could be used not only to monitor an individual's dose, but also to contribute to radiation safety information infrastructure by mapping radiation in different areas, which could be utilized as a useful basis for radiation research.

Ginkgo Biloba Extract가 마우스 피부 및 공장 소낭선의 방사선감수성에 미치는 영향 (The Effect of Ginkgo Biloba Extract on Radiosensitivity of Mouse Skin and Jejunal Crypt)

  • 신경환;하성환
    • Radiation Oncology Journal
    • /
    • 제16권2호
    • /
    • pp.107-114
    • /
    • 1998
  • 목적 : 혈관수축이완작용 및 혈액점도저하의 약리작용을 가져 말초혈관의 혈류를 증가시키는 것으로 알려진 은행잎 추출물인 Ginkgo biloba extract(GBE) 투여후 방사선 조사시 마우스 종양에서 방사선 효과가 증강됨이 확인되었다. 즉 저산소세포 분획이 감소되었으며 따라서 암조직의 혈류증가가 간접적으로 증명되었다. 방사선효과 증강제인 경우 암조직에 대한 효과가 정상조직에 대한 효과보다 더 커야한다는 것은 필수적이다. 이에 저자들은 GBE 투여후 방사선조사시 마우스 정상조직 급성 반응의 증가여부 및 그 정도를 확인하기 위하여 본 실험을 시행하였다. 대상 및 방법 : 방사선에 대한 급성 피부 반응의 측정 및 공장 재생 소낭선 측정을 위해서 C3H 마우스를 방사선 단독 조사군과 GBE 투여후 방사선조사군으로 나누었다. GBE는 방사선조사 24시간 전과 1시간 전에 각각 복강 내에 2회 주사하였다. 급성 피부 반응 측정 실험에서는 30-50Gy가 마우스 우측 하지에 조사되었고, 공장 재생 소낭선 측정 실험에서는 11-14Gy가 마우스 전신에 조사되었다. 결과 : 방사선에 의한 급성 피부반응 점수 2.0 이상에 해당하는 $RD_{50}$는 방사선 단독조사군에서 44.2Gy(40.6-48.2Gy)이었고, GBE 투여후 방사선 조사시에는 44.4Gy(41.6-47.4Gy)로서 GBE에 의한 영향이 없었다. 방사선 단독 조사군 및 GBE 투여후 방사선조사군의 각 방사선량에 따른 마우스 공장 재생 소낭선의 수는 차이를 보이지 않았다(p=0.57-0.94). 평균치사선량($D_0$)은 방사선 단독조사시 1.80Gy(1.57-2.09Gy), G8E 투여후 방사선조사를 병용시 1.88Gy(1.65-2.18Gy)로서 GBE에 의한 영향이 없었다. 결론 : C3H 마우스에서 방사선에 의한 급성 정상조직 손상은 GBE에 의하여 전혀 증가되지 않는 것으로 판단되며 이미 증명된 종양세포에 대한 치료효과의 증강과 더불어 방사선치료시 GBE를 병용함으로써 치료적 이득을 얻을 수 있을 것으로 예상된다.

  • PDF

Neutron Dosimetry and Monitoring in the Radiation Environment

  • Nakamura, Takashi
    • Journal of Radiation Protection and Research
    • /
    • 제14권2호
    • /
    • pp.51-62
    • /
    • 1989
  • The high efficiency moderated-type neutron spectrometer and doseequivalent counter were developed for the measurement of low level environmental neutrons. By using these detectors, the neutron energy spectra and dose equivalent rates due to skyshine effect were measured in the environment surrounding the accelerator facilities and also the altitude variation of cosmic ray neutrons in the aircraft flying over Japan.

  • PDF