• Title/Summary/Keyword: Radiation Dosimetry

Search Result 607, Processing Time 0.023 seconds

Second intercomparison on electron paramagnetic resonance (EPR) retrospective dosimetry in Korea using hydroxyapatite

  • HyoJin Kim;Jae Seok Kim;Byeong Ryong Park;Seongjae Jang;Han-Ki Jang;Ki-Taek Han;Hoon Choi;Jeongin Kim;In Jung Kim;Yunho Kim;Wi-Ho Ha;Jungil Lee;Yeong-Rok Kang
    • Nuclear Engineering and Technology
    • /
    • v.55 no.12
    • /
    • pp.4576-4582
    • /
    • 2023
  • The Korea retrospective dosimetry (KREDOS)-electron paramagnetic resonance (EPR) group undertook an intercomparison investigation utilizing hydroxyapatite. This analysis involved four institutions: the Korea Institute of Radiological and Medical Sciences, Dongnam Institute of Radiological and Medical Sciences, Korean Association for Radiation Application, and Radiation Health Institute of Korea Hydro & Nuclear Power. Following the irradiation of the hydroxyapatite sample, the recorded build-up was analyzed. To validate the reliability of the EPR dosimetry findings and enhance its operational performance, a hydroxyapatite dose-response curve was plotted and dosimetry was performed for a blind sample. The proficiency of each laboratory was assessed by employing an interlaboratory comparison methodology. This involved a comparative analysis of the measurement results by calculating the relative bias, z-score, and En value. The results submitted by the participating laboratories demonstrated satisfactory ratings for doses of 1.006, 3.999, and 6.993 Gy. Following the second intercomparison, efforts to optimize their hydroxyapatite-EPR dosimetry systems are underway in the participating laboratories. The current assessment of hydroxyapatite dose yielded the foundational data required to establish the parameters of dental dosimetry. In future, the third intercomparison experiment will be conducted for exploring other materials.

Internal Radiation Dosimetry in Radionuclide Therapy (방사성핵종을 이용한 치료에서 흡수선량의 평가)

  • Kim, Kyeong-Min;Lim, Sang-Moo
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.40 no.2
    • /
    • pp.120-126
    • /
    • 2006
  • Radionuclide therapy has been continued for treatment of incurable diseases for past decades. Relevant evaluation of absorbed dose in radionuclide therapy is important to predict treatment output and essential for making treatment planning to prevent unexpected radiation toxicity. Many scientists in the field related with nuclear medicine have made effort to evolve concept and technique for internal radiation dosimetry in this review, basic concept of internal radiation dosimetry is described and recent progress in method for dosimetry is introduced.

Current Status of Internal Dosimetry Methods and Radiological Regulations in Korea, Ukraine and European Community

  • Lee, Tae-Young;Lee, Jong-Il;Berkovski, Vladimir
    • Journal of Radiation Protection and Research
    • /
    • v.28 no.1
    • /
    • pp.65-73
    • /
    • 2003
  • The paper discusses results of recent international intercomparison exercises on internal dose assessments, status of up to date internal dosimetry methods and the radiological legislation developed and implemented in Korea, European Union and Ukraine. The system of radiation protection in Korea is based on the Korean Atomic Energy Regulatory Enforcement on Safety Standards (Ministry Notice No. 2001-2). The notice is based on the recommendations in ICRP Publication 60 (1990) and IAEA Basic Safety Standards (1996). But the full implementation of the notice by the end of the year 2002 is not required because of the socio-economic situation and inexperience in internal radiation dosimetry Regulatory framework for internal radiation dosimetry is under development toward the full implementation of the notice from January 1, 2003. The system of radiation protection in Ukraine is based on the National radiation protection regulatory code NRBU-97. The code was developed and adopted in 1998 and replaced the Regulations of Former Soviet Union. The document is based on the ICRP Publication 60, Euratom Directive 96/29 and IAEA Basic Safety Standards (1996). The transitional period of 5 years (effected till January 2003) is established for implementation of all requirements of this new regulation. The system of radiation protection in the European Community is based on the Council Directive 96/29/Euratom, adopted in 1996 and enforced from 13 May 2000. Directive 96/29/Euratom has the status of the European law.

Fingernail electron paramagnetic resonance dosimetry protocol for localized hand exposure accident

  • Jae Seok Kim;Byeong Ryong Park;Minsu Cho;Won Il Jang;Yong Kyun Kim
    • Nuclear Engineering and Technology
    • /
    • v.55 no.1
    • /
    • pp.270-277
    • /
    • 2023
  • Exposure to ionizing radiation induces free radicals in human nails. These free radicals generate a radiation-induced signal (RIS) in electron paramagnetic resonance (EPR) spectroscopy. Compared with the RIS of tooth enamel samples, that in human nails is more affected by moisture and heat, but has the advantages of being sensitive to radiation and easy to collect. The fingernail as a biological sample is applicable in retrospective dosimetry in cases of localized hand exposure accidents. In this study, the dosimetric characteristics of fingernails were analyzed in fingernail clippings collected from Korean donors. The dose response, fading of radiation-induced and mechanically induced signals, treatment method for evaluation of background signal, minimum detectable dose, and minimum detectable mass were investigated to propose a fingernail-EPR dosimetry protocol. In addition, to validate the practicality of the protocol, blind and field experiments were performed in the laboratory and a non-destructive testing facility. The relative biases in the dose assessment result of the blind and field experiments were 8.43% and 21.68% on average between the reference and reconstructed doses. The results of this study suggest that fingernail-EPR dosimetry can be a useful method for the application of retrospective dosimetry in cases of radiological accidents.

Proficiency Test for the Dosimetry Audit Service Provider

  • Chul-Young Yi;In Jung Kim;Jong In Park;Yun Ho Kim;Young Min Seong
    • Progress in Medical Physics
    • /
    • v.33 no.4
    • /
    • pp.72-79
    • /
    • 2022
  • Purpose: The proficiency test was conducted to assess the performance of the dosimetry audit service provider in the readout practice of the dose delivered to patients in medical institutions. Methods: A certain amount of the absorbed dose to water for the high-energy X-ray from the medical linear accelerator (LINAC) installed in the Korea Research Institute of Standards and Science (KRISS) was delivered to the postal dose audit package given by the dosimetry audit service provider, in which the radio-photoluminescence (RPL) glass dosimeters were mounted. The dosimetry audit service provider read the RPL glass dosimeters and sent the readout dose value with its uncertainty to KRISS. The performance of the dosimetry audit service provider was evaluated based on the En number given in ISO/IEC 17043:2010. Results: The evaluated En number was -0.954. Based on the ISO/IEC 17043, the performance of the dosimetry service provider is "satisfactory." Conclusions: As part of the conformity assessment, the KRISS performed the proficiency test over the postal dose audit practice run by the dosimetry audit service provider. The proficiency test is in line with confirming the traceability of the medical institutions to the primary standard of absorbed dose to the water of the KRISS and ensuring the confidence of the dosimetry audit service provider.

Gamma Evaluation with Portal Dosimetry for Volumetric Modulated Arc Therapy and Intensity-Modulated Radiation Therapy

  • Kim, Jung-in;Choi, Chang Heon;Park, So-Yeon;An, HyunJoon;Wu, Hong-Gyun;Park, Jong Min
    • Progress in Medical Physics
    • /
    • v.28 no.2
    • /
    • pp.61-66
    • /
    • 2017
  • The aim of this study is to investigate the characteristics of portal dosimetry in comparison with the MapCHECK2 measurments. In this study, a total of 65 treatment plans including both volumetric modulated arc therapy (VMAT) and intensity-modulated radiation therapy (IMRT) were retrospectively selected and analyzed (45 VMAT plans and 20 IMRT plans). A total of 4 types of linac models (VitalBeam, Trilogy, Clinac 21EXS, and Clianc iX) were used for the comparison between portal dosimetry and the MapCHECK2 measurements. The VMAT plans were delivered with two VitalBeam linacs (VitalBeam1 and VitalBeam2) and one Trilogy while the IMRT plans were delivered with one Clinac 21EXS and one Clinacl iX. The global gamma passing rates of portal dosimetry and the MapCHECK2 measurements were analyzed with a gamma criterion of 3%/3 mm for IMRT while those were analyzed with a gamma criterion of 2%/2 mm for VMAT. Spearman's correlation coefficients (r) were calculated between the gamma passing rates of portal dosimetry and those of the MapCHECK2 measurements. For VMAT, the gamma passing rates of portal dosimetry with the VitalBeam1, VitalBeam2, and Trilogy were $97.3%{\pm}3.5%$, $97.1%{\pm}3.4%$, and $97.5%{\pm}1.9%$, respectively. Those of the MapCHECK2 measurements were $96.8%{\pm}2.5%$, $96.3%{\pm}2.7%$, and $97.4%{\pm}1.3%$, respectively. For IMRT, the gamma passing rates of portal dosimetry with Clinac 21EXS and Clinac iX were $99.7%{\pm}0.3%$ and $99.8%{\pm}0.2%$, respectively. Those of the MapCHECK2 measurements were $96.5%{\pm}3.3%$ and $97.7%{\pm}3.2%$, respectively. Except for the result with the Trilogy, no correlations were observed between the gamma passing rates of portal dosimetry and those of the MapCHECK2 measurements. Therefore, both the MapCHECK2 measurements and portal dosimetry can be used as an alternative to each other for patient-specific QA for both IMRT and VMAT.

Dosimetry of Irregular Field Using Thermoluminescence Dosimetry (부정형 조사면에서의 TLD를 이용한 방사선 흡수선량 측정)

  • Lee, Jong-Young;Park, Kyung-Ran;Kim, Kye-Jun
    • Radiation Oncology Journal
    • /
    • v.12 no.2
    • /
    • pp.263-267
    • /
    • 1994
  • In clinical radiotherapy, the use of wide and irregular field techniques frequently results in considerable tumor dose inhomogeneity because of, the variation in physical characteristics of irradiated volumes. This report describes an analysis of the dosimetry of the irregular fields such as radiation fields for Hodgkin's disease(mantle field), esophageal cancer, and lung cancer when a 6 MV and a 15 MV linear accelerators are utilized. Doses were measured in a Rando phantom using methods of thermoluminescence dosimetry(TLD), and were calculated by radiotherapy planning computer system with the Clarkson's method for calculation of a irregular field. A dose variation of $5-22\%,\;6-9\%,\;6-14\%$ were found in the mantle field, esophageal cancer field, lung cancer field respectively. Higher doses occurred in the superior portion of the irregular field. The sites of maximum dose variation were the supraclavicular and the upper spinal cord region. To adjust for these substantial differences, a compensator or a shrinking field technique should be adopted.

  • PDF

ESR dosimetry and Dating toward $21^{st}$ Century

  • Ikeya, Motoji
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.6 no.2
    • /
    • pp.84-88
    • /
    • 2002
  • Dating and dosimetry using electron spin resonance (ESR) in 20th Century developed at both Yamaguchi University and Osaka University have been reviewed with emphasis on new prospects and strategies in 21th century. Natural radiation have been generating radicals that accumulated in archaeological and geological materials. ESR detects these radicals and the ESR signal intensity is proportional to the radiation dose and therefore the age. The assessment of the total dose of natural radiation and the annual dose rate give their ESR ages. The ESR dating of stalactites and stalagmites ant Akiyoshi cave in Yamaguchi prefecture in 1975 was extended to anthropological dating using bones and tooth enamel excavated in Greek Petralona cave. Fossils of shells and corals gave the ages of marine terraces and sea-level changes. Quartz grains gave the ages of geothermal alteration and fault movements. Future ESR dating of ices at outer planets anf their satellite are also investigated as basic studies for ices od $H_2O,\;CO_2,\;SO_2$ as well as terrestrial hydrates in laboratory. Atomic bomb radiation dosimetry at Hiroshima and Nagasaki using ESR lead to the dosimetry of personnel, Chemobyl and JCO criticality accidents. Monitoring of radiation dose with sensitive materials with tissue equivalence are being developed. finally a new scanning ESR imaging apparatus (a near field microwave microscope) developed in our laboratory gave ESR images of Radicals from fossils to Si-CVD and diamond films as summarized in my book in 2002.

  • PDF

Medical Application of Radiation Internal Dosimetry (방사선 내부흡수선량의 의학적 적용)

  • Kim, Kyeong-Min;Lim, Sang-Moo
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.2
    • /
    • pp.164-171
    • /
    • 2008
  • Medical internal radiation dosimetry (MIRD) is an important part of nuclear medicine research field using therapeutic radioisotope. There have been many researches using MIRD for the development of new therapeutic approaches including radiopharmaceutical, clinical protocol, and imaging techniques. Recently, radionuclide therapy has been re-focused as new solution of intractable diseases, through to the advances of previous achievements. In this article, the basic concepts of radiation and internal radiation dosimetry are summarized to help understanding MIRD and its application to clinical application.

PRELIMINARY STUDY OF WATER CONTENTS AND SIGNAL BEHAVIOR IN FINGERNAIL/EPR DOSIMETRY

  • Choi, Hoon;Choi, Sul A;Lee, Byungil
    • Journal of Radiation Protection and Research
    • /
    • v.38 no.4
    • /
    • pp.185-188
    • /
    • 2013
  • Heating method using electric heater was used to reduce water content in fingernail clippings. Authors found that low water content is helpful to measure EPR signal of fingernail sample with enhanced variability. Generally, natural dehydration happens in normal room condition at least one month and needs much time for using in experiment. So, artificial heating method is applied in this study for time savings. Fingernail samples were tested to find effect of water content to the EPR signal on microwave power levels for dosimetry. Low water content in fingernail reduced variability of EPR signal and makes it possible to measure accurate EPR signal. It also made it possible to measure constant movement of EPR signals on several microwave power levels. Although this method was difficult to apply directly in fingernail/EPR dosimetry, we, authors, believe that this heating method would be useful to differentiate MIS2 and RIS which are generally located at the same g-factor and almost impossible to be identified with each other.