• Title/Summary/Keyword: Radiant heating

Search Result 143, Processing Time 0.022 seconds

Analysis of Temperature Distribution of the Glass Panel in the Infrared Heating Chamber (적외선 가열로에서 가열되는 유리 패널의 온도분포 해석)

  • Lee, Kong-Hoon;Kim, Ook-Joong;Ha, Su-Seok;Kang, Sae-Byul;Lee, Joon-Sik
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.278-283
    • /
    • 2003
  • Analysis has been carried out to investigate the temperature variation and the uniformity of the temperature distribution of the glass panel by infrared radiant heating. Halogen lamps are used to heat the panel and located near the top and bottom of the rectangular chamber. The thermal energy is transfered only by radiation and the radiation exchange occurs only on the solid surfaces and is considered by using the view factor. The results show that the uniformity of the temperature distribution of the panel is improved but the time for heating increases as the wall reflectivity is large. The temperature difference reaches a maximum in the early stage of the heating process and then decreases until it reaches the uniform steady-state value.

  • PDF

A study on the radiant heat exchange in living space (거주공간에서의 복선열교환에 관한 연구 -착의시의 착의부와 노출부의 열수수)

  • 윤정숙
    • Journal of the Korean Home Economics Association
    • /
    • v.24 no.2
    • /
    • pp.75-82
    • /
    • 1986
  • This study was measured experimentally the Configuration factor of the adult female with the purpose of explaning quantitatively the human body's radiant heat exchange in a small scale of a house. And it is a investigatio about human clothed body's heat resistance which have great influence on radiant heat exchange. The result of this study was diagrammatized the [Shape×Area Factor] for the sake of making it easy to calculate the quantity of the actual human body's radiant heat exchange, and designed a diagram to make it easy to find the value of the human clothed body's heat resistance and clothing surface temperature. Thus, this research can be used as a basic resource for not only calculating wuantitatively radiant heat exchange of human clothed body and unclothed body in the radiant heating system of low temperature but also designing the thermal environment in a room.

  • PDF

A Study on the Required Supply Water Temperature Calculating Method for the Control of Multizone Radiant Floor Heating System (멀티존 온돌난방제어를 위한 필요공급온수온도 산출법에 관한 연구)

  • Choi, Jeong-Min;Lee, Kyu-Nam;Ryu, Seong-Ryong;Kim, Yong-Yee;Yeo, Myoung-Souk;Kim, Kwang-Woo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.1
    • /
    • pp.77-85
    • /
    • 2007
  • One of the most common approaches to achieve better thermal comfort with the radiant floor heating system is supply water temperature control, which is that supply water temperature is varied with outdoor air temperature. But the application of this control method was not easy, because there has been no way to determine the supply water temperature. So in this study, a comprehensive, yet simple calculation method to find out the required supply water temperature is suggested by combining the building heat loss equation and the heat emission model of hydronic radiant floor heating system for single zone. And then using this calculation method, the multizone control method is suggested and confirmed through the thermal simulation. It is shown that indoor air temperature is stably maintained around the set point.

The Effects of Heat Diffusion Fin on the Thermal Behavior and Performance of Radiant Heatomg Panel (방열핀이 난방용 패널의 열적거동 및 성능에 미치는 영향)

  • 이태원
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.9
    • /
    • pp.2486-2493
    • /
    • 1994
  • Transient heat transfer characteristics in th radiant heating panel with heat diffusion fin were predicted by numerical analysis. Thermal behaviors of panel, such as temperature distributions in panel and convective and radiative heat fluxes in panel surface with advance of time, were obtained for several important parameters. The performance and thermal comfort of heating panel were studied and compared for various design conditions, such as pipe pitch, area ratio and thermal conductivity of optimal design of the new heating panels with heat diffusion fin. It was concluded that the efficient area ratio of heat diffusion fin is about 0.5, and the greater the thermal conductivity of fin is, the better the performance of panel is.

A Study on the Performance of Automatic Thermostatic Valves for Hot Water Heating System in Residential Buildings (공동주택 난방용 자동온도조절기의 성능해석 연구)

  • Ahn, Byung-Cheon;Lee, Tae-Won;Kim, Yong-Ki;Song, Jae-Yeob
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.457-462
    • /
    • 2005
  • In this study, the performance of automatic thermostatic valves according to each heating method of a large scale residential building were researched by simulation. The flow characteristics of the entire pipe networks of the hot water radiant heating system is analized by using linear analysis method. For the analysis of unsteady heat transfer phenomena in each household, the method of using electric equivalent R-C circuit is applied.

  • PDF

Application Study on the Outdoor Air Temperature Prediction Control for Continuous Floor Heating System (연속바닥난방시스템에 대한 외기예측제어적용 연구)

  • 태춘섭;조성환;이충구
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.9
    • /
    • pp.836-844
    • /
    • 2001
  • For the radiant floor heating system, the possibility of suboptimal prediction control was investigated by computer simulation and experiment. For this study, TRANSYS program was used and an experimental facility consisting of two rooms (3$\times$4.4$\times$2.8m) was built. The facility enabled simultaneous comparison of two different control strategies which implemented in a separate room. Results showed that outdoor air temperature prediction control was superior to the conventional outdoor air temperature compensation control for radiant floor heating system. However, more research for fine prediction of outside air temperature was required in the future.

  • PDF

An Experimental Study on the Control Methods of Radiant Floor Heating Systems (바닥복사 난방시스템의 제어방식에 관한 실험적 연구)

  • 김오봉;이진영;여명석;석호태;김광우
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.12
    • /
    • pp.1297-1305
    • /
    • 2001
  • In this study, existing control methods that are suggested or applied until now are classified by control parameters, and stability of in the room and floor surface temperatures of each control method is compared through experiments. Then, the control performance of these control methods are analyzed to evaluate the applicability to Korean apartment housing. From the result of the applicability analysis, the outdoor reset with on/off PWM control is found to be desirable for district heating systems and flux modulation is found to be applicable for decentralized heating systems. In the case of independent control systems for each room, on/off PWM control is desirable.

  • PDF

A Study on the Improvement of Indoor Thermal Performance of Floor Radiant Heating System Considering Valve Operation Characteristics (바닥복사 난방시스템의 밸브구동 특성을 고려한 실내 열환경 성능 개선 연구)

  • Song, Jae-Yeob;Ahn, Byung-Cheon
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.17 no.4
    • /
    • pp.36-45
    • /
    • 2021
  • In this study, to improve the indoor thermal environment of the radiant floor heating system, a study was conducted on the temperature change characteristics and energy consumption according to the change of the indoor air set temperature, the supply hot water temperature and the outdoor temperature. As for the control method, the on/off control and the thermal difference proportional control method proposed through previous studies were applied. In addition, in consideration of field applicability, numerical analysis was performed for the case where the indoor air temperature sensor was affected by the wall temperature. As a result, it was found that the temperature difference proportional control method is more effective for thermal comfort and energy saving than on/off control.

Development of a Small Radiant Sequential Production System for Aspheric Lens (소형 복사방식 순차제조 비구면 렌즈 제조시스템 개발)

  • Kuk, Kum-Hoan;Jeong, Jun-Hyo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.27 no.12
    • /
    • pp.67-74
    • /
    • 2010
  • The fabrication method of aspheric lens is changed from machining to press molding so as to improve the productivity. In the case of the press molding method, the temperature control of the molding die is most impotent, because the temperature of each molding die determines the quality of lens. But any practical method for direct measuring of the lens temperature and the die internal temperature is yet unknown. Besides, in the case of the press molding system in which the heating and pressing and cooing of a die is done at one work station, the cycle time for the system is yet too long. The paper shows an improved structure of radiant sequential system in which the heating and pressing and cooing of dies is done at individual work station so as to cut down the cycle time. To know the die internal temperature, numerical results are given using ANSYS. An experimental radiant sequential system is developed and tested. Finally, the Taguchi method is applied in order to optimize the setting conditions of individual work station.

An Experimental Study on Control Performance of Radiant Floor Cooling Using Ondol (온돌을 이용한 바닥복사냉방의 제어성능에 관한 실험적 연구)

  • 김용이;임재한;한여명;김광우
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.11
    • /
    • pp.1165-1173
    • /
    • 2001
  • The objectives of this study are to analyze the application of radiant floor cooling and to evaluate the control methods through experiments when the radiant heating system is used for cooling. Through the experiment analysis the control methods such as on/off control, variable flow control and outdoor reset with indoor temperature feedback control are evaluated and compared. The cooling curve (reset ratio) is found for radiant cooling, which shows tole relation between outside air temperature and supply water temperature. Comparison of cooling methods shows that outdoor reset with indoor temperature feedback control is more appropriate than on/off control and variable flow control with regard to prevention of the condensation and thermal comfort.

  • PDF