This study was measured experimentally the Configuration factor of the adult female with the purpose of explaning quantitatively the human body's radiant heat exchange in a small scale of a house. And it is a investigatio about human clothed body's heat resistance which have great influence on radiant heat exchange. The result of this study was diagrammatized the [Shape×Area Factor] for the sake of making it easy to calculate the quantity of the actual human body's radiant heat exchange, and designed a diagram to make it easy to find the value of the human clothed body's heat resistance and clothing surface temperature. Thus, this research can be used as a basic resource for not only calculating wuantitatively radiant heat exchange of human clothed body and unclothed body in the radiant heating system of low temperature but also designing the thermal environment in a room.
There is a chilled ceiling panel which carries out the air conditioning by radiation and convection between the room and cold ceiling panel surface. In order to verify heat transfer characteristics between them in cooling system with radiant chilled ceiling panel, analytical and experimental studies were performed for various design and operating parameters such as tube space and diameter, inlet water temperature, mass flow rate, cooling load, and so on. In this study, we found that the tube space and inlet water temperature were more important elements than the tube diameter and water flow rate for the performance of radiant chilled ceiling panel. The cooling capacity of the radiant chilled ceiling panel had the maximum value of $65W/m^{2}$ because the highest cooling capacity was limited by the condensation on the panel surface. The results of comparison between numerical analysis and experiment showed a resonable agreement qualitatively, especially for low cooling capacity.
the change of physical properties (thickness, weight, air permeability) and mechanical properties(abrasion resistance breaking load and displacement) of samples were determined after heat exposure by a RPP tester. The effect of exposure time and heat flux intensity on the changes and the relationship between physical properties and mechanical properties were investigated. FR treated cotton Kevlar/PBI and Nomex with different structureal characteristics were chosen for specimens. The changes of physical properties and mechanical properties were calculated based on their initial values before heat exposure. The longer exposure time and the high heat flux intensity the more changes of those properties. Heat flux intensity was more effective on the changes, The showed to be affected by an interplay of shrinkage and pyrolysis products loss. The changes of thickness and abrasion resistance showed to be higher for plain weave fabric and those of air permeabiliyt and breaking load and displacement for twill weave fabric. While FR treated cotton which have high RPP value experienced serious and detrimental changes after heat exposure Kevlar/PBI which has low RPP value showed no high changes. In conclusion it could be confirmed that when total performance of a protective clothing is estimated retention capability of physical and mechanical properties after heat exposure as well as RPP value must be considered.
Radiant barrier systems(RES) constructed with low emissivity materials bounded by an open air space can be used to reduce the net radiation transfer between two surfaces. To analyze the heat transfer characteristics of the radiant barrier systems which consist of a single-glass and radiation barriers, a simple theoretical model based on energy balances was suggested. And the model was validated by means of the experimental results. Using a guarded hot box, the temperatures of layers in selected RES and energy use for each cases were measured. The results show that the model well explained the heat transfer characteristics of those RES. Also, the heat transfer coefficient correlations considering natural and forced convection heat transfer ware suggested. It is found that the heat transfer efficiency of a RBS with aluminium surface improved up to 66.6% over that of a single glazing system.
Most of the domestic residential buildings have used the traditional radiant heating system, circulating hot water through the cross-linked polyethylene(PE-X) pipe buried in the floor panel of the heating space. New type of the heating panel was recently developed using heat pipes with double wicks. Some experiments were carried out in this study to verify the thermal characteristics of this heating system at the unit heating space which surrounded by outer space whose temperature of air be maintained scheduled value with time. Through the various experiments with several parameters, such as flow rate, inlet and outlet temperatures of hot water and the heating duration and so on, we found that the floor heating system with heat pipes was able to reduce the pumping power for hot water circulation by 4~31% compared with the conventional panel heating system using PE-X pipe. These results could be used for optimal design and efficient operation of the heating system as well as improvement of thermal comfort.
PEM fuel cell produces electric power, water and heat by the electrochemical reaction of hydrogen and oxygen. The heating value is dependent on the molar enthalpy of vaporization of product water and the performance loss. In this paper, the heating value of fuel cell stack has been studied under various stack operating temperatures to achieve more efficient heat management. A technology using the molar enthalpy of vaporization of product water is suggested to reduce heat-up time during start-up of a fuel cell vehicle.
소방보호복은 고열유속에 의한 화상방지를 위해 3층 이상의 복합소재로 구성되어 있으며, 각 소재 사이는 공기 간극이 존재한다. 화재에 의한 고열유속 노출 시 공기 간극 내에서의 열전달은 대류와 복사에 의해 주로 발생하며, 그로 인해 간극의 크기에 따라서 비선형 특징의 열 저항 크기를 갖게 된다. 그러므로 본 연구에서는 보호복 소재 사이의 여러 가지 공기 간극(0~7 mm)에 대한 보호복의 열 보호성능을 자세히 파악하기 위한 실험을 수행하였다. 복사 열 유속 입사시에 시간에 따른 각 소재의 온도 변화뿐만 아니라, 열 보호성능을 가장 효과적으로 나타낼 수 있는 지표(Radiant Protective Performance, RPP) 값의 공기간극에 대한 변화 특성을 파악하였다. 공기간극이 증가할수록 단열효과가 커짐으로 인해 후면의 온도는 낮아지고, RPP는 커짐을 확인할 수 있었다. 특히 일정 열유속 조건에서 공기간극에 대한 RPP 값은 선형적인 특성을 나타내었고, 그러한 결과를 바탕으로 다양한 입사 열유속 및 공기 간극 조건에 대해 비교적 간단한 형태의 RPP 지표 예측 식을 제안하였고, 좋은 예측 결과를 얻을 수 있었다.
In order to monitor the impact of high temperature which is seen frequently with climate change, we investigated the monthly change in globe temperature, air temperature, mean radiant temperature and effective radiant heat flow, because the four well reflect thermal radiation from bio-meteorological aspect. Both globe temperature and air temperature showed an increasing trend every month. Compared to air temperature, globe temperature had a wider range of temperature change and was more influenced by meteorological element such as precipitation. Diurnal trends of air temperature, globe temperature and the difference between their temperature had the lowest value before the sunrise and the highest around $1300{\sim}1500$ LST, showing the typical diurnal trends. Globe temperature and the difference between their temperature had a sharp increase around $1000{\sim}1100$ LST, maintained high value until 1700 LST and then reclined, though varied by month. The difference between globe temperature and air temperature was highly dependent on the amount of precipitation and clouds. The duration in which globe temperature was higher than air temperature was the lowest in July. Therefore the amount of precipitation was the most affecting, followed by the amount of clouds and wind. In order to find out the diurnal trends of temperature in city center and city outskirts, we assumed the roof of a concrete build ing as a city center, and the grass-covered observatory of the Gimhae International Airport as city outskirts. The diurnal trends of temperature in the two sites showed a strong correlation. The highest and lowest temperature also had the same trend.
The purpose of this study was to analyze the difference of thermal sensation by radiant floor heating as ecological design element. The experimental investigations were carried out in climate chamber, and subjects were 34 college-age females in good health. The experimental variable was radiant heat by floor heating, and experimental controlled conditions were indoor temperature, relative humidity, and air velocity in climate chamber and clothing value and activity of subjects. The results are as follows. (1) Indoor temperature($21{\pm}0.5^{\circ}C$) in climate chamber were maintained as controlling. Clothing values of the subjects were controlled as average 0.73 clo. In the floor heating-off, globe temperature was average $23.2^{\circ}C$(22.4~24.1), but in the floor heating-on, globe temperature was average $24.8^{\circ}C$(23.0~25.5). (2) In the floor heating-off, thermal sensation rating was average -1.03(slightly cool), in the floor heating-on, thermal sensation rating was average +1.03(slightly warm). (3) There were the differences of thermal sensation by radiant floor heating although indoor temperatures were maintained in an equal state. (4) The thermal sensation rating was tending upward according as the globe temperature was getting higher.
Polymethyl methacrylate (PMMA), polycarbonate (PC), polyvinyl chloride (PVC), 그리고 polyacetal을 포함하는 일부 플라스틱류에 대한 연기특성을 조사하였다. 연기밀도는 ISO 5659-2의 기준에 의해 연기밀도시험기를 이용하여 정적인 연기 특성의 관련 값을 측정하였다. 또한 불꽃을 동반하는 연소와 불꽃을 동반하지 않는 연소를 구분하여 측정하였다. 불꽃방식의 복사열 50 kW/m2 의 조건하에서 연기의 최대비광학밀도(Dm) 측정값은 PMMA (401.26)가 최저로, PVC (1345.04)가 최대로 나타났다. 또한 비불꽃방식의 복사열 50 kW/m2 의 조건하에서 연기의 Dm 측정값은 PMMA (262.82) 가 최저로, PVC (1385.43)가 최대로 나타났다. 대상물의 연소 시 연기발생은 복사열 유속의 영향을 상당히 받으며, 탄화성 플라스틱은 연소 시 비탄화성 플라스틱보다 높은 연기 발생량을 나타내었다. 주 고분자 사슬에 방향족 그룹이 있는 폴리머는 열분해로 인해 다량의 숯이 생성되므로 다량의 연기를 발생시켰다.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.