• Title/Summary/Keyword: Radiant Temperature

Search Result 307, Processing Time 0.027 seconds

Unsteady Heat Transfer Analysis of Radiant Heating Panel (복사 난방 패널의 과도 열전달 해석)

  • Lee, T.W.;Kim, H.Y.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.4 no.3
    • /
    • pp.191-203
    • /
    • 1992
  • To analyze the unsteady heat transfer phenomena in radiant heating panel, a mathematical model was considered. Numerical analysis for solving the governing equations was conducted by using the finite difference method with boundary-fitted meshes. Transient temperature distributions and thermal responses in heating panel were obtained for various design parameters such as pipe pitches, pipe diameters and pipe depths. Experimental results were also obtained to verify the results of calculation.

  • PDF

Human Solar Heat Load and Thermal Comfort in an Outdoor Environment (건축외부공간에 있어서 인체의 일사열부하(日射熱負荷) 및 열적(熱的) 쾌적성(快適性)에 관한 실험적 연구)

  • Jeong, Chang-Won;Yoon, In
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.1 no.2
    • /
    • pp.65-74
    • /
    • 1998
  • The purpose of this paper is to investigate the mount of relief of human solar heat load and thermal comfort in outdoor environment in summer, Six different types of sites, T garden and its neighboring area in Japan, were selected as the experiment sites. The experiments were conducted from 22 to 29 August, 1994 to find the relationship between climatic conditions and human responses, Climatic conditions, subjects's thermal sensation and skin temperature were measured. Radiant heat exchange on the human body was estimated on the basis of the measured air and surface temperature and solar radiation. Thermal index Operative Temperature and New Effective Temperature was modified with the effect of the radiant heat exchange. Human thermal comfort and skin temperature is affected by the solar radiation and the sky factor in an outdoor environment. The effect of tree shade was verified on thermal comfort, The mount of relief of human solar heat load is relation to the existence of shade a solar radiation and the sky factor. The urban garden is one of the effective design element in an urban environmental planning.

  • PDF

Convergence Study due to the Configuration of Radiant Heat Panel of Automotive LED Heat Lamp (자동차 LED 전조등 방열판 형상에 따른 융합 연구)

  • Choi, Gye-Gwang;Cho, Jae-Ung
    • Journal of the Korea Convergence Society
    • /
    • v.8 no.3
    • /
    • pp.199-204
    • /
    • 2017
  • The Nowadays, LED head lamp has been used instead of halogen lamp at automotive head lamp. Inside this LED head lamp, there is a radiant heat panel which has the role to have the considerable influence upon LED life. As the radiant heat panel absorbs the heat from medium, the overheat of diode can prevented. in this study, the heat transfer and thermal stress are investigated according to the configuration of radiant heat panel. As the result of this study, the heat at model 1 decreases in comparison with model 2 and model 1 in design has the durability more than model 2. As the convergence technique is grafted on the design of radiant heat panel, the esthetic sense can be shown at the automotive head lamp.

A Study on the Temperature Characteristics and Flame Stabilization of Surface Combustor using the Metal Fiber (메탈화이버를 이용한 표면연소기의 화염안정화 및 온도특성에 관한 연구)

  • Lee, Jin-Seok;Lee, Young-Hoo;Yun, Bong-Seok;Lee, Do-Hyung
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.92-97
    • /
    • 2002
  • By changing the excess air ratio which affects strongly to the combustion characteristics, the flame stability range in the metal fiber burner were found and the range of the blue flame male and radiant mode were distinguished by direct photography. The results in our experiments for the flame stability zone were from a=1.4($354 KW/m^2$) to a=2.06($240 KW/m^2$), and then the blue flame mode zone was form a=1.87($266 KW/m^2$) to a=2.06($240 KW/m^2$) and the radiant mode one was form a=1.4($354 KW/m^2$) to a =1.78($278 KW/m^2$). And the flame was not fired when a is less than the lean condition a=2.45($202 KW/m^2$).

  • PDF

Comparison of Experimental and FDS Data for Calculating Heat-Affected Range in Forest Fires (산불 열영향 범위 산정을 위한 실험 및 FDS 데이터 비교)

  • Kim, H.S.;Kang, Y.J.;Kim, J.H.;Kim, K.H.;Lee, B.D.;Kim, Jeong Hun
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.4
    • /
    • pp.91-96
    • /
    • 2014
  • This research deals with the combustion experiment of pine trees, which are the most representative species in Korea. Experimental data are compared with theoretical ones using Fire Simulation Program(FDS). It is considered that horizontal/vertical temperature distribution and radiant heat influence on adjacent areas in fire scenes. The linear function for separation distance to temperature was drawn by applying Stefan-Boltzmann's law; $y=112.13133{\times}({\sigma}T^4)^{-0.52916}$ for calculating the separation distance. In combustion experiment, the radiant heat came to $1.4{\sim}1.5kW/m^2$ in case of the separation distance by one meter. The numerical values mean that human body show the critical level of pain after one minute without a protective equipment.

The Next Generation Apartment Model Far Infrared Rays Radiant Heater using Quasi-Resonant Soft Switching PWM Inverter

  • Kwon, Soon-Kurl;Mun, Sang-Pil
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.11
    • /
    • pp.15-22
    • /
    • 2008
  • This paper presents an innovative prototype of a new conceptual electromagnetic induction heated type far infrared rays radiant heating appliance using the voltage-fed quasi-resonant ZVS-PWM high frequency inverter using IGBTs for food cooking and processing which operates under a constant frequency variable power regulation scheme. This power electronic appliance with soft switching high frequency inverter using IGBTs has attracted special interest from some advantageous view points of safety, cleanliness, compactness and rapid temperature response, which is more suitable for consumer power electronics applications.

The Effects of Hot Water Supply on Energy Consumption for Floor Radiant Heating System (바닥복사 난방시스템의 공급온수특성에 따른 에너지 소비특성 연구)

  • Song, Jae-Yeob;Ahn, Byung-Cheon
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.15 no.4
    • /
    • pp.32-38
    • /
    • 2019
  • In this study, the effect of hot water supply flow rates on energy consumption for radiant floor heating system in apartment were researched by computer simulation. The parametric study of different hot water supply flow rates was done with regard to energy performance and control characteristics, respectively. Also the effect of different hot water supply flow rates on the hot water supply temperatures is studied. As a result, energy consumption were reduced but the response time is increased by reducing the supply flow rate. And energy consumption can be saved by adjusting the hot water supply temperatures with different supply flow rates.

Visible Project Area for Korean Child (Six Years Old) in Radiant Enclosures (한국 어린이를 위한 복사 공간에서의 투사 면적에 관한 연구)

  • 손철수;최민권
    • Journal of the Korean housing association
    • /
    • v.11 no.4
    • /
    • pp.77-84
    • /
    • 2000
  • The purpose of this paper is to find a visible project area for an average six year old Korean child in radiant enclosures having standing pose. The results using this method will be necessary to find effective radiation area, effective radiation area factor, form factor, and mean radiant temperature for an average six years old Korean child consists of 3012 triangles. The methods to find visible project area of an average six years old Korean at arbitrary view point will be presented. The visible project area for Korean child is needed for evaluating thermal comfort for six years old Korean child. The biggest visible project area of an average six years old Korean is $\textrm{cm}^2$$2.061.0\textrm{cm}^2$ at the view point of alfa 0.0 degree and beta 0.0 degree, and the smallest visible real area of an average six years old Korean is $567.1\textrm{cm}^2$ at the view point of alfa 15.0 degree and beta 90.0 degree.

  • PDF

A Study on the Operational Strategies for Outdoor Air Temperature Change Characteristics in a Radiant Floor Heating System (바닥난방시스템의 외기온도 변화특성을 고려한 운전방안에 관한 연구)

  • Ahn, Byung-Cheon;Song, Jae-Yeob
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.12
    • /
    • pp.685-692
    • /
    • 2013
  • In this study, the control characteristics and effects of heating control methods on the heating performance and energy consumption of a hot-water heating control system of a residential apartment were researched by simulation and experiment. The purpose of this study is to evaluate operational strategies for improving an indoor thermal environment and reducing f energy consumption in the radiant floor heating system of a residential apartment.