• Title/Summary/Keyword: Radial bearing

Search Result 247, Processing Time 0.019 seconds

Lateral Arm Free Flap for Small Sized Diabetic Foot Ulcer around Toes (족지 주위의 작은 크기의 당뇨 족부 궤양에 대한 외측 상완 유리 피판술)

  • Jung, Heun-Guyn;So, Gwang-Young;Kuk, Woo-Jong;Kim, Hee-Dong
    • Archives of Reconstructive Microsurgery
    • /
    • v.17 no.1
    • /
    • pp.28-35
    • /
    • 2008
  • The purpose of this study was to present the clinical analysis of the results of lateral arm free flap for small sized and infected diabetic foot ulcer around toes. From May 2006 to December 2007, Seven patients were included in our study. Average age was 52.8 years, six were males and one was female. All had infected diabetic foot ulcer and had exposures of bone or tendon structures. Ulcers were located around great toe in four patients, 4th toe in one and 5th toe in two. Three patients had osteomyelitis of metatarsal or phalanx. After appropriate control of infection by serial wound debridement and intravenous antibiotics, lateral arm flap was applied to cover remained soft tissue defects. Posterior radial collateral artery of lateral arm flap was reanastomosed to dorsalis pedis artery of recipient foot by end to side technique in all cases in order to preserve already compromised artery of diabetic foot. All flaps were designed over lateral epicondyle to get longer pedicle and averaged pedicle length was 8 cm. Two cases were used as a sensate flap to achieve protective sensation of foot. All flaps survived and provided satisfactory coverage of soft tissue defects on diabetc foot ulcers. All patients could achieve full weight-bearing ambulation. No patients has had recurrence of infection, ulceration and further toe amputations. There were three complications, a delayed wound healing of flap with surrounding tissue, a partial peripheral loss of flap and a numbness of forearm below donor site. All patients were satisfied with their clinical results, especially preserving their toes and could return to the previous activity levels. Lateral arm free flap could be recommend for infected diabetic foot ulcers around toes, to preserve toes, coverage of soft tissue defect and control of infection with low donor site morbidity.

  • PDF

Test Rig Development for Identification of Rotordynamic Force Coefficients of Squeeze Film Dampers in Automotive Turbocharger Bearing Systems (자동차 터보차저 베어링 시스템에 적용되는 스퀴즈 필름 댐퍼의 동적계수 측정을 위한 실험장치 개발)

  • Hwang, Jisu;Ryu, Keun;Jeung, Sung-Hwa
    • Tribology and Lubricants
    • /
    • v.34 no.1
    • /
    • pp.33-41
    • /
    • 2018
  • This paper describes a new test rig for identification of rotordynamic force coefficients of squeeze film dampers (SFDs) in automotive turbochargers (TCs). Prior studies have mainly concentrated on relatively large-sized SFDs used in aircraft engines, turbocompressors, and turbopumps. The main objective of the current study is to propose a test rig for identification of dynamic force coefficients of small-sized SFDs (a journal diameter of ~11 mm). The current test rig consists of a journal, a SFD cartridge, four support rods, an upper structure, a data acquisition (DAQ) system, and an oil circulation unit. The annular gaps between the journal outer surface and SFD cartridge inner surface create SFD film lands. The damper has two parallel film lands separated by a central groove, having an axial length and depth of 3 mm. Each film land has a length of 4 mm with a $40{\mu}m$ radial clearance. The static load and dynamic impact tests identify the structural characteristics (i.e., stiffness and natural frequency) of the journal and assembled test rig. The measurements show good agreement with predictions. The SFD performance data from this test rig will be used to develop innovative TC rotor systems with improved NVH and reliability characteristics incorporating advanced SFD technology.

LEU+ loaded APR1400 using accident tolerant fuel cladding for 24-month two-batch fuel management scheme

  • Husam Khalefih;Taesuk Oh;Yunseok Jeong;Yonghee Kim
    • Nuclear Engineering and Technology
    • /
    • v.55 no.7
    • /
    • pp.2578-2590
    • /
    • 2023
  • In this work, a 24-month two-batch fuel management strategy for the APR1400 using LEU + has been investigated, where enrichments of 5.9 and 5.2 w/o are utilized in lieu of the conventional 4-5 w/o UO2 fuel. In addition, an Accident Tolerant Fuel (ATF) clad based on the swaging technology is applied to APR1400 fuel assemblies. In this special ATF clad design, both outer and inner SS316 layers protect the conventional zircaloy clad. Erbia (Er2O3) is introduced as a burnable absorber with two-fold goals to lower the critical boron concentration in the long-cycle LEU + loaded core as well as to handle the LEU + fuel in the existing front-end fuel facilities without renewing the license. Two types of fuel assemblies with different loading of gadolinia (Gd2O3) are considered to control both the reactivity and the core radial power distribution. The erbia burnable absorber is uniformly admixed with UO2 in all fuel pins except for the gadolinia-bearing ones. In this study, two core designs were devised with different erbia loading, and core performance and safety parameters were evaluated for each case in comparison with a core design without any burnable absorbers. The core analysis was done using the two-step method. First, cross-sections are generated by the SERPENT 2 Monte Carlo code, and the 3-D neutronic analysis is performed with an in-house multi-physics nodal code KANT.

The Heel Reconstruction by Microsurgery (미세수술을 이용한 발뒤꿈치 재건)

  • Lee, Kwang-Suk;Huh, Chang-Young;Kim, Hak-Yoon;Suh, Jeong-Dae
    • Archives of Reconstructive Microsurgery
    • /
    • v.3 no.1
    • /
    • pp.24-31
    • /
    • 1994
  • The heel, with its specialized fat for shock absorption at heel strike and large surface area for balance and weight bearing, is a important component of normal ambulation. Despite of distinguished improvement in the field of microsurgical free flaps, the choice of reconstruction of the heel has been remained controversial. We reviewed 22 cases of the heel reconstruction using vascularized free flaps from January, 1980 through May, 1993 at the Department of Orthopedic Surgery of Korea University Hospital. The results were as follows: 1. The etiology was traumatic in 21 cases, and chronic ulceration due to burn in 1. 2. The arteries used in free flaps were 11 dorsalis pedis arteries, 2 deep circumflex iliac arteries, 2 supeficial iliac arteries, 2 branches of lateral femoral circumflex iliac arteries, 2 radial arteries, and 3 thorcodorsal arteries. 3. The mean size of the vascularized bone was $4.5cm{\times}3.5cm$, and that of skin flap was $12.1cm{\times}9.2cm$. 4. Of the 22 cases, 19 had a successful outcome and 3 in failure, the causes of failure were thrombosis and infection.

  • PDF

Structural Design and Analysis of a Hydraulic Coiling Arm for Offshore Wind-turbine Submarine Cable (해상풍력 해저케이블 하역용 유압식 코일링 암 구조설계 및 해석)

  • Kim, Myung-Hwan;Kim, Dong-Hyun;Oh, Min-Woo
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.26 no.1
    • /
    • pp.1-7
    • /
    • 2013
  • Structural design and analysis of a coiling arm unloading machine for submarine cable have been originally conducted in this study. Three-dimensional CAD modeling process is practically applied for the structural design in detail. Finite element method(FEM) and multi-body dynamics(MBD) analyses are also used to verify the safety and required motions of the designed coiling arm structure. The effective moving functions of the designed coiling arm with respect to rotational and radial motions are achieved by adopting bearing-roller mechanical parts and hydraulic system. Critical design loading conditions due to its self weight, carrying cables, offshore wind, and hydraulic system over operation conditions are considered for the present structural analyses. In addition, possible inclined ground conditions for the installation of the designed coiling arm are also considered to verify overturn stability. The present hydraulic type coiling arm system is originally designed and developed in this study. The developed coiling arm has been installed at a harbor, successfully tested its operational functions, and finished practical unloading mission of the submarine cable.

Arthroscopic Reduction of Subluxed Medial Meniscus using Suture Anchor for Restoration of Hoop Stress - Technical Note - (버팀테응력 회복을 위한 아탈구된 내측 반월상 연골의 Suture anchor를 이용한 정복술 - 술기 보고 -)

  • Kim, Jaw-Hwa;Lee, Yoon-Seok;Kim, Chul;Han, Seung-Chul
    • Journal of the Korean Arthroscopy Society
    • /
    • v.13 no.3
    • /
    • pp.280-284
    • /
    • 2009
  • Purpose: The authors introduce a new technique of arthroscopic reduction of subluxed medial meniscus using suture anchor for the restoration of hoop stress. Operative Technique: Anterolateral, anteromedial, and medial midpatellar arthroscopic portal are used. Arthroscope was inserted through anterolateral portal. Through the scope, we confirmed subluxation of medial meniscus. Transection of menisci including radial and root tear were excluded. We released the anterior horn of medial meniscus through anteromedial and burred the future insertion site of suture anchor. After inserting suture anchor through medial midpatellar portal, we used 90 degree suture hook and no.2 Nylon to retrieve the suture of inserted anchor. We tied the suture by sliding knot-tying method. Weight bearing was limited for 6 weeks postoperatively. Conclusion: Arthroscopic retightening of medial meniscus is less invasive, conserving and progressed method for subluxed meniscus.

  • PDF

Anatomical Studies on Tumorous Tissue Formed in a Stem of Ailanthus altissima Swingle by Artificial Banding and Its Subsequent Removing Treatment -Characters of Individual Elements- (인위적(人爲的)인 밴드결체(結締) 및 해체처리(解締處理)로 형성(形成)된 가죽나무(Ailanthus altissima Swingle) 수간(樹幹)의 종양조직(腫瘍組織)에 관한 해부학적(解剖學的) 연구(硏究) -조직(組織) 구성세포(構成細胞)의 특성(特性)-)

  • Eom, Young Geun;Lee, Phil Woo
    • Journal of Korean Society of Forest Science
    • /
    • v.78 no.3
    • /
    • pp.287-301
    • /
    • 1989
  • A tree of Ailanthus altissima Swingle was fastened with a plastic band, 19mm wide, around the stem 180cm above ground level and was left to grow under this condition for one year, By removal of this band the tumorous tissue gradually developed and the tree bearing distinct tumorous tissue, an overgrowth surrounding the stem, was harvested two years after the band removal. For the investigation of this tumorous part and its comparison with adjacent normal parts in the anatomical features of individual elements, the tumorous part and parts directly and 40cm above and below the tumorous part were obtained from the tree. The tumor wood having remarkably wider growth increment occurred in the 3rd growth ring the first year after removal of the fastened band, and the barrier zone which delimited the discolored wood from the normal-colored wood inwards appeared u1 the intra-2nd growth ring produced during the fastened period in the tumorous part and the false ring-like zones equivalent to barrier Zone were shown in the normal-colored 2nd growth rings of the parts directly and 40cm above and below the tumorous part, as well. The tumor wood, the 3rd growth ring, and proportion of the 2nd growth ring formed after barrier zone in the tumorous part shared common characteristics in the irregular growth ring boundary, misshapen and shorter individual fibers and vessel elements, and large ray widths and heights. The springwood pores were smaller in diameter in the tumor wood, and the larger radial and smaller tangential diameters of summerwood solitary pores and individual pores consisting of pore multiples in proportion of the 2nd growth ring formed after the barrier zone were transformed into near-isodiametric in the tumor wood, the 3rd growth ring, in the tumorous part. Only in proportion of the 2nd growth ring formed after the barrier zone were transformed into near-isodiametric in the tumor wood, the 3rd growth ring, in the tumorous part, ray densities greatly increased. And the massive tumor wood was caused not by cell size but by cell number because the radial and tangential diameters of fibers in the tumor wood, the 3rd growth ring, in the tumorous part were not sufficiently different from those in the same aged growth rings of the directly and 40cm above and below the tumorous part.

  • PDF