• 제목/요약/키워드: Radial Distribution System

검색결과 238건 처리시간 0.025초

분산 전원의 고립 운전 진단 알고리즘 개발 (Development of a Islanding Protection Algorithm for Distributed Resources)

  • 장성일;박제영;김광호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 B
    • /
    • pp.1287-1289
    • /
    • 2001
  • This paper presents the logic based islanding protection algorithm for distributed resources(DR) which are interconnected with distribution network. Due to the negative impacts from islanding operations of DR on protection, operation and management of distribution system, it is necessary to effectively detect the islanding operations of DR and disconnect it from distribution network rapidly. Generally, it is difficult to detect islanding operation by monitoring only one system parameter. The proposed islanding protection algorithm utilizes multi-criteria, voltage variation, phase displacement frequency variation, the variation of total harmonic distortion(THD) of current; therefore it effectively detects island operation of DR unit. We also verified the efficiency of the proposed algorithm using the radial distribution network of IEEE 34 bus model.

  • PDF

배전계통에서 손실 최소화를 위한 유전자 알고리즘의 적용 (Application of Genetic Algorithm for Loss Minimization in Distribution Systems)

  • 전영재;김훈;이승윤;손학식;박성옥;김재철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 A
    • /
    • pp.156-158
    • /
    • 2000
  • This paper presents a efficient algorithm for loss reduction of distribution system by automatic sectionalizing switch operation in distribution systems of radial type. To apply genetic algorithm to reconfiguration of distribution system, in this paper we propose the string type and efficient reconfiguration procedure. We also discuss the more elaborate search techniques of solution space as well as the simple genetic algorithm. The experimental results show that the proposed genetic algorithm have the ability to search a good solution.

  • PDF

반경방향 착자형과 Halbach 배열형 영구자석 회전자를 갖는 고속 슬롯리스 기기의 공극자속밀도 특성 비교 (Comparison on the Airgap Flux Density of High-Speed Slotless Machines with Radial Magnetization and Halbach Array PM Rotor)

  • 장석명;정상섭;류동완
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제50권7호
    • /
    • pp.315-322
    • /
    • 2001
  • High speed brushless permanent magnet(PM) machines need a key technology to minimize the iron core losses in stator and the eddy current losses in the retained sleeve and magnets caused by slotting harmonics. Thus, slotless or iron-coreless brushless PM machines have been applied for a very high rotational speed and/or the ripple-free torque. Unfortunately, slotless or coreless PM machines have lower open-circuit field than slotted and/or iron-cored types, which cause to reduce power density. Fortunately, Halbach array can generate the strong magnetic field systems without additional magnetic materials. In this paper, the 4-pole Halbach array is applied to the high speed machine and is compared with the radial magnetized PM array in field system. The iron-/air-cored stator of PM machine is constructed with/without winding slots. Open circuit magnetic fields of each type are presented from the analytical method and finite element method. Consequently, it is confirmed that the Halbach array field system with slotless stator is more suitable to the high speed motor because it has high flux density, sinusoidal flux distribution than others.

  • PDF

간헐적인 연료분무의 유동특성에 관한 연구 (A Study on the Flow Characteristics of an Intermittent Fuel Spray)

  • 김원태;강신재
    • 대한기계학회논문집B
    • /
    • 제21권9호
    • /
    • pp.1198-1206
    • /
    • 1997
  • The flow characteristics of an intermittent fuel injection into a stationary ambient air were investigated using gasoline. The measurements were made by two-channel, air cooling type Phase Doppler Anemometer(PDA) system (DANTEC, 750 MW). And a pintle type injector of MPI (Multi-point Port Injection) system was utilized as a fuel injector. The PDA receiver optic was set up in a 60.deg. C forward scatter arrangement to obtain the optimum scattering signal of fuel droplets. The data were obtained by synchronizing PDA system with the fuel injection period, and the axial and radial velocity and turbulent components of fuel droplets were mainly measured for the analysis of temporal and spatial distribution depending upon the fuel injection pressures.

수정블럭 모델 법에 의한 배전계통의 최적운용에 관한 연구 (A study on the Optimal Operation of Distirbution System Using the Modified Block Model Method)

  • 송길영;홍상은;김재영
    • 대한전기학회논문지
    • /
    • 제36권4호
    • /
    • pp.231-239
    • /
    • 1987
  • Distribution system is one of large and complicated sytem, consisted of a great number of components. Therefore efficient operation based on precise analysis and computation methods is indispensable accommodating growing loads. This paper describes an optimal operation problem to relieve overload flow in radial distribution systems by using modified block model. The problem is formulated as a network problem of synthesizing the optimal spanning tree in a graph, branch and bound method is used for the optimization. Especially modified block model proposed in this paper is validated more practical than conventional model. These methods can be applied to two types of distribution system problems such as, 1) planning problem to check the capability of relieving overload at normal rating, 2) emergency operation problem to determine switching scheme for minimizing customer loads affected by a fault. Examples of application to these problems are discussed.

  • PDF

최적 재폐로방식 선정에 관한 연구 (A Study on the Determination of Optimal Auto-reclosing)

  • 김일동;한경남;임성정;김재철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 D
    • /
    • pp.861-863
    • /
    • 1997
  • This paper presents a reliability and power quality taken account of the reclosing scheme on the power distribution system. To determine the optimal reclosing scheme, the simple radial distribution system is modelled, and analyzes quantitatively the effect of customer's load to the number of reclosing. The result of the analysis shows that the determined reclosing scheme can satisfy both the reliability and the power quality in the power distribution system.

  • PDF

배전계통의 부하평형을 고려한 고속 계통구성방법 (A Fast Configuration Method for Load Balancing in Distribution System)

  • 남기영;최상봉;정성환;류희석;김호용
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 A
    • /
    • pp.381-383
    • /
    • 2003
  • The authors have developed a solution method based on the incremental algorithm. The optimal load balance between feeders is found through the incremental algorithm with allowing the loop configuration. Therefore loops can be configured in the resulting configuration, and then we must eliminate all loops to satisfy radiality of distribution system because the distribution system is operated under radial status. But the optimal load balance through incremental algorithm is deteriorated when the loops are eliminated. In this paper, authors propose a new method which is to improve the searching procedure of path in the incremental algorithm, that is, so as not to make loop in the path configuration.

  • PDF

향후 신뢰도 목표를 만족하는 개폐기 설치 기준 제시 (The Switch Installation Criteria For Satisfying Future Reliability Goal)

  • 조남훈;오정환;하복남;이흥호
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제51권9호
    • /
    • pp.433-440
    • /
    • 2002
  • The addition of switches to a distribution feeder does, in general, increase reliability by decreasing the duration of the outage of many to the customers on the feeder. To cover its service area so that feeder-level delivery reaches sufficiently close to all customers, feeders typically split their routes many times, in what is often called a lateral feeder. It is interesting to note, however, that the effectiveness of a switch is very much dependent on the types of lateral feeder. The types of lateral are classified into two types. The first is loop lateral feeder that can connect its load to an adjacent feeder through a tie line in case that a fault occurs in its feeder and it is laid out so that every feeder has complete fault backup through re-switching of its loads to other sources like a main feeder The second is the radial lateral feeder cannot connect its load to an adjacent line, no provision is made for contingency backup of feeders. There are no other circuits in the radial lateral feeder form which to restore power. In this study, we evaluate the effectiveness of a switch installation between on the radial and loop lateral feeders to increase reliability by decreasing the duration of the outage. These results can help power utility to design the switch layouts on the radial and loop lateral feeder system.

2차 공기 주입 조건 변화에 따른 소형 소각로 내부의 유동장 분석 (Analysis of the Gas Flow Field of Primary Combustion Chamber with the Conditions of Secondary Air Injection)

  • 최병대;김성준
    • 산업기술연구
    • /
    • 제22권A호
    • /
    • pp.9-17
    • /
    • 2002
  • This analysis is aimed to find out how the conditions of secondary air injection affects the residence time and the turbulence energy of flue gas and flow field in a small incinerator. A commercial code, PHOENICS, is used to simulate the flow field of an Incinerator. The computational grid system is constructed in a cartesian coordinate system In this numerical experiment, an independent numerical variable is the conditions of secondary air injection and dependants are the residence time of flue gas and the mean value of turbulence energy in a primary combustion chamber. The flow field and the distribution of turbulence energy are analysed to evaluate the residence time of flue gas and the turbulence energy The computational results say that the tangential injection of secondary air make the residence time much longer than the radial injection and that the radial injection of secondary make turbulence much stronger than the tangential injection.

  • PDF

Analytical and sensitivity approaches for the sizing and placement of single DG in radial system

  • Bindumol, E.K.;Babu, C.A.
    • Advances in Energy Research
    • /
    • 제4권2호
    • /
    • pp.163-176
    • /
    • 2016
  • Rapid depletion of fossil based oil, coal and gas reserves and its greater demand day by day necessitates the search for other alternatives. Severe environmental impacts caused by the fossil fire based power plants and the escalating fuel costs are the major challenges faced by the electricity supply industry. Integration of Distributed Generators (DG) especially, wind and solar systems to the grid has been steadily increasing due to the concern of clean environment. This paper focuses on a new simple and fast load flow algorithm named Backward Forward Sweep Algorithm (BFSA) for finding the voltage profile and power losses with the integration of various sizes of DG at different locations. Genetic Algorithm (GA) based BFSA is adopted in finding the optimal location and sizing of DG to attain an improved voltage profile and considerable reduced power loss. Simulation results show that the proposed algorithm is more efficient in finding the optimal location and sizing of DG in 15-bus radial distribution system (RDS).The authenticity of the placement of optimized DG is assured with other DG placement techniques.