• Title/Summary/Keyword: Radial Distribution System

Search Result 238, Processing Time 0.026 seconds

A Study on the Estimating Locations of Faults on Distribution Power Systems (배전계통 고장위치 검출방법에 관한 연구)

  • Kim Mi-Young;Oh Yong-Taek;Rho Dae-Seok
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.12
    • /
    • pp.670-677
    • /
    • 2004
  • The Conventional approach for estimating the locations of transmission line shunt faults has been to measure the apparent impedance to the fault from a line terminal and to convert the reactive component of the impedance to line length. But, these methods do not adequately address the problems associated with the fault location on distribution systems. This thesis presents a technique that estimates the location of shunt fault on a radial distribution system that has several single and multiphase laterals. Tapped loads and non-homogenity of the distribution system are take into account. The developed technique, which can handle shunt faults was tested to evaluate its suitability. Results from computer simulation of faults on a model of a 25KV distribution lines like real system are presented. The results approved that the proposed technique works well for estimating the locations of the distribution line shunt faults.

The Relationship Between Tree Radial Growth and Topographic and Climatic Factors in Red Pine and Oak in Central Regions of Korea (중부지방 소나무와 참나무류의 반경생장량과 지형, 기후 인자의 관계)

  • Byun, Jae-Gyun;Lee, Woo-Kyun;Nor, Dae-Kyun;Kim, Sung-Ho;Choi, Jung-Kee;Lee, Young-Jin
    • Journal of Korean Society of Forest Science
    • /
    • v.99 no.6
    • /
    • pp.908-913
    • /
    • 2010
  • This study analyzed the impact of climatic and topographic factors on tree radial growth of Pinus densiflora and Quercus spp. in central regions of Korea. To find the relationship between annual tree radial growth and climatic factors, we took the core samples from individual trees and measured the tree radial width. On the assumption that the tree radial growth is related to the tree age, we estimated the radial growth by the tree age as an independent variable. Also, we estimated the standard growth, defined as the radial growth of trees aged 30. As results, we found the spatial auto-correlation in the radial growth of the red pine. Moreover, we also found the relationships between climatic and topographic and the standard growth using the GAM (Generalized Additive Model). Increase of temperature has negative impacts on the radial growth of Pinus densiflora, while it has positive impacts on the radial growth of Quercus spp.. On the other hands, increase of precipitation has negative impacts on the radial growth of both species. Lastly, we predicted the spatial distribution changes of Pinus densiflora and Quercus spp. using the temperature increase scenario and the Geographic Information System (GIS) based forest type map. We could predict that Pinus densiflora is more vulnerable than Quercus spp. to climate change so that the habitats of Pinus densiflora will be gradually changed to the habitats of Quercus spp. in eastern coastal and southern regions of Korea after 60 years.

A study of Optimal Reconfiguration in Distribution Power System using Initial Operating Point (초기 운전점 선정을 통한 배전계통 최적 재구성에 관한 연구)

  • Seo, Gyu-Seok;Kim, Jung-Nyun;Baek, Young-Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.3
    • /
    • pp.451-456
    • /
    • 2007
  • This paper presents a problem that reconfigure distribution power system using branch exchange method. Optimal reconfiguration problem calculates line loss, voltage condition about system states of all situations that become different according to line On/off status, and search for optimum composition of these. However, result is difficult to be calculated fast. Because radiated operation condition of system is satisfied using many connection and sectionalize switches in the distribution power system. Therefore, in this paper, optimization method for reducing system total loss and satisfying operating condition of radial and constraints condition of voltage is proposed using the fastest branch exchange. And optimal solution at branch exchange algorithm can be wrong estimated to local optimal solution according to initial operating state. Considering this particular, an initial operating point algorithm is added and this paper showed that optimal solution arrives at global optimal solution.

Advanced Protective Coordination Schemes of Utility Interconnected Cogeneration Systems (배전계통에 연계된 열병합발전 시스템의 개선된 보호협조 방안에 관한 연구)

  • Choe, Jun-Ho;Jeong, Seong-Gyo;Chu, Dong-Uk;Kim, Nak-Gyeong;Son, Hak-Sik;Kim, Jae-Cheol
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.49 no.6
    • /
    • pp.280-288
    • /
    • 2000
  • Recently, there has been growing interest in utilizing cogeneration(COGN) systems with a high-energy efficiency due to the increasing energy consumption and the lacking of energy resource. But an insertion of COGN system to existing power distribution system can cause several problems such as voltage variations, harmonics, protective coordination, increasing fault current etc, because of reverse power of COGN, especially in protective coordination. A study on a proper coordination with existing one is being required. The existing power distribution system is operated with radial type by one source and protection system is composed based on unidirectional power source. But an Insertion of COGN system to power distribution system change existing unidirectional power source system to bidirectional power source. Therefore, investigation to cover whole field of power distribution system must be accomplished such as changing of protection devices rating by increasing fault current, reevaluation of protective coordination. In this paper, simulation using PSCAD/EMTDC was accomplished to analyze effect of COGIN on distribution fault current. Also, the existing protection system of 22.9[kV] power distribution system and customers protection system to protect of COGIN was analyzed and the study on protective coordination between of two protection system accomplished.

  • PDF

A Study on the Reliability of Electric Power Distribution System (배전시스템의 신뢰도에 관한 연구)

  • 김경철;최홍규;원진희
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.3
    • /
    • pp.61-66
    • /
    • 2002
  • Electric power distribution networks are prime examples of systems where a very high degree of reliability is expected. Reliability is the probability of a device or system performing its function adequately for the period of time intended and intented operating conditions intented. This paper shows that a better meshed distribution configuration over the case study of radial configuration distribution system was selected by comparing the indices obtained from EDSA\`s reliability worth assessment of distribution systems program.

A Study on the Three Dimensional Statistical Turbulent Flow Characteristics Around a Small-Sized Axial Fan for Refrigerator (냉장고용 소형 축류홴의 통계학적 3차원 난류유동 특성에 관한 연구)

  • Kim, Jang-Gwon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.6
    • /
    • pp.819-828
    • /
    • 2001
  • The operating point of a small-sized axial fan is strongly dependent upon the system resistance. Therefore, the turbulent flow characteristics around a small-sized axial fan may change significantly according to the operating point. This study represents three-dimensional turbulent flow characteristics around a small-sized axial fan measured at the ideal design point $\phi$=0.25, which is equivalent to the maximum total efficiency point, by using three dimensional fiber-optic type LDA system. This LDA system is composed of a 5 W Argon-ion laser, two optics in back-scatter mode, three BSAs, a PC, and a three-dimensional automatic traversing system. A kind of paraffin fluid is used to supply particles by means of fog generator. Mean velocity profiles downstream of a small-sized axial fan along the radial distance show that the streamwise and the tangential components exist in a predominant manner, while the radial component has a small scale distribution and shows the inflection which its flow direction is inward or outward. Moreover, the turbulent intensity profiles show that the radial component exists the most greatly among turbulent energies.

Characteristics of the Droplet Behavior in the Overlap Region of Twin Spray and in Single Spray (이중분무의 중첩영역과 단일분무에서 액적의 거동 특성)

  • Jung, Ji-Won;Cha, Keun-Jong;Kim, Duck-Jool
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.10
    • /
    • pp.1300-1308
    • /
    • 2000
  • The objectives of this study was to investigate the spray characteristics of single spray and twin spray in the overlap region such as mean axial velocity, mean radial velocity, mean droplet size and probability density function of droplet size. A phase doppler anemometer was used as the measurement system for droplet size and velocity. In case of single spray, injection pressure was varied from 0.2MPa to 0.7MPa. Mean axial velocity, mean radial velocity and droplet size were decreased as the distance below nozzle tip was increased. In case of twin spray, the spray characteristics were measured by varying the distance between two nozzles from 127mm to 155mm. In the overlap region, the boundary of the overlap region was determined by obtaining the distribution of mean axial and radial velocity. Droplet size was increased as the distance from nozzle tip was increased. It was found that the distribution of droplet size for twin spray in the overlap region was different to single spray.

WASHINGTON PHOTOMETRY OF THE GLOBULAR CLUSTERS IN THE VIRGO GIANT ELLIPTICAL GALAXY M86

  • Park, Hong-Soo
    • Journal of The Korean Astronomical Society
    • /
    • v.45 no.3
    • /
    • pp.71-84
    • /
    • 2012
  • We present a photometric study of the globular clusters (GCs) in the Virgo giant elliptical galaxy M86 based on Washington $CT_1$ images. The colors of the GCs in M86 show a bimodal distribution with a blue peak at ($C-T_1$) = 1.30 and a red peak at ($C-T_1$) = 1.72. The spatial distribution of the red GCs is elongated similar to that of the stellar halo, while that of the blue GCs is roughly circular. The radial number density profile of the blue GCs is more extended than that of the red GCs. The radial number density profile of the red GCs is consistent with the surface brightness profile of the M86 stellar halo. The GC system has a negative radial color gradient, which is mainly due to the number ratio of the blue GCs to the red GCs increasing as galactocentric radius increases. The bright blue GCs in the outer region of M86 show a blue tilt: the brighter they are, the redder their mean colors get. These results are discussed in comparison with other Virgo giant elliptical galaxies.

A Study on the Effective Coordination Scheme of Recloser for the Conventional Distribution System Interconnected Dispersed Generation (배전계통에 분산전원 연계시 기존 배전 계통측의 효과적인 리클로저 보호협조 연구)

  • Jung, Seung-Bock;Kim, Jae-Chul;Moon, Jong-Fil;Yun, Sang-Yun;Choi, Joon-Ho;Bae, Joo-Chun
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.533-535
    • /
    • 2002
  • In Korea, power requirement has been increasing. But the large generation unit is hardly installed because of economic and environment problem. Therefore, the concern of dispersed generation system(DGS) is growing. The power distribution system is generally operated with radial type. The protection system is composed of one directive source. But power distribution system inserted DGS changes it to two directive source system. Therefore, the insertion of DGS has the problem of protection coordination. In this paper, we argue fault current affected by interconnected DGS. We analyze fault current flow affected by DGS placement. Then, we find protective coordination problem. Consequently, we study advance point for protection scheme of power system interconnected DGS.

  • PDF

A Statistical Approaching about Characteristics of Galactic Open Clusters from the perspective of Blue Straggler Formation Environments

  • Lee, Hyun-Uk;Chang, Heon-Young
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.41 no.2
    • /
    • pp.59.1-59.1
    • /
    • 2016
  • Blue Straggler Stars(BSS) affect their host star cluster in various parameters like color, dynamics, etc. For this reason, it is important to know how to relate BSS frequency and evolution of their host stellar system. To statistical study about global properties of open clusters as the environments of BSS formation, we use three catalogues - (1) two galactic open clusters catalogues including BSS candidate, (2) Milky Way Star Cluster (MWSC) survey data. Then, we compare with the data of two BSS catalogues for test of the result of Marchi et al. 2006. We also investigate the radial mass distribution in open cluster, because it is possible that changing the gradient of radial mass distribution cause increasing the BSS frequency. When we group the open cluster into having BSS or not and other criteria, the groups show slight discrepancies, but we show some important results.

  • PDF