• Title/Summary/Keyword: Radial Distribution System

Search Result 238, Processing Time 0.027 seconds

The Spray Characterization Using Planar Imaging Technique (평면 이미지 기법을 이용한 분무 특성 해석)

  • Lee, Kyung-Jin;Jung, Ki-Hoon;Yoon, Young-Bin;Jeong, Kyung-Seok;Jeung, In-Seuck
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.1
    • /
    • pp.93-101
    • /
    • 2000
  • The characteristics of spray nozzle have been quantified with the measurement of fluorescence and Mie scattering images. To correct the attenuation of the incident light sheet, a sequential double-pass light sheet system and the geometrical averaging of two images was implemented. Quantitative mass flux distribution of spray was obtained from fluorescence image. 3-D image is reconstructed using 2-D radial images. Sauter mean diameter (SMD) distribution was determined using the ratio of fluorescence signal intensity and Mie scattering signal intensity and the values were quantified with PDP A data. The measurement of mass flux and SMD using planar imaging technique agee with PDP A data fairly well in the low density region. However, in dense region, there are significant errors caused by secondary scattering. It was found that the planar imaging technique provides many advantages over the point measurement technique, such as PDP A, and can be implemented for quantitative measurement, especially in low density region.

2-dimensional Measurement of Arterial Pulse by Imaging Devices (촬상소자를 이용한 맥동의 2차원 계측)

  • Kim, Ki-Wang
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.12 no.2
    • /
    • pp.8-17
    • /
    • 2008
  • Objectives: For the traditional pulse diagnosis in Oriental Medicine, not only the pulse shape in time domain, but the width, length and depth of arterial pulse also should be measured. However, conventional pulse diagnostic systems have failed to measure the spatial parameters of the arterial pulse e.g. effective length of arterial pulse in the wrist. In fact, there are many ways to measure that kind of spatial features in arterial pulsation, but among them, the method using image sensor provides relatively cheap and simple way, therefore I tested feasibility of measuring 2-dimensional pressure distribution by imaging devices. Methods: Using widely used PC cameras and dotted balloons, the subtle oscillation of skin over the radial artery was recorded continuously, and then the displacement of every dot was calculated. Consequently, the time course of that displacements shows arterial pulse wave. Results: By the proposed method I could get pressure distribution map with 30Hz sampling rate, 21steps quantization resolution, and approximately 1mm spatial resolution. With reduced quantization resolution, $3cm{\times}4cm$ view angle could be achieved. Conclusion: Although this method has some limitations, it would be useful method for detecting 2-dimensional features of arterial pulse, and accordingly, this method provides a novel way to detect 'narrow pulse', 'wide pulse', 'long pulse', 'short pulse', and their derivatives.

  • PDF

A Study on Flow Characteristics with the Installed Location Change of Mechanical Deflector (기계적 편향판 설치위치의 변화에 따른 유동특성에 대한 연구)

  • Kim, Kyoung-Ryun;Park, Jong-Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.18 no.5
    • /
    • pp.49-53
    • /
    • 2015
  • Thrust vector control is the method which generates the side force and roll moment by controlling exhausted gas directly in a rocket nozzle. TVC is classified by mechanical and fluid dynamic methods. Mechanical methods can change the flow direction by several objects installed in a rocket nozzle exhaust such as tapered ramp tabs and jet vane. Fluid dynamic methods control the flight direction with the injection of secondary gaseous flows into the rocket nozzle. The tapered ramp tabs of mechanical methods are used in this paper. They installed at the rear in the rocket nozzle could be freely moved along axial and radial direction on the mounting ring to provide the mass flow rate which is injected from the rocket nozzle. TVC of the tapered ramp tabs has the potential to produce both large axial thrust and high lateral force. We have conducted the experimental research and flow analysis of ramp tabs to show the performance and the structural integrity of the TVC. The experiments are carried out with the supersonic cold flow system and the schlieren graph. This paper provides to analyze the location of normal shock wave and distribution of surface pressure on the region enclosed by the tapered ramp tabs.

Comparison of the Operational Speed of Hard-wired and IEC 61850 Standard-based Implementations of a Reverse Blocking Protection Scheme

  • Mnguni, Mkhululi Elvis Siyanda;Tzoneva, Raynitchka
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.3
    • /
    • pp.740-754
    • /
    • 2015
  • This paper focuses on the reverse blocking busbar protection scheme with aim to improve the speed of its operation and at the same time to increase operational reliability, flexibility and stability of the protection during external and internal faults by implementation of the extended functionality provided by the IEC61850 standard-based protective Intelligent Electronic Devices (IEDs). The practical implementation of the scheme by the use of IEC 61850 standard communication protocol is investigated. The proposed scheme is designed for a radial type of a distribution network and is modeled and simulated in the DigSILENT software environment for various faults on the busbar and its outgoing feeders. A laboratory test bench is built using three ABB IEDs 670 series that are compliant with the IEC 61850 standard, CMC 356 Omicron test injection device, PC, MOXA switch, and a DC power supplier. Two types of the reverse blocking signals between the IEDs in the test bench are considered: hard wired and Ethernet communication by using IEC 61850 standard GOOSE messages. Comparative experimental study of the operational trip response speeds of the two implementations for various traffic conditions of the communication network shows that the performance of the protection scheme for the case of Ethernet IEC 61850 standard-based communication is better.

An Analysis of Optical Performance of the Finite Schematic Eye According to Iris Eccentricity and Visual Axis change (시축 변화와 홍채 편심에 따른 정밀모형안의 광학적 성능 분석)

  • Kim, Bong-Hwan;Han, Sun-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.2
    • /
    • pp.151-154
    • /
    • 2010
  • Purpose: We investigated how the movement of iris and visual axis affects the finite schematic eye Methods: Using the schematic eye with the crystalline lens in the existing forms of the radial GRIN and the spherical GRIN, the iris centre was moved 0.5 mm in nasal direction and visual axis was tilted $5^{\circ}$ in same direction, with the additional degree of 2.5 down to locate the focal point in fovea. This study analyzed performance change of the optical system, designing it same as the real eye. Results: The whole aberration distribution showed a considerable difference in performance in comparison with the real eye; the biggest difference shown at the central field of optical system. The spherical aberration showed the biggest difference, and a peripheral power error and field curvature leaned toward (+) direction in aberration distribution. Conclusions: When designing the schematic eye with the performance similar with that of the real eye by taking into consideration the iris centre and visual axis, the aberration at the center field of optical system in particular should be corrected. Spherical aberration which showed the biggest difference should be corrected in the first place. In addition, a peripheral power error and field curvature that leaned toward (+) direction should be moved toward (-) direction.

A Study of Heat Storage System with Phase Change Material - Inward Melting in a Horizontal Cylinder (상변화 물질을 이용한 잠열축열조에 관한 기초 연구 - 수평원관내의 내향용융 열전달 실험 -)

  • Cho, N.C.;Kim, J.G.;Lee, C.M.;Yim, C.S.
    • Solar Energy
    • /
    • v.9 no.3
    • /
    • pp.44-54
    • /
    • 1989
  • Heat transfer phenomena during inward melting process of the phase change material were studied experimentally. N-docosane paraffin [$C_{22}H_{46}$] is used for phase change material and its melting temperature is $42.5^{\circ}C$. Experiments were performed for melting of an initially no-sub cooled or subcooled solid in a horizontal cylinder, in order to compare and investigate the radial temperature distribution, ratio of melting and melted mass, various energy components stored from the cylinder wall, figure of the melting front in the horizontal cylinder. The solid-liquid interface motion during phase change was recorded photographically. The experimental results reaffirmed the dominant role played by the conduction at early stage, by the natural convection at longer time during inward melting in the horizontal cylinder. Ratio of melting and melted mass are more influenced by wall temperature, rather than by the initial temperature of solid. The latent energy is the largest contributor to the total stored energy.

  • PDF

Capacitor Placement in Radial Distribution Systems Using Chaotic Search Algorithm (방사상 배전계통의 커패시터 설치를 위한 카오스 탐색알고리즘)

  • Rhee, Sang-Bong;Kim, Kyu-Ho;You, Seok-Ku
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.124-126
    • /
    • 2002
  • The general capacitor placement problem is a combinatorial optimization problem having an objective function composed of power losses and capacitor installation costs subject to bus voltage constraints. In this paper, the method employing the chaos search algorithm is proposed to solve optimal capacitor placement problem with reducing computational effort and enhancing optimality of the solution. Chaos method in optimization problem searches the global optimal solution on the regularity of chaotic motions and easily escapes from local or near optimal solution than stochastic optimization algorithms. The chaos optimization method is tested on 9 buses and 69 buses system to illustrate the effectiveness of the proposed method.

  • PDF

The Characteristics of a Transient Liquefied Butane Spray using PDPA and High Speed Camera (PDPA와 고속카메라에 의한 액상부탄 간헐분무 특성 연구)

  • 윤준규;임종한;김종현
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.3
    • /
    • pp.466-474
    • /
    • 2004
  • The characteristics of liquefied butane spray are expected to be different from conventional diesel fuel spray, because a flash boiling spray is expected when the surround pressure is below the saturated vapor pressure of the butane(0.23MPa 98K). The axial velocities. radial velocities. and size distributions in butane sprays were measured with PDPA(Phase Doppler Particle Analyzer) system. Sprays were macroscopically observed by using the high speed camera in case that the surround pressure is 0.37MPa and 0.15MPa. respectively. Compared with the conventional spray. the reversed results were investigated when the surround pressure is below the saturated vapor pressure of the butane.

Fatigue Life Analysis for Angular Contact Ball Bearing with Angular Misalignment (각 어긋남을 고려한 각접촉 볼베어링의 피로수명 해석)

  • Bae, Gyu-Hyun;Tong, Van-Canh;Hong, Seong-Wook
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.33 no.1
    • /
    • pp.53-61
    • /
    • 2016
  • Angular misalignment has a significant effect on the characteristics of angular contact ball bearings (ACBBs). This paper presents an analysis of fatigue life for ACBBs subjected to angular misalignment. A simulation model is developed with de Mul's bearing model and the ISO basic reference rating life model. Simulation is performed to calculate the life of the ACBBs subjected to angular misalignment. The numerical results show that angular misalignment influences the load distribution significantly, thus reducing the bearing rating life. The fatigue life of ACBBs is decreased by angular misalignment regardless of axial preload, external radial load and rotational speed. The results show that angular misalignment should be maintained at less than 1mrad for ACBBs.

Evaluation of Restoration Capability in Radial Primary Distribution System (배전계통의 복구능력 평가방법)

  • Lim, Seong-Il;Ha, Bok-Nam;Lee, Jung-Ho;Cho, Nam-Hun;Lee, Seong-Jae
    • Proceedings of the KIEE Conference
    • /
    • 1999.11b
    • /
    • pp.267-269
    • /
    • 1999
  • One of the main jobs of the operators is to make it sure to have a service continuity in a fault situation. This paper proposes a restoration index which indicates the restoration capability of the feeder in case of a fault. A necessary and sufficient condition for a feeder to have 100% restoration of the outage is also described.

  • PDF