• 제목/요약/키워드: Rad4

검색결과 309건 처리시간 0.024초

피치제어기 폐루프 시스템의 고유치 변화에 따른 풍력발전기의 성능 (Wind Turbine Performance for Eigen Value Change of Closed-Loop System for PI-Controller)

  • 김종화;문석준;신윤호;원문철
    • 풍력에너지저널
    • /
    • 제4권2호
    • /
    • pp.17-24
    • /
    • 2013
  • Idealized PID-controlled rotor-speed error for blade pitch control of wind turbines responds as a second-order system with natural frequency and damping ratio for closed-loop system. RISO National Laboratory has recommended specific natural frequency(=0.6 rad/s) and damping ratio(=0.7) for 2 MW wind turbine. The baseline controller for 5 MW wind turbine of NREL(National Renewable Energy Laboratory) is designed based on the same values of RISO recommendation. This study investigates the effect of the natural frequency and damping ratio of the controller for NREL 5 MW wind turbine. It is confirmed that RISO recommendation shall be tuned for each wind turbine.

ON GRADED (m, n)-CLOSED SUBMODULES

  • Rezvan Varmazyar
    • 대한수학회논문집
    • /
    • 제38권4호
    • /
    • pp.993-999
    • /
    • 2023
  • Let A be a G-graded commutative ring with identity and M a graded A-module. Let m, n be positive integers with m > n. A proper graded submodule L of M is said to be graded (m, n)-closed if amg·xt ∈ L implies that ang·xt ∈ L, where ag ∈ h(A) and xt ∈ h(M). The aim of this paper is to explore some basic properties of these class of submodules which are a generalization of graded (m, n)-closed ideals. Also, we investigate GCmn - rad property for graded submodules.

DFT 확산 방식의 OFDM 통신 시스템에서 위상잡음과 직교 불균형 보상 (Compensation of Phase Noise and IQ Imbalance in the OFDM Communication System of DFT Spreading Method)

  • 유상범;유흥균
    • 한국전자파학회논문지
    • /
    • 제20권1호
    • /
    • pp.21-28
    • /
    • 2009
  • DFT(Discrete Fourier Transform) 확산 방식의 OFDM(Orthogonal Frequency Division Multiplexing) 통신 시스템은 PAPR(Peak-to-Average Power Ratio) 저감에 매우 효과적인 시스템이며, 3GPP LTE($3^{rd}$ Generation Partnership Project Long Term Evolution)의 상향 링크에 SC-FDMA(Single Carrier-Frequency Division Multiple Access)에 사용된다. SC-FDMA는 일반적으로 OFDM 시스템보다 위상잡음과 직교 불균형으로 인한 ICI(Inter-Carrier Interference)에서 더 성능 열화가 발생하며, 등화기에 심각한 영향을 미친다. 그러므로 본 논문에서는 상향 링크에서 신호 전송 시 발생하는 위상잡음과 직교 불균형(IQ Imbalance: In-phase/Quadrature Imbalance), 그리고 전력 증폭기(HPA: High Power Amplifier)의 백-오프 특성에 따른 영향을 분석하고, ICI 성분을 제거할 수 있는 효과적인 등화 알고리듬을 제시한다. 제안된 등화기는 FDE(Frequency Domain Equalizer) 방식을 기반으로 설계하였으며, 기존의 PNS(Phase Noise Suppression) 알고리듬을 FDE에 사용될 수 있도록 수정하고 개선하여 위상 잡음과 직교 불균형으로 인한 ICI를 보상한다. 시뮬레이션 결과를 통하여 back-off 5.5 dB 상태에서 위상 잡음 $0.06\;rad^2$, 위상 에러 5도, 진폭 에러 0.005인 경우, 위상 잡음과 직교 불균형을 보상하여 SNR=14 dB 정도에서 $BER=10^{-4}$의 성능을 만족할 수 있다.

아베-코닉 프리즘을 이용한 스코프 개발 (Development of Scope with Abbe-König Prism)

  • 이동희;박승환
    • 한국안광학회지
    • /
    • 제18권4호
    • /
    • pp.509-517
    • /
    • 2013
  • 목적: 아베-코닉(Abbe-K$\ddot{o}$nig) 프리즘을 이용한 2.6X 광학식 스코프를 개발하고자 하였다. 방법: 먼저 대물렌즈의 초점거리와 유효구경의 크기를 고려하여 아베-코닉 프리즘을 설계하였다. 이렇게 설계되어진 아베-코닉 프리즘의 광학적, 기하학적 거리를 계산하였다. 이 계산 결과를 이용하여 전체 시스템의 광학적 유효거리 및 배율을 만족하도록 접안렌즈와 대물렌즈의 초점거리를 배분한 후 시스템을 최적화함으로서 전체 시스템을 완성하였다. 결과: Face length 11.5 mm를 가지는 아베-코닉 프리즘과 4매로 이루어진 초점거리 24.3 mm의 접안렌즈와 2매로 이루어진 초점거리 63.13 mm의 대물렌즈를 설계하여 약 2.6배율을 광학식 스코프를 완성할 수 있었다. 결론: 아베-코닉 프리즘을 채택한 2.6배율을 가지는 광학식 스코프를 설계 제작하였는데, $6.42^{\circ}$ 이내의 반 시야각에서 50% MTF 기준치로 200 cycles/rad의 분해능과 103 mm 유효 광학적 경통길이와 12.0 mm의 유효구경과 31 mm의 경통구경을 갖는 컴팩트한 광학계가 되었다.

Standard Measurement Procedure for Soil Radon Exhalation Rate and Its Uncertainty

  • Seo, Jihye;Nirwono, Muttaqin Margo;Park, Seong Jin;Lee, Sang Hoon
    • Journal of Radiation Protection and Research
    • /
    • 제43권1호
    • /
    • pp.29-38
    • /
    • 2018
  • Background: Radon contributing about 42% of annual average dose, mainly comes from soil. In this paper, standard measurement procedures for soil radon exhalation rate are suggested and their measurement uncertainties are analyzed. Materials and Methods: We used accumulation method for estimating surface exhalation rate. The closed-loop measurement system was made up with a RAD7 detector and a surface chamber. Radon activity concentrations in the system were observed as a function of time, with data collection of 5 and 15-minute and the measurement time of 4 hours. Linear and exponential fittings were used to obtain radon exhalation rates from observed data. Standard deviations of measurement uncertainties for two approaches were estimated using usual propagation rules. Results and Discussion: The exhalation rates (E) from linear approach, with 30 minutes measurement time were $44.8-48.6mBq{\cdot}m^{-2} {\cdot}s^{-1}$ or $2.14-2.32atom{\cdot}cm^{-2}{\cdot}s^{-1}$ with relative measurement uncertainty of about 10%. The contributions of fitting parameter A, volume (V) and surface (S) to the estimated measurement uncertainty of E were 59.8%, 30.1% and 10.1%, in average respectively. In exponential fitting, at 3-hour measurement we had E ranged of $51.6-69.2mBq{\cdot}m^{-2} {\cdot}s^{-1}$ or $2.46-3.30atom{\cdot}cm^{-2}{\cdot}s^{-1}$ with about 15% relative uncertainty. Fitting with 4-hour measurement resulted E about $51.3-68.2mBq{\cdot}m^{-2} {\cdot}s^{-1}$ or $2.45-3.25atom{\cdot}cm^{-2}{\cdot}s^{-1}$ with 10% relative uncertainty. The uncertainty contributions in exponential approach were 75.1%, 13.4%, 8.7%, and 2.9% for total decay constant k, fitting parameter B, V, and S, respectively. Conclusion: In obtaining exhalation rates, the linear approach is easy to apply, but by saturation feature of radon concentrations, the slope tends to decrease away from the expected slope for extended measurement time. For linear approach, measurement time of 1-hour or less was suggested. For exponential approach, the obtained exhalation rates showed similar values for any measurement time, but measurement time of 3-hour or more was suggested for about 10% relative uncertainty.

연속적 재발성 미성숙 기형종의 외과적 치료 (Surgical Experience of Recurrent Immature Teratoma - Report of a case -)

  • 홍민수
    • Journal of Chest Surgery
    • /
    • 제24권8호
    • /
    • pp.792-796
    • /
    • 1991
  • Immature teratoma can be viewed as intermediate between mature teratoma and embryonal carcinoma. Unlike the mature teratoma, elements of the three perm cell layers are incompletely differentiated and not arranged in organoid fashion In some area, more mature forms of these tissues may also be seen, Although this tumor is clearly malignant, they may not display clear-cut cytologic features of malignancy. The clinical prognosis is poor. We have experienced one case of recurrent immature teratoma. In first operation[1987, April], tumor of anterior mediastinum was removed with wedge resection of ant. segment of RUL % med. segment of RML. In 2nd operation[1990, June], recurrent teratoma of right inner thoracic wall was resected with partial 5th rib resection and wedge resection of lat. segment of middle lobe. Two months later, the 3rd operation[1990, September] was done, which was a removal of mass on thoracic wall near sup, segment of RLL and partial rib resection of 3rd, 4th & 5th. In November 1990, last operation[4th operation] was made. It was enucleation of walnut sized tumor located between medial segment of RML, and 4th. intercostal space, well encapsulated with endothoracic fascia and invaded into lung parenchyme, Adjuvant chemotherapy was done after each operation, but radiotherapy[5000 Rad] was done only after 1st operation. There was no evidence of recurrence after last operation. The patient is well-being still now.

  • PDF

전단접합 및 리브 플레이트로 보강한 H형 보-기둥 접합부의 내진성능에 관한 실험적 연구 (An Experimental Study on the Seismic Performance of Shear Connections and Rib Plate H Beam to Column Connections)

  • 오경현;서성연;김성용;양영성;김규석
    • 한국강구조학회 논문집
    • /
    • 제17권5호통권78호
    • /
    • pp.569-580
    • /
    • 2005
  • 기존 강구조 모멘트연성골조시스템의 기둥-보 접합부는 노스리지 지진과 고베 지진시 충분한 내진성능을 발휘하지 못하고 접합부에서 취성파괴가 발생하였다. 본 논문은 기존 접합부의 형상을 변화하여 H형강보 웨브의 고장력볼트 전단접합과 H형 플랜지의 리브보강 유무를 변수로 한 실대형 실험을 실시하였다. 실험목적은 보웨브의 2면전단접합으로 고장력 볼트수 감소와 시공성 향상을 기대하며, 리브플레이트 보강을 통해 내진성능을 향상시키고자 한다. H형강 보웨브의 2면전단접합과 리브플레이트로 보강한 접합부 실험결과, 기존 접합부보다 초기강성, 에너지 소산능력 및 소성회전능력이 높게 나타났으며, 내력상승률 및 변형능력은 전단탭의 위치로 인해 인장측과 압축측이 다소 차이를 보이고 있으나 전체적으로 우수한 내진성능을 나타냈다. 그리고 모든 시험체가 층간변위비 4%, 총소성회능력 약 0.029rad이상 및 접합부 최대내력이 원단면보 전소성모멘트의 약 130% 이상을 상회하여 중급모멘트연성골조이상의 설계가 가능하리라 사료된다.

연결 강판 형상에 따른 모듈러 유닛 간 접합부의 거동 비교 (Comparison of Behavior of Connections between Modular Units according to Shape of Connector Plates)

  • 이상섭;배규웅;박금성
    • 한국강구조학회 논문집
    • /
    • 제28권6호
    • /
    • pp.467-476
    • /
    • 2016
  • 모듈러 건축물에서 모듈러 유닛 사이의 접합은 연결 강판을 이용하여 볼트 접합하는 것이 일반적이다. 건축물의 강도는 가장 약한 부분에 의해 결정되며, 접합부는 부재보다 약한 부분이 될 가능성이 있다. 따라서 모듈러 건축물의 안전성을 확인하기 위해 모듈 내부 기둥-보 접합부의 구조성능뿐 아니라 모듈러 유닛과 유닛 접합부의 구조성능도 평가되어야 한다. 이 연구에서는 각형강관 기둥과 ㄷ형강보가 사용된 모듈이 일자형 접합철물과 십자형 접합철물로 연결된 접합부의 거동을 KBC2009 0722.2.4에 따라 모듈의 폭 방향과 길이 방향에 대해 층간 변위각으로 반복 가력을 제어하는 실험을 통해 조사하였다. 실험결과 모든 실험체는 0.04rad 변위각까지 비교적 안적정인 거동을 보였고, 길이 방향 실험체의 결과가 에너지 흡수능력 면에서 좋은 거동을 보였다. 그러나 일자형 연결 강판이 십자형 연결 강판에 비해 변위각이 커질수록 강성이 저하하고, 기둥의 실제 변위각이 늘어나는 결과를 보였다.

소형 전리함에 대한 TRS-398 선질인자 계산과 중심전극 보정에 관한 연구 (Study on the Evaluation of TRS-398 Quality Factors with Central Electrode Corrections for Small Cylindrical Chambers)

  • 강영록;이창열;김진호;문영민;곽동원;강상구;김정기;양광모;정동혁
    • 한국의학물리학회지:의학물리
    • /
    • 제22권3호
    • /
    • pp.148-154
    • /
    • 2011
  • TRS-398 프로토콜에서 중심전극에 대한 최근의 연구 결과들을 적용하여 선질인자($k_{Q,Q_0}$)를 평가하였다. 대상 전리함은 PTW-31010과 IBA-CC13이었다. 광자선 및 전자선 선질의 함수로서 선질인자를 계산하였으며 현재 TRS-398 프로토콜의 값들과 비교하였다. PTW-31010 전리함과 같이 알루미늄 전극으로 구성된 전리함에 대하여 새로운 보정을 취하는 경우에 선질인자가 광자선에서 최대 0.4% 그리고 전자선에서 최대 0.9% 증가하는 것으로 나타났다. 또한 IBA-CC13과 같이 C-552 전극을 사용하는 전리함의 경우에 기존의 보정체계를 그대로 적용할 수 있음을 확인하였다.

Particle Inflow Gun을 이용한 벼 캘러스 내의 효율적 유전자 도입 (Efficient Gene Introduction into Rice Callus by Using Particle Inflow Gun System)

  • 송인자;배창휴;최대옥;;이효연
    • Journal of Plant Biotechnology
    • /
    • 제29권4호
    • /
    • pp.223-228
    • /
    • 2002
  • 본 연구실에서 개발된 particle inflow gun (PIG)은 조작이 간편하고, 사용비용도 저렴하며, 식물 세포 내의 유전자 도입효율이 높은 특징을 갖고 있다. PIG 장비를 이용하여 벼 캘러스 내로의 유전자 도입 조건을 검토하기 위해서 사용된 vector는 pIG121Hm으로서 T-DNA 내부에 intron GUS ($\beta$-glucuronidase)와 hygromycin 및 kanamycin 저항성 유전자를 포함하고 있다. 또한 벼 캘러스 내에 물리적으로 DNA를 도입할 때에 DNA 도입 효율과 관계가 높은 요인들을 GUS의 발현빈도를 통하여 조사하였다. 그 결과 gold particle에 DNA를 부착하는 과정에 사용되는 spermidine과 calcium chloride의 경우 무첨가구에 비해 16 mM의 spermidine과 1.5 M의 calcium chloride 첨가구에서 GUS 발현율이 각각 2배, 3배 증가하였다. 그리고 1회 분사되는 gold particles양이 2 mg의 경우 가장 높은 GUS 발현율을 보여주었으며, 또한 PIG장비의 분사거리와 헬륨의 압력은 벼의 배양세포의 경우 12cm의 분사거리에서 3.5 bar (50 psi)의 헬륨압력으로 분사하였을 때 GUS 발현율이 가장 높았다. 이상의 결과에서 PIG 장비를 이용한 유전자 도입은 본 연구에서 검토한 최적의 조건을 이용하였을 경우 기존에 많이 사용되고 있는 Biolistic Gun (Bio-Rad 사)과 거의 비슷한 유전자 도입효율을 보여 주었다. 특히 PIG 장비의 경우 조작이 매우 간편하고, 분사에 사용되는 일회용 부품이 필요하지 않기 때문에 대량의 반복실험을 필요로 하는 연구에서 손쉽게 사용되리라 기대된다.