• Title/Summary/Keyword: RT-LAMP amplification

Search Result 25, Processing Time 0.023 seconds

Comparison of clinical diagnostic performance between commercial RRT-LAMP and RT-qPCR assays for SARS-CoV-2 detection

  • Kim, Hye-Ryung;Park, Jonghyun;Han, Hyung-Soo;Kim, Yu-Kyung;Jeon, Hyo-Sung;Park, Seung-Chun;Park, Choi-Kyu
    • Korean Journal of Veterinary Service
    • /
    • v.44 no.3
    • /
    • pp.163-168
    • /
    • 2021
  • The rapid and reliable detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) plays a key role in isolating infected patients and preventing further viral transmission. In this study, we evaluated the clinical diagnostic performances of a commercial real-time reverse transcription loop-mediated isothermal amplification (RRT-LAMP) assay (Isopollo® COVID-2 assay, M-monitor, Daegu, Korea) using eighty COVID-19 suspected clinical samples and compared these with the results of a commercial real-time reverse transcription polymerase chain reaction (RT-qPCR) assay (AllplexTM 2019-nCoV rRT-QPCR Assay, SeeGene, Seoul, Korea). The results of the RRT-LAMP assay targeting the N or RdRp gene of SARS-CoV-2 showed perfect agreement with the RT-qPCR assay results in terms of detection. Furthermore, the RRT-LAMP assay was completed in just within a 20-min reaction time, which is significantly faster than about the 2 h currently required for the RT-qPCR assay, thus enabling prompt decision making regarding the isolation of infected patients. The RRT-LAMP assay will be a valuable tool for rapid, sensitive, and specific detection of SARS-CoV-2 in human or unexpected animal clinical cases.

Rapid and Sensitive Detection of Hepatitis C Virus in Clinical Blood Samples Using Reverse Transcriptase Polymerase Spiral Reaction

  • Sun, Wenying;Du, Ying;Li, Xingku;Du, Bo
    • Journal of Microbiology and Biotechnology
    • /
    • v.30 no.3
    • /
    • pp.459-468
    • /
    • 2020
  • This study established a new polymerase spiral reaction (PSR) that combines with reverse transcription reactions for HCV detection targeting 5'UTR gene. To avoid cross-contamination of aerosols, an isothermal amplification tube (IAT), as a separate containment control, was used to judge the result. After optimizing the RT-PSR reaction system, its effectiveness and specificity were tested against 15 different virus strains which included 8 that were HCV positive and 7 as non-HCV controls. The results showed that the RT-PSR assay effectively detected all 8 HCV strains, and no false positives were found among the 7 non-HCV strains. The detection limit of our RT-PSR assay is comparable to the real-time RT-PCR, but is more sensitive than the RT-LAMP. The established RT-PSR assay was further evaluated for detection of HCV in clinical blood samples, and the resulting 80.25% detection rate demonstrated better or similar effectiveness compared to the RT-LAMP (79.63%) and real-time RT-PCR (80.25%). Overall, the results showed that the RT-PSR assay offers high specificity and sensitivity for HCV detection with great potential for screening HCV in clinical blood samples.

Development of a Novel Multiple Cross-Linking Spiral Amplification for Rapid and Sensitive Detection of HPV16 DNA

  • Zhang, Donghong;Liu, Dongliang;Liu, Bing;Ma, Xiulan
    • Journal of Microbiology and Biotechnology
    • /
    • v.31 no.4
    • /
    • pp.610-620
    • /
    • 2021
  • There has been increasing interest in the head and neck squamous cell carcinoma (HNSCC) that is caused by high-risk human papillomavirus (HR-HPV) and has posed a significant challenge to Otolaryngologists. A rapid, sensitive, and reliable method is required for the detection of HR-HPV in clinical specimens to prevent and treat HPV-induced diseases. In this study, a multiple cross-linking spiral amplification (MCLSA) assay was developed for the visual detection of HPV-16. In the MCLSA assay, samples were incubated under optimized conditions at 62℃ for 45 min, and after mixing with the SYBR Green I (SGI) dye, the positive amplicons showed bright green fluorescence while the negative amplicons exhibited no obvious change. The specificity test revealed that the developed MCLSA technique had high specificity and could effectively distinguish all five HPV-16 strains from other pathogenic microorganisms. In terms of analytical sensitivity, the limit of detection (LoD) of MCLSA assay was approximately 5.4 × 101 copies/tube, which was 10-fold more sensitive than loop-mediated isothermal amplification (LAMP) and RT-PCR. The detection results of laryngeal cancer specimens collected from 46 patients with suspected HPV infection in the Liaoning region demonstrated that the positive detection rates of MCLSA and hybridized capture 2 kit were 32.61% (15/46). The true positive rate of the MCLSA assay was higher than that of RT-PCR (100% vs. 93.33%) and LAMP (100% vs. 86.67%). Therefore, the MCLSA assay developed in the present study could be a potentially useful tool for the point-of-care (PoC) diagnosis of HR-HPV, especially in resource-limited countries.

Characteristics and Diagnostic Methods of Streptococcosis Causing Disease in Aquaculture (양식 어류에 질병을 유발하는 연쇄구균증의 특성 및 진단 방법)

  • Kim, Dong-Hwi;Heo, Moon-Soo
    • Journal of Life Science
    • /
    • v.28 no.9
    • /
    • pp.1118-1126
    • /
    • 2018
  • In this study, investigated the general characteristics and diagnostic methods types of streptococcosis among various fish disease pathogens that caused a lot of economic damaged to aquaculture fish based on the previous research paper. Streptococcosis infection of fish is considered a reemerging disease affecting a variety of wild and cultured fish throughout the world. Calssifiacation of Gram positive cocci based on DNA-DNA hybridization coupled with 16S sequencing has shown that at least five different species are considered of significance as fish pathogens: Lactococcus garvieae, L. piscium, Streptococcus iniae, S. agalactiae, S. paruberis, Vagococcus salmoninarum. Symptoms of infection with streptococcosis disease such as body color change, eyeball abnormality, gill discoloration, bleeding, abdominal distension, swelling of the kidney and spleen. In addition, it usually occurs from June to October when the water temperature rise a lot of fish death. Currently, 16S rRNA, 16S-23S rRNA intergenic spacer region (ISR), Random Amplified polymorphic DNA (RAPD), Ribotyion (RT), Loop-mediated isothermal amplification (LAMP) are among the methods for diagnosing streptococcosis. Among them, the LAMP method, which is high applicable to the aquaculture farm has attracted the spotlight, but due to problems such as confirmation of results. This seems to minimize the economic loss of streptococcosis which complements the problem so that it can be easily used from the diagnosis to the results confirmation.

Comparison of SureTectTM with phenotypic and genotypic method for the detection of Salmonella spp. and Listeria monocytogenes in ready-to-eat foods (즉석섭취식품에 존재하는 Salmonella spp.와 Listeria monocytogenes의 검출을 위한 SureTectTM와 표현형 및 유전자형 방법의 비교)

  • Kye-Hwan Byun;Byoung Hu Kim;Ah Jin Cho;Eun Her;Sunghee Yoon;Taeik Kim;Sang-Do Ha
    • Food Science and Preservation
    • /
    • v.30 no.2
    • /
    • pp.262-271
    • /
    • 2023
  • The objective of this study is to compare and assess the effectiveness of real-time polymerase chain reaction (RT-PCR), loop-mediated isothermal amplification (LAMP), and the selective agar plate method for the detection of Salmonella spp. and Listeria monocytogenes in ready-to-eat (RTE) foods. In RTE foods, the detection performance of the three methods (RT-PCR [SureTectTM kit and PowerChekTM kit], LAMP [3M MDS], selective agar) were similar at 0-10, 10-50, 50-100, and 100- CFU/mL of Salmonella spp. and L. monocytogenes. We found that with RT-PCR, the Ct value of salad was significantly higher (p<0.05) than other RTE foods, indicating that fiber plays a critical role as an obstacle to the rapid detection of Salmonella spp. However, the Ct value displayed a mixed pattern according to the inoculation level of L. monocytogenes. The use of rapid detection kits and machines mostly depends on the user's choice, with accuracy, ease of use, and economy being the primary considerations. As an RT-PCR kit, SureTectTM and PowerChekTM showed high accuracy in detecting Salmonella spp. and L. monocytogenes in RTE foods, showing that they can replace the existing RT-PCR kits available. Additionally, LAMP also showed excellent detection performance, suggesting that it has the potential to be used as a food safety management tool.