• 제목/요약/키워드: RSD

검색결과 529건 처리시간 0.026초

웨이블릿 변환을 이용한 실시간 화재 감지 알고리즘 (Development of Web-based Bio-Image Retrieval System)

  • Cheong, Kwang-Ho;Ko, Byoung-Chul;Nam, Jae-Yeal
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2006년도 추계학술발표대회
    • /
    • pp.227-230
    • /
    • 2006
  • A content-based image retrieval system using MPEG-7 is designed and implemented in this thesis. The implemented system uses existing MPEG-7 Visual Descriptors. In addition, a new descriptor for efficient retrieval of bio images is proposed and utilized in the developed content-based image retrieval system. Comparing proposed CBSD(Compact Binary Shape Descriptor) with Edge Histogram Descriptor(EHD) and Region Shape Descriptor(RSD), it shows good retrieval performance in NMRR. The proposed descriptor is robust to large modification of brightness and contrast and especially improved retrieval performance to search images with similar shapes. Also proposed system adopts distributed architecture to solve increased server overload and network delay. Updating module of client efficiently reduces downloading time for metadata. The developed system can efficiently retrieve images without causing server's overload.

  • PDF

형광광도법에 의한 Histidine의 정량에 관한 연구 (Determination of Histidine by Spectrofluorometry)

  • 차기원;황화자
    • 분석과학
    • /
    • 제17권2호
    • /
    • pp.180-183
    • /
    • 2004
  • 형광광도법을 이용하여 histidine 아미노산을 간단하고미량까지 정확하게 정량 하는 방법을 연구하였다. $Eu^{3+}$ - TTA- histidine 착물의 방출 봉우리는 235 nm에서 들뜰 때 470 nm에서 나타나며 그의 형광세기는 histidine을 $1{\times}10^{-7}-4{\times}10^{-6}M$까지 가함에 따라 직선적으로 증가하였다. 이를 이용하여 histidine을 정량 하는 방법을 연구하였다. 검출 한계는 $5{\times}10^{-7}M$이였으며 이때의 상대표준편차는 3.5%이였다. 이 방법을 합성 시료에서 histidine을 정량 하는데 이용하였다.

흡착벗김 전압전류법에 의한 시안화이온의 정량 (Determination of Cyanide Ion by Adsorptive Stripping Voltammetry)

  • 차기원;고수진;김재균
    • 분석과학
    • /
    • 제14권6호
    • /
    • pp.540-544
    • /
    • 2001
  • Determination of cyanide ion has been studied by adsorptive stripping voltammetry using hanging mercury electrode. Cyanide ion complexed with copper ion is adsorpbed on the electrode and oxidised at the positive potential scan. Optimal conditions of CN determination were found to be ; supporting electrolyte solution ; 0.1 M NaCl of ammonium buffer at pH 10, accumulation potential; -800 mV vs Ag/AgCl, accumulation time ; 300 s, scan rate ; 50mV/s. The linear concentration of cyanide ion was observed in the range $1{\times}10^{-8}$, $1{\times}10^{-7}M$. The detection limit(n/s=3) was $0.13{\mu}g/L$($5{\times}10^{-9}M$) with 3.5% RSD.

  • PDF

Dual Capillary Column System for the Qualitative Gas Chromatography: 1. Comparison Between Split and Splitless Injection Modes

  • Kim, Kyoung-Rae;Kim, Jung-Han;Park, Hyoung-Kook;Oh, Chang-Hwan
    • Bulletin of the Korean Chemical Society
    • /
    • 제12권1호
    • /
    • pp.87-92
    • /
    • 1991
  • A dual capillary column system is described for the simultaneous measurement of retention index (RI) and area ratio (AR) values of each peak on two capillary columns of different polarity, DB-5 & DB-1701. Both capillary columns were connected to a common splitless injector via a deactivated fused-silica capillary tubing of 1 m length and a 'Y' splitter, the dead volume effect of which was found to be negligible. RI and AR were measured with high reproducibility(${\leq}$0.05% RSD) and with high accuracy (<10% RE), respectively. When applied to the test samples of the organic acid mixture, each acid was positively identified by the combined computer RI library search-AR comparison.

Direct Anlysis of Impurities in Solides with Glow Discharge Mass Spectrometry

  • Ki Beom Lee;Dae Won Moon;Kwang Woo Lee
    • Bulletin of the Korean Chemical Society
    • /
    • 제10권6호
    • /
    • pp.524-529
    • /
    • 1989
  • A glow discharge mass spectrometric(GDMS) analytical method was developed for direct analysis of impurities in solids. Ions extracted from a glow discharge ion source with a sample as a cathode were analyzed by a quadrupole mass filter. Ion extractions were carried out through differentially-pumped orifices biased to positive and negative potentials. Operating parameters of the glow discharge source such as discharge current, orifice-to-cathode distance, energy analyzer setting and bias voltages have been optimized. The developed GDMS was applied to the analysis of KSS copper-base alloy standards certified by Korea Standards Research Institute(KSRI). In the analysis, the reproducibility and the detection limits were estimated to be about 2.5% RSD, and in the low ppm range, respectively.

The Simultaneous Analysis of Benzene, Toluene, Ethylbenzene, o,m,p-Xylenes and Total Petroleum Hydrocarbons in Soil by GC-FID after Ultra-Sonication

  • 신호상;권오승
    • Bulletin of the Korean Chemical Society
    • /
    • 제21권11호
    • /
    • pp.1101-1105
    • /
    • 2000
  • A simultaneous determination method of BTEX (benzene, toluene, ethylbenzene, o,m.p-xylene) and TPH (kerosene, diesel, jet fuel and bunker C) in soil with gas chromatography/flame ionization detection (GC-FID) was described. The effects of extracti on method, extraction solvent, solvent volume and extraction time on the extraction performance were studied. A sonication method was simpler and more efficient than Soxhlet or shaking methods. Sonication with 10 mL of acetone/methylene chloride (1 : 1, v/v) for 10 min was found to be optimal extraction conditions for 20 g of soil. Peak shapes and quantification of BTEX and TPH were excellent, with linear calibration curves over a wide range of 1-500 mg/L for BTEX and 10-5000 mg/L for TPH. Good reproducibilities by sonication were obtained, with the RSD values below 10%. By using about 20 g of soil, detection limits were 0.8 mg/L for BTEX and 10 mg/L for TPH. The advantages of this procedure are the use of simple and common equipment, reduced volumes of organic solvents, rapid extraction periods of less than 20 min, and simultaneous analysis of volatile and semivolatile compounds.

Diagnostic ex vivo assay of glucose in live cell using voltammetry

  • Ly, Suw Young;Leea, Chang Hyun
    • 한국응용과학기술학회지
    • /
    • 제35권4호
    • /
    • pp.1379-1385
    • /
    • 2018
  • The hand held voltammetry systems searched diabetic assay using glucose sensor of fluorine nafion doped carbon nanotube electrode (FCNE). An inexpensive graphite carbon pencil was used as an Ag/AgCl reference and Pt counter electrode. Upon combining and using three electrode systems, optimum square wave (SW) stripping results were attained to 1.0-9.0 ug/L with 8 points. Statistic RSD precision was of 6.02 % with n=15 in 0.1 mg/L glucose. After a total of 200 second accumulation times, analytical detection limit of 0.8 ug/L was obtained. This developed technique was applied to urine samples from diabetic patients urine for fluid analysis, it was determined that the sensor can be used with a diagnostics in the ex vivo of live cells and non treated biological fluid.

Electrochemical Determination of Capsaicin by Ionic Liquid Composite-Modified Electrode

  • Kim, Dong-Hwan;Nam, Sungju;Kim, Jaeyoon;Lee, Won-Yong
    • Journal of Electrochemical Science and Technology
    • /
    • 제10권2호
    • /
    • pp.177-184
    • /
    • 2019
  • An electrochemical detection method for capsaicin has been developed using ionic liquid (IL) doped graphene-titania-Nafion composite-modified electrode. The combination of IL (1-hexyl-3-methylimidazolium with hexafluorophosphate counter ion) in the composite-modified electrode resulted in a significantly increased electrochemical response for capsaicin compared to that obtained at the corresponding electrode without IL. The increased electrochemical signal could be ascribed to the decreased electron transfer resistance through the composite film and also to the effective accumulation of capsaicin on the electrode surface due to ${\pi}-{\pi}$ interaction of the imidazole groups of IL with the aromatic rings of capsaicin. The present IL composite-modified electrode can detect capsaicin with a concentration range from $3.0{\times}10^{-8}M$ to $1.0{\times}10^{-5}M$ with a detection limit of $3.17{\times}10^{-9}M$ (S/N = 3). The present sensor showed good reproducibility (RSD = 3.2%).

Dual Capillary Column System for the Qualitative Gas Chromatography: 2. Comparison between Splitless and On-Column Injection Modes

  • Kim, Kyoung-Rae;Kim, Jung-Han;Park, Hyoung-Kook;Oh, Chang-Hwan
    • Bulletin of the Korean Chemical Society
    • /
    • 제14권2호
    • /
    • pp.250-255
    • /
    • 1993
  • A dual capillary column system is described for the simultaneous analysis of a given sample and measurement of retention index (RI) and area ratio (AR) values of each peak on two capillary columns of different polarity, DB-5 & DB-1701 from a single injection. Both capillary columns were connected to either a splitless injector or an on-column injector via a deactivated fused-silica capillary tubing of 1 m length and a 'Y' splitter. Both injection modes allowed to measure RI and AR values with high reproducibility (<0.01% RSD) and high accuracy (<10% RE), respectively with the exception that the trace and high boiling solutes required the on-column mode for the accurate quantification and AR comparison. When the dual capillary column system in on-column injection mode was applied to the blind samples containing organic acids, each acid was positively indentified by the combined computer RI library search-AR comparison.

Determination of Water Soluble Trace Gass in Ambient Air by Condenser-type Diffusion Denuder Coupled Ion Chromatography

  • 장인형;최낙현;이보경;이동수
    • Bulletin of the Korean Chemical Society
    • /
    • 제20권3호
    • /
    • pp.329-332
    • /
    • 1999
  • An automated method is developed for simultaneous determination of water soluble gases at parts per trillion level in the environmental air. The method involves temperature-humidity control of sample air using a thermostated humidifier, collection of analyte gases by condenser-type effluent diffusion denuder and subsequent effluent analysis by ion chromatography. The detection limits (3(σ) of the method for CH3COOH, HNO2 and SO2 gases are 0.022, 0.019 and 0.009 ppbv, respectively. The precisions range from 0.3 to 3.0% RSD. The method has been successfully applied to urban air analysis and some results for nitrous acid and SOx, in Seoul air are presented.