• 제목/요약/키워드: RS485

검색결과 176건 처리시간 0.024초

선박용 ICCP 제어 감시 시스템에 관한 연구 (A Study on the ICCP Control and Monitoring System for Ship)

  • 이지영;오진석
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제28권4호
    • /
    • pp.667-674
    • /
    • 2004
  • This thesis is about the Impressed Current Cathodic Protection (ICCP) control and monitoring system. which brings protection against the corrosion of the ship's hull in the sea environments. The ICCP system is composed of a power supply. anode. reference electrode and controller. AC sources from the ship's generator are converted to DC sources in terms of power supply, and a protection current is sent to ship's hull though anode. The controller fully senses whether or not the detected potential is within a range of protection of ship's hull and then it is automatically controlled to increase or decrease the amount of protective current to be sent to the anode. The monitoring system with RS 232/485 communication is also studied in order to check the normal state of the system at a long period. because an operator does not always watch over this system and thus the system cannot operate well because of his or her negligent management. Since the vessel always navigates in the sea. an characteristics experiment of the ICCP system is conducted by introducing various corrosive environmental factors such as velocity, resistivity, dissolved oxygen, PH, temperature and contamination degree. These results must be referred to when the ICCP system is set up. In short. the ICCP is a multi-system for use on ships and on land structures because it includes a safety device. It is suggested that this system can accomodate a ship's automation and will be very useful.

보안성을 겸비한 전이중방식의 다중레벨 통신드라이브에 관한 연구 (A Study on Multilevel Communication Drive of Full-Duplex Method with Security)

  • 조수억;박성미
    • 한국산업융합학회 논문집
    • /
    • 제23권1호
    • /
    • pp.41-48
    • /
    • 2020
  • Currently, the industry uses MODBUS communication method using RS485 as a communication method used when constructing distributed equipment and networks. However, this method has a rather good transmission and reception distance, but has a disadvantage of being a half-duplex communication method. Therefore, there is a great need for a full-duplex communication method that can simultaneously transmit and receive two-wire communications. Therefore, in this paper, we propose a new communication hardware equipment that can implement full-duplex communication method by communication signal level to overcome the disadvantage of communication speed. The proposed communication hardware is a structure that can transmit and receive at the same time on the same communication line in two equipments communicating in a two-wire system. The characteristic of this communication hardware is that the transmitter generates two-level signal for data transmission, but the receiver generates three-level electric signal according to the status of the transmission data generated by the receiver. The data transmission signal information of the receiver is present at the same time. Therefore, the receiving side can analyze the received signal based on the information on the current transmission signal and can analyze the signal only in the two communicating devices, so it can be seen that the communication security is very excellent.

온실 생육환경 및 제어정보 데이터베이스 개발 (Development of Database for Environment and Control Information in Greenhouse)

  • 공대광;류관희;진제용
    • Journal of Biosystems Engineering
    • /
    • 제28권1호
    • /
    • pp.59-64
    • /
    • 2003
  • This study was carried out to develop database system using internet fur greenhouse. The database system consisted of group monitor, client monitor. server monitor and DBMS. The results of the study are summarized as follows. 1. The monitoring module, as data collection system for database. could monitor the state of the control device and the greenhouse environment. 2 The group monitor was connected to the house monitors by RS-485 communication method. Data received by the group monitor were sent to the server monitor and then stored in database server by TCP/IP and MIDAS. 3. The data of database consisted of on growing environment. control devices, operation and cultivation data in greenhouse. It was developed using MS-SQL server. 4. Remote monitoring of greenhouse was realized in a client/server environment. The client module. which was named as the client monitor. made requests to access the measurement data of greenhouse through the remote data module of the server monitor in internet environment.

환자모니터링시스템의 개발 : 전체구조 및 기본사양 (Development of a Patient Monitoring System Overall Architecture and Specifications)

  • 우응제;박승훈
    • 대한의용생체공학회:의공학회지
    • /
    • 제18권1호
    • /
    • pp.17-24
    • /
    • 1997
  • We have developed a patient monitoring system including module-based bedside monitors, interbed network, central stations, clinical workstations, and DB servers. A bedside monitor with a color LCD can accommodate up to 3 module cases and 21 different modules. Six different physiological parameters of ECG, respiration, invasive blood pressure, noninvasive blood pressure, body temperature, and arterial pulse oximetry with plethysmoyaph are provided as parameter modules. In a single bedside monitor, modules and a module controller communicate with IMbps data rate through an intrabed network based on RS-485 and HDU protocol. At the same time, it communicates with other bedside monitors and central stations through interbed network based on 1 OMbps Ethernet and TCP/IP protocol. Central stations using 20" color CRT monitors can be connected with many bedside monitors and they display 18 channels of waveforms simultaneously. Clinical workstations are used mainly for the review of patient datE In order to accommodate more advanced data management capabilities such as 24-hour full disclosure, we have developed a relational database server dedicated to the patient monitoring system. Software for bedside monitor, central station, and clinical workstation fully utilizes graphical user interface techniques and all functions are controlled by a rotate/push button on the bedside monitor arid a mouse on the central station and clinical workstation. The entire system satisfies the requirements of AAMI and ANSI standards in terms of electrical safety and performances.nces.

  • PDF

IR 센서 및 Compass 센서를 이용한 생체 모방형 수중 로봇의 장애물 인식 및 회피 (Obstacle Recognition and Avoidance of the Bio-mimetic Underwater Robot using IR and Compass Senso)

  • 이동혁;김현우;이장명
    • 제어로봇시스템학회논문지
    • /
    • 제18권10호
    • /
    • pp.928-933
    • /
    • 2012
  • In this paper, the IR and compass sensors for the underwater system were used. The walls of the water tank have been recognized and avoided treating the walls as obstacles by the bio-mimetic underwater robot. This paper is consists of two parts: 1.The hardware part for the IR and compass sensors and 2.The software part for obstacle avoidance algorithm while the bio-mimetic robot is swimming with the obstacle recognition. Firstly, the hardware part controls through the RS-485 communications between a microcontroller and the bio-mimetic underwater robot. The software part is simulated for obstacle recognition and collision avoidance based upon the data from IR and compass sensors. Actually, the bio-mimetic underwater robot recognizes where is the obstacle as well as where is the bio-mimetic robot itself while it is moving in the water. While the underwater robot is moving at a constant speed recognizing the wall of water tank as an obstacle, an obstacle avoidance algorithm is applied for the wall following swimming based upon the IR and compass sensor data. As the results of this research, it is concluded that the bio-mimetic underwater robot can follow the wall of the water tank efficiently, while it is avoiding collision to the wall.

오프로드 환경에서 효율적인 6족 로봇 보행 시스템 개발 (Development of an Effective Walking System for a Hexapod Robot on Uneven Terrain)

  • 김준우;이기원;이석규
    • 제어로봇시스템학회논문지
    • /
    • 제19권12호
    • /
    • pp.1152-1159
    • /
    • 2013
  • This paper proposes an effective walking system for a hexapod robot on uneven terrain. To overcome the deficiencies of two-pair walking systems, which are effective on even terrain, the use of only three legs changes the steps required for movement. The proposed system receives feedback data from switches attached to the bottom of the legs and gyro sensor to carry out stable walking using the Bezier curve algorithm. From the coordinates of the Bezier curve, which guarantees the circular motion of legs, the motor's angle value can be obtained using inverse kinematics. The angle values are sent to each motor though RS-485 communication. If a switch is pushed by the surface during navigation in the Bezier curve pattern, the robot is designed to change its circular course. Through the changed course, each leg can be located on an optimal surface and the wobble phenomenon is reduced by using a normal vector algorithm. The simulation and experiment results show the efficiency of the proposed algorithm.

LabVIEW를 이용한 Modbus/RTU 프로토콜 구현 (Implementation for Modbus/RTU Protocol Using LabVIEW)

  • 정태일;이태오;김관형;김현수;이형기
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2015년도 추계학술대회
    • /
    • pp.1054-1057
    • /
    • 2015
  • 실제적인 산업분야에서 실시간 처리는 중요하다. 본 논문에서는 LabVIEW를 이용하여 RS-485 직렬통신 기반 Modbus/RTU 프로토콜을 구현하였다. 토크(Torque) 센서와 전압/전류계로부터 측정값을 입력받기 위하여 Modbus/RTU 프로토콜을 구현하였다. 입력받은 토크 값, 전압, 전류 값을 이용하여 기계적인 손실을 계산할 수 있다. LabVIEW 툴을 이용하여 소스코드를 작성하였고, 이러한 소스코드는 실제 산업현장에 적용할 수 있음을 확인하였다.

  • PDF

전력선 통신을 이용한 집단주택 안전관리 시스템 (Security Monitoring System for Apartment House Building Using Paver Line Carrier)

  • 김인수;김관호;김요희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 하계학술대회 논문집 A
    • /
    • pp.476-478
    • /
    • 1993
  • Instead of installing new communication wiring to each house in the apartment house building. the power distribution network. which is already installed in the building. can be use as communication medium. In a safty management, by adoption of power line communication system, at remote we can monitor safty related sensors such as fire, gas leakage, burglar intrusion and emergency call which are located at each house. From this viewpoint, we developed security monitoring system for apartment house building using power lines. Security monitoring system consists of Power Line Communication-Sub Controller (PLC-SC). Power Line Communication-Main Controller (PLC-MC) and Management System (MS). Between a PLC-MC and a PLC-SC, the transmission rate is 1200 bps in power lines and modulation technique is frequency shirt keying (FSK). In between a PLC-MC and a MS, the transmission rate is 1200 bps in communication line (RS-485). As a result of this research. transmission loss is 0.1dB per meter of intrabuilding distribution network. Transmission can be reach in 250 meters. So it is enough to communicate for security monitoring system in apartment house building.

  • PDF

고신뢰 무선센서네트워크를 이용한 실시간 수질 모니터링 시스템 (Real-time Water Monitoring System for Small Water Supply Facility using High Reliable Wireless Sensor Network)

  • 강호용;장윤선
    • 센서학회지
    • /
    • 제24권5호
    • /
    • pp.331-341
    • /
    • 2015
  • In this paper, real-time water quality monitoring system of small water supply facilities based on IEEE 802.15.4e-2012 DSME MAC and IEEE 802.15.4g-2012 PHY standard is presented, which is capable to acquire for highly reliable water quality information in the wide outdoor areas for effective water quality management of small water quality facilities is distributed in the long distance and remote areas. Previously, Long distance transmission is difficult in most water quality sensor module is using RS-485 protocol. But with this system, even in harsh outdoor environment, it is possible to establish a radio wave sensor in a wide area network, and not only water quality sensor shall be connected to the wireless system, but also wireless integrated management system shall provide more effective way of management of the numerous small water supply facilities spread throughout the community, so that the administrator can remotely monitor the data of water turbidity, pH, residual chlorine in the water-supply, water-level, and generate alarm to cope with risks. The management of small water facilities is done by residents will be very effective to notice water quality information of small water facilities to residents.

고해상도 심전계의 개발 (Development of a High-Resolution Electrocardiography)

  • 이호성;우응제;박승훈;이종민;박광석
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1996년도 춘계학술대회
    • /
    • pp.179-183
    • /
    • 1996
  • Most of the conventional electrocardiogaphies fail to detect signals other than P-QRS-T due to the limited SNR and bandwidth. High-resolution electrocardiography (HRECG) provides better SNR and wider bandwidth for the detection of micro-potentials with higher frequency components such as ventricual late potentials(LP). In this paper, we developed a HRECG using uncorrected XYZ lead. The overall gain of the amplifier is 4000 and the bandwidth is $0.5{\sim}300Hz$ without using 60Hz notch filter. Three 16-bit AH converters sample X, Y, and Z signals simultaneously with a sampling frequency of 2000Hz. Sampled data are transmitted to PC via a DMA-controlled serial communication channel using RS-485 and HDLC protocol. The noise level of the developed HRECG is less than $5{\mu}V_{rms,\;RTI}$. In order to further reduce the noise level, signal averaging technique is implemented utilizing template matching method. The SNR of the developed HRECG is high enough for the detection of LP.

  • PDF