• Title/Summary/Keyword: RPM system

Search Result 1,046, Processing Time 0.028 seconds

Study on measuring the low torque on an air tool operating at 100,000 RPM class (100,000 RPM급으로 회전하는 에어공구에서의 저토오크 측정에 관한연구)

  • Kim, Eun-Jong;Cho, Soo-Yong
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.2018-2023
    • /
    • 2003
  • An experiment is conducted for measuring the performance of an air tool, which is operated at 100,000 RPM at the unloaded state with the low torque. An experimental apparatus is developed as the power absorption type dynamometer. Inlet static pressure, flow rate, RPM and force are measured simultaneously. Torque, output power and specific output power are obtained. Those experimental results are compared with the experimental results obtained on a commercial dynamometer. However, no commercial dynamometers are available for measuring the torque above 30,000RPM. In order to use the commercial dynamometer, a reduction gear is applied to the shaft of dynamometer. Torque and power obtained on the commercial dynamometer show 50% lower than those obtained on a power absorption type dynamometer, because the inertia force is added to the air tool rotor for the braking system. Moreover, the starting RPM on the commercial dynamometer is less than 40,000RPM. From the compared results, they show that the power absorption type dynamometer should be applied for measuring the performance of an air tool operating at low torque and high RPM.

  • PDF

Development of a Power-tiller TMF Mixer (동력경운기 견인형 TMF 배합기의 개발)

  • Jo, Gi-Hyeon;Lee, Jeong-Taek;Baek, Lee
    • Journal of Biosystems Engineering
    • /
    • v.28 no.2
    • /
    • pp.97-106
    • /
    • 2003
  • One of the obstructing factors against managing dairy fm has been heavy labor requirement for feeding dairy cows. A Power-tiller TMF mixer was developed to reduce the cost and to provide economic benefit. The TMF mixer was desisted by the feeding capacity of 20∼30 heads at a batch with various functioning systems of auger type mixer, delivery conveyer, weighing console, pipe heater type heating system, power transmission train and mounting trailer. According to the study resulted, it showed that 1,200rpm, 1,600rpm, 2,000rpm and 2,300rpm were 6ps. Bps, lops and 12ps respectively. and that reduced shaft output by 15%. On the fodder mixer attached powertiller, initial output was necessary large torque. And the heating system was maintaining uniform temperature 60$^{\circ}C$ relatively.

Development of Planetary Reduction Motor with Mechanical Power Monitoring and Network Capability

  • Jang In-Hun;Sim Kwee-Bo
    • International Journal of Control, Automation, and Systems
    • /
    • v.4 no.3
    • /
    • pp.359-364
    • /
    • 2006
  • This article describes the useful way to measure the torque and RPM of the geared motor. For this we have made the planetary geared reduction motor including 2 Hall sensors in it and the monitoring system. The monitoring system displays the sensing values (torque, rpm) and the calculated value (power) and it also has the network capability using the Bluetooth protocol. We will show that our solution is much more inexpensive and simple method to measure torque and rpm than before.

Sea water Treatment using an Automatic Backwashing Filter (자동역세척 여과장치를 이용한 해수처리)

  • Park Sang-Ho;Lim Jae-Dong;Kim In-Soo
    • Journal of Navigation and Port Research
    • /
    • v.30 no.3 s.109
    • /
    • pp.241-245
    • /
    • 2006
  • Displayed result that handle particle contaminant and hydrospace organism included a number of ballast that is happened in ship using automatic back washing filter. Reason that removes first contaminant that is included in number of ballast is that heighten processing effectof after processing processof the filter. Another advantage is to drop off the solids with controlling revolution of drum screen in pretreatment filtration process. The fact that it is easy to attach and detach a several type of screen for getting the expected water quality is another advantage. Filter rotation speed of filtration filter could be expose by 35mmHg more than 60 rpm and filter consecutively filtration pressure is 40.5mmHg in 20 rpm and 40 rpm are 36.6mmHg. Filtration system removal aquatic organism over $70{\mu}min$ ballast water. This study shows that the filtration treatment system has a potential for the treatment of ballast water.

Effects of Rotational Speed and Hydraulic Residence Time on the Ammonia Removal of a Rotating Biological Contactor (RBC) (회전속도와 수리학적 체류시간이 회전원판식(Rotating Biological Contactor;RBC) 여과조의 암모니아 제거에 미치는 영향)

  • 오승용;조재윤;김종만
    • Journal of Aquaculture
    • /
    • v.16 no.3
    • /
    • pp.142-150
    • /
    • 2003
  • Performance of a biological filter, the rotating biological contactor (RBC), is affected by rotational speed and hydraulic residence time (HRT). A RBC with a disc diameter of 62 cm, total surface area of 48.28 $m^2$, volume of 0.34 ㎥, and submergence ratio of 35.4% was tested for the combinations of five rotational speeds (1, 2, 3, 4 & 5 rpm) and three HRT (0.5, 1.0 & 2.0 hr) to find out the maximum removal efficiencies of total ammonia nitrogen (TAN) and nitrite nitrogen of a simulated recirculating aquaculture system. Ammonia loading rate in the system was 25 g of TAN/ ㎥. day. Removal efficiencies were checked when TAN concentrations in the system stabilized for 3 days in each treatment. The concentration of TAN in the system decreased with increasing rotational speed of the RBC up to 4 rpm in all HRT (P<0.05). At the rotational speed of 5 rpm, the efficiencies decreased in all HRT (P<0.05). When the rotational speeds were 1, 2, 3, 4, and 5 rpm, TAN concentrations in the system were 1.35, 0.94, 0.69, 0.66, and 0.76 mg/L at the 0.5 hr HRT, 2.86, 1.18, 0.96, 0.87, and 1.11 mg/L at the 1.0 hr HRT, and 5.30, 2.44, 1.99, 1.77, and 2.01 mg/L at the 2.0 hr HRT, respectively. The TAN removal efficiencies of the RBC at the rotational speeds of 1, 2, 3, 4, and 5 rpm were 32.9, 49.5, 65.1, 72.9, and 62.9% in 0.5 hr HRT,33.1, 74.1, 87.1, 95.8, and 78.5% in 1.0 hr HRT, and 35.5, 76.7, 89.6, 97.0, and 85.5% in 2.0 hr HRT, respectively. TAN removal efficiency of RBC per pass increased with increasing HRT. However, TAN concentration in the system also increased. The best operating condition among the treatments was obtained at the treatment of 0.5 hr HRT and 4 rpm (P<0.05). The TAN concentration was 0.66 mg/L. Concentrations of nitrite nitrogen (NO$_2$$^{[-10]}$ -N) in the system decreased with increasing rotational speed in all HRT while that in the system increased with increasing HRT in all rotational speeds. The ranges of NO$_2$$^{[-10]}$ -N concentrations at HRT of 0.5, 1.0, and 2.0 hr in the system were 0.26~0.32, 0.31~0.56, and 0.43~l.45 mg/L, respectively. The ranges of daily removal rates of TAN in this system were 20.03~23.0 g TAN/㎥ㆍday and those of nitrite nitrogen were 19.65~30.25 g NO$_2$$^{[-10]}$ -N/㎥ㆍday.

Dynamic Response of 50kW Turbo-Generator with Super Critical Rotor supported on a Squeeze Film Damper- Bearing (스퀴즈필름 댐퍼-베어링에 장착된 50kW 터보 제너레이터 초임계 로터의 동적응답)

  • 최상규;김영철;이동환
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.05a
    • /
    • pp.521-527
    • /
    • 2001
  • The dynamic performance analyses and tests for a 50kW turbo-generator (KIMM-TG50) were carried out. The operating concept of this machine is that it gets the initial driving force from the built-in motor-generator until it reaches its self-sustaining speed of 40,000 rpm, and then the driving mode is changed to self-operating mode by the combustor installed between the centrifugal compressor and the turbine. Due to winding mistake of motor-generator, the system could go only up to 22000 rpm by the motor so that high pressure air externally fed into the turbine was utilized to get the system to run up to 62,000 rpm thereafter. The vibration data collected during the tests revealed that the first bending critical speed is in near 5,600 rpm as predicted in the design stage of the rotor-bearing system, and that there were no other identifiable critical speeds up until 62,000 rpm due to high damping from the squeeze film damper-bearings supporting the rotor. This paper presented some of the experimental results along with dynamic performance predictions made in the design stage as a part of progress being made.

  • PDF

Design of an Automatic Winch System for Small Fishing Vessel (소형 어선의 자동 권양 윈치시스템 설계)

  • 이대재;김진건;김병삼
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.36 no.3
    • /
    • pp.157-165
    • /
    • 2000
  • A small hydraulic winch system with an automatic tension control unit was designed to improve the work efficiency of coastal small vessels and the dynamic response characteristics of the winch system operated in the open loop condition was investigated. The inlet and the outlet pressures in hydraulic motor, the torque and the rotating speed of winch drum were measured as a function of time, and the behaviour in autotension mode for stepped load changes was analyzed. The results obtained are summarized as follows : 1. The developed winch system for coastal small vessels will result in better fishing with improved efficiency and lower manpower consumption by remote control of winch system. 2. The rotating delay times of winch drum for on/off operations of solenoid valve were 0.09 see at CW mode and 0.04 sec at CCW mode, respectively. After the solenoid valve was controlled, response characteristics were unstable slightly but showed good tracking behaviour over short time. 3. The driving torque of winch system in autotension mode was kept almost constant of 55.9 kgf·m, and 11.1 then the rotating speed of winch drum was kept almost constant of 5.1 rpm in the larger torque than 55.9 kgf·m and 11.1 rpm in the lower torque than that. 4. The 5% settling times in the transient response characteristics of autotension mode under rapid increasing and decreasing conditions of load were 0.12 sec and 0.2 sec, respectively, and then the rotating speeds were 11 rpm and 5.3 rpm, respectively. 5. The tracking behaviour of torque and rotating speed by remote control operation were stable within 0.23 sec at CW mode and 0.37 sec at CCW mode, respectively.

  • PDF

Feed Rate Control for the Head-Feed Thresher (수급식탈곡기(穗給式脫穀機)의 공급율제어(供給率制御)(III) -제어(制御)시스템의 응답실험(應答實驗)-)

  • Choi, Y.S.;Chung, C.J.
    • Journal of Biosystems Engineering
    • /
    • v.16 no.2
    • /
    • pp.148-158
    • /
    • 1991
  • This study was undertaken to develop the feed rate control system for the head feed thresher by making use of the microprocessor and to evaluate the response of the system to a various threshing conditions. It was verified the performance of the control system through experiments. Control conditions were determined based on the simulation results of control system. The control system set at RH=500rpm, RL=480rpm for the bundle feed was considered optimum to give a high threshing capability and still to stabilize the feeding seed regardless of the bundle size. The control system for the continuous spread feed set at the range of LH=15mm, and LL=12mm gave a high control performance for the feeding mass of 1.1Kg/m and lower tested. In addition, the feed rate proportionality constant should be set lower than one in order to keep the rotational speed of threshing cylinder within the range of 500~520rpm.

  • PDF

Experimental of the Rotaing Cryogenic System (회전하는 극저온 시스템의 단열 특성에 관한 실험적 연구)

  • 이창규;정상권
    • Progress in Superconductivity and Cryogenics
    • /
    • v.2 no.1
    • /
    • pp.7-13
    • /
    • 2000
  • A rotating cryogenic system was designed similar to the cooling system for the rotor of a superconducting generator. The experimental rotor has an inner vessel which simulates the winding space of an actual superconducting rotor, and a torque tube of comparable design. This paper describes the evaluation of the total heat leak into the inner vessel that leads to the study of the heat transfer characteristic of the rotating cryogenic system. To examine the insulation performance of the experimental rotor. temperature was measured at each part of the system at various rotaing speeds from 0 rpm to 600 rpm. Total heat leak into the inner vessel was calculated by measuring the boil-off rate of liquid helium. Conduction heat leak to the inner vessel was obtained by the vent tube, and radiation heat leak was calculated by subtracting the conduction heat lent from the total heat leak. There seemed to be no rotaional dependency of total heat leak at least up 600 rpm.

  • PDF

Development of Automatic Backwashing Treatment System for Ballast Water (자동역세척 여과장치를 이용한 선박 밸러스트수 처리)

  • Park Sang-Ho;Lim Jae-Dong;Kim In-Soo
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2005.10a
    • /
    • pp.181-185
    • /
    • 2005
  • The treated ballast water from previous treatment contains microorganisms and pathogenic organisms in an filtration treatment system. The advantage of this process can be filtrated to minimize the demage to screen clogging of drum filter with sweeping the solids off rotating the surface of the filter. Another advantage is to drop off the solids with controlling revolution of drum screen in pretreatment filtration process. Also the fact that it is easy to attach and detach a several type of screen for getting the expected water quality is another advantage, too. Filter rotation speed at 20rpmis 40.5cmHg and 40rpm is 36.6cmHg. Filter out impurities from ballast water over 60rpm is 35cmHg. Filtration system removal aquatic organism over $80{\mu}m$ in ballast water. This study shows that the filtration treatment system has a potential for the removal of ballast water.

  • PDF