• 제목/요약/키워드: ROOFTOP OF A BUILDING

검색결과 120건 처리시간 0.024초

중층형 생활한옥 모델시안 연구 - 청주 서운동의 사례를 중심으로 - (The Tentative Plans of Middle-rise Traditional Houses (Han-ok) Located on Seoun-dong in Urban Area of Cheongju, Korea)

  • 김찬구;김태영
    • 한국농촌건축학회논문집
    • /
    • 제24권2호
    • /
    • pp.21-28
    • /
    • 2022
  • Focusing on the creation of a new han ok, especially a mid-rise hybrid-structured Han-ok, this study proposes a middle-rise (four-story) Han-ok on one and two lots located in Seoun-dong, the existing Han-ok intensive housing site in downtown Cheongju. 1) In terms of layout and function, according to the existing L-shaped Han-ok corresponding to the road and the direction, the parking lots and shops on the 1st floor, the business facility on the 2nd floor, the Han-ok on the 3rd and 4th floors are placed. There are yards, open roof yards, and semi-open Daecheong(大廳, main hall), which can be shared by residents. 2) In terms of structure and form, one or two floors (some 3 floors) are 5.4m square and 5.4×6.6m modules of the RC(Reinforced Concrete) group, and the upper floor reflects the 2.7m module, size and shape of the existing Han-ok. By extending the outer wall of the RC group in the lower floors (1st to 3rd floors) to the wooden exterior of the upper floors (2nd to 4th floors), it is attempted to avoid the awkward appearance of the RC group being exposed to wooden structures. And it is also attempted to reflect the wooden shape and design elements through the elevation elements such as horizontal windows, corner windows, picture frames, and vertical slits. 3) In environmental control and facilities, it is attempted to smooth the ventilation of the building by forming a vertical upward airflow from the dark space of the low floor to the positive of the upper floor. This doubles the effect through a vertical rise of cold air generated in a narrow alleyway, piloti parking lot, and the various voids. In addition to the Daecheong and Numaru(loft) of Han ok, the rooftop yard, the terrace, and the balcony, horizontal natural ventilation is generated through divided doors and transom windows.

도심형 에너지 자립 스마트팜 서비스 모델 설계 및 구축 (Design and Construction of Urban-type Energy Self-Supporting Smart-Farm Service Model)

  • 김관형
    • 한국정보통신학회논문지
    • /
    • 제23권10호
    • /
    • pp.1305-1310
    • /
    • 2019
  • 현대의 농업은 자원위주의 농업에서 과학기술 위주의 농업으로 변하고 있다. 과학기술이 융합된 농업은 새로운 신성장 동력으로 인식하고 있으며, 지능적인 스마트팜을 구축하기 위하여 정부 및 지방자치단체, 연구소, 산업계가 협력하여 스마트팜에 필요한 각종 장치를 개발하여 보급하고 있다. 최근에는 클라우드 플랫폼을 구축하여 보다 지능적인 농업환경을 구축하는 연구가 진행되고 있다. 본 논문에서는 도시의 건물 옥상을 활용하여 여가시간의 활용과 농업활동을 체험할 수 있는 도심형 에너지 자립 스마트팜 구축방안을 제시한다. 또한, IT 기술을 활용하여 스마트팜의 다양한 데이터를 원격지 서버에서 데이터를 관리하고 스마트팜 내부 환경을 제어할 수 있는 HMI 모듈을 개발하여 자동 또는 반자동으로 스마트팜을 관리하도록 한다. 서비스 모델은 모바일 기반으로 스마트팜의 내부 환경을 관리할 수 있는 모델을 제시한다.

태양의 위치에 따른 광파이프 시스템의 실내 주광환경평가 (Assessment of Daylight Environment on Light Pipe System Under Different Solar Position)

  • 신화영;김정태
    • 한국태양에너지학회 논문집
    • /
    • 제28권6호
    • /
    • pp.78-86
    • /
    • 2008
  • The aim of this paper is to show the daylight environment of a light pipe system according to sun movement. A light pipe system has been mounted on the roof of the windowless full scale model: the solar spot has diameter of 0.65m and is 1.3m long, giving an aspect ratio of 1:2. The full scale model was installed on the rooftop of the SHINAN apartment in Yongin city that has no obstructions against sunlight. The test room is equipped with sensors for the measurements of the internal illuminance and has an area of 6m(W)$\times$6m(D)$\times$4m(H). The system has been monitored with a data-logger to evaluate the cumulative distribution of illuminance on a floor-plane from 16th, April to 29th, May, 2008 over one month and selected clear sky condition. For the daylight performance of floor area, the totally 49 measuring points has been used to determine the internal illuminance and an HP datalogger(HP34970A) records the measurements for one consecutive month. The horizontal external illuminance has been measured with two outdoor sensors. This paper presents the results of monitoring light pipe system with internal/external illuminance ratio and cumulative frequency distribution of floor-plane illuminance are discussed The results show that lightpipe is proficient device for introducing daylight into the building. However It provided different daylight indoor environment with wide or narrow Interquatile range of illuminance, internal/external illuminance ratio and cumulative frequency distribution according to solar positions under suuny sky condition. For more achieving the improvement of lightpipes also include energy savings, user visual comfort with various indicators; seasonal solar height, room and lightpipes geometries.

건축물 일체형 도시농업에서 딸기와 강낭콩 공영식재에 따른 생육 특성 (Growth Characteristics of Strawberry and Kidney Bean Companion Planting in Building-integrated Urban Agriculture)

  • 이현아;이선영;윤용한;주진희
    • 한국환경과학회지
    • /
    • 제32권12호
    • /
    • pp.955-964
    • /
    • 2023
  • This study was conducted to obtain basic data on efficient and eco-friendly crop cultivation for urban residents who enjoy urban agriculture as a hobby or leisure activity. We planted strawberry(Fragaria x ananassa)(S) and kidney bean (Phaseolus vulgaris var. humilis)(K) in different ratios to analyze the differences in soil environment, growth, physiology, and productivity, and to investigate the effects. Strawberry growth was optimal with S1K2 ratio, whereas the S1K1 ratio treatment showed the highest levels of physiology and productivity. In terms of growth and physiology, kidney beans tended to perform best in S1K2 treatment. The average number of productive pods was two, with a highest average value of 2.3 being recorded in S2K1 treatment planted with a high percentage of strawberries. In terms of growth, physiology, and prodctivity our findings indicate that it would be desirable to plant starwberries and kidney bean in a 1:1 ratio. However, considering the environmental characteristics of walls and rooftops, it is necessary to effectively manage crops suitable for these conditions. Furthermore, additional studies should be conducted to analyze the quality of fruits and seeds producted, both qualitatively and quantitatively in the future.

도시기온에 작용하는 입체적 토지피복의 영향 (Impacts of Three-dimensional Land Cover on Urban Air Temperatures)

  • 조현길;안태원
    • 한국조경학회지
    • /
    • 제37권3호
    • /
    • pp.54-60
    • /
    • 2009
  • 본 연구의 목적은 토지피복의 입체적 분포가 도시기온의 변화에 작용하는 영향을 구명하여 열섬현상 완화에 기여할 도시조경의 전략을 모색하는 것이다. 연구대상지는 서울시 24개 AWS 지점별 직경 300m 공간이었고, 대상공간의 여름철 에너지 수지 및 기온에 영향을 미칠 수 있는 다양한 변수의 자료를 구득하였다. 또한, 춘천시에서 연구목적을 고려한 6개 지점을 선정하여 기온을 실측하고, 기온변화에 더 민감하게 반응할 30m 소공간의 지점별 토지피복을 실사하여 서울시 의 경우와 비교하였다. 서울시 AWS 지점의 여름철 기온을 추정하는 단순회귀모델을 도출한 결과, 식생체적, 녹지면적, 건물체적, 건물면적, 인구밀도, 포장로면적 등의 변수가 통계적으로 유의하게 여름철 기온변화에 기여하는 것으로 나타났다. 이들 중 기온변화의 설명력이 가장 높은 변수는 식생체적과 건물체적이었다. 기온변화에 유의한 변수들을 조합하여 유도한 다중회귀모델에서도 식생체적과 건물체적의 양 변수가 통계적으로 가장 적합한 모델을 생성하였다. 이 다중회귀모델에 따르면 식생체적의 10% 증가는 기온을 약 0.14% 감소시킨 반면, 건물체적의 10% 증가는 기온을 0.26% 증가시켰다. 소공간스케일에서 실측한 춘천시의 여름철 기온과 토지피복 간의 상관성 역시, 기온은 식생체적, 녹지면적 등의 증가에 따라 감소하는 반면 하드스케이프 면적의 증가에 비례하여 상승하는 경향이었다. 식생체적 변수를 적용하여 가장 적합한 단순회귀모델을 도출한 결과, 소공간스케일의 여름철 기온은 서울시 AWS 지점의 단순회귀모델과 유사하게 식생체적을 10% 증가시킴에 따라 0.32%($0.08^{\circ}C$)씩 감소하였다. 본 연구에 근거하면, 여름철 기온저감을 지향하는 도시조경은 식생체적을 증가시키면서 동시에 건물체적을 감소시키는 전략이 요구된다. 서울시 AWS 지점의 기온변화에 기여하는 건물체적의 영향력은 식생체적보다 약 2배 큰 것으로 분석된다. 따라서, 자연지반에서는 다층식재를 추진하여 식생체적을 확충하되, 건물의 입체적 표면에 의한 대기 가열을 제어하기 위해 벽면과 옥상의 녹화로 식물의 차양 및 증발산 효과를 증진해야 한다.

몽골의 가정용 PV-ES 하이브리드 시스템 개발을 위한 연구 (The Study on Development of PV-ES hybrid system for Mongolian Household)

  • ;;박준형
    • 전기학회논문지
    • /
    • 제66권12호
    • /
    • pp.1905-1912
    • /
    • 2017
  • In recent years, Ulaanbaatar, a capital of Mongolia has witnessed major problem that air quality reaches hazardous level during the winter season. Coal combustion for heating of every house in "Ger" district is main reason. One way to reduce the air pollution is mass usage of electric heater. However, there are several difficulties such as overload and degradation of transformers and other equipment used in distribution and transmission systems as well as power shortage occurrence in evening peak period due to residential consumption. This study aims to contribute for solving the air pollution and power shortage problem in Mongolia. One possible solution could be distributed generation (DG) with photovoltaic (PV) penetration. In this study, PV with energy storage (ES) hybrid system to reduce peak load is analyzed. We proposed the suitable structure of PV-ES hybrid for Mongolian household, and suggested several operation scenarios. Optimal operation algorithm is carried out based on a comparison aspect from economical, grid impact and PV penetration possibility. The economic analyse shows annual income of 520USD, and has a payback period of 8 years for selected scenario. The proposed PV-ES system structure is verified by experimentation set on the building rooftop in city center. The suggested scenario is planned to apply for system in further research.

평균 방법이 도시 난류 플럭스에 미치는 영향 (Effects of Different Averaging Operators on the Urban Turbulent Fluxes)

  • 권태헌;박문수;이채연;최영진
    • 대기
    • /
    • 제24권2호
    • /
    • pp.197-206
    • /
    • 2014
  • The effects of different averaging operators and atmospheric stability on the turbulent fluxes are investigated using the vertical velocity, air temperature, carbon dioxide concentration, and absolute humidity data measured at 10 Hz by a 3-dimensional sonic anemometer and an open-path $CO_2/H_2O$ infrared gas analyzer installed at a height of 18.5 m on the rooftop of the Jungnang KT building located at a typical residential area in Seoul, Korea. For this purpose, 7 different averaging operators including block average, linear regression, and moving averages during 100 s, 300 s, 600 s, 900 s, and 1800 s are considered and the data quality control procedure such as physical limit check and spike removal is also applied. It is found that as the averaging interval becomes shorter, turbulent fluxes computed by the moving average become smaller and the ratios of turbulent fluxes computed by the 100 s moving average to the fluxes by the 1800 s moving average under unstable stability are smaller than those under neutral stability. The turbulent fluxes computed by the linear regression are 85~92% of those computed by the 1800 s moving average and nearly the same as those computed by 900 s moving average, implying that the adequate selection of an averaging operator and its interval will be very important to estimate more accurate turbulent fluxes at urban area.

외기유인형 주방·욕실 배기구의 기류측정 분석 (Analysis of Air Current Measurements at External Induction-Style Kitchen and Bathroom Vents)

  • 이용호;김성용;박진철;황정하
    • 한국태양에너지학회 논문집
    • /
    • 제32권6호
    • /
    • pp.76-84
    • /
    • 2012
  • This study conducted experiments to measure air currents in an experimental building according to external conditions, types of induction ducts, and types of internal sockets by applying an external induction duct comprised of inducing openings and lines and induction units to the kitchen and bathroom vents at the rooftop of a super high-rise apartment building in order to help to improve the venting performance. The study also proposed the optimization of the external induction-style kitchen and bathroom vents capable of wind power generation. (1) As for air current distribution according to vent velocity changes, it increased the venting performance of the kitchen and bathroom by 1.0m/s at vent velocity of 2.0m/s or higher and allowed for wind power generation. (2)As for air current distribution according to external velocity changes, it increased the venting performance of the kitchen and bathroom by 1.2m/s at external velocity of 2.0m/s or higher and allowed for wind power generation. (3)As for air current distribution according to wind direction changes($0{\sim}180^{\circ}$), it was favorable for higher vent velocity when the angle between the external induction duct direction and prevailing wind direction was within ${\pm}30^{\circ}$. (4)As for air current distribution according to induction duct type, the[M1] type combining the inducing openings and lines with the induction units recorded the highest improvement effects in the kitchen and bathroom venting performance by increasing vent velocity by 46%. (5)As for air current distribution according to the changing types of internal sockets where the main ducts of the kitchen and bathroom are connected to the external induction ducts, the venturi tube type[Sv] increased vent velocity by 66% based on the smoothest external inflow.

빗물-저농도 오수 하이브리드 시스템의 설계 및 운전 평가 : 서울대 39동 (Design and Operation of the Rainwater-Greywater Hybrid System : SNU No. 39 Building)

  • 심인태;박현주;김충일;정성운;한무영;남궁은
    • 대한환경공학회지
    • /
    • 제38권12호
    • /
    • pp.676-682
    • /
    • 2016
  • 본 연구에서는 빗물과 중수를 연계하여 각각의 단점을 극복하고 장점을 극대화 할 수 있는 빗물-저농도 오수 하이브리드 시스템을 설계하고 서울대학교에 설치하여 수량 및 수질 모니터링과 경제성을 평가하였다. 건물에서 발생하는 오수 중세면, 샤워용수를 중수로 선택하여 침지형 분리막과 오존산화 처리하였으며, 건물 옥상에서 집수된 빗물은 저류 후 처리수조로 이송되어 처리된 저농도 오수와 혼합되어 변기 세척용수로 공급하였다. 변기 세척용수 $3,979m^3$ 중 65%인 $2,599m^3$를 빗물 이용과 저농도 오수를 재이용하였다. 빗물은 총대장균을 제외한 나머지 항목에서 중수도 수질 기준을 만족하였으며, 저농도 오수는 탁도, SS, BOD, 총대장균이 기준치를 초과하여 침지형 분리막과 오존산화 처리하여 안정적인 수질을 유지하였다. 경제성 분석 결과, 빗물-저농도 오수 하이브리드 시스템은 B/C (Benefit-Cost Ratio) 비율이 1.11으로 사업의 타당성이 있다고 판단된다. 물 재이용시설의 이용확대를 위해 시설 운영에 따른 경제성을 높이기 위한 다양한 연구 및 정책적 지원이 필요하다.

관리조방형 옥상녹화의 식재모델별 표면온도 모니터링 (Temperature Monitoring of Vegetation Models for the Extensive Green Roof)

  • 윤희정;장성완;이은희
    • KIEAE Journal
    • /
    • 제13권5호
    • /
    • pp.89-96
    • /
    • 2013
  • Green roofs can reduce surface water runoff, provide a habitat for wildlife moderate the urban heat island effect, improve building insulation and energy efficiency, improve the air quality, create aesthetic and amenity value, and preserve the roof's waterproofing. Green roofs are mainly divided into three types : intensive, simple-intensive, and extensive. Especially, extensive roof environment is a harsh one for plant growth; limited water availability, wide temperature fluctuations, high exposure to wind and solar radiation create highly stressed environment. This study, aimed at extensive green roof, was carried out on the rooftop of the library at Seoul Women's Univ. from October to November, 2012 and from March to August, 2013. To suggest the most effective vegetation model for biodiversity and heat island mitigation, surface temperatures were monitored by each vegetation model. We found that herbaceous plants of Aster sphathulifolius, Aceriphyllum rossii and Belamcanda chinensis, shrub of Syringa patula 'Miss Kim', Thymus quinquecostatus var. japonica, Sedum species can mixing each other. Among them, the vegetation models including Sedum takesimense, Aster sphathulifolius, Thymus quinquecostatus var. japonica was more effective on the surface temperature mitigation, because the species have the tolerance and high ratio of covering, and also in water. Especially, in the treatment of bark mulching, they helped to increase the temperature of vegetation models. In the case of summer, temperature mitigation of vegetation models were no significant difference among vegetation types. Compared to surface temperature of June, July and August were apparent impact of temperature mitigation, it shows that temperature mitigation are strongly influenced by substrate water content.