• Title/Summary/Keyword: ROM data

Search Result 371, Processing Time 0.026 seconds

Design and Implementation of DDFS Including Gain-Phase Detector (Gain-Phase 추출 기능을 가진 FDFS의 설계 및 검증)

  • Do, Jae-Chul;Cho, Jun-Young;Lee, Tae-Ho;Song, Young-Suk;Choi, Chang;Park, Chong-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2001.11c
    • /
    • pp.334-337
    • /
    • 2001
  • In this paper we implemented DDFS and gam-phase dectector which use output of DDFS or any sinusoidal signal input to broaden the usability of DDFS. DDFS is composed of a 32 bits phase accumulator, phase increment registers, ROM and several registers for controlling the operations. It generates the digital data for sine wave up to the half of the clock frequency. To reduce the ROM size and increase the speed, we adopt the algorithms based on Taylor's series expansion method. Data at sparse phase intervals are stored in ROM and sine data between intervals are calculated in hardware. Function of Gain-Phase Extraction consists of sine lookup of DDFS and the optimized multipliers.

  • PDF

New Encoding Method for Low Power Sequential Access ROMs

  • Cho, Seong-Ik;Jung, Ki-Sang;Kim, Sung-Mi;You, Namhee;Lee, Jong-Yeol
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.13 no.5
    • /
    • pp.443-450
    • /
    • 2013
  • This paper propose a new ROM data encoding method that takes into account of a sequential access pattern to reduce the power consumption in ROMs used in applications such as FIR filters that access the ROM sequentially. In the proposed encoding method, the number of 1's, of which the increment leads to the increase of the power consumption, is reduced by applying an exclusive-or (XOR) operation to a bit pair composed of two consecutive bits in a bit line. The encoded data can be decoded by using XOR gates and D flip-flops, which are usually used in digital systems for synchronization and glitch suppression. By applying the proposed encoding method to coefficient ROMs of FIR filters designed by using various design methods, we can achieve average reduction of 43.7% over the unencoded original data in the power consumption, which is larger reduction than those achieved by previous methods.

The Effect of Motor Developmental Intervention on the SCM Muscle Thickness and Range of Motion in Subjects with Congenital Muscular Torticollis: A Pilot Study (운동발달 중재가 선천성 기운목 아동의 목빗근 두께와 목 운동범위에 미치는 영향)

  • Kim, Young-Min;Han, Jin-Tae;Lee, Eun-Ju
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.12 no.4
    • /
    • pp.133-138
    • /
    • 2017
  • PURPOSE: The purpose of this study was to investigate the effect of modified motor developmental intervention on the SCM muscle thickness and the range of motion (ROM) of neck in subjects with congenital muscular torticollis. METHODS: Thirteen subjects who had congenital muscular torticollis were participated in this study and they were offered the modified motor developmental interventions for 8 weeks by pediatric physical therapist. SCM thickness of affected and non-affected side and ROM of neck rotation were collected between before and after intervention. SCM thickness was measured by using Ultrasound Unit (IU 22, Ultrasound system, Philips, Netherlands) and ROM of neck was measured by using the goniometer (Arthrodial protractor, North coast, USA). Data were represented as means ${\pm}SD$. Paired t-test was used to determine the effect of interventions on the SCM muscle thickness and neck ROM. RESULTS: SCM thickness of affected side was significantly decreased after the modified motor developmental interventions and that of non-affected side was generally increased but it was not significantly difference between pre and post interventions. ROM of neck rotation and lateral flexion was significantly increased after interventions. CONCLUSION: These results suggested that the modified motor developmental interventions could improve the recovery of SCM muscle thickness and neck ROM.

Range of Motion and Isokinetic Strength of Hip Joint in the College Women with Idiopathic Genu Vara (특발성 내반슬 여대생의 고관절 가동범위와 등속성 근력)

  • Kim, Che-Young;Lim, Seung-Kil
    • The Journal of the Korea Contents Association
    • /
    • v.14 no.10
    • /
    • pp.210-217
    • /
    • 2014
  • This study is to present objective data for the approaches of therapeutic exercise for the correction of genu varum by making an analysis and a comparison of the hip joints' ROM and isokinetic muscles of the female college students with straight legs with those of a female college student with idiopathic genu varum. Additionally, the state of the adductor muscle's thighs and the deep muscles of the subjects with bowed legs were experimented and the equipment's effect and applicability was reviewed through the process of the movement of newly developed exercise equipment, Balloa(2013, Balloa/Adonia/Korea). As a result, a person with genu varum needs the height increasing method for increasing external rotation ROM of a hip joint and requires the exercise techniques to strengthen external rotator muscles and to inhibit the activity of internal rotator muscles of a hip joint. Balloa increases the external rotation ROM of a hip joint and strengthens gluteal muscles, deep muscles, and adductor muscles, and the equipment's function of muscle strengthening shows that the equipment is an effective corrective exercise for the patients of genu varum.

Effects of Modified Cross-body Stretching on Range of Motion in Glenohumeral Joint (수정된 크로스-바디 스트레칭이 오목위팔관절의 관절가동범위에 미치는 영향)

  • Koh, Eun-Kyung;Jung, Do-Young
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.10 no.4
    • /
    • pp.1-7
    • /
    • 2015
  • PURPOSE: The purpose of this study was to compare the effects of cross-body stretching (CBS) and modified cross-body stretching (MCBS) on the range of motion (ROM) of glenohumeral joint (GHJ) in healthy subjects. METHODS: Thirty subjects were randomly assigned to 1 of 2 groups: CBS group without stabilization of scapula (n=15) and MCBS group with stabilization of scapula (n=15). We measured horizontal adduction and internal rotation ROM of GHJ in pre- and post-intervention. The data were analyzed using the analyses of covariate (ANCOVA) and least significant difference (LSD) post hoc tests (p=.05). RESULTS: In the post-intervention, the MCBS group had a significantly greater increase in horizontal adduction ROM (mean ${\pm}$ SD, $11.46^{\circ}{\pm}0.83^{\circ}$) compared to the CBS group ($7.81^{\circ}{\pm}0.83^{\circ}$) (p=.007) and a greater increase in internal rotation ROM ($62.27^{\circ}{\pm}0.74^{\circ}$) compared to the CBS group ($59.20^{\circ}{\pm}0.74^{\circ}$) (p=.004). CONCLUSION: A single session application of an MCBS provides immediate more improvements in both horizontal adduction and internal rotation ROM than CBS. These results suggest that application of MCBS with stabilization of scapula may be a more useful to gain ROM of GHJ than CBS without stabilization of scapula.

The Effect of Proprioceptive Neuromuscular Facilitation Rehabilitation Exercise on Range of Motion, Pain, and Function of Breast Cancer Patients after Surgery (고유수용성신경근촉진법 재활운동이 수술 후 유방암 환자의 관절운동범위와 통증 및 기능에 미치는 영향)

  • Kang, Tae-Woo
    • PNF and Movement
    • /
    • v.16 no.1
    • /
    • pp.133-141
    • /
    • 2018
  • Purpose: This study examined the effect of proprioceptive neuromuscular facilitation (PNF) rehabilitation exercise on postoperative range of motion (ROM), pain, and function of breast cancer patients. The purpose of this study was to provide fundamental data regarding the use of PNF rehabilitation exercise for patients with breast cancer. Methods: Fourteen patients who underwent surgery due to breast cancer were randomly divided into an experimental group (n=7) that performed PNF rehabilitation exercise and a control group (n=7) that performed general rehabilitation exercise. Both groups performed the respective exercises for 30 minutes, five times a week for 4 weeks. For the measurement of ROM, the range of shoulder abduction was measured using a clinometer smartphone application. The shoulder pain and disability index (SPADI) was used to measure the level of pain and functional activity. A paired t-test was conducted to compare within-group changes before and after the PNF rehabilitation exercise. Differences between the experimental group and control group were analyzed by an independent t-test. For all tests, the level of statistical significance was set at ${\alpha}=0.05$. Results: After the exercise, there was a significant within-group change in the ROM and SPADI in both the experimental group and control group (p<0.01). There was also a significant between-group difference in the ROM and SPADI after the intervention (p<0.05). Conclusion: Rehabilitation exercise is generally applied as a treatment for patients with breast cancer after surgery and is relatively effective. The application of PNF rehabilitation exercise may be useful in such patients, considering its effects on ROM improvement, pain reduction, and functional enhancement.

Reliability Study of Measuring Range of Motion Glenohumeral Joint Internal Rotation With Pressure Biofeedback Stabilization

  • Hwang, Ui-jae;Ha, Sung-min;Jeon, In-chul;Jung, Sung-hoon;Choi, Kyu-hwan;Kim, Su-jung;Kwon, Oh-yun
    • Physical Therapy Korea
    • /
    • v.22 no.4
    • /
    • pp.62-70
    • /
    • 2015
  • The aims of the current study were to assess reliability of range of motion (ROM) measurement of glenohumeral internal rotation (GIR) with a pressure biofeedback stabilization (PBS) method and to compare the reliability between manual stabilization (MS) and the PBS method. In measurement of pure glenohumeral joint motion, scapular stabilization is necessary. The MS method in GIR ROM measurement was used to restrict scapular motion by pressing the palm of the tester's hand over the subject's clavicle, coracoid process, and humeral head. The PBS method was devised to maintain consistent pressure for scapular stabilization during GIR ROM measurement by using a pressure biofeedback unit. GIR ROM was measured by 2 different stabilization methods in 32 subjects with GIR deficit using a smartphone clinometer application. Repeated measurements were performed in two test sessions by two testers to confirm inter- and intra-rater reliability. After tester A performed measurements in test session 1, tester B's measurements were conducted one hour later on the same day to assess the inter-rater reliability and then tester A performed again measurements in test session 2 for confirming the intra-rater reliability. Intra-class correlation coefficient (ICC) (2,1) was applied to assess the inter-rater reliability and ICC (3,1) was applied to determine the intra-rater reliability of the two methods. In the PBS method, the intra-rater reliability was excellent (ICC=.91) and the inter-rater reliability was good (ICC=.84). The inter-rater and intra-rater reliability of the PBS method was higher than in the MS method. The PBS method could regulate manual scapular stabilization pressure in inter- and intra-rater measuring GIR ROM. Results of the current study recommend that the PBS method can provide reliable measurement data on GIR ROM.

A practial design of direct digital frequency synthesizer with multi-ROM configuration (병렬 구조의 직접 디지털 주파수 합성기의 설계)

  • 이종선;김대용;유영갑
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.21 no.12
    • /
    • pp.3235-3245
    • /
    • 1996
  • A DDFS(Direct Digital Frequency Synthesizer) used in spread spectrum communication systems must need fast switching speed, high resolution(the step size of the synthesizer), small size and low power. The chip has been designed with four parallel sine look-up table to achieve four times throughput of a single DDFS. To achieve a high processing speed DDFS chip, a 24-bit pipelined CMOS technique has been applied to the phase accumulator design. To reduce the size of the ROM, each sine ROM of the DDFS is stored 0-.pi./2 sine wave data by taking advantage of the fact that only one quadrant of the sine needs to be stored, since the sine the sine has symmetric property. And the 8 bit of phase accumulator's output are used as ROM addresses, and the 2 MSBs control the quadrants to synthesis the sine wave. To compensate the spectrum purity ty phase truncation, the DDFS use a noise shaper that structure like a phase accumlator. The system input clock is divided clock, 1/2*clock, and 1/4*clock. and the system use a low frequency(1/4*clock) except MUX block, so reduce the power consumption. A 107MHz DDFS(Direct Digital Frequency Synthesizer) implemented using 0.8.mu.m CMOS gate array technologies is presented. The synthesizer covers a bandwidth from DC to 26.5MHz in steps of 1.48Hz with a switching speed of 0.5.mu.s and a turing latency of 55 clock cycles. The DDFS synthesizes 10 bit sine waveforms with a spectral purity of -65dBc. Power consumption is 276.5mW at 40MHz and 5V.

  • PDF

Effects of the Flex-OA Functional Shoe and the Standardized Shoe on Ranges of Hip and Knee Joint During Gait in Healthy Individuals (정상 성인에서 Flex-OA 기능성 신발과 일반 신발이 보행 중 엉덩관절과 무릎관절의 가동범위에 미치는 효과)

  • Kim, Yongwook
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.6 no.3
    • /
    • pp.33-42
    • /
    • 2018
  • Purpose : The purpose of this study was to investigate the characteristics of the Flex-OA shoe, a specific functional shoe, in terms of the range of motion (ROM) of hip and knee joint during walking when compared to a standardized shoe. Methods : Twenty-six healthy adults (18 males, 6 females) participated in this study. Subjects performed 8 walking trials consisting of two different shoe conditions to evaluate the hip and knee ROM using a three-dimensional motion capture system. Visual 3D motion analysis software was finally used to coordinate the kinematic data. Result : The total ROM and maximal abduction range of the hip joint in the coronal planes when wearing the Flex-OA shoe were significantly increased during walking compared to wearing a standard shoe (p<.05). On the other hand, significantly increased ROM was observed in the sagittal plane when wearing the Flex-OA shoe in the knee joints compared to a standard shoe (p<.05). Conclusion : Although clinical application of the specific functional shoe has known clearly positive effects on knee moments, the results of this study could provide important clues to explain the background of these effects in terms of the hip and knee joints when applying a specific functional shoe.

The Effects of Air-Pressure Cervical Traction Treatment on Forward Head Posture, ROM and Pain in the Tension Headache in the Adults (성인의 긴장성 두통에 에어견인요법이 앞쪽머리자세와 ROM 및 통증에 미치는 영향)

  • Cho, Namjeong;Lee, Soljae
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.2 no.4
    • /
    • pp.9-17
    • /
    • 2014
  • Purpose : The purpose of this study was to ascertain the effects of air-pressure cervical traction on the tension headache in the adults. Method : All subjects were treated with air-pressure cervical traction while 15 minutes a day, 3 times per week, for 4 weeks. The effects of air-pressure cervical traction were evaluated by HIT-6(headache impact test), VAS, and flexion, extension, left right flexion, left right rotation of cervical ROM. The measured data were analyzed by using repeated ANOVA. Especially in order to investigate the effect of air-pressure cervical traction. The comparison with among three measurement time. Results : The results of this study were as follows; 1) Prior and two weeks measurement did not show significant differences. The head forward posture than before the experiment, each experimental group was significantly increased(p<.05). 2) Prior and two weeks measurement did not show significant differences. The experimental group than ever cervical ROM of the movable range increased significantly(p<.05). 3) The experimental group was significantly lower than before the VAS(p<.05). 4) HIT score of the experimental group was significantly lower than before(p<.05). Conclusion : These findings suggest that air-pressure cervical traction had effect on the tension headache in the adults.