• Title/Summary/Keyword: ROM data

Search Result 374, Processing Time 0.025 seconds

Application of POD reduced-order algorithm on data-driven modeling of rod bundle

  • Kang, Huilun;Tian, Zhaofei;Chen, Guangliang;Li, Lei;Wang, Tianyu
    • Nuclear Engineering and Technology
    • /
    • v.54 no.1
    • /
    • pp.36-48
    • /
    • 2022
  • As a valid numerical method to obtain a high-resolution result of a flow field, computational fluid dynamics (CFD) have been widely used to study coolant flow and heat transfer characteristics in fuel rod bundles. However, the time-consuming, iterative calculation of Navier-Stokes equations makes CFD unsuitable for the scenarios that require efficient simulation such as sensitivity analysis and uncertainty quantification. To solve this problem, a reduced-order model (ROM) based on proper orthogonal decomposition (POD) and machine learning (ML) is proposed to simulate the flow field efficiently. Firstly, a validated CFD model to output the flow field data set of the rod bundle is established. Secondly, based on the POD method, the modes and corresponding coefficients of the flow field were extracted. Then, an deep feed-forward neural network, due to its efficiency in approximating arbitrary functions and its ability to handle high-dimensional and strong nonlinear problems, is selected to build a model that maps the non-linear relationship between the mode coefficients and the boundary conditions. A trained surrogate model for modes coefficients prediction is obtained after a certain number of training iterations. Finally, the flow field is reconstructed by combining the product of the POD basis and coefficients. Based on the test dataset, an evaluation of the ROM is carried out. The evaluation results show that the proposed POD-ROM accurately describe the flow status of the fluid field in rod bundles with high resolution in only a few milliseconds.

A Study on the Development of the Portable Intelligent QT Analyzer (휴대용 Intelligent QT 분석기의 개발에 관한 연구)

  • 이경중;민혜정
    • Journal of Biomedical Engineering Research
    • /
    • v.11 no.1
    • /
    • pp.57-64
    • /
    • 1990
  • This study describes the design of the portable intelligent QT analyzer which can record and analyze the ambulatory ECG data. System hardware is consisted of the one chip microcomputer(80C31) , A/D, ROM, RAM, LCD display and preamplifier. ECG data were processed by the differentiator and the digital filter. The de- tection of the parameters-QT, QTP and RR interval-was accomplished by the software algorithm using the slope and the amplitude of the processed data. Using this system, the trends of the parameters obtained during the long term could be observed.

  • PDF

A Study on the Utilization of Computer Program for the Prediction of Rom Acoustics (실내음향 예측을 위한 컴퓨터 프로그램 이용에 관한 연구)

  • 김선우;최형욱;한명호
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.250-255
    • /
    • 1997
  • The computer simulation and mock-up test are recently applied to the practical design for the room acoustics to predict and evaluate its characteristics. In this paper, the sound field properties predicted and evaluated by the computer simulation were compared to the measured data. Comparison and analysis between simulation data and measured data were performed for the Reverberation Time, Sound Pressure Level at the various measuring positions and frequencies and Definition, Early Decay Time, Speech Transmission Index.

  • PDF

Design of Digital Filter One Chip I.C (DIGITAL FILTER ONE CHIP I.C.화 및 제작)

  • Park, Sang-Bong;Pack, In-Cheon;Park, Noo-Kyeong;Moon, Dait-Chul;Tchah, Kyun-Hyon
    • Proceedings of the KIEE Conference
    • /
    • 1987.07b
    • /
    • pp.1495-1498
    • /
    • 1987
  • This paper described the design of register part, ROM and entire digital filter implementation by merging with ALU, control part last year. The register part consists of shift register, parallel load serial output register, multiplexer and selector, and we designed specially the 1024 memory cells ROM and decoder to decode the register data. Also, presented scaling algorithm to prevent the overflow.

  • PDF

Effect of Particle Contamination on Objective Lens in a CD-ROM Drive on Laser Diode Power and Photo Diode RF Signal (CD-ROM 드라이브의 대물렌즈 입자오염이 Laser Diode의 Power와 Photo Diode의 RF Signal에 미치는 영향)

  • Pae, Yang-Il;Hwang, Jung-Ho
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.1429-1434
    • /
    • 2003
  • A number of dust particles are intruded into ODD(Optical disk drive) due to the flow caused by disk rotation and are adhered to a lens or disk surface. The space between the disk and the lens is being reduced. Someone indicates the problems of this drive that are relatively small data storing capacity and slow access time. In recent, the problems of this optical disk drive mentioned above are being solved by adding the speed of the disk's revolution, making the actuator high-speed or light, and making the beam spot size smaller than making the space narrow between disk and lens. These particle contamination affects seriously RF Signal, readout signal in an ODD. Especially, the affected parts by a particle contamination in an ODD's readout signal are objective lens and media.

  • PDF

Physical Therapy After Total Knee Replacement (A Comparison of Two Physical Therapy Techniques) (슬관절 전치환술 후의 물리치료)

  • Jang, Moon-Heon;Ko, Joo-Yeon
    • Journal of Korean Physical Therapy Science
    • /
    • v.5 no.4
    • /
    • pp.809-816
    • /
    • 1998
  • This study was conducted to evaluated the effects adding continuous passive motion(CPM) each day to the entire postoperative program of patients who received a total knee replacement(TKR). A retrospective chart review was completed for 31 patients(12 with bilateral involvement, totaling 44 knees)who received a TKR between 1996 and 1998. The data analysis compared the following variables for 28 patients who received CPM and 16 patients who received no CPM: the length of hospital stay(LOS), the frequency of postoperative complications, the number of post-operative days(PODs) range of motion (ROM). The CPM Group showed significant decreases in the frequency of complication(p<0.05), the LOS(p < 0.05), and No difference was demonstrated in the ROM of the two groups. We concluded that CPM was an effective adjunct to physical therapy care of patients undergoing total knee replacement.

  • PDF

A study on high performance Java virtual machine for smart card (스마트카드용 고성능 자바가상기계에 대한 연구)

  • Jung, Min-Soo
    • Journal of the Korean Data and Information Science Society
    • /
    • v.20 no.1
    • /
    • pp.125-137
    • /
    • 2009
  • Smart card has a small sized micro computer chip. This chip contains processor, RAM, ROM, clock, bus system and crypto-co-processor. Hence it is more expensive, complicated and secure chip compared with RFID tag. The main application area of smart card is e-banking and secure communications. There are two kinds of smart card platforms; open platform and closed one. Java card is the most popular open platform because of its security, platform independency, fast developing cycle. However, the speed of Java card is slower than other ones, hence there have been hot research topics to improve the performance of Java card. In this paper, we propose an efficient transaction buffer management to improve the performance of Java card. The experimental result shows the advantage of our method.

  • PDF

The Effect of Static Stretching and Evjenth-Hamberg Stretching for Isokinetic Muscle Strength of Knee Joint (정적인 스트레칭과 Evjenth-Hamberg 스트레칭이 슬관절 등속성 근력에 미치는 효과)

  • Ko, Tae-Sung;Joung, Ho-Bal
    • The Journal of Korean Physical Therapy
    • /
    • v.18 no.5
    • /
    • pp.43-51
    • /
    • 2006
  • Purpose: The purpose of this study was to examine the effects of static stretching and Evjenth-Hamberg stretching on isokinetic muscle strength of knee flexors and extensors. Methods: The subjects were composed of eighty healthy males without weight-training experience. ROM of knee joint measured active maximal extension and isokinetic Peak Torque measured $60^{\circ}/sec,\;120^{\circ}/sec$ using an the En-Knee. Three tests(Baseline, 4 weeks, 8 weeks, respectively) was operated to examine change of each variable. Data were analyzed with a $2{\times}3$ analysis of variance ($group{\times}test$) for repeated measures on last factor by SPSS package 10.0. The data analysis revealed muscle strength were dependent on stretching method. Results: The results were as follows. First, Evjenth-Hamberg stretching(E-HS) was more effective than static stretching(SS) on ROM. Second, Peak Torque of knee flexors and extensors was improved in both methods by each time. but E-HS was more improved than SS. Conclusion: In conclusion, This study indicates that E-HS is more efficient than SS on muscle strength improvement.

  • PDF

Characteristics of Pelvic Ranges According to Artificial Leg Length Discrepancy During Gait: Three-Dimensional Analysis in Healthy Individuals (보행 중 인위적 다리길이 차이에 따른 3차원적 골반 가동범위의 특성)

  • Kim, Yongwook
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.7 no.2
    • /
    • pp.59-67
    • /
    • 2019
  • Purpose : The purpose of this study was to analyze the dynamic range of motion (ROM) of pelvic and translation of center of mass (COM) when wearing different shoe insole lifts according to leg length discrepancy (LLD) during free speed gait. Methods : Thirty-five healthy adults were participated in this study. Kinematic data were collected using a Vicon motion capture system. Reflective and cluster 40 markers attached to participants lower extremities and were asked to walk in a 6 m gait way under three different shoe lift conditions (without any insole, 1 cm insole, and 2 cm insole). The pelvic ROM and COM translation in three planes were sorted using a Nexus software, and a Visual3D motion analysis software was used to coordinate all kinematic data. Results : There were significantly increased maximal pelvic elevation and total pelvic range in coronal plane when wearing a standard shoe with 2 cm insole lift during gait (p<.05). When wearing a standard shoe with 2 cm insole lift, the total range of the pelvic segment were significantly different in all three motion planes (p<.05). Conclusion : Although LLD of less than 2 cm develops abnormal movement pattern of the pelvis and may cause of musculoskeletal diseases such as low back pain, hip and knee joint osteoarthritis, therefore intensive various physical therapy interventions for LLD are needed.

A Fast IFFT Algorithm for IMDCT of AAC Decoder (AAC 디코더의 IMDCT를 위한 고속 IFFT 알고리즘)

  • Chi, Hua-Jun;Kim, Tae-Hoon;Park, Ju-Sung
    • The Journal of the Acoustical Society of Korea
    • /
    • v.26 no.5
    • /
    • pp.214-219
    • /
    • 2007
  • This paper proposes a new IFFT(Inverse Fast Fourier Transform) algorithm, which is proper for IMDCT(Inverse Modified Discrete Cosine Transform) of MPEG-2 AAC(Advanced Audio Coding) decoder. The $2^n$(N-point) type IMDCT is the most powerful among many IMDCT algorithms, however it includes IFFT that requires many calculation cycles. The IFFT used in $2^n$(N-point) type IMDCT employ the bit-reverse data arrangement of inputs and N/4-point complex IFFT to reduce the calculation cycles. We devised a new data arrangement method of IFFT input and $N/4^{n+1}$-type IFFT and thus we can reduce multiplication cycles, addition cycles, and ROM size.