ICR계 생쥐 1세포배를 이용한 수질의 평가 (Evaluation of Water Quality using ICR Mouse 1-cell Embryo)

  • 김충현;정경순;박소현;황도영;김기철;민응기
    • Clinical and Experimental Reproductive Medicine
    • /
    • 제21권1호
    • /
    • pp.63-68
    • /
    • 1994
  • To confirm the overcome of in vitro 2-cell block, ICR mouse I-cell embryos were cultured in CZB media. All embryos in CZB were overcome in vitro 2-cell block and 92% of embryos were developed to the blastocyst at day 4. However, in m-KRB group(control) only 20% of embryos were developed over 2-cell. Any embryos in m-KRB did not develop to the morular stage. Developments and degenerations of ICR mouse I-cell embryos were compared in CZB medium prepared with water of three quality:(l) Milli-Q ultrafiltration water(UF);(2) Milli-Q reverse osmosis water(RO);(3) tap water(TAP). The objective was to evaluate the potential of quality control using ICR mouse 1-cell embryos. The more water was purified, the better embryo developments were supported and the less embryos were degenerated. As a quality control system, the culture of ICR 1-cell mouse embryos in CZB was useful.

  • PDF

중공사막 외부표면의 제타전위 측정방법 고찰 (Measurements and methods for analyzing zeta potential of the external surface of hollow fiber membranes)

  • 이태섭;이상엽;이주희;홍승관
    • 상하수도학회지
    • /
    • 제23권3호
    • /
    • pp.353-362
    • /
    • 2009
  • A new method and equipment for measuring the zeta potential of the external surface of hollow fiber (HF) membranes is reported. An existing commercial streaming potential analyzer in conjunction with home-made test cells was used to determine the electrokinetic surface characteristics of various HF membranes. It was shown that measurements of the external surface of HF membrane using the home-made test cells designed in this study were easy and reliable. The zeta potential values were quite accurate and reproducible. By varying the physical shape of the test cells to adjust hydrodynamics inside the test cells, several upgrade versions of home-made test cells were obtained. It was shown that the zeta potential of the external surface of HF membranes was most influenced by membrane materials as well as the way of surface modification. However, the overall surface charge of tested HF membranes were much less than that of commercial polyamide thin-film-composite (TFC) reverse osmosis (RO) membranes due to the lack of surface functional groups. For the HF membranes with the same material, the effect of pore size on the zeta potential was not significant, implying the potential of accurate zeta potential measurements for various HF membranes. The results obtained in this study are expected to be useful for better understating of electrokinetic surface characteristics of the external surface of HF membranes.

전처리 MF의 다양한 역세 공정을 적용한 하수재이용 파일럿 플랜트 연구 (Study of MF membrane as pretreatment option using various backwash process from wastewater reuse pilot plant)

  • 박광덕;박찬수;이창규;김종오;최준석
    • 상하수도학회지
    • /
    • 제30권3호
    • /
    • pp.335-341
    • /
    • 2016
  • Various studies have forwarded an outstanding wastewater effluent treatment systems toward securing sustainable supply of water sources. In this paper, a broad overview of the performance of MF membrane as pretreatment option for wastewater reuse will be presented based on the literature survey and experiments conducted over the wastewater reuse pilot plant. The pilot plant was operated with a continuous data acquisition for about 300days under various chemical enhanced backwash (CEB) system with subsequent treated water quality analysis. Accordingly, assessment of the effluent revealed that the pretreated water is suitable enough to be used as an input for Reverse Osmosis (RO) unit and significant effect of CEB and concentration of NaOCl is also conceived from the analysis. Moreover, it's also observed that the application of various CEB condition over long operational hours induced a constant declination of overall performance of MF membrane.

과황산나트륨을 이용한 내분비계장애물질 산화제거 (Oxidation of Endocrine Disrupting Chemicals Using Sodium Persulfate)

  • 임찬수;윤여복;김도군;고석오
    • 대한토목학회논문집
    • /
    • 제33권2호
    • /
    • pp.609-617
    • /
    • 2013
  • 본 연구에서는 역삼투 공정 농축수에 존재할 수 있는 내분비계 장애물질의 처리에 있어, 고급산화 공정의 적용가능성을 다양한 조건하에서 평가하였다. 오염물 제거에는 Fe(II)를 촉매로 한 과황산나트륨 산화를 이용하였으며, 초기 pH와 이온강도 등, 영향인자에 따른 산화능을 검토하였다. Fe(II) 촉매 과황산나트륨에 의한 $17{\alpha}$-ethynylestradiol(EE2) 제거효율은 초기 pH와 이온강도가 증가할수록 감소하였다. 반면, 이온강도 물질로 염소이온과 같은 할로겐족 이온을 적용 시 산화반응에 긍정적인 영향을 나타냈는데, 이는 라디칼 전이에 따른 영향으로 판단된다.

해수담수화 시설의 에너지 효율 향상을 위한 최적위치 검토 (The review of optimal location for enhanced energy efficiency in seawater desalination plant)

  • 심규대;장부건;박용균;정준연;김동균
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2019년도 학술발표회
    • /
    • pp.201-201
    • /
    • 2019
  • 세계적인 기상이변으로 가뭄발생 빈도 및 영향이 증가하고 있으며, 급속한 산업화로 사용 가능한 수자원이 점차 고갈되어 있어, 국내에서도 해수담수화(Seawater Desalination)는 새로운 대체수자원으로 많은 관심을 받고 있다. 해수담수에 필요한 에너지 약 50~70%는 역삼투(Reverse Osmosis) 공정에서 발생되며, 해수온도 및 염분도에 따라 많이 변동될 수 있으므로 국립해양조사원(KHOA)의 과거 20년 자료를 이용하여 해수담수화 시설물 위치에 따른 영향을 분석하였다. 해수담수화에 필요한 에너지는 막 제조사에서 제공하는 RO Projection Software를 적용하여 에너지 소모량을 평가하고, 이를 고려한 시설물 위치에 대한 평가 모델을 구축하였다. 기존 해수담수화 시설은 대규모 물 공급이 필요한 지역을 우선적으로 고려했기 때문에 시설물 위치에 대한 객관적인 평가기준 마련이 어려웠다. 그러나 해수담수화 플랜트는 한번 설치되면 장기적인 시설물 유지 및 관리가 필요함으로 경제성을 고려한 최적 입지의 선정은 매우 중요하다. 본 연구는 국립해양조사원의 수집된 자료를 바탕으로 해수담수화 시설물 입지선정을 정량적으로 평가함으로서, 시설물 위치에 대한 의사결정시 참고할 수 있는 기초자료로 활용될 것으로 기대한다.

  • PDF

Fouling behaviours of two stages microalgae/membrane filtration system applied to palm oil mill effluent treatment

  • Teow, Yeit Haan;Wong, Zhong Huo;Takriff, Mohd Sobri;Mohammad, Abdul Wahab
    • Membrane and Water Treatment
    • /
    • 제9권5호
    • /
    • pp.373-383
    • /
    • 2018
  • Fouling by solids and microorganisms is the major obstacle limiting the efficient use of membrane wastewater treatment. In our previous study, two stages microalgae/membrane filtration system was proposed to treat anaerobic digested palm oil mill effluent (AnPOME). This two stages microalgae/membrane filtration system had showed great potential for the treatment of AnPOME with high removal of COD, $NH_3-N$, $PO_4{^{3-}}$, TSS, turbidity, and colour. However, fouling behavior of the membrane in this two stages microalgae/membrane filtration system was still unknown. In this study, empirical models that describe permeate flux decline for dead-end filtration (pore blocking - complete, intermediate, and standard; and cake layer formation) presented by Hermia were used to fit the experimental results in identifying the fouling mechanism under different experimental conditions. Both centrifuged and non-centrifuged samples were taken from the medium with 3 days RT intervals, from day 0 to day 12 to study their influence on fouling mechanisms described by Hermia for ultrafiltration (UF), nanofiltration (NF), and reverse osmosis (RO) filtration mode. Besides, a more detailed study on the use of resistance-in-series model for deadend filtration was done to investigate the fouling mechanisms involved in membrane filtration of AnPOME collected after microalgae treatment. The results showed that fouling of UF and NF membrane was mainly caused by cake layer formation and it was also supported by the analysis for resistance-in-series model. Whereas, fouling of RO membrane was dominated by concentration polarization.

무우쥬스 농축액의 Rheological Properties (Rheological Properties of Radish Juice Concentrates)

  • 이세은;이부용;진재순;김동만;김길환
    • 한국식품과학회지
    • /
    • 제24권3호
    • /
    • pp.261-265
    • /
    • 1992
  • 무우쥬스 농축액의 저장성 및 활용성 증진을 위해 역삼투압법과 박막농축법 등을 이용하여 농축한 무우쥬스 농축액의 유통 특성을 조사한 결과는 다음과 같다. 무우쥬스 농축액은 약간의 의사가소성을 띠는 뉴턴유체의 흐름 특성을 보여주었다. 전단속도 1000(1/S)에서의 겉보기 점도는 1번 농축구(열처리 무우쥬스, 박막 농축구)가 0.0503Pa.s, 2번 농축구(생무우쥬스, 박막농축구)가 0.0578, 3번 농축구(열처리 무우쥬스, 역삼투압 농축구)가 0.0655Pa.s 값을 각각 나타내었다. 각 농축액 항복력은 $35{\sim}65^{\circ}Bx$에서 $0.0001{\sim}0.0580Pa$ 범위로 아주 적은 값이어서 power law model만 갖고도 흐름 특성의 해석이 가능하였으며 또한 Arrehenius식에 의해 구한 활성화에너지는 무우쥬스 농축액의 농도가 높아질수록 2.7057에서 $4.1159{\times}10^4KJ/kg.mol$로 증가하였다.

  • PDF

역삼투막 해수담수화 공정에서 에너지 회수장치의 운영인자 비교분석을 통한 에너지 효율 최적화 연구 (Optimization of energy efficiency through comparative analysis of factors affecting the operation with energy recovery devices on SWRO desalination process)

  • 김푸름;김형수;박준영;김태우;김민진;박기태;김지훈
    • 상하수도학회지
    • /
    • 제32권1호
    • /
    • pp.1-10
    • /
    • 2018
  • Recently, interest in the development of alternative water resources has been increasing rapidly due to environmental pollution and depletion of water resources. In particular, seawater desalination has been attracting the most attention as alternative water resources. As seawater desalination consumes a large amount of energy due to high operating pressure, many researches have been conducted to improve energy efficiency such as energy recovery device (ERD). Consequently, this study aims to compare the energy efficiency of RO process according to ERD of isobaric type which is applied in scientific control pilot plant process of each $100m^3/day$ scale based on actual RO product water. As a result, it was confirmed that efficiency, mixing rate, and permeate conductivity were different depending on the size of the apparatus even though the same principle of the ERD was applied. It is believed that this is caused by the difference in cross-sectional area of the contacted portion for pressure transfer inside the ERD. Therefore, further study is needed to confirm the optimum conditions what is applicable to the actual process considering the correlation with other factors as well as the factors obtained from the previous experiments.

폴리아마이드계 복합막을 이용한 염료 폐수 처리 공정 분리막 세척 조건 연구 (Study on the Membrane Cleaning-in-place (CIP) Conditions for the Dye Wastewater Treatment Process Using Polyamide Composite Membranes)

  • 제갈종건;이용환;황정은;정재윤
    • 멤브레인
    • /
    • 제18권1호
    • /
    • pp.94-102
    • /
    • 2008
  • 염색폐수처리를 위하여 피페라진, 메타페닐렌디아미, 트리메소일 클로라이드를 이용하여 계면중합법으로 폴리아마이드계 나노분리막과 폴리아마이드계 역삼투막을 제조하였으며, 이들을 오스모닉스사로부터 구입한 역삼투막의 투과특성과 비교하였다. 이들의 기본 분리투과특성 조사를 위하여 PEG 600, $Na_2SO_4$, NaCl 수용액을 이용하였으며, 제조된 분리막들은 전형적인 나노복합막과 저압용 역삼투막의 특성을 나타내었다. 제조된 이들 분리막들을 이용하여 국내 염료 제조업체인 (주)경인양행으로부터 공급된 실제 염색폐수를 처리하였으며, 이때 이들의 분리투과특성을 살펴보았다. 또한 분리막을 이용한 폐수처리 시 발생되는 분리막 오염을 제거하기 위하여 일정시간마다 CIP를 실시하였다. 이때 3종류의 서로 다른 화학세정제를 사용하였으며, 이들의 세척성능을 살펴보았다.

역삼투막 표면에 음이온 고분자 코팅을 통한 파울링 현상 감소연구 (Study on the Fouling Reduction of the RO Membrane by the Coating with an Anionic Polymer)

  • 조은혜;정성일;임지원
    • 멤브레인
    • /
    • 제22권6호
    • /
    • pp.481-488
    • /
    • 2012
  • 폴리아마이드 역삼투막 표면에 음이온 수용성 고분자인 poly(vinyl amine)(PVAm)을 코팅한 후 오염물질인 bovine serum albumin (BSA), humic acid (HA), sodium alginate (SA)에 대하여 파울링 개선효과가 있는지를 알아보고자 하였다. PVAm의 코팅과 파울링 여부는 scanning electron microscopy (SEM)을 통해 관찰하였다. BSA, HA, SA 100 ppm 공급원액을 이용하여 2, 4, 8 bar로 압력을 변화시켜 투과성능실험을 수행한 결과 PVAm으로 코팅되지 않은 막과 코팅된 막 모두 압력증가에 따라 파울링 현상이 심화되었으나 PVAm으로 코팅된 막이 BSA, HA, SA의 경우 모두에서 약 30%이상 투과도가 향상되어 파울링 개선효과가 나타나는 것을 확인할 수 있었다. HA > SA > BSA의 순으로 파울링 개선효과가 나타났으며 HA의 경우 가장 두드러지게 나타났다.