• Title/Summary/Keyword: RMS-DC converter

Search Result 65, Processing Time 0.021 seconds

Design and Reliability Evaluation of 5-V output AC-DC Power Supply Module for Electronic Home Appliances (가전기기용 직류전원 모듈 설계 및 신뢰성 특성 해석)

  • Mo, Young-Sea;Song, Han-Jung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.4
    • /
    • pp.504-510
    • /
    • 2017
  • This paper presents an AC-DC power module design and evaluates its efficiency and reliability when used for electronics appliances. This power module consists of a PWM control IC, power MOSFETs, a transformer and several passive devices. The module was tested at an input voltage of 220V (RMS) (frequency 60 Hz). A test was conducted in order to evaluate the operation and power efficiency of the module, as well as the reliability of its protection functions, such as its over-current protection (OVP), overvoltage protection (OVP) and electromagnetic interference (EMI) properties. Especially, we evaluated the thermal shut-down protection (TSP) function in order to assure the operation of the module under high temperature conditions. The efficiency and reliability measurement results showed that at an output voltage of 5 V, the module had a ripple voltage of 200 mV, power efficiency of 73 % and maximum temperature of $80^{\circ}C$ and it had the ability to withstand a stimulus of high input voltage of 4.2 kV during 60 seconds.

Thin-Film Chromel-Alumel Multijunction Thermal Converter with Low Output Resistance (저출력저항의 박막 크로멜-알루멜 다중접합 열전변환기)

  • Cho, Hyun-Duk;Kim, Jin-Sup;Shin, Jang-Kyoo;Lee, Jong-Hyun;Lee, Jung-Hee;Park, Se-Il;Kwon, Sung-Won
    • Journal of Sensor Science and Technology
    • /
    • v.9 no.4
    • /
    • pp.288-296
    • /
    • 2000
  • Thin-film chromel-alumel multijunction thermal converters with a low output resistance of $64{\sim}85\;{\Omega}$ showed approximately the square law-dependent input-output relation. The voltage responsivities were very low with $0.34{\sim}0.67\;V/W$ in air and $1.15{\sim}1.48\;V/W$ in vacuum, respectively, and the ac-dc voltage transfer error was very large with about +340 ppm in the frequency range of $40\;Hz{\sim}10\;kHz$ in the case of 1 V-input sinewave rms voltage. It can be concluded that the large transfer error of the thermal converter was mainly caused by the low voltage responsivity and the large heat loss due to low output resistance, which implies that the optimization for small ac-dc transfer error is required.

  • PDF

Characteristics of a Planar Multijunction Thermal Converter (평면형 다중접합 열전변환기의 특성)

  • Jo, Hyeon-Deok;Kim, Jin-Seop;Lee, Jong-Hyeon;Lee, Jeong-Hui;Park, Se-Il;Gwon, Seong-Won
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.38 no.10
    • /
    • pp.699-705
    • /
    • 2001
  • Six types of planar thermal converters from TC 1 to TC 6 were designed and fabricated for the purpose of being used as practical standards to alternating current. The respective voltage responses in air and in a vacuum of TC 6, which has the smallest thermal loss, were about 4.03mV/mW and about 6.38 mV/mW. Thermal time constant of TC 6, which has also the smallest heater thermal inertia, was about 8 ms. The respective variations of AC-DC voltage and current transfer errors from sample to sample, which were measured by FRDC(fast reversed DC) method, were about $\pm$0.41 ~$\pm$0.85 ppm and about $\pm$0.15~$\pm$1.16 ppm in the frequent range of 40 Hz~10 KHz with appling 1 V and 5 mA rms sine waves to the converters. All converters investigated exhibited sufficiently low AC-DC transfer errors to be used as practical standards.

  • PDF

Analysis and measurement of low frequency magnetic field according to internal position of electric railway train (전기철도차량 객실 내부 위치에 따른 극저주파 자계 측정 및 분석)

  • Jang, Dong-Uk;Han, Moon-Seob
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.489-494
    • /
    • 2008
  • The measurement of magnetic field is performed about DC and AC magnetic field in electric railway line. The test point is cap, on the converter/inverter box, on the traction motor and on the SIV, the height of measurement is bottom and 60 cm height. In case of AC magnetic field, the selected specific frequency is measured on the converter/inverter box. The AC magnetic field is checked and analysis through BNC output, DAQ cad and notebook PC.

  • PDF

Development of New Device for the Rapid Measurement of the freshness of Wet Fish by Using Micro Computer (마이크로 컴퓨터를 이용한 어육의 신선도 측정장치의 개발)

  • CHO Young-Je;LEE Nam-Geoul;KIM Sang-Bong;CHOI Young-Joon;LEE Keun-Woo;KIM Geon-Bae
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.28 no.3
    • /
    • pp.253-262
    • /
    • 1995
  • To develop a device for measuring fish freshness which could be move accurate and reliable than used freshness measuring systems. A new device based on digital circuit was designed using a microcomputer. The device was composed of a sensor part, 8096 microprocessor and a segment display. The effectiveness of device has been evaluated by the coefficient of correlation among the measured freshness stores such as electrical Q-value, K-value and amount of volatile basic nitrogen (VBN) of plaice, Paralichthys Olivaceus, during storage at $-3^{\circ}C,\;0^{\circ}C,\;5^{\circ}C,\;10^{\circ}C,\;and\;25^{\circ}C$. Q-values measured by a new device were more closely correlated with K-value (r=-0.978-\;-0.962,\;p<0.05) and VBN (r=-0.888-\;-0.988,\;p<0.05) in case of plaice meat. If more data would achieve using various fishes, this new designed device could be a valuable kit in fish market by its compact portability.

  • PDF