• 제목/요약/키워드: RMS-DC converter

검색결과 65건 처리시간 0.026초

A High-Efficiency High-Power Step-Up Converter with Low Ripple Content

  • Kang Jeong-il;Roh Chung-Wook;Moon Gun-Woo;Youn Myung-Joong
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.708-712
    • /
    • 2001
  • A new phase-shifted parallel-input/series-output (PI SO) dual inductor-fed push-pull converter for high-power step­up applications is proposed. This converter is operated at a constant duty cycle and employs an auxiliary circuit to control the output voltage with a phase-shift between the two modules. It features a voltage conversion characteristic which is linear to changes in the control input, and high step-up ratio with a greatly reduced switch turn-off stress resulting in a significant increase in the converter efficiency. It also shows a low ripple content and low root-mean-square (RMS) current in the output capacitor. The operational principle is analyzed and a comparative analysis with the conventional pulse-width-modulated (PWM) PISO dual inductor-fed push-pull converter is presented. A 50kHz, 800W, 350Vdc prototype with an input of 20-32Vdc has also been constructed to validate the proposed converter. The proposed converter compares favorably with the conventional counterpart and is considered well suited to high-power step-up applications.

  • PDF

변압기의 이상 신호 데이터를 축적하기 위한 원거리 진단 시스템 개발 (Development of Remote Diagnosis System to Accumulate Abnormal Signal Data of Transformer)

  • 곽승수;김용신
    • 한국컴퓨터정보학회:학술대회논문집
    • /
    • 한국컴퓨터정보학회 2019년도 제60차 하계학술대회논문집 27권2호
    • /
    • pp.161-162
    • /
    • 2019
  • 본 논문에서는 변압기의 이상 신호 데이터를 원거리에서 축적하기 위한 이상 신호 진단 시스템을 제안한다. 이 시스템은 원격으로 변압기의 이상 신호를 수집하여 변압기의 이상을 알아낼 수 있다. 이 시스템은 상용된 통신 모듈의 느린 통신 속도를 고려하여 이상 신호를 RMS-DC 값으로 변환하는 작업을 추가하였다.

  • PDF

2대의 임베디드 Z-소스 컨버터를 이용한 단상 DC-AC 인버터 (A Single-Phase DC-AC Inverter Using Two Embedded Z-Source Converters)

  • 김세진;정영국;임영철;최준호
    • 전기학회논문지
    • /
    • 제60권6호
    • /
    • pp.1152-1162
    • /
    • 2011
  • In this paper, a single-phase DC-AC inverter using two embedded Z-source converters is proposed. The proposed inverter is composed of two embedded Z-source converters with common DC source and output AC load. The output AC voltage of the inverter is obtained by the difference of output capacitor voltages of each converter. The output voltage of each converter take shape of the asymmetrical AC waveform centering zero voltage. Therefore, the proposed inverter can generate the same output voltage despite low VA rating L-C elements, compared to the conventional inverter using high DC voltage with AC ripple. To verify the validity of the proposed system, the PSIM simulation was achieved under the condition of rapid increase of DC source (110[V]${\rightarrow}$150[V]) and R-load (50[${\Omega}$]${\rightarrow}$300[${\Omega}$]). For controlling the voltage of the inverter system, the one-cycle controller was adopted. As results, the proposed inverter output the constant AC voltage (220[V]rms/60[Hz]) for all conditions. Also, the R-L load and nonlinear diode load were adopted for the proposed inverter loads, and we could know that the its output voltage characteristics were as good as the pure R-load. Finally, the RMS and THD of output AC voltage were examined for the different loads, input DC voltages and reference voltage signals.

디지털 샘플링 방법을 사용한 교류전압과 전류의 (Traceable AC Voltage and Current Measurements Using Digital Sampling Technique)

  • 위제싱허;박영태
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.686_687
    • /
    • 2009
  • The traceability maintenance system for the AC voltage and current has been developed at the frequency range of 20 Hz to 100 Hz without using any compensation technique which is used at thermal converter (TC) ac-dc transfer system at low frequencies. The system uses a digital voltmeter (DVM) as a data acquisition system of the input waveform and stored data in memory. The developed algorithm acquires and processes the sampling data to calculate the root mean square (rms) value of the input voltage of DVM which operates at DC 10 V range for better accuracy. The best uncertainty of the AC voltage measurements is $3 {\mu}V/V$ within the frequency range. The best uncertainty of the AC current measurements is better than the $5 {\mu}A/A$ and mainly depend on the current to voltage converter, ac-dc current shunt or Current Transformer (CT), used for the measurement

  • PDF

Pulse Width and Pulse Frequency Modulated Soft Commutation Inverter Type AC-DC Power Converter with Lowered Utility 200V AC Grid Side Harmonic Current Components

  • Matsushige T.;Ishitobi M.;Nakaoka M.;Bessyo D.;Yamashita H.;Omori H.;Terai H.
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.484-488
    • /
    • 2001
  • The grid voltage of commercial utility power source hi Japan and USA is 100rms, but in China and European countries, it is 200rms. In recent years, In Japan 200Vrms out putted single phase three wire system begins to be used for high power applications. In 100Vrms utility AC power applications and systems, an active voltage clamped quasi-resonant Inverter circuit topology using IGBTs has been effectively used so far for the consumer microwave oven. In this paper, presented is a half bridge type voltage-clamped high-frequency Inverter type AC-DC converter using which is designed for consumer magnetron drive used as the consumer microwave oven in 200V utility AC power system. This zero voltage soft switching Inverter can use the same power rated switching semiconductor devices and three-winding high frequency transformer as those of the active voltage clamped quasi-resonant Inverter using the IGBTs that has already been used for 100V utility AC power source. The operating performances of the voltage source single ended push pull type Inverter are evaluated and discussed for consumer microwave oven. The harmonic line current components In the utility AC power side of the AC-DC power converter operating at ZVS­PWM strategy reduced and improved on the basis of sine wave like pulse frequency modulation and sine wave like pulse width modulation for the utility AC voltage source.

  • PDF

고효율 공진형 비대칭 하프브리지 플라이백컨버터 (High Efficiency Resonant Asymmetrical Half-Bridge Flyback Converter)

  • 정강률;유두희
    • 조명전기설비학회논문지
    • /
    • 제24권4호
    • /
    • pp.81-94
    • /
    • 2010
  • 본 논문에서는 고효율 공진형 비대칭 하프브리지 플라이백컨버터가 제안된다. 컨버터의 1차측 하프브리지 회로는 공진커패시턴스와 변압기 누설인덕턴스를 이용하여 비대칭 펄스폭변조(PWM; Pulse-Width Modulation) 방식에 의한 소프트스위칭 형태로 동작한다. 그리고 컨버터 2차측의 플라이백 회로는 간단한 구동회로에 의해 새로운 전압구동방식으로 동작하는 동기정류기를 이용한다. 제안된 컨버터는 이렇게 하여 컨버터의 전체효율을 향상시킨다. 또한 본 논문에서는 제안된 컨버터의 동작원리를 모드별로 설명하고 컨버터 설계 시의 고려사항과 프로토타입 컨버터의 설계 예를 각각 제시한다. 그리고 본 논문에서 제안하는 전압구동방식으로 동작하는 동기정류기의 간단한 구동기법에 관하여 간략하게 설명한다. 설계된 프로토타입 컨버터는 광범위 입력전압(교류 $V_{in,rms}$=75~265[V])이 가능하며 5[V]의 직류 출력전압과 100[W]의 출력전력을 가진다. 제안된 컨버터의 우수한 성능을 입증하기 위하여 설계된 파라미터로써 프로토타입 컨버터를 제작하여 실험하였으며, 이를 통하여 제안된 컨버터의 우수한 성능을 보인다.

An Interleaving Scheme for DC-link Current Ripple Reduction in Parallel-Connected Generator Systems

  • Jeong, Min-Gyo;Shin, Hye Ung;Baek, Ju-Won;Lee, Kyo-Beum
    • Journal of Power Electronics
    • /
    • 제17권4호
    • /
    • pp.1004-1013
    • /
    • 2017
  • This paper presents an interleaving scheme for parallel-connected power systems to reduce the DC-link current ripple. A paralleled generator system generates current ripple by the Pulse Width Modulation (PWM) of each generator side converter. The current ripple in the DC-link degrades the efficiency of the whole generator system and decreases the lifetime of the DC-link capacitors. To mitigate these issues, the expression of the DC-link current is derived by a double-integral Fourier analysis while considering the modulation schemes. Optimized interleaving angles for the parallel generator system are obtained based on an analysis to minimize the dominant current harmonics component. Finally, the proposed interleaving scheme reduces the RMS value of the DC-link current ripple. Simulation and experimental results verify the effectiveness of the proposed interleaving scheme.

음향 방출을 이용한 저어널 베어링의 조기 파손 감지(III) -저어널 베어링 AE 진단 시스템 개발- (Acoustic Emission Monitoring of Incipient Failure in Journal Bearings( III ) - Development of AE Diagnosis System for Journal Bearings -)

  • 정민화;조용상;윤동진;권오양
    • 비파괴검사학회지
    • /
    • 제16권3호
    • /
    • pp.155-161
    • /
    • 1996
  • 회전 기계의 저어널 베어링 상태를 음향 방출(AE) 기술을 활용하여 감시하기 위한 진단 시스템을 개발하였다. AE 기술은 베어링 시스템에 있어서 비정상 상태를 탐지하기 위하여 이용된다 모의 저어널 베어링시스템을 이용한 실험과 실제 발전 설비에 대한 적용 시험의 결과로부터 AE 신호 파라메타 중에서 rms voltage가 가장 유효한 것으로 판명되었으며, 이러한 연구 결과를 토대로 하여 진단 시스템의 알고리즘과 판단 기준들이 설정되었다. 베어링 진단 시스템은 AE 센서 및 전치앰프로 구성된 신호 감지부, AE rms voltage를 측정하기 위한 rms-to-DC 변환 회로부로 구성된 신호 처리부, A/D 변환기를 이용하여 rms voltage 신호를 PC에 연결해 주는 인터페이스부, 베어링 상태 보기와 진단 프로그램을 포함하는 그래픽 디스플레이 및 소프트웨어부의 4부분으로 구성된다.

  • PDF

A Single-Stage LED Tube Lamp Driver with Input-Current Shaping for Energy-Efficient Indoor Lighting Applications

  • Cheng, Chun-An;Chang, Chien-Hsuan;Cheng, Hung-Liang;Chung, Tsung-Yuan;Tseng, Ching-Hsien;Tseng, Kuo-Ching
    • Journal of Power Electronics
    • /
    • 제16권4호
    • /
    • pp.1288-1297
    • /
    • 2016
  • This study proposes a single-stage light-emitting diode (LED) tube lamp driver with input-current shaping for T8/T10-type fluorescent lamp replacements. The proposed AC-DC LED driver integrates a dual-boost converter with coupled inductors and a half-bridge series-resonant converter with a bridge rectifier into a single-stage power conversion topology. This paper presents the operational principles and design considerations for one T8-type 18 W-rated LED tube lamp with line input voltages ranging from 100 V rms to 120 V rms. Experimental results for the prototype driver show that the highest power factor (PF = 0.988), lowest input current total harmonic distortion (THD = 7.22%), and highest circuit efficiency (η = 92.42%) are obtained at an input voltage of 120 V. Hence, the proposed driver is feasible for use in energy-efficient indoor lighting applications.

6.6㎸/200A급 DC 리액터헝 초전도한류기의 단시간운전 및 단락시험 (Short-term Run and Short-circuit Test of 6.6㎸/200A DC reactor Type Superconducting Fault Current Limiter)

  • 안민철;이승제;강형구;배덕권;윤용수;고태국
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 추계학술대회 논문집
    • /
    • pp.10-13
    • /
    • 2003
  • 6.6㎸rms/200Arms DC reactor type superconducting fault current limiter (SFCL) has been developed. This paper deals with the manufacture and short-circuit test of the SFCL. DC reactor was the HTS solenoid coil whose inductance was 84mH. AC/DC power converter was performed as the dual-mode operation. The short-term run(1 sec) and short-circuit test of this SFCL was performed successfully. The experimental results have a similar tendency to the simulation results. In short-circuit test, at 2 cycles after the fault, fault current limitation rate was about 30%.

  • PDF