• Title/Summary/Keyword: RMS converter

Search Result 105, Processing Time 0.024 seconds

A V-I Converter Design for Power Variation Insensitivity PLL (전원 전압 변화에 둔감한 PLL을 위한 V-I 변환기 설계)

  • Lee, Hyun-Seok;Hong, Dong-Hee;Park, Jong-Wook;Lim, Shin-Il;Sung, Man-Young
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.44 no.3 s.357
    • /
    • pp.59-64
    • /
    • 2007
  • This paper describes the PLL of TCON(Timing Controller) chip for FPD(Flat Panel Display). We propose a new V-I converter which is insensitive to the power supply variation when it is applied to the TCON. The new V-I converter compensated the output frequency of VCO by appling the current that is inversely proportional to the voltage variation. The proposed idea is implemented with a 1-ploy 3-metal 0.25m TSMC CMOS technology and has the output frequency range from 192MHz to 360MHz at the supply voltage of 2.5V. Measurement result shows the RMS jitter of 100ps in the above output frequency range.

Acoustic Emission Monitoring of Incipient Failure in Journal Bearings( III ) - Development of AE Diagnosis System for Journal Bearings - (음향 방출을 이용한 저어널 베어링의 조기 파손 감지(III) -저어널 베어링 AE 진단 시스템 개발-)

  • Chung, Min-Hwa;Cho, Yong-Sang;Yoon, Dong-Jin;Kwon, Oh-Yang
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.16 no.3
    • /
    • pp.155-161
    • /
    • 1996
  • For the condition monitoring of the journal bearing in rotating machinery, a system for their diagnosis by acoustic emission(AE) was developed. AE has been used to detect abnormal conditions in the bearing system. It was found from the field application study as well as the laboratory experiment using a simulated journal bearing system that AE RMS voltage was the most efficient parameter for the purpose of current study. Based on the above results, algorithms and judgement criteria for the diagnosis system was established. The system is composed of four parts as follows: the sensing part including AE sensor and preamplifier, the signal processing part for RMS-to-DC conversion to measure AE ms voltage, the interface part for transferring RMS voltage data into PC using A/D converter, and the software part including the graphic display of bearing conditions and the diagnosis program.

  • PDF

A New High Frequency Linked Soft-Switching PWM DC-DC Converter with High and Low Side DC Rail Active Edge Resonant Snubbers for High Performance Arc Welder

  • Kang, Ju-Sung;Fathy, Khairy;Hong, Doo-Sung;Suh, Ki-Young;Lee, Hyun-Woo;Nakaoka, Mutsuo
    • Proceedings of the KIEE Conference
    • /
    • 2006.04b
    • /
    • pp.281-283
    • /
    • 2006
  • This paper presents two new circuit topologies of DC bus lineside active edge resonant snubber assisted soft-switching PWM full-bridge DC-DC converter acceptable for either utility AC 200V-rms or AC 400V-rms input voltage source. All the active power switches in the full-bridge arms and DC busline can achieve ZCS turn-on and ZVS turn-off commutations and the total turn-off switching power losses of all active switches can be reduced for high-frequency switching action. The effectiveness of these new DC-DC converters topologies is proved for low voltage and large current high efficiency DC-DC power supplies as TIG arc welding machine from a practical point of view.

  • PDF

Design of High Power Density AC/DC Adapter (고전력밀도 AC/DC 어댑터의 설계)

  • Lee, Jun-Young
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.15 no.4
    • /
    • pp.259-265
    • /
    • 2010
  • The proposed method offers an improved control method for high power density AC/DC adapter by using more energy efficient electrical equipments. Power factor corrector (PFC) topology is based on boost topology with boundary conduction mode (BCM) and DC/DC topology is based on LLC resonant converter, which helps to reduce size of the semiconductor and the magnetic devices. Test results with 85W AC/DC adapter (18.5V/4.6A) design shows that the measured efficiency is 90% at $90V_{rms}$ input voltage with power density of $36W/in^3$. It also shows low no load power consumption of about 0.5W.

A NEW ZVS SEM1-RESONANT HIGH POWER FACTOR RECTIFIER WITH REDUCED CONDUCTION LOSSES (도통손실을 감소시킨 새로운 반 공진형 ZVS 고역률 정류기)

  • Lim, Kyoung-Hwan;Kim, Tai-Woong;Lee, Seung-Bak
    • Proceedings of the KIEE Conference
    • /
    • 1997.07f
    • /
    • pp.1993-1998
    • /
    • 1997
  • This paper presentes a novel single-phase unity power factor rectifer, which features Critical Conduction Mode and ZVS. The reduced conduction losses are achieved by the employment of a single converter instead of the typical configuration composed of a front end rectifier followed by a boost converter. Theoretical analysis, a design example and experimental results of a 300 converter with $127V_{rms}$ input voltage and 400 VDC output voltage are presented.

  • PDF

Novel soft switching FB DC-DC converter (새로운 소프트 스위칭 FB DC-DC 컨버터)

  • 김은수;최해영;조기연;계문호;김윤호
    • Proceedings of the KIPE Conference
    • /
    • 1997.07a
    • /
    • pp.251-255
    • /
    • 1997
  • The conventional high frequency phase-shifted full bridge dc/dc converter has a disadvantage that a circulating current flows through transformer and switching devices during the freewheeling interval. Due to this circulating current, RMS current stress, conduction losses of transformer and switching devices are increased. To alleviate this problem, this paper provides a circulating current free type high frequency soft switching phase-shifted full bridge (FB) dc/dc converter with energy recovery snubber (ERS) attached at the secondary side of transformer. The energy recovery snubber (ERS) adopted in this study is consisted of three fast recovery diode(Ds1, DS2, Ds3), two resonant capacitor (Cs1, Cs2)

  • PDF

High Power Factor High Efficiency PFC AC/DC Converter for LCD Monitor Adapter (LCD 모니터의 어댑터를 위한 고역률 고효율 PFC AC/DC 컨버터)

  • Park K. H.;Kim C. E.;Youn M. J.;Moon G. W.
    • Proceedings of the KIPE Conference
    • /
    • 2003.11a
    • /
    • pp.85-89
    • /
    • 2003
  • Many single-stage PFC(power-facto.-correction) ACHC converters suffer from the high link voltage at high input voltage and light load condition. In this paper, to suppress the link voltage, a novel high power factor high efficiency PFC AC/DC converter is proposed using the single controller which generates two gate signals so that one of them is used far gate signal of the flyback DC/DC converter switch and the other is applied to the Boost PFC stage. A 130w prototype for LCD monitor adapter with universal input $(90-265V_{rms})$ and 19.5V 6.7A output is implemented to verify the operational principles and performances. The experimental results show that the maximum link voltage stress is about 450V at 270Vac input voltage. Moreover, efficiency and power factor are over $84\%$ and 0.95, respectively, under the full load condition.

  • PDF

Efficient Switch Mode Power Supply Design with Minimum Components for 5W Output Power

  • Singh, Bhim;Chaturvedi, Ganesh Dutt
    • Journal of Electrical Engineering and Technology
    • /
    • v.4 no.1
    • /
    • pp.79-86
    • /
    • 2009
  • This paper presents a flyback technology in power conversion aimed at increasing efficiency and power density, reducing cost and using minimum components in AC-DC conversion. The proposed converter provides these features for square waveforms and constant frequency PWM. It is designed to operate in a wide input voltage range of 75-265VAC RMS with two output voltages of 5V and 20V respectively and full load output power of 5W. The proposed converter is suitable for high efficiency and high power density application such as LCDs, TV power modules, AC adapters, motor control, appliance control, telecom and networking products.

탭인덕터와 스너버 캐패시터를 이용한 영전압 영전류 스위칭 DC/DC 컨버터

  • Kim E.S.;Byun Y.B.;Joe K.Y.;Kim T.J.;Kim Y.H.
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.689-693
    • /
    • 2001
  • The conventional three-level high frequency phase-shifted dc/dc converter has a disadvantage that a circulating current flows through transformer and switching devices during the freewheeling interval. Due to this circulating current and RMS current stress, conduction losses of transformer and switching devices increases. To alleviate these problems, we propose an improved three-level Zero Voltage and Zero Current Switching (ZVZCS) dc/dc converter using a tapped inductor, a snubber capacitor and two snubber diodes attached at the secondary side of transformer. The proposed ZVZCS converter is verified on a 10 kW, 30kHz experimental prototype.

  • PDF

An Efficiency-Optimized Modulation Strategy for Dual-Active-Bridge DC-DC Converters Using Dual-Pulse-Width-Modulation in the Low Power Region

  • Byen, Byeng-Joo;Ban, Chung-Hwan;Lim, Young-Bae;Choe, Gyu-Ha
    • Journal of Power Electronics
    • /
    • v.17 no.6
    • /
    • pp.1413-1421
    • /
    • 2017
  • In order to control the output voltage in a dual active bridge converter, this paper establishes a theoretical inductor current equation for a dual-pulse-width-modulation scheme that ensures low switching loss. It also proposes a modulation strategy that minimizes conduction loss. When compared to the conventional single-pulse-width-modulation strategy, the proposed approach can reduce the inductor current RMS and improve efficiency in the low power region, as verified through simulation and experimental results.