• Title/Summary/Keyword: RMS Voltage

Search Result 308, Processing Time 0.024 seconds

Three-Phase Line-Interactive Dynamic Voltage Restorer with a New Sag Detection Algorithm

  • Jeong, Jong-Kyou;Lee, Ji-Heon;Han, Byung-Moon
    • Journal of Power Electronics
    • /
    • v.10 no.2
    • /
    • pp.203-209
    • /
    • 2010
  • This paper describes the development of a three-phase line-interactive DVR with a new sag detection algorithm. The developed detection algorithm has a hybrid structure composed of an instantaneous detector and RMS-variation detectors. The source voltage passes through the sliding-window DFT and RMS calculator, and the instantaneous sag detector. If an instantaneous sag is detected, the RMS variation detector-1 is selected to calculate the RMS variation. The RMS variation detector-2 is selected when the instantaneous sag occurs under the operation of the RMS variation detector-1. The feasibility of the proposed algorithm is verified through computer simulations and experimental work with a prototype of a line-interactive DVR with a 3kVA rating. The line-interactive DVR with the proposed algorithm can compensate for an input voltage sag or an interruption within a 2ms delay. The developed DVR can effectively compensate for a voltage sag or interruption in sensitive loads, such as computers, communications equipment, and automation equipment.

Accurate Calculation of RMS Value of Grid Voltage with Synchronization of Phase Angle of Sampled Data (샘플링 시점의 위상각 동기화를 이용한 계통전압 실효값의 정확한 계산 방법)

  • Ham, Do-Hyun;Kim, Soo-Bin;Song, Seung-Ho;Lee, Hyun-Young
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.23 no.6
    • /
    • pp.381-388
    • /
    • 2018
  • A novel and simple algorithm for accurate calculation of RMS voltage is proposed in a digitally controlled grid-tie inverter system. Given that the actual frequency of grid voltage is continuously changing, the constant sampling frequency cannot be a multiple number of the fundamental frequency. Therefore, the RMS of grid voltage contains periodic oscillations due to the differences in the phase angle of sampled data during calculation. The proposed algorithm precisely calculates and updates the initial phase angle of the first sampled voltage in a half-cycle period using phase-locked loop, which is commonly utilized for phase angle detection in grid-tie inverter systems. The accuracy and dynamic performance of the proposed algorithm are compared with those of other algorithms through various simulations and experiments.

3-Phase RMS Voltage Measurement Method of Virtual Frequence using Instantaneous Power Component Concept (순시전력 합성 개념을 이용한 가상주파수 3상 실효전압 계측기법)

  • Park, Seong-Mi;Yang, Ji-Hoon;Park, Sung-Jun
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.22 no.3
    • /
    • pp.251-257
    • /
    • 2019
  • This paper proposes a new measurement method using virtual power concept to measure the effective value of 3-phase voltage with variable frequency. The conventional effective value measurement method uses a method of integrating data sampled during one or half cycle of the power voltage and averaging it. In this method, since the effective voltage is calculated every cycle, a time delay occurs in the measured effective voltage and it is s a problem to measure the effective value of a device whose frequency varies from time to time, such as a generator. The proposed 3-phase voltage rms measurement method has an advantage that it can measure accurate voltage RMS value regardless of measurement frequency variation. In particular, there is an advantage in that it is possible to measure a 3-phase effective voltage rather than an average value of the effective voltage of each phase in a 3-phase unbalance voltage. In addition, the validity of the proposed method is verified by using the Psim simulation tool and the experimental results are analyzed by applying the proposed measurement algorithm to the actual three phase synchronous generator voltage measurement experiment.

Acoustic Emission Monitoring of Incipient Failure in Journal Bearings( III ) - Development of AE Diagnosis System for Journal Bearings - (음향 방출을 이용한 저어널 베어링의 조기 파손 감지(III) -저어널 베어링 AE 진단 시스템 개발-)

  • Chung, Min-Hwa;Cho, Yong-Sang;Yoon, Dong-Jin;Kwon, Oh-Yang
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.16 no.3
    • /
    • pp.155-161
    • /
    • 1996
  • For the condition monitoring of the journal bearing in rotating machinery, a system for their diagnosis by acoustic emission(AE) was developed. AE has been used to detect abnormal conditions in the bearing system. It was found from the field application study as well as the laboratory experiment using a simulated journal bearing system that AE RMS voltage was the most efficient parameter for the purpose of current study. Based on the above results, algorithms and judgement criteria for the diagnosis system was established. The system is composed of four parts as follows: the sensing part including AE sensor and preamplifier, the signal processing part for RMS-to-DC conversion to measure AE ms voltage, the interface part for transferring RMS voltage data into PC using A/D converter, and the software part including the graphic display of bearing conditions and the diagnosis program.

  • PDF

A Study for Effects of Image Quality due to Scatter Ray produced by Increasing of Tube Voltage (관전압 증가에 기인한 산란선 발생의 화질 영향 연구)

  • Park, Ji-Koon;Jun, Je-Hoon;Yang, Sung-Woo;Kim, Kyo-Tae;Choi, Il-Hong;Kang, Sang-Sik
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.7
    • /
    • pp.663-669
    • /
    • 2017
  • In diagnostic medical imaging, it is essential to reduce the scattered radiation for the high medical image quality and low patient dose. Therefore, in this study, the influence of the scattered radiation on medical images was analyzed as the tube voltage increases. For this purpose, ANSI chest phantom was used to measure the scattering ratio, and the scattering effect on the image quality was investigated by RMS evaluation, RSD and NPS analysis. It was found that the scattering ratio with increasing x-ray tube voltage gradually increased to 48.8% at 73 kV tube voltage and to 80.1% at 93 kV tube voltage. As a result of RMS analysis for evaluating the image quality, RMS value according to increase of tube voltage was increased, resulting in low image quality. Also, the NPS value at 2.5 lp/mm spatial frequency was increased by 20% when the tube voltage was increased by 93 kV compared to the tube voltage of 73 kV. From this study, it can be seen that the scattering radiation have a significant effect on the image quality according to the increase of x-ray tube voltage. The results of this study can be used as basic data for the improvement of medical imaging quality.

Barkhausen Noise Characteristics of 3Cr-1Mo Steel with Heat-treatment (열처리에 따른 3Cr-1Mo강의 Barkhausen noise 특성)

  • Nam, Young-Hyun
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.21 no.4
    • /
    • pp.199-204
    • /
    • 2008
  • The destructive method is reliable and widely used for evaluating the properties of material but it is time-consuming and difficult to prepare specimens from in-service industrial facilities. In the present research, Barkhausen Noise (BN) has been used to evaluate changes of mechanical properties due to heat treatment condition. The BN voltage (rms voltage) was measured with grain size. The rms voltage of BN increased with the heat treatment temperature ($870{\sim}1000^{\circ}C$) because the grain size increased with the temperature. The rms voltage of BN decreased with various heat treatment processes, such as quenched, tempered and PWHT. The BN can be used for the nondestructive evaluation of the forged reactor vessels. and moreover, it may be effectively used in the field application.

Current and voltage loading tests off resistive SFCL

  • 최효상;현옥배;김혜림;황시돌;박권배
    • Progress in Superconductivity
    • /
    • v.3 no.2
    • /
    • pp.241-246
    • /
    • 2002
  • We have performed the current and voltage loading tests of resistive superconducting fault current limiters (SFCLS) based on $YBa_2$$Cu_3$$O_{7}$(YBCO) films with the diameter of 2 inch. The SFCL consists of meander-type YBCO stripes covered with 200 nm Au layer grown in situ for current shunt and heat dispersion at hot spots. The minimum quench current of an SFCL unit was about 25 Apeak. Seven SFCL units were connected in parallel fur the current load ing tests at power source of 100 $V_{rms}$ $/2,000A_{rms}$. This SFCL units had maximum limiting current of 170 Apeak during the fault instant and then successfully controlled the fault current below 100 Apeak within 1~2 msec after short circuit. Increased short current also reduced the quench completion time with little change of current limiting characterization. We connected six SFCL units in series fur the voltage loading tests at power source of $1,200 V_{rms}$/170 $A_{rms}$ at this time. The shunt resistors were inserted into each SFCL unit to eliminate power imbalance originated from serial connection of SFCL units. Each SFCL unit was quenched simultaneously during the fault condition. The current increased up to 40 $A_{peak}$ and decreased to 14 $A_{peak}$ after 3 cycles. Quench was completed within 1 msec after the fault. We confirmed operating characteristics of 140 kVA($120 A_{rms}$ $\times$ 1,200 $V_{rms}$) SFCL and presented the manufacturing possibility of 3.3 kV SFCL using 4 inch YBCO films.BCO films.lms.

  • PDF

NEW ADAPTIVE METHOD FOR VOLTAGE SAG AND SWELL DETECTION

  • Mohamed, Mansour A.
    • Journal of the Korea Convergence Society
    • /
    • v.4 no.1
    • /
    • pp.33-41
    • /
    • 2013
  • This paper presents an adaptive recursive least squares algorithm (ARLS) for detecting voltage sag and voltage swell events in power systems. Different methods have been developed to detect voltage sag and voltage swell. Some of them use window techniques, which are too slow when voltage sag or swell mitigation is required. Others depend on the extraction of a single non-stationary sinusoidal signal out of a given multi-components input signal, and therefore they don't consider the harmonic components in calculating the voltage root mean square value (rms). The method, proposed in this paper, is capable of estimating the voltage rms taking into account all harmonic components. The method is tested by applying it to different, simulated signals using ATP program, and compared with voltage sag detection algorithms.

Development of new Multifunction Voltage Recorder (다기능 디지털 전압기록장치 시스템 개발)

  • Shon, Su-Goog;Choi, Sang-Joon
    • Proceedings of the KIEE Conference
    • /
    • 1999.11c
    • /
    • pp.693-696
    • /
    • 1999
  • This paper describes a new voltage recorder for the voltage management of a power distribution line by using a new voltage measurement technique. The RMS(Root Mean Square) voltage measurement for the power line under the assumption of a sinusoidal input voltage is taken by the full-wave rectifier, half-adder utilizing operational amplifier(OP) circuit. A/D converter utilizing a dual slope converter converts an analog voltage signal into a serial pulse. The pulse is counted with a single chip micro-controller, converted with the RMS voltage, and saved into a flash memory. In the last, a new voltage recorder with compact size and multifunction is developed. Also, Voltage Management System that can analyze the stored data via RS-232C cable is developed based on Windows 95 and Visual C++.

  • PDF

A Single-Stage Power Factor Correction Converter for 90-265$V_{rms}$ Line Applications (90-265$V_{rms}$ 입력범위를 갖는 단일전력단 역률개선 컨버터)

  • 구관본
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.145-149
    • /
    • 2000
  • A single-stage power factor correction AC/DC converter with a simple link voltage suppressing circuit (LVSC) for the universal line application is proposed. Using this simple circuit a low link voltage can be realized without deadbands at line zero-crossings. The proposed converter is analyzed and a prototype converter with 5C, 12V output is implemented to verify the performance. The experimental results show that the link voltage stress and efficiency are about 447V and 81%, respectively.

  • PDF