• Title/Summary/Keyword: RI Test

Search Result 584, Processing Time 0.029 seconds

Study on Electrical Environmental Obstacle Using a 765kV Double Circuit Test Line (765kV 시험선로를 이용한 전기환경장해 특성연구)

  • Kim, Jeong-Boo;Jo, Seong-Sae;Shin, Goo-Yong;Lee, Dong-Il;Yang, Kwang-Ho;Ahn, Hee-Sung;Bae, Jeong-Hyo;Koo, Ja-Yoon;Min, Seok-Weon
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1517-1519
    • /
    • 1994
  • This paper describes electrical environmental study of a 765kV double circuit test line. Corona performance on several candidate conductor bundles has been investigated in the corona cage (single phase simulation facility) since 1984. We have known that six RAIL conductor bundle is the most suitable for the 765kV transmission Line, [3] To investigate electrical environmental impact of the future commerciale line, we build a full sacle 765kV test line in 1993. The test results of Audible Noise, Radio Interference, TV Interference from August, 1993 to Jan. 1994 were measured as $48.7[dBA](L_{50})$. $57.4[dB{\mu}V/m]$(Fair weather, $L_{50})$. $14.5[dB${\mu}$V/m]$(Fair weather, $L_{50}$). We have found that the Audible Noise data were very close to the predicted(48.5 [dBA]) by BPA Corona and Field Effects Computer program, however, the RI and TVI data were much higher than predicted(42 [dBmV/m], $7.9[dB{\mu}V/m)$ by the BPA program. We have investigating the reason of the difference. In the constructing of full scale test line, we developed the tubular tower, 765kV test transformer and hardwares of 765kV transmission line insulator strings. Also we will investigate the effects of plants under the 765kV test Line.

  • PDF

Stepping Trail Making Test: Preliminary Study for the Effectiveness of the Novel Dual Task Assessment Tool for Physical and Cognitive Functions in Elderly (보행기호잇기검사: 새로운 신체 및 인지 기능에 대한 이중 과제 평가도구로서의 효용성에 대한 예비연구)

  • Ju-Ri Eom;Byeong-Ju Lee
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.18 no.2
    • /
    • pp.41-48
    • /
    • 2023
  • PURPOSE: Falls are caused by a decline in physical and cognitive function. A quantitative evaluation tool that can comprehensively evaluate motor and cognitive functions for elderly people with an impaired physical function. This study assessed the clinical application potential by confirming the correlation between the physical function tests, cognitive and the stepping trail-making test (S-TMT). METHODS: Fourteen community-dwelling older patients (65-75 years) were recruited. The study conducted cognitive function tests with the trail-making test (TMT-A, B), and physical function tests (6-minute walking test (6MWT), short physical performance battery (SPPB), and timed up and go (TUG)). The results of were analyzed using SPSS version 21.0. Descriptive statistics were used for the general characteristics of the study subjects, and the correlations between S-TMT, other functional tests were examined through Pearson's correlation analysis. The statistical significance was set to .05. RESULTS: S-TMT had a significant positive correlation with the TUG (r = .588*) and trail-making test-B (TMT-B) (r = .689*, p < .05). Furthermore, S-TMT showed a negative correlation between SPPB (r = -.397) and 6MWT (r = -.422), but it was not statistically significant. CONCLUSION: S-TMT is a cognitive-gait dual-task performance evaluation tool that can be performed safely. A significant correlation was confirmed between the TUG test and the TMT-B. S-TMT is a dual-task screening tool that can evaluate both physical and cognitive functions simultaneously.

Single-center experience of the Korean-Developmental Screening Test for infants and children

  • Suh, Chae-Ri;Sohn, Su Ye;Kim, Gun-Ha;Jung, Seong-Kwan;Eun, Baik-Lin
    • Clinical and Experimental Pediatrics
    • /
    • v.59 no.12
    • /
    • pp.483-489
    • /
    • 2016
  • Purpose: We investigated the number of test takers of the Korean-Developmental Screening Test (K-DST) in a single children's hospital within a year, according to age, referral rate, and follow-up percentage. Methods: For this study, 4,062 children who visited and received K-DST at Woorisoa Children's Hospital between January and December 2015 were enrolled. Seven test sets were used according to the Korean National Health Screening Program for infants and children in the following age groups: 4 to 6, 9 to 12, 18 to 24, 30 to 36, 42 to 48, 54 to 60, and 66 to 71 months. The results of the K-DST were categorized into 4 groups as follows: further evaluation (<-2 standard deviation [-2SD]), follow-up test (-2SD to -1SD), peer level (-1SD to 1SD), and high level (>1SD). Results: The test participants' population and follow-up population were concentrated before the age of 24 months (2,532, 62.3%). The children most commonly referred for further evaluation were those in the 30- to 41-month age group. A mismatch was found between the results of the K-DST and the additional questions. Most of the infants and children with suspicious developmental delays showed catch-up development in their follow-up tests (43 of 55, 78.2%). Conclusion: The use of K-DST should be encouraged, especially among children aged over 24 months. Multiple-choice question format for the additional questions is recommended to avoid confusion. We suggest a nationwide study to evaluate and revise the K-DST.

Corrosion and Photo-Reflection Behavior of Aluminum and Stainless Steel During Immersion Test in Salt Solution (3 wt% NaCl 수용액에서 알루미늄과 스테인리스강의 부식에 따른 광 반사 거동)

  • Cho, Soo Yeon;Na, Hyeon Gyu;Cho, Hye Ri;Moon, Jong Ju;Ahn, Tae-Jung;Jang, HeeJin
    • Corrosion Science and Technology
    • /
    • v.19 no.3
    • /
    • pp.109-114
    • /
    • 2020
  • The photo-reflectance of aluminum and AISI 304 stainless steel during cyclic immersion test in 3 wt% NaCl solution was examined in this study. Overall, corrosion was not recognized by a visual inspection or weight measurement up to 310 h. When evaluated, it was noted that the roughness of the specimens did not change significantly. However, localized corrosion, which is located at the vicinity of intermetallic precipitation of aluminum or at the grain boundary of stainless steel, was confirmed by the use of an optical microscope and scanning electron microscopy after tens of hours of utilizing the corrosion test. In this respect, an increase of the peak intensity for metallic Al after 90 h of test, and for metallic Fe after 153 h was detected from the X-ray photoelectron spectra. In this context, it was shown that from the photo-reflectance spectra, the reflection of the visible light from the tested samples was changed noticeably over the test duration. As a result, the intensity of reflected light was decreased up to 90 h ~ 153 h, and thereafter was shown to increase higher than the initial intensity before the corrosion test.

Evaluation of Eye Irritation Potential of Solid Substance with New 3D Reconstructed Human Cornea Model, MCTT HCETM

  • Jang, Won-hee;Jung, Kyoung-mi;Yang, Hye-ri;Lee, Miri;Jung, Haeng-Sun;Lee, Su-Hyon;Park, Miyoung;Lim, Kyung-Min
    • Biomolecules & Therapeutics
    • /
    • v.23 no.4
    • /
    • pp.379-385
    • /
    • 2015
  • The eye irritation potential of drug candidates or pharmaceutical ingredients should be evaluated if there is a possibility of ocular exposure. Traditionally, the ocular irritation has been evaluated by the rabbit Draize test. However, rabbit eyes are more sensitive to irritants than human eyes, therefore substantial level of false positives are unavoidable. To resolve this species difference, several three-dimensional human corneal epithelial (HCE) models have been developed as alternative eye irritation test methods. Recently, we introduced a new HCE model, MCTT HCE$^{TM}$ which is reconstructed with non-transformed human corneal cells from limbal tissues. Here, we examined if MCTT HCE$^{TM}$ can be employed to evaluate eye irritation potential of solid substances. Through optimization of washing method and exposure time, treatment time was established as 10 min and washing procedure was set up as 4 times of washing with 10 mL of PBS and shaking in 30 mL of PBS in a beaker. With the established eye irritation test protocol, 11 solid substances (5 non-irritants, 6 irritants) were evaluated which demonstrated an excellent predictive capacity (100% accuracy, 100% specificity and 100% sensitivity). We also compared the performance of our test method with rabbit Draize test results and in vitro cytotoxicity test with 2D human corneal epithelial cell lines.

Nonlinear Characteristic of a Tuned Liquid Column Damper under Various Excitation Amplitudes (가진입력의 크기에 따른 동조액체기둥감쇠기의 비선형 특성)

  • Lee, Sung-Kyung;Lee, Hye-Ri;Min, Kyung-Won
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2009.10a
    • /
    • pp.842-849
    • /
    • 2009
  • The objective of this study is to investigate design parameters of a tuned liquid column damper(TLCD), which is affected by various excitation amplitudes, through shaking table test. Design parameters of a TLCD are examined based on the equivalent tuned mass damper(TMD) model of a TLCD, in which the nonlinear damping of a TLCD is transposed to equivalent viscous damping. Shaking table test is carried out for a TLCD specimen subjected to harmonic waves with various amplitudes. Transfer functions are ratios of liquid displacement of TLCD and control force produced by a TLCD, respectively, with respect to the acceleration excited by a shaking table. They are derived based on the equivalent TMD model of a TLCD. Then, the variation of design parameters according to the excitation amplitude is examined by comparing analytical transfer functions with experimental ones. Finally, the dissipation energy due to the damping of a TLCD, which is experimentally observed from the shaking table test, is examined according to the excitation amplitude. Comparisons between test results and analytical transfer functions showed that natural frequencies of TLCD and the ratio of the liquid mass in a horizontal column to the total liquid mass does not depend on the excitation amplitude, while the damping ratio of a TLCD increases with larger excitation amplitudes.

  • PDF

Nonlinear Characteristic of a Tuned Liquid Column Damper under Various Excitation Amplitude (가진입력의 크기에 따른 동조액체기둥감쇠기의 비선형 특성)

  • Lee, Sung-Kyung;Lee, Hye-Ri;Min, Kyung-Won
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.19 no.11
    • /
    • pp.1167-1176
    • /
    • 2009
  • The objective of this study is to investigate design parameters of a tuned liquid column damper(TLCD), which is affected by various excitation amplitude, through shaking table test. Design parameters of a TLCD are examined based on the equivalent tuned mass damper(TMD) model of a TLCD, in which the nonlinear damping of a TLCD is transposed to equivalent viscous damping. Shaking table test is carried out for a TLCD specimen subjected to harmonic waves with various amplitude. Transfer functions are ratios of liquid displacement of TLCD and control force produced by a TLCD, respectively, with respect to the acceleration excited by a shaking table. They are derived based on the equivalent TMD model of a TLCD. Then, the variation of design parameters according to the excitation amplitude is examined by comparing analytical transfer functions with experimental ones. Finally, the dissipation energy due to the damping of a TLCD, which is experimentally observed from the shaking table test, is examined according to the excitation amplitude. Comparisons between test results and analytical transfer functions showed that natural frequencies of TLCD and the ratio of the liquid mass in a horizontal column to the total liquid mass do not depend on the excitation amplitude, while the damping ratio of a TLCD increases with larger excitation amplitude.

Investigation of Antimicrobial Activity of Brown Algae Extracts and the Thermal and pH Effects on Their Activity

  • Lee, So-Young;Kim, Jin-Hee;Song, Eu-Jin;Kim, Koth-Bong-Woo-Ri;Hong, Yong-Ki;Lim, Sung-Mee;Ahn, Dong-Hyun
    • Food Science and Biotechnology
    • /
    • v.18 no.2
    • /
    • pp.506-512
    • /
    • 2009
  • The antimicrobial activity of water and ethanol extracts from 30 species of algae was measured using the agar diffusion method and minimum inhibitory concentration (MIC) test. In agar diffusion method, the 95% ethanol extracts from 12 of the algae showed growth inhibition against the tested microorganisms. In particular, Ishige okamurai, Ecklonia stolonifera, Sargassum siliquastrum, Sargassum thunbergii, Colpomenia bullosa, and Ecklonia cava had strong antibacterial activities against Gram-positive bacteria at 4 mg/mL. In the results of the MIC test, S. siliquastrum showed the most antimicrobial activity, where its MIC values ranged from 0.005 to 0.0075% against Listeria monocytogenes, Clostridium perfringens, and Basillus subtilis. In the thermal stability test, for the ethanol extracts of I. okamurai, E. cava, S. siliquastrum, S. thunbergii, and C. bullosa, the extracts proved to maintain high antimicrobial activities when they were treated at $121^{\circ}C$ for 15 min. In the pH stability test, the antimicrobial activity of the S. siliquastrum ethanol extract was stable from pH 2 to 10, whereas the activity of the other species ethanol extracts were weakened under pH 10 against several microbes.

Test-retest Reliability of Sit-to-Stand and Gait Assessment Using the Wii Balance Board (Wii Balance Board를 이용한 Sit-to-Stand와 보행기능 측정의 검사-재검사 신뢰도)

  • Yang, Seong-rye;Oh, Yu-ri;Jeon, Ye-rim;Park, Dae-sung
    • Physical Therapy Korea
    • /
    • v.23 no.3
    • /
    • pp.40-47
    • /
    • 2016
  • Background: Assessments of Sit-to-Stand (STS) and gait functions are essential procedures in evaluating level of independence for the patients after stroke. In a previous study, we developed the software to analyze center of pressure (COP) in standing position on Wii Balance Board (WBB). Objects: This purpose of this study is to measure test-retest reliability of ground reaction forces, COP and time using WBB on STS and gait in healthy adults. Methods: Fifteen healthy participants performed three trials of STS and gait on WBB. The time (s), vertical peak (%) and COP path-length (cm) were measured on both tasks. Additionally, counter (%), different peak (%), symmetry ratio, COP x-range and COP y-range were analyzed on STS, 1st peak (%), 2nd peak (%) of weight were analyzed on gait. Intra-class correlation coefficient (ICC), standard error measurement (SEM) and smallest real difference (SRD) were analyzed for test-retest reliability. Results: ICC of all variables except COP path-length appeared to .676~.946 on STS, and to .723~.901 on gait. SEM and SRD of all variables excepting COP path-length appeared .227~8.886, .033~24.575 on STS. SEM and SRD excepting COP path-length appeared about .019~3.933, .054~11.879 on gait. Conclusion: WBB is not only cheaper than force plate, but also easier to use clinically. WBB is considered as an adequate equipment for measuring changes of weight bearing during balance, STS and gait test which are normally used for functional assessment in patients with neurological problems and elderly. The further study is needed concurrent validity on neurological patients, elderly patients using force plate and WBB.

Ketamine-Induced Behavioral Effects Across Different Sub-Anesthetic Dose Ranges in Adolescent and Adult Mice (다양한 마취하 용량에서 케타민에 의해 유발된 청소년기 및 성체 마우스의 행동학적 변화)

  • Choi, Hyung Jun;Im, Soo Jung;Park, Hae Ri;Lee, Seong Mi;Kim, Chul-Eung;Ryu, Seunghyong
    • Korean Journal of Biological Psychiatry
    • /
    • v.27 no.1
    • /
    • pp.27-35
    • /
    • 2020
  • Objectives Ketamine has been reported to have antidepressant effects or psychotomimetic effects. The aim of this study was to investigate the behavioral effects of ketamine treatment at various sub-anesthetic doses in adolescent and adult naïve mice. Methods In each experiment for adolescent and adult mice, a total of 60 male Institute of Cancer Research mice were randomly divided into 6 groups, which were intraperitoneally treated with physiological saline, 10, 20, 30, 40, and 50 mg/kg ketamine for consecutive 3 days. At 1 day after last injection, the locomotor and depressive-like behaviors were evaluated in mice, using open field test (OFT) and forced swim test (FST), respectively. Results In case of adolescent mice, ketamine dose was negatively correlated with total distance traveled in the OFT (Spearman's rho = -0.27, p = 0.039). In case of adult mice, we found significant positive correlation between ketamine dose and duration of immobility in the FST (Spearman's rho = 0.45, p < 0.001). Immobility time in the 50 mg/kg ketamine-treated mice was significantly higher compared to the saline-treated mice (Dunnett's post-hoc test, p = 0.012). Conclusions We found that the repeated treatment with ketamine could decrease the locomotor or prolong the duration of immobility in mice as the dose of ketamine increased. Our findings suggest that sub-anesthetic doses of ketamine might induce schizophrenia-like negative symptoms but not antidepressant effects in naïve laboratory animals.